AKRON CHILDS TILT TABLE

Similar documents
Med Aire Alternating Pressure Pump and Pad System

1 METRON MANIPULATION TABLES - WARRANTY STATEMENT

Freestander USER MANUAL

Instruction Manual for Configura Cushionair Portable Pump

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions

Paradise Pump Series Operator s Manual

Instructions for Use (IFU) Electrical Leg- & Arm lift, model , ver. 2012

SC505 Sof Care Inflator. Operating Instructions and Service Manual

CLASS CYCLE P8000 OWNER'S MANUAL JOHNSON HEALTH TECH. CO., LTD.

Use this key to determine which sections of this Product Manual apply to your job.

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

Pegasus Aircare Mattress Overlay System Models 2200 and 2201

DOC PCB901 Rotating Half Rail Instructions REV 001

BABY ROCKER WITH TOY BAR

OPERATION MANUAL ASPEN MASSAGE TABLE OR MULTI-PURPOSE LIFT TABLE. (800) (760) Fax: (760)

3 Post Pressure Fit System Owner s Manual

Digital Melting Point Apparatus

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

Alternating Pressure / Low Air Loss Mattress System

Chair Topper. Autoadapt. Hoisting and stowing. User manual

Fiber Cable Puller with Tuf-Lugger lite

Usage and Care Instructions

35 TON HYDRAULIC PUNCH WARNING

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

SAVE THESE INSTRUCTIONS. NOTE: Check all parts for shipping damage. In case of damage, DO NOT use. Contact Carrier/Invacare for further instructions.

Cascade Patient Transfer Lift System Safe Operation & Daily Maintenance Instructions

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

Owner s Manual. Model H4685

OPERATOR'S MANUAL. TOTALIFT - II LATERAL TRANSFER / TRANSPORT CHAIR Model No R02 AN

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

VERTICAL AIR COMPRESSORS

IMPORTANT:KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. ROCK A BABY BABY ROCKER WITH TOY BAR INSTRUCTION BOOK Series LX9068

Size 1. Size 2. INSTRUCTION FOR USE Prone Stander. Version 008. Max user weight: 55kg Weight of product: 32kg

BMR 2100XL Operating Instructions Page 1 of 13

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

USER MANUAL. AirPal Air Supply. (AS-1100 North America) 1488 Limeport Pike, Coopersburg, PA airpal.com fax

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

ROLLATOR (R6 and R8) OWNER S HANDBOOK

Pressure Fit System - Two Post Version Owner s Manual

LIGHTWEIGHT TRIWALKER OWNER S HANDBOOK

Installation, Operating, Inspection and Maintenance Instructions Ladder Climber s Safety System. Warning

SR8 STEEL RO LLATO R O WNER S HANDBO O K

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual

VECTA DELUXE SENSORY DISTRACTION STATION INSTRUCTION MANUAL

Technical information. 700 version software. 500 version software. 700 IFI version software. 500 IFI version software. User manual

01/18 BATH CHAIRS INSTRUCTIONS FOR USE. Code 7607,7609, 7511,7512

Air Plus User Manual

User Instructions 1789 Parapet Wall Anchor

Portable Massage Table User Manual

RESCUE LIFTING DEVICE RUP 503-[...] AT 053-[...] xx

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

Section 6 Safety Information. Section 10 Frequent Adjustments for Daily use

RO LLATO R (R6 and R8) O W NER S HANDBO O K

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 6K Puller (M6K-M)

Wildcat LB Winch Kit. Operator s Manual Installation Instructions Replacement Parts List. With Wireless Control System.

Model: 7200 Collegiate Volleyball System

Car Baby Walker 2-in-1 Baby walker

12V MINI AIR COMPRESSOR

User manual. Velo-Plus². Van Raam BV Aaltenseweg CM Varsseveld The Netherlands 06.13

MODEL: HM381 COBRA LAWN MOWER OWNER S MANUAL

USER GUIDE TO POWER ASSISTED BIKES

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

User manual. Fun-2-Go. Van Raam BV Aaltenseweg CM Varsseveld Netherlands 06.13

EXCITE. Crossover. User manual

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

Owners Manual Courtesy of ElectricScooterParts.com

SETTING THE HANDLE HEIGHT ON THE ROLLATOR

MoveRoll Conveyor Operating and Maintenance Manual

Operation Manual Guillotine Cutter RC-5

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M)

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00

VERTICAL AIR COMPRESSORS

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

User manual. Velo Plus². Van Raam BV Aaltenseweg CM Varsseveld The Netherlands. Version 14.10

HYDRAULIC MOBILE LIFTING TABLE

INSTRUCTION FOR USE Monkey

HEATHFIELD INSTRUCTIONS FOR USE

FLUX walking aid. user manual GB/US. - partnering to mobilize kids

Table of Contents Documentation for PIT TROLLEY A4

On the Go Swing System Instruction Manual

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

30000 Series Treatment Tables

LITERIDER 2&3 IMPORTANT WARNING. 2Bike (1x) Bolt (1x) Nut (1x) Small Hex Wrench (1x)

Portable Massage Table

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

The World s Best Adductors

Pectoral Machine. User manual E S S E N T I A L S T R E N G T H

On the Go Swing System Instruction Manual

Read Instructions carefully before use. Rollator is designed for indoor & outdoor use. Do NOT use as a wheelchair or as a transport chair.

TECHNICAL INFORMATION

DOLOMITE Legacy. Rollator User Manual

User Instructions 1790 Rail Anchor

MODELS (2 foot Version) (4 foot Version)

Instruction Manual: VelectriX Urban 2.0

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

INSTRUCTION MANUAL. January 23, 2003, Revision 0

OPERATIONS/PARTS MANUAL FOR PATTERSON'S WWP40BC BARGE CONNECTOR WINCH

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

GM-7000 Series CE Approved Gas Control Valve

Flat Fold Highchair INSTRUCTION MANUAL. Designed and manufactured to BS EN 14988: 2012 IMPORTANT:

Transcription:

AKRON CHILDS TILT TABLE Model 8601B USER MANUAL

Contents 1. Introduction 2 Warnings, Cautions 2 General Warnings 2 2. Installation 3 3. Operation 4 Wheel Locking 4 Tilting Control 4 Head Section, Foot Board, Pommel 5 Hand Grips, Pelvic Support 6 Work Table 7 Fixation Belts & Harnesses 8 4. Cleaning and Decontamination 9 10 5. Troubleshooting 10 6. Maintenance 11 7. Warranty and Service 12 13 8. Revision Status 13 9. Technical Specification 14 "The mark on this product demonstrates conformity with the EC Directive 93/42/EEC." 1

1. Introduction Always keep this Operating Manual available for reference. Warnings & Cautions WARNINGS Warnings identify possible hazards in procedures or conditions which, if not correctly followed, could result in death, injury or other serious adverse reactions. CAUTIONS Cautions identify conditions or procedures which, if not correctly followed, could result in equipment failure or damage. General Warnings WARNINGS Use only accessories that have been designed or approved for use with this table. Do not use electric couches in the presence of flammable gasses such as an anaesthetic agent. Maximum Load 50 Kg (110 lbs) distributed evenly. Do not concentrate weight on either side of the table. Plug acts as a disconnect device. Do not allow children to play with the table at any time. Adequately supervise children in the proximity of the table. 2

2. Installation Battery Charging CAUTION Do NOT use table when batteries are being charged. To Charge Batteries A) Plug charger lead adaptor into handswitch as shown. B) Although batteries are charged prior to packing, charge for a minimum of 12 hours before use. C) Charge batteries at the end of each day after use. Ensure mains supply cable is not stretched when connected. Ensure, during table use, no obstacles are in its path. Ensure handswitch tubes or leads are not trapped by moving parts of the table. CAUTION Ensure that the electricty supply is compatible with the table. The Voltage required is marked on the Serial No. Label. Serial No. Label 3

3. Operation Wheel Locking WARNING Lock table wheels/castors prior to patient transfer or treatment. The retractable castors are not designed for transportation of patients. Disconnect and coil electrical cord away from moving parts prior to repositioning the table. Castors Castors Unlocked Castors Locked Tilting Controls WARNING Ensure that the patient is safely positioned prior to tilting the table. Always secure the patient using the straps provided prior to tilting the table. Under no circumstances should the table be moved with the patent in situ and in tilt mode. In the interest of patient safety, always ensure that a member of staff (or other competent individual) is close at hand when the patient is in tilt. Ensure that all electrical cables are positioned away from the moving parts of the table. Press to raise table (Tilt) Press to lower table (Tilt) 4

3. Operation Head Section CAUTION Ensure Head Extension Frame is fully located in desired position before use. Foot Board To adjust the length of the Head Extension :- A) Locate locking pin on underside of top frame. B) Pull the pin out. C) Adjust Head Extension to desired position. D) The pin will spring into the holes on the Head Extension to secure. WARNING For reasons of safety, always check the Foot Board is secure before use. To adjust the Foot Board into position :- A) Unscrew locking knob at the base of the board. B) Slide Foot Board to desired position to suit patient. C) Tighten locking knob to secure Foot Board in new position. Pommel To adjust the Pommel :- A) Unscrew locking knob below the support. B) Slide Pommel to desired position. C) Tighten locking knob to secure Pommel in new position. 5

3. Operation Hand Grips To fit Hand Grips :- A) Remove Work Table (if fitted). B) Slide hand grips into fixation brackets on both sides of table. C) Tighten locking knobs on fixation brackets to secure. Hand Grips To adjust height of Hand Grips :- A) Loosen locking knobs on sliding fixation brackets on both sides of table. B) Slide hand grips along chrome rails to desired height. C) Re-tighten locking knobs to secure hand grips. Pelvic Support CAUTION The Pelvic Supports cannot be fitted at the same time as the Accessory Worktable. To fit and adjust Pelvic Support :- A) Slide support into fixation bracket on chrome rail. B) Secure pelvic support to desired height by tightening locking knob on fixation bracket. C) Adjust support to width required by tightening the second locking knob on the fixation bracket. 6

3. Operation Accessory Work Table WARNING The Accessory Work Table has a safe working load of 20 Kg. To fit the Work Table :- A) Insert Work Table Frame into sliding fixation brackets. B) Tighten locking knobs on fixation brackets to secure Work Table. Work Table To adjust the height of the Work Table :- A) Loosen locking knobs on sliding fixation brackets on both sides of table. B) Slide Worktable Assembly along chrome rails to desired height. C) Re-tighten locking knobs to secure Work Table. To alter the angle of the Work Table :- A) Unscrew hand wheel on the underside of the Work Table. Hand wheel B) Adjust Work Table to the angle required. C) Tighten hand wheel to secure Work Table in the new position. 7

3. Operation Fixation Belts and Harnesses WARNING Check condition of straps and harnesses. If worn out or damaged, replace immediately. Always ensure that the straps and harnesses are in the correct position and that the patient is fully secure before operating the tilt facility. Only use Huntleigh Akron straps and harnesses. The Table is supplied with the following Fixation Harnesses and Belts (TT3) :- 2 x Narrow Belts (TT1) 1 x Wide Belt (TT2) 2 x Wrap Straps (1H0402A) The Wide Belt is used across the patient s knees and fastened using Velcro strips, which wrap around the chrome rails. One Narrow Belt is fitted across the chest with the other across the waist. The Wrap Straps are used to hold the patients feet in place. The straps will pass through the slots in the Foot Board to secure the feet if required. Secure in place using the Velcro part of the straps. 8

4. Cleaning and Decontamination WARNING Do not use Alkalis or other organic solvents for routine cleaning. Replace torn or damaged vinyl immediately. Always cover vinyl with fresh paper or sheet between patients. If contamination is known or suspected always decontaminate couch before use. Frequency of routine couch cleaning will depend on exact application. CLEANING / DECONTAMINATION Wear suitable protective clothing Disconnect mains supply Locate couch in a suitable cleaning area with castors disengaged or wheels locked. A) Using a clean damp cloth, warm water and soap carefully wipe couch from top to bottom, taking care around electrical components. B) Wipe couch carefully from top to bottom using a damp cloth and clean water. C) Wipe couch carefully dry with clean paper towels from top to bottom. If DECONTAMINATING then repeat steps a) to c) using a dilute Hypochlorite / warm water mixture (10,000ppm) instead of warm water and soap. Safely discard cleaning / decontaminating materials. Wash hands thoroughly. Put couch back into service. 9

4. Cleaning and Decontamination Decontamination of Straps It is not recommended that the straps are laundered on a regular or routine basis as this will eventually compromise the integrity of the material and associated Tac-Flex. However, under certain conditions, ie when the straps become heavily soiled or when they are suspected or known to have been in contact with an infectious organism, they can be laundered or decontaminated using one of the following methods. General Wash The straps should be washed separately, as the Tac-Flex will attract debris from other material which will ultimately reduce its effectiveness. The Tac-Flex should be joined prior to washing. The straps may then be laundered in the normal fashion, at a temperature of approximately 71 C and allowed to dry in ambient conditions. After such wash, the straps should be thoroughly inspected prior to patient use. If deterioration is present or the Tac-Flex fails to maintain integrity, the straps must be replaced. Decontamination Eye protection and suitable clothing should be worn. Where contamination is known or suspected, the surface of the straps should be sprayed liberally using a hypochlorite solution of 1,000 ppm or a 1,000 ppm solution of sodium dichloroisocyanurate (NaDCC), after removing excessive organic material. The straps should then be air dried at ambient temperature and inspected (as above) prior to patient use. 5. Troubleshooting Electric Actuator Symptom Possible cause Action Actuator will not work Power disconnected Ensure mains supply is connected Fuse blown Hand/footswitch disconnected Replace fuse in socket Check that the hand/foot switch is fully inserted into the actuator If the problem persists consult your local Akron Supplier. 10

6. Maintenance Check table visually before use. Carry out routine servicing every six months or more frequently if in heavy use. Routine servicing or repair must only be performed by suitably qualified person. WARNING Before commencing any maintenance activity, disconnect the table from the electrical supply. Plug acts as disconnect device. Examine the table for any signs of damage. Make sure that all nuts, bolts and other fasteners are tight. Do not over tighten as this may cause binding. Upholstery fasteners should be checked, tightened or replaced if necessary. Check section hinge pins to ensure that no pin protrudes. Check gas strut controls, throughout the full range of movement for locking and assistance. Check hydraulic tables for smooth operation and signs of leakage. WARNING All electrical checks should be performed by a suitably qualified and licensed electrician. Neither BLUE or BROWN wires are to be connected to the earth terminal of a three pin plug. Examine the flexible cables for cuts, abrasions, kinking or other deterioration and replace if necessary. Ensure that the power supply connector plug is securely attached. Check mains plug connections are tight and fuse is correctly rated (5A). 11

7. Warranty and Service (UK only) Huntleigh Akron s standard terms and conditions apply to this couch. A copy is available upon request. These contain full details of warranty terms and do not limit the statutory rights of the consumer. For service or maintenance please contact: Service Department Huntleigh Healthcare 310-312 Dallow Road Luton Beds Telephone: 01582 745700 LU1 1TD Fax: 01582 745869 For information on this product, or any other Huntleigh Akron product, please contact: Huntleigh Akron 1 Farthing Road Ipswich Telephone: 01473 461042 IP1 5AP Fax: 01473 462924 Huntleigh Akron T/A a Division of Huntleigh Nesbit Evans Limited A Member of the Huntleigh Technology PLC Group of Companies Huntleigh Technology PLC 2001. If for any reason your couch is being returned, please inform Huntleigh Akron prior to sending, and: 1. Clean the product, as described in the cleaning section. 2. Pack it in suitable packing. 3. Attach the decontamination certificate (or other written statement declaring that the product has been cleaned) to the outside of the package. 4. Mark the package Service Department. Manufactured in the UK by Huntleigh Akron. As part of the ongoing development programme this company reserves the right to modify specifications and materials of this couch without notice. 12

7. Warranty and Service (UK only) Huntleigh Akron s standard terms and conditions apply to this couch. A copy is available upon request. These contain full details of warranty terms and do not limit the statutory rights of the consumer. For service, maintenance and any questions regarding this, or any other Huntleigh Akron Product, please contact: Huntleigh Akron 1 Farthing Road Ipswich Suffolk IP1 5AP. England Telephone: +44 (0) 1473 461042 Fax: +44 (0) 1473 462924 Huntleigh Akron T/A a Division of Huntleigh Nesbit Evans Limited A Member of the Huntleigh Technology PLC Group of Companies Huntleigh Technology PLC 2001. If for any reason your couch is being returned, please inform Huntleigh Akron prior to sending and: 1. Clean the product, as described in the cleaning section. 2. Pack it in suitable packing. 3. Attach the decontamination certificate (or other written statement declaring that the product has been cleaned) to the outside of the package. 4. Mark the package Service Department. Manufactured in the UK by Huntleigh Akron. As part of the ongoing development programme this company reserves the right to modify specifications and materials of this couch without notice. 8. Revision Status 8601B PAGES ISSUE WRITTEN DATE ALL PAGES UM - 01 S.Rees 04/06/98 ALL PAGES UM - 02 S.Rees 18/12/98 ALL PAGES UM - 03 P. Hammond 25/01/99 PAGE 12 & 13 UM - 04 J. Austin 15/11/99 PAGE 2 UM - 05 (DCN958) J. Barker 30/10/00 13

9. Technical Specification 8601B Width (cm) 53±1.5 Overall Length (cm) 171±3 Height Range (cm) 83±1.5 Max. Load Weight 50 Kg Tilting Control Electric Electrical Data 230v Voltage 220-240v Actuator Linak 32K-300-34-005 Power Supply CB-1A-60-24 Charger CD08-240 Input 240v ~ / 50/Hz / 14 Va Output 24v ~ / 220mA / 5.3 Va Batteries Re-order Code 5F3600Z Main Plug Fuse Rt. 5.0 A x 1 Electrical Data 110v Voltage Actuator Power Supply Charger Input Output Batteries 110v Linak 32K-300-34-005 CB-1A-60-24 CD08-110 110v ~ / 60/Hz / 14 Va 24v ~ / 220mA / 5.3 Va Re-order Code 5F3600Z IEC 601-1 Classification: Double Insulated Type B equipment Attention consult this manual 14

15

16

792-209-05 Huntleigh Akron, 1 Farthing Road, Ipswich, Suffolk, IP1 5AP, England Tel: +44 (0) 1473 461042 Fax: +44 (0) 1473 462924