Transferpette. Single and Multichannel Pipettes

Similar documents
Transferpette. Lightweight precise rugged reliable!

Transferpette. Lightweight precise rugged reliable!

Transferpette -8/-12

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

MULTICHANNEL. Labnet International, Inc.

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

Proline Plus Mechanical Pipette

DISCOVERY PRO - features

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

Transferpette -8/-12

Fisherbrand. Finnpipette INSTRUCTIONS FOR USE PARK LANE Pittsburgh PA

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

VITLAB micropipette. Standard Operating Procedure (SOP)

A N F G J I C D D L A B C D E F

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

PIPETMAN F ENGLISH. Other languages available on our website:

RayPette Plus Autoclavable Pipette. User Manual

Improving Pipetting Techniques

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

The pipettes cover a volume range from 0.1µl to 10ml.

CALIBRATION AND ADJUSTMENT

A N B P F G J I C D D L A B C D E F

Other languages available on our website:

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Pipettor. User Manual

User s Manual. Autoclavable & UV r e s i s t a n t. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Phone: Fax: More information:

Deadweight Tester / Pressure Balance High pressure up to 5,000 bar / 70,000 psi CPB5000-HP. Applications. Special features. Description. Rel.

Phone: Fax: More information:

Operating Instructions. Rainin Classic Manual Pipette

ali-q TM Gravimetric Verification Procedure

Register your instrument! Eppendorf Research plus. User Adjustment

NEO. User s Guide. Do not lubricate this pipette. The use of lubricant cancels the warranty of this pipette. NOTICE

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Pipetting and Determining Protein Concentration

Eppendorf Research fix variable multi Instruction Manual Bedienungsanleitung Mode d emploi Instruzioni d impiego Manual de Instrucciones

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

A N B P G J I C D L D E

SoCal BioMed, LLC 4695 MacArthur Court, 11th Floor Newport Beach, CA Phone: +1 (424) Fax: +1 (323)

INTERNATIONAL STANDARD

Nichipet EX Plus II. User s Manual. Autoclavable & UV resistant. Digital micro pipette for liquid handling

Good Pipetting Practice

Register your instrument! Eppendorf Xplorer / Eppendorf Xplorer plus. Adjustment

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

User s Guide VARIABLE VOLUME MODELS. Variable volume single and multichannel models and fixed volume models

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Pipetting Small Volumes

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

User s Manual. Autoclavable & UV resistant Nichipet EX II. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

MICROMAN ENGLISH. Other languages can be consulted and downloaded on our website,

Improve pipetting results in pharmaceutical formulation by using MICROMAN E

WITOPET PREMIUM PIPETTE USER S GUIDE

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

VWR HIGH PERFORMANCE PIPETTOR

Thermo Scientific F1-ClipTip Single Channel Multichannel

Using a micropipette to transfer exact liquid measurements in scientific experiments By: Nicole Hume

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

User s Manual. Digital micro pipette for liquid handling CERTIFIED ISO9001

Comfortable and Secure by Nature!

Qi Litre Ultrasonic Cleaner

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

Liquidator 96 Manual benchtop pipetting system

Tacta Mechanical Pipette User Manual

MOLEBIO LAB #1: Microquantity Measurement

SoftGrip Single Channel Pipettes User Manual New Photo To Come

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Chapter 2. Pipetting techniques. Guide to Pipetting

PERFORMANCE TEST INSTRUCTIONS FOR BIOHIT PROLINE PIPETTORS

Hydraulic hand test pump Models CPP700-H and CPP1000-H

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Hydraulic pressure balance Model CPB5800

Technology for Vacuum Systems Instructions for use

Sartorius Liquid Handling Products

Adjust the Volume Display

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

Varipette Operating manual

Peak Pressure Indicator MSI-3

VOLUMETRIC TECHNIQUES

The pipette of Choice for Problem Liquids!

SuperClear 15mL and 50mL Centrifuge Tubes

Pressure Calibrators. Series PC..., PM...

Biochemistry Laboratory I CHEM 4401 Pipetting & Scales

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

Userts Manual. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC) Annex III self-declared ISO 8655 STANDARD

Ergonomic Pipetting for Problem Liquids!

Dead-weight tester High-pressure version Model CPB3800HP

EC214 EC215 - EC215R Bench Conductivity Meters

Pipette Tips. Purity and Performance Rainin BioClean Ultra Tips Deliver

Technical Procedure for General Laboratory Equipment

High-Throughput. Faster, Better 96 & 384-Well Pipetting Ultra Efficient and Extremely Versatile

Measurements. Metric System

Design Features. General Description

Performance Verification of BioTek s Precision 2000 using Artel s Multichannel Volume Verification (MVV ) System

Transcription:

Transferpette Transferpette -8/-12 Transferpette Single and Multichannel Pipettes The Transferpette pipette from BRAND is designed for routine lab and research applications in a shape that is adapted to the anatomy of the human hand. The special handle shape with the side pipetting key allows the Transferpette pipette to lie loosely and lightly in your hand. The Transferpette models are particularly well suited for prolonged pipetting, or for anyone who is susceptible to RS syndrome due to repetitive laboratory procedures. www.brand.de 41

Transferpette Transferpette -8/-12 Models Economical accurate versatile: With only 5 instruments you can cover the entire volume range from 0.1 to 5 ml. You can choose from 10 models of the digital-adjustable Transferpette pipette and from 12 models of the fixed-volume type. There are 7 different multichannel pipettes available in the 0.5 to 300 volume range. Features Side pipetting key relieves strain; separate ejector function limits errors. Pipette shafts/manifold are entirely autoclavable at 121 ºC (2 bar), acc. DN EN 285. Transferpette Transferpette -12 Transferpette Digital adjustable models and Transferpette -8/-12 feature Easy Calibration technique readjustment without special tools (please see page 288 for further details). Corrosion-resistant piston and ejector Colored tip ejector caps indicate appropriate tips to use. Transferpette 0.1-1 maximum precision for molecular biology work, especially when pipetting enzymes. A variety of pipette stands for optimum storage of the Transferpette pipette CE- -compliant The microliter pipettes Transferpette 0.1-1 and Transferpette S 0.1-1 can be used to pipette the smallest volumes down to 0.1 with the highest precision. n these instruments, which work exclusively with BRAND nano-cap pipette tips, the air cushion is greatly minimized in order to attain the highest precision when pipetting. The smallest volumes of liquid can be taken up with good visibility, and positioned in a microcentrifuge tube, for example. 42 info@brand.de

Transferpette A Closer Look... The Transferpette pipette is designed to the shape of the human hand for maximum comfort. Pipetting key The side mounted pipetting key reduces hand fatigue, especially when performing serial pipetting operations. Volume adjustment Changing volume is easy without snagging gloves. Detents prevent inadvertent volume changes. Hand grip The textured housing ensures a firm grip, and is UV resistant. Easy Calibration Technique Calibration and adjustments according to SO 9001 and GLP are done within seconds. Tip cone The taper is designed to fit PLASTBRAND and most other leading manufacturers tips. Pipette shaft The slim shaft (autoclavable at 121 ºC) makes it possible to pipette in narrowest vessels without removing the tip ejector. Optimal performance will be achieved with the use of genuine PLASTBRAND premium tips. Pipette and filter tips, see pages 83-90. www.brand.de 43

Transferpette Ordering Data Ordering Data Transferpette, Digital adjustable tems supplied: Each Transferpette Digital adjustable pipette is conformity certified and supplied with performance certificate. Subdivision 0.1-1 2 0.02 1.2 0.012 0.005 A, 7041 01 0.5-10 1 0.1 0.8 0.08 0.05 A, B, ***, J 7041 02 2-20 0.8 0.16 0.4 0.08 0.1 A, B, J*** 7041 03 2-20 0.8 0.16 0.4 0.08 0.1 C, D, K, L 7041 04 5-50 0.8 0.4 0.4 0.2 0.1 C, D, K***, L 7041 72 10-100 0.6 0.6 0.2 0.2 0.1 C, D, K***, L 7041 74 20-200 0.6 1.2 0.2 0.4 1 C, D, K***, L***, M 7041 78 25-250 0.6 1.5 0.2 0.5 1 E, F 7041 76 100-1000 0.6 6 0.2 2 1 E, F, N 7041 80 500-5000 0.6 30 0.2 10 10 G 7041 82 Transferpette, Fixed volume tems supplied: Each Transferpette Fixed volume pipette is conformity certified and supplied with performance certificate and calibration key. 5 1 0.05 0.8 0.04 C, D, K, L 7041 06 10 1 0.1 0.8 0.08 C, D, K, L 7041 08 20 0.8 0.16 0.4 0.08 C, D, K, L 7041 16 25 0.8 0.2 0.4 0.1 C, D, L 7041 20 50 0.8 0.4 0.4 0.2 C, D, L 7041 28 100 0.6 0.6 0.2 0.2 C, D, L 7041 38 200 0.6 1.2 0.2 0.4 C, D, M 7041 44 200 0.6 1.2 0.2 0.4 E, F 7041 46 250 0.6 1.5 0.2 0.5 E, F 7041 48 500 0.6 3 0.2 1 E, F, N 7041 54 1000 0.6 6 0.2 2 E, F, N 7041 62 2000 0.6 12 0.2 4 G 7041 64 * Calibrated to deliver (TD, Ex). Error limits according to the nominal capacity (= maximum volume) indicated on the instrument, obtained with instrument and distilled water at equilibrium with ambient temperature at 20 C, and with smooth, steady operation. The error limits are within the limits of DN EN SO 8655-2. Conformity certified to DN 12 600. A = Accuracy, CV = Coefficient of variation ** See page 56 for the definition of the tip types. *** Tip volume less than pipettes nominal volume BRAND also offers an on-site calibration service (for more information, please see page 291). Note: When ordering instruments with DKD certificates, the prefix 'DKD' must be added to the order number, e.g., DKD 7041 01. 44 info@brand.de

Transferpette Accessories Accessories (Other accessories and spare parts can be found in the operating manual.) PipSet Transferpette Digital adjustable The PipSet contains of three Transferpette pipettes (0.5-10, 10-100, 100-1000 ), one bench-top rack and one filled Tip Box N for each Transferpette pipette. 7041 90 Pipetting keys, colored For Transferpette and Transferpette -8/-12 pipettes. ncl. 2 stickers per key. Pack of 5. Color light green 7040 70 pink 7040 71 blue 7040 72 beige 7040 73 dark gray 7040 74 assorted colors 7040 75 Bench-top rack ncl. 1 or 2 adapters for Transferpette pipettes 2 ml or 0.5-5 ml. Description for 1 x 3 Transferpette pipettes 7032 03 for 2 x 3 Transferpette pipettes (Rondell) 7032 08 Wall/rack mount Description for 1 x 3 Transferpette pipettes* 7032 10 * Not suitable for the 0.5-5 ml or 2 ml Transferpette ndividual stand For Transferpette pipettes 0.5-5 ml, 2 ml and Transferpette electronic pipettes 0.5-5 ml. 7053 86 Filter For Transferpette 0.5-5 ml pipettes. Pack of 25. 7046 52 www.brand.de 45

Transferpette -8/-12 A Closer Look... The effortless ease of operation and its unique ergonomic shape make working with the Transferpette -8/-12 piston-operated pipette so comfortable. The use of high-quality materials makes it exceptionally light in weight, while special FKM V-rings and the stepped shape of the ejector significantly reduce the ejection force needed. Your hand remains relaxed and loose, even during a prolonged pipetting operation. Pipetting key The side mounted pipetting key helps to reduce hand fatigue, especially when performing serial pipetting operations. Volume adjustment Changing volumes is easy without snagging gloves. Detents prevents inadvertent volume changes. Hand grip The textured housing ensures a firm grip, and is UV resistant. Easy Calibration Technique Calibration and adjustments according to SO 9001 and GLP are done within seconds. Manifold Autoclavable at 121 C and freely rotated over 360º to adapt to your most comfortable pipetting position. Stepped tip ejector The stepped tip ejector ensures a tight tip seal with minimal tip ejection force. Tip cone The taper is designed to fit PLASTBRAND and most other leading manufacturers tips. ndividual shafts and seals can easily be replaced in the laboratory. 46 info@brand.de

Transferpette -8/-12 Ordering Data Ordering Data tems supplied: Each Transferpette -8/-12 pipette is conformity certified and supplied with performance certificate, 1 Tip-Box, filled with PLASTBRAND pipette tips, 1 Tip-Rack for refilling, 1 stand, 1 reagent-reservoir, 1 set of sealing rings made of FKM. Transferpette -8 Subdivision 0.5-10 1.6 0.16 1.0 0.1 0.05 A, B, ***, J 7036 00 2-20 1.0 0.2 0.6 0.12 0.1 A, B, J*** 7036 02 2.5-25 1.0 0.25 0.6 0.15 0.1 C, D, K***, L, M 7036 04 5-50 0.8 0.4 0.4 0.2 0.1 C, D, K***, L, M 7036 06 10-100 0.8 0.8 0.3 0.3 0.1 C, D, K***, L, M 7036 08 20-200 0.8 1.6 0.3 0.6 1 C, D, K***, L***, M 7036 10 30-300 0.6 1.8 0.3 0.9 1 C***, D, L***, M*** 7036 12 Transferpette -12 Subdivision 0.5-10 1.6 0.16 1.0 0.1 0.05 A, B, ***, J 7036 20 2-20 1.0 0.2 0.6 0.12 0.1 A, B, J*** 7036 22 2.5-25 1.0 0.25 0.6 0.15 0.1 C, D, K***, L, M 7036 24 5-50 0.8 0.4 0.4 0.2 0.1 C, D, K***, L, M 7036 26 10-100 0.8 0.8 0.3 0.3 0.1 C, D, K***, L, M 7036 28 20-200 0.8 1.6 0.3 0.6 1 C, D, K***, L***, M 7036 30 30-300 0.6 1.8 0.3 0.9 1 C***, D, L***, M*** 7036 32 * Calibrated to deliver (TD, Ex). Error limits according to the nominal capacity (= maximum volume) indicated on the instrument, obtained with instrument and distilled water at equilibrium with ambient temperature at 20 C, and with smooth, steady operation. The error limits are within the limits of DN EN SO 8655-2. Conformity certified to DN 12 600. A = Accuracy, CV = Coefficient of variation ** See page 56 for the definition of the tip types. *** Tip volume less than pipettes nominal volume Accessories (Other accessories and spare parts can be found in the operating manual.) ndividual stand For 1 Transferpette -8/-12 or 1 Transferpette S -8/-12 pipette. 7034 40 Reagent reservoir, PP, non-sterile or sterile, please see page 55. www.brand.de 47