Solaris Nitrogen. Installation Guide. Solaris Nitrogen Installation Guide Rev 1 PN IG /09/16

Similar documents
Precision Hydrogen (All B&W Screen Models)

Solaris Nitrogen. User Manual. Solaris Nitrogen User Manual Rev 1 PN UM /09/16

Genius 1022, 1023 & NM32LA (All Models)

Genius 3051 & User Manual. Genius User Manual Rev 1 PN UM /05/16

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Genius 3010 User Manual

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Your local gas generation partner. Precision series Modular gas generation solution for GC.

New AQF Filter Polymer Filtration System

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Digital Melting Point Apparatus

KMW3000C. User Manual. Water Chiller for Xcalibur and Gemini systems. Version 1.6, September 2010

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Your local gas generation partner. Gas Generators For Shimadzu Instruments. Discover more at

AR740 RPS Redundant Power Supply Quick Install Guide

Gas Generators AB Sciex Range

700 SERIES BMS II BUBBLER MONITORING SYSTEM

DTG - LCD Digital Temperature Gauge USER MANUAL

! Warning, refer to accompanying documents.

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

Siphon vessel / Priming aid

XpressFill XF4500 Counter Pressure Filler. Operating Instructions

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

Model 106 DPI "Micro-switch" Installation and Operating Instructions

Marschalk Model # 94000

DPC-30 DPC-100. Reference Manual

AB-3G User Manual Peak Scientific - Rev. 6A 15/09/15

PROCESS ANALYSERS. SERVOPRO PureGas. Gas Purifier. Operator Manual. Part Number: A Revision: 0 Language: UK English

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

DEEPSEA. SeaLite Lumos POWER & LIGHT. Operator s Manual Ruffin Road San Diego, CA USA.

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

DEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA

XpressFill XF4500C Counter Pressure Can Filler. Operating Instructions

OPERATION & MAINTENANCE MANUAL NG6/1 YOUR RELIABLE PARNTER IN LABORATORY GAS HANDLING

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

490 Micro GC Site Preparation Checklist

USER MANUAL. MACMAG magnetic separator MHK MHF

Temperature Controllers

Installation, operating and maintenance Instructions for Seemag bypass level indicator

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

RTD Temperature sensor TH11

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

STAGE, STADIUM & X-TREME SHOT.

Your local gas generation partner. Gas Generators. For Thermo Scientific Instruments. Discover more at

Norrsken Family Booklet

92831 TEL: (714) FAX:

Pressure Automated Calibration Equipment

KJ1000 Operating Instructions & Parts Manual NSN

Operating Instructions Part No

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Instructions for High Altitude Conversion

Setup Guide for your HVO Naked Drone

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Sample Concentrator SBH CONC/1 Instructions for use

C1960. Multi-recipe profile recorder/controller. Measurement made easy

Laser Cutting. Nitrogen Solutions for

Propane Conversion Kit Instructions

Your local gas generation partner. Pocket Guide Discover more at

NovelBright LED Illuminator

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

Operating Manual VSA100A. tina29e1 ( )

Conversion instructions from natural gas to propane

MP15 Jockey Pump Controller

RPS900W Redundant Power Supply. Installation Guide.

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

Section 3- Repair and Calibration Procedures

Instrument Operating Manual

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

Peak Pressure Indicator MSI-3

ST53SD. Self Contained Breathing Apparatus. User Manual

UltraLo 1800 Alpha Particle Counter

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

OPERATION MANUAL NTF-15

Float Operated Level Controllers

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

Spirax Compact FREME Flash Recovery Energy Management Equipment

/2004 US/CA

SILENTAIRE TECHNOLOGY

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA

WHEATLEY Series 500 Swing Check Valve

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

AE R1 February 2015

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on)

In Vivo Scientific, LLC INSTRUCTION MANUAL

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

92831 TEL: (714) FAX:

12V Mini Air Compressor

Mini Pod Press. #78H-M2 Mini Pod Press Manual-R1

9101 Zero Point Dry-Well

Unit 24: Applications of Pneumatics and Hydraulics

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Transcription:

Solaris Nitrogen Installation Guide Solaris Nitrogen Installation Guide Rev 1 PN IG-0014 01/09/16

Change History Rev Comment Name Date How to use this Manual This installation guide is intended to be used as a step by step, quick start guide, to facilitate installation and configuration. Please visit www.peakscientific.com/downloads to download the full User Manual for your gas generator. Thank you for selecting Peak Scientific to meet your Gas Generation needs, and should you require any further assistance or support please do not hesitate to contact Peak Scientific or Peak Partner from which you purchased your Generator. Page 2

Safety Notices Peak Scientific Instruments cannot anticipate every possible circumstance which may represent a potential hazard. The warnings detailed within this document detail the most known potential hazards, but by definition cannot be all inclusive. If the user employs an operating procedure, item of equipment or a method of working which is not specifically recommended by Peak Scientific, the user must ensure that the equipment will not be damaged or become hazardous to persons or property. Symbols This document uses the following symbols to highlight specific areas important to the safe and proper use of the Generator WARNING CAUTION A WARNING notice denotes a hazard. It calls attention to an operating procedure, process or similar, which if not correctly performed or adhered to, could cause personal injury or in the worst case death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood or met. A CAUTION notice denotes a hazard. It calls attention to an operating procedure, process or similar, which if not correctly performed or adhered to, could cause damage to the Generator or the Application. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood or met. Caution, risk of electric shock. Ensure power to the Generator has been removed before proceeding. Safety Notice to Users WARNING WARNING WARNING These instructions must be read thoroughly and understood before installation and operation of your Peak Solaris Nitrogen Generator. Use of the Generator in a manner not specified by Peak Scientific MAY impair the SAFETY provided by the equipment. When handling, operating or carrying out any maintenance, personnel must employ safe engineering practices and observe all relevant local health and safety requirements and regulations. The attention of UK users is drawn to the Health and Safety at Work Act 1974, and the Institute of Electrical Engineers regulations. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Page 3

Fittings Kit x1 US Mains Cable C13 6-15 04-1029 x3m 1/4 Teflon Tubing 00-1266 x1 US Mains Cable C13 5-15 04-1039 x1 UK Mains Cable C13 04-1028 x1 1/4 x 1/4 Compression Fitting 02-4421 x1 EU Mains Cable C13 04-1038 Page 4

1. WARNING 0 Unpack the generator from the shipping crate and position on a flat surface, in desired area. WARNING the weight of the unit contitutes a two man lift. Safe lifting practices are advised. 2. 02-4421 Select the ¼ x ¼ Compression Fittings and attach to the AIR IN and NITROGEN ports. Page 5

3. 00-1266 Copper / Stainless Steel tubing only Connect the supplied ¼ Teflon Tubing to the AIR IN port. Connect appropriate ¼ tubing, greater than 1m in length, to the generators NITROGEN port. Please note: Only Copper or Stainless Steel tubing should be connected to the NITROGEN port. 4. CAUTION 04-1028/04-1029/04-1038/04-1039 Select the appropriate mains cable from the fittings kit and plug the IEC 60320/C13 cable into the mains input at the rear of the generator. Please note both 110V and 230V US cables have been supplied, select the correct mains cable for your supply voltage. Page 6

5. UK EU CAUTION US 110V US 230V 6. 100-230VAC 50/60Hz Plug the mains cable into the corresponding 100-230VAC 50/60Hz single phase power supply. CAUTION ensure the correct cable has been selected for your electrical supply Press the POWER switch located at the rear of the generator. Page 7

7. YELLOW The LEDs on the front of the generator should now illuminate YELLOW as the unit starts up. 8. GREEN The LEDs will illuminate GREEN to indicate that the generator is now ready to use. Page 8

9. / CONGRATULATIONS Your Peak Scientific gas generator is now fully installed, operational and ready to supply gas on demand to your instrument. Page 9

General Notes Electrical requirements are 100-230VAC nominal +/- 10% depending on chosen model. However, running continuoulsy at voltages outwith this is not recommended. Extended periods at extremes can have a detrimental effect on the operation and life of the Generator. Please familiarise yourself with the full User Manual available at www.peakscientific. com/downloads This includes all other technical specifications, operating instructions, service requirements, contact details and trouble shooting. If you are using the Solaris Air Compressor as your air supply, please refer to the Solaris Air Compressor Installation Guide, available at www.peakscientific.com/ downloads Page 10

Go Online or Complete and Return We know that registering any of your recently purchased products is not the first thing on your mind- but it is very important to both of us. Not all warranties are alike and Peak Scientific stand out against other gas suppliers as we offer a comprehensive on-site warranty. This means that in the very unlikely case that your gas generator develops a fault we have rapid support teams on-hand throughout the globe who are able to come to your lab and get you back up and running in no time. Register for your comprehensive 12 month on-site warranty with ease online at www.peakscientific.com/protected. Alternatively, you can send the completed form to Peak Scientific by post or email at warranty@peakscientific.com. Go Online or Complete and Return You can register for your FREE 12 month Warranty with ease online at www.peakscientific/protected. Alternatively, you can send the completed form to Peak Scientific by post or email at warranty@peakscientific.com. Product Warranty Registration Contact name Email address Company Address City/town Postcode Country Telephone Generator serial # Model type Installation date Do you still use an alternative gas solution i.e. Yes No cylinders or bulk liquid? What gas requirements do Hydrogen Nitrogen Zero Air you have in your lab? Extend your cover with Peak Scientific offer comprehensive gas generator after sales support packages. Peak [Protected] aftercare support can guarantee an on-site response within 72 hours*, genuine parts from our ISO9001 approved factory and a 95% first-time fix rate. See our enclosed Peak [Protected] leaflet for further information. Important! You have 1 month to register your Peak Scientific product from the date of installation. Once registered the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your generator, you must notify Peak Scientific immediately by emailing warranty@peakscientific.com. For generators that remain unregistered after 1 month from the shipment date, the warranty will be considered active from the date of factory dispatch. * Complete Plan only Important! You have 1 month to register your Peak Scientific product from the date of installation. Once registered the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your generator, you must notify Peak Scientific immediately by emailing warranty@peakscientific.com For generators that remain unregistered after 1 month from the shipment date, the warranty will be considered active from the date of factory dispatch. Page 11

Please visit www.peakscientific.com/downloads to download the full User Manual for your gas generator. Peak Scientific has highly trained, fully certified Field Service Engineers located in over 20 countries across every continent around the world. This allows us to provide an industry-leading rapid response service to our customers. With [Peak Protected], your laboratory s productivity becomes our top priority. To discuss Peak Protected generator cover and payment options speak to your local Peak Representative or for further information contact: protected@peakscientific.com Peak Scientific Fountain Crescent Inchinnan Business Park Inchinnan PA4 9RE Scotland, UK Tel: +44 141 812 8100 Fax: +44 141 812 8200 For further information on any of our generator products please contact marketing@peakscientific.com Solaris Nitrogen Installation Guide Rev 1 PN IG-0014 01/09/16