How to Achieve Optimal Weighing Performance

Similar documents
Chemical Industry. School experiments. Weighing. Helper Booklet. Tips and Tricks for Weighing. Natural science laws experience live learn easily

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

General Accreditation Guidance. User checks and maintenance of laboratory balances

10 Steps to Successful Micro-Weighing

Sartorius CCL kg Prototype Mass Comparator

SmartCal. SmartCal Troubleshooting Checklist

Experiment #2. Density and Measurements

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

MS-500. User Manual. MS-500 (500g x 0.1g) Copyright 2010 Fast Weigh Scales All rights reserved. Rev. 2.0

CHM 317H1S Winter Section P Procedures and Tables

Routine Testing. SOP Temperature Calibration of Halogen Moisture Analyzer. Applicable for HR / HG / HB / MJ Moisture Analyzers

RADWAG Mass Comparators - ETERMA 2013 MASS COMPARATORS

CHM Introductory Laboratory Experiment (r17sd) 1/13

BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

AXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

The New Secura : Easy, Reliable Weighing in Regulated Areas

BASIC LABORATORY TECHNIQUES (Revised )

Operating Manual Body fat balance

Lab Equipment ANALYTICAL BALANCE

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

CRITERIA FOR LABORATORY ACCREDITATION IN MASS METROLOGY

ali-q TM Gravimetric Verification Procedure

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Microscopy Cryogenic WORKSTATION. Performance by Design

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

VOLUMETRIC TECHNIQUES

Standard Operating Procedure. Air Displacement Pipette Calibration

ANALYTICAL BALANCE OPERATING MANUAL. U.S. Solid USS-DBS Models All Rights Reserved Page 1 USS-DBS MODELS

Technical Note. Determining the surface tension of liquids by measurements on pendant drops

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

American Weigh Scales, Inc. LB User Manual

CORESTA Guide N 6. February A User Guideline for the use of balances for cigarettes and cigarette related products

Calculating Total Uncertainty of Temperature Calibration with a Dry Block. Calibration White Paper. Beamex.

QAM-I-117 Volumetric Equipment Calibration Verification

Transferpette -8/-12

Instrumentation & Data Acquisition Systems

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

VITLAB micropipette. Standard Operating Procedure (SOP)

BASIC LABORATORY TECHNIQUES (Revised )

Oct 1, 2002 LAB MANUAL SPECIFIC GRAVITY & ABSORPTION of FINE AGGREGATE AASHTO Designation T 84 (Mn/DOT Modified)

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

Recording Significant Figures

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik

Aug 17, 2001 LAB MANUAL MAXIMUM SPECIFIC GRAVITY (RICE VOIDS TEST) OF PAVING MIXTURES AASHTO Designation T 209 (Mn/DOT Modified))

Improve Process Reliability

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Pendant Drop Measurements

Density Determination Kit Instruction Manual

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

Datasheet: K-30 ASCII Sensor

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

AGREEMENT FOR DEVICE EVALUATION

THE NEW SARTORIUS 1KG-PROTOTYPE BALANCE FOR HIGH PRECISION MASS DETERMINATION

Guide No. 2/2009. Design, training and equipment Martin Firlus. Physikalisch Technische Bundesanstalt Braunschweig und Berlin

Technical Data Sheet MF010-O-LC

EPSILON. User Manual. EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

The use of the analytical balance, and the buret.

Research Question How does the concentration of catalase affect the speed of the decomposition reaction of Hydrogen Peroxide into oxygen and water?

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

technical guide Laboratory Balances Calibration Requirements

NEW: CO2 incubator with sterilizable sensor

Soil Water Characteristic Curve (SWCC) Using the WP4C

KERN EG/EW Version /02

Requirements For The Construction Of The LCLS Magnetic Measurements Laboratory

DESIGN AND PERFORMANCE OF THE NEW SARTORIUS 1 KG VACUUM MASS COMPARATOR AT PTB

Traceable calibration of automatic weighing instruments in dynamic operation

CHM250 Calibration and Measurement Lab. Balance Calibration

Buoyancy Does it Matter?

Level MEASUREMENT 1/2016

KERN CM Version /2004

Ch. 2: Tools of the Trade

NEW: CO2 incubator with sterilizable sensor

Measuring range Δp (span = 100%) Pa

Volume Determination for 2 kg~20 kg in NIM

Customer Responsibilities

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF MASS METROLOGY

Drilling Efficiency Utilizing Coriolis Flow Technology

Sartorius YDK 01, YDK 01-0D, YDK 01 LP

The Broadest Gauging Line in the Industry

VITLAB Volumetric instruments

Lecture Demonstrations Safety Manual & New Staff Induction

Calibrating a Micropipette

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF PRESSURE METROLOGY

Ensuring pipette & weighing device performance: Verification & Calibration

MICRO SCALE MEASUREMENT

THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST

LAB 14 EDITION 5 July 2015

11/22/ (4) Harmonization: <846> SPECIFIC SURFACE AREA

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

Requirements and Methods for Calibration of Equipment in Clinical Laboratories. NK Chan (HKRCBTS) 24 August 2007

CHEM 321 Experiment 1

Date Lab Time Name. Wave Motion

SOP-I-101 Operation and Calibration of the Analytical Balance

Transcription:

How to Achieve Optimal Weighing Performance

How to Achieve Optimal Weighing Performance With full-resolution 1 μg readability up to 61 g, the new Sartorius high-capacity micro balances are pushing back the limits of what is possible in weighing technology: they set a new record in accuracy with 60 million divisions. Their exceptional weighing performance and the impressive quality of their weighing results are clearly revealed when they are checked with certified weights. But perfect measurement of weights is not the application this balance was designed for. Sartorius high-capacity micro balances enable optimal minimum weights within the USP 41 operating range to be measured in heavy glass vessels, such as long-necked, volumetric flasks. Direct weighing of even the smallest quantities of a substance in large glass flasks enables straightforward, accurate and efficient preparation of stock solutions and reference standards, e.g., for HPLC analysis. This eliminates the need for transferring a micro sample from a weighing boat into a volumetric flask, which can result in errors. Weighing directly in a large container reduces both sample loss and contamination. This application requirement that a balance needs to meet poses an even greater challenge to its weighing technology. The reason is that the the smaller the sample quantities used, the greater the relative measuring errors become, and the larger the tare container size employed, the higher the influence of environmental conditions will be on weighing accuracy. To ensure high accuracy during weight measurements and excellent repeatability of the results, you need to observe certain basic rules and requirements. External environmental influences or improper handling can lead to inaccurate results or poor weighing performance, which are not caused by the balance.

Choose a Stable Weighing Table in a Quiet Place to Set Up Your Balance. 1. 2. 3. 4. 5. 6. 7. 1. The table should be solid-built and, whenever possible, be made of stone or synthetic stone. 2. Avoid causing the tabletop to sag or deflect even slightly; for example, never use it to prop up your arm. 3. Set up the balance in a vibration-free location. Ensure that there are no machines or engines that generate vibrations or electromagnetic fields near the balance. Magnetism must be ruled out (e.g., tables may not be made of stainless steel). 4. Do not position the table in the middle of the room, but near a wall or, even better, in the corner of a room, as this is where the vibration amplitudes are generally at their lowest. 5. Avoid exposing your balance to sunlight and infrared radiation emitted by lamps or heaters. 6. The location may only be slightly ventilated. Exposure to drafts needs to be avoided, and the air flow rate should be below 0.2 m/s. 7. Cold air currents from air conditioners may not pass directly across or over the draft shield, as this can result in an inversion layer of air inside the draft shield. This, in turn, can cause unstable weight readouts.

Work in the Lab under Consistently Constant Climate Conditions. 1. 4. >40% 2. 3. 1. Avoid significant temperature changes or spikes. 2. Keep the relative humidity as constant as possible. Prevent the relative humidity from dropping below 40%, as this will significantly increase interference by static electricity. 3. Use the Sartorius climate sensor option (temperature, barometric pressure and relative humidity) to monitor climate conditions. 4. Use the Sartorius ionizer option to eliminate electrostatic influences. Electrostatic charges on glass vessels dissipate only very slowly, particularly when these vessels have very clean surfaces, especially when they are used freshly from a laboratory glassware washer. Electrostatic influences are easy to detect by the continuous drift of weight readouts. Increase the air humidity to levels up to 60%, and use an ionizer to reduce these effects on the resulting weight readings.

Ensure That the Balance Is Leveled and Calibrated. isocal 1. 2. 1. Sartorius high-capacity micro balances will support you in using the calibration adjustment function isocal, and the Q-Level function implemented in the balance for leveling continuously maintains the accuracy of the weighing results within a narrow tolerance range. 2. Moreover, routinely check the balance using an external, certified weight.

During the Measuring Sequence, Ensure That 1. 2. 3. 4. 7. 5. 6. 8. 1. the vessels used are acclimatized next to your balance; i.e., have adapted to the temperature conditions in the same room. 2. you do not touch the container with your hands when positioning it on the weighing pan or in a sample holder. Touching the sample vessel with your hand usually increases the temperature of the vessel. Buoyancy and air current effects influence weighing results. Remember that it takes ten minutes for these effects to subside. Use a pair of tweezers or forceps to position the vessel. 3. Avoid placing your hand inside the draft shield to ensure that no unnecessary interchange of air outside and inside the draft shield takes place and that no heat is transferred into the draft shield. 4. Avoid touching a vessel with your bare fingers at all times, as a single fingerprint can weigh up to 50 μg and therefore have a major impact on the accuracy of your weight measurement result. 5. When weighing, ensure that no powder falls onto the weighing pan next to the vessel, as this will mean that the displayed sample weight is not what is actually in the vessel. 6. Avoid the complete interchange of air when opening the draft shield by opening only one door, where possible. Opt for using the draft shield learning capability to open the door only as far as actually necessary. 7. Carefully place the tare container on the weighing pan or in the sample holder. Avoid applying any excessive force. 8. Do not lean on or against the weighing table or rest your arm arm on it during the weighing procedure.

Contact Sartorius Lab Instruments GmbH & Co. KG Otto-Brenner-Strasse 20 37079 Goettingen Phone +49.551.308.0 Fax +49.551.308.3289 www.sartorius.com Specifications subject to change without notice. Copyright Sartorius Lab Instruments GmbH & Co. KG. Printed in the EU on paper bleached without chlorine. Publication No.: WL-1503-e170701 Order No.: 98649-023-48 Ver. 07 2017