Circuit model of medical equipment for electrical safety purposes

Similar documents
CHAPTER 2: ELECTRICAL SAFETY

Guidelines to the standard IEC60601

5 th year (Control department)

INSPECTION OF MEDICAL DEVICES

Electrical Safety in Hospitals

Leakage Current Testing Is it right for your application?

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Inspection and Testing

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

PERIODIC INSPECTION REPORT FOR AN ELECTRICAL INSTALLATION

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations

Sikkerhed og certifisering for sundhedsteknologisk udstyr

Installation, use and maintenance instructions. Gas burner (5)

UL TEST REPORT AND PROCEDURE

COVER PAGE FOR TEST REPORT

Inspection and Testing Pocket Notes

Technical Data. General specifications. Rated operating distance s n 5 mm

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Please print or type all responses except where a signature is required. DESIGN PROJECT TITLE: SEMESTER AND COURSE REFERENCE NUMBER: STUDENT NAME:

Dealing with Electrical Hazards in the Workplace

Reference Number PDS 10 (RIC Standard: EP SP)

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Advanced Test Equipment Rentals ATEC (2832) OMS 600

Operating instructions Pressure sensor. PN422x / / 2013

Experiment Instructions. Circulating Pumps Training Panel

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Covered Task 409OP Training Guide Inspecting Interference Bonds

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Electrical Safety. Toolbox Talk

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

82C288 BUS CONTROLLER FOR PROCESSORS (82C C C288-8)

Technical Data. Dimensions

! Warning, refer to accompanying documents.

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

Ground Fault Circuit Interrupter(GFCI) Policy

Department of Electrical Engineering & Computer Science. Electrical Safety. for Staff and Students in EECS Instructional Laboratories

Welding With Arc Welding Equipment

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

SEMEEE3-34 Carrying out functional tests on electrical equipment

DETRMINATION OF A PLUNGER TYPE WAVE MAKER CHARACTERISTICE IN A TOWING TANK

Respiration. Figure 22: Schematic representation of the respiratory system

KMU SUBSTATION WORKSHOP

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certifi cate of Secondary Education

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Key Comparison of Safety Requirements in Europe, North America and Australia for Electronic Products

RESTORATION OF HEART RHYTHM DURING FIBRILLATION BY A CONDENSER DISCHARGE

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

MECA Ed3.1 Evaluation Package BETA, Through Cl ( ) Page 1 of 65

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES

It is essential that the maintenance staff is qualified for electrical works and follows safety procedures.

This training session covers electrical safety for unqualified persons. Unqualified persons are machine operators, operators of powered industrial

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Effect of a Backplate Using in Electromagnetic Induction Method for Permittivity Measurement

Technical Data. General specifications. Rated operating distance s n 2 mm

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

Technical Data. Dimensions

Electrical. OSHA Office of Training and Education 1

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17

DX 3 RCDs. Technical data Nature and consequences of electrical risks Direct and indirect contact. Direct contacts

OWNER S MANUAL NMB SERIES

Recent changes in workplace safety regulations have heightened the awareness of hazards associated with electrical arcs.

Prewired position switches FA series

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

Circuit breakers PR 60

Gas density monitor With integrated transmitter Model GDM-100-TI

Guidance and history. Why MEIGaN? Medical Locations & Healthcare Electrics Part 1

Safety Manual VEGAVIB series 60

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Availability analysis of railway track circuit

STH Pump Controller Owner s Guide

ES18 Security Theory/Regulations Answer Schedule

Technical Data Sheet MF010-O-LC

PECIMEN IMM6. Minor Electrical Installation Works Certificates. Amd 3: In accordance with BS 7671

Distributed Control Systems

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)

Elimination of Oil Residual inside the Copper Pipe Using Ladder Technique

MIL-STD-883G METHOD

REFERENCE SPECIFICATION

SESI SMD Power Inductors and Transformers

Type 761M. Axial Lead Pressed/Oval Profile. Metallized Polypropylene Film Capacitors. Type 761M. Specifications

Definitions found in several locations:

IEC Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Proficiency with Zoll in Manual Mode: There is a new Dashboard screen that you will see on the Zoll while in manual mode

Prewired position switches FA series

TEST REPORT EN Degrees of protection provided by enclosures (IP Code)

Technical Data. Dimensions

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

By: Bruce Bowman, P.E.

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Safety Manual VEGAVIB series 60

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Ultima. X Series Gas Monitor

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

Installation, operating and maintenance Instructions for Seemag bypass level indicator

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

70e Training - Electrical Safety in the Workplace

Operating Instructions for Manometer. Model: MAN

Transcription:

Risk Analysis IX 507 Circuit model of medical equipment for electrical safety purposes E. Zennaro 1, C. Mazzetti 1, F. Fiamingo 2 & G. L. Amicucci 2 1 Department of Astronautics, Electrical and Energetics Engineering (DIAEE), Sapienza Università di Roma, Italy 2 Department of Safety Technologies (DTS), Istituto Nazionale per l Assicurazione contro gli Infortuni sul Lavoro (INAIL), Italy Abstract In order to assess the risk of electric shock during a surgical procedure, it s important to know the insulation paths and the values of the insulation impedances of Medical Electrical (ME) equipment and then to draw leakage circuits and monitor the intensity of leakage currents. The aim of this work is to propose a circuit based model of a ME equipment to simulate the leakage currents measured during electrical safety tests. The setup of these measures are described in the standard EN 60601-1, which also describes the insulations composing a ME equipment and where they are placed. While the standard EN 62353 describes the insulation resistances should be measured. This information is the references for the model development which is subsequently implemented with the circuit simulation software National Instruments Multisim. The application of the circuit model allows the simulation of an earth leakage current, touch current and patient leakage current similar to real equipment, both in normal and in single fault conditions. The values of the electrical parameters of the model from a measurement report of a commercial defibrillator are assigned. The results of circuit model leakage currents are compared with the measurement data. The output of this comparison may be considered quite satisfactory. In this paper the extension of the model to other ME equipment is also discussed in view of the assessment of the risk of electrical shock during a surgical procedure. Keywords: microshock risk, medical equipment, circuit model of the defibrillator, floating type applied part, risk analysis, electrical safety. doi:10.2495/risk140431

508 Risk Analysis IX 1 Introduction Healthcare facilities are critical infrastructures where safety of patients and medical operator must be ensured. The mutual relationship between the ME equipment, the patient, the health personnel and the related environment needs to be carefully considered because of the health status of the patient. In some medical procedures, low current is sufficient to cause respiratory paralysis ( 10 ma) or potentially fatal ventricular fibrillation ( 20 ma). The low resistance pathway via skin penetration and the decreased patient defences because of anesthesia, increase the risk of electric shock under faulty condition, as reported by Amicucci et al. [1]. For the purpose of risk analysis in a surgical room information is required about the power system installed into the medical structure, as well as technical data of ME equipment. But the leakage currents from every ME equipment used during the surgical procedure, the values of their insulation impedances and the insulation paths through which currents flow, are often not available. The standard ISO/DIS 13824 [2] considers the use of engineering models to estimate the risk of a system where data are lacking. Corbellini [3] suggested the use of software for the simulation and modelling. Spalding et al. [4] shows an electrical model of a ME equipment supplied from an IT-M distribution system to explain how detect and measure the microshock risk by computer simulations and hardware equipment. In this paper a novel approach is presented to evaluate the leakage currents from real ME equipment tested in accordance with standards CEI EN 60601-1 2 nd ed. [5] and CEI EN 62353 [6]. In particular the layout and the electrical parameters values of the circuit model are presented. 2 Circuit model The two last editions of standard CEI EN 60601-1 [5, 7] have constituted the key publications of reference for modelling the circuit shown in Fig. 1. The older edition of such standard specifies the construction details, as the type of insulation and where this should be placed. While the newer edition specifies the limit values of leakage currents and specifies the measurement set-up to evaluate whether they are exceeded from the equipment under test. Moreover standard CEI EN 62353 [6] is also important to understand how many insulations should be calculated for the leakage current estimation. It requires that insulation resistance shall be measured at voltage of 500 V dc between: a) the mains part and protective earth for class I equipment; b) the mains part and (non-earthed) accessible conductive parts for class I and class II equipment; c) the mains part and the applied parts; d) floating type applied part and protective earth for class I equipment; e) floating type applied part and (non-earthed) accessible conductive parts for class I and class II equipment.

Risk Analysis IX 509 During the operation, the frequency of electrical equipment is equal to 50 Hz in Europe and insulation should be modelled with an ohmic-capacitive parallel impedance. In fact when frequency is not null, capacitance ( insulation capacitance in the paper) reduces impedance and increases current that flow over the equipment through the earth or the patient. L1 MP 1 Rp1 AP R_i2 C_i2 R_i1 C_i1 V1 C1 Cp1 230 Vrms R_i3 Rp2 50 Hz R1 M 0 C2 I C_i3 PE Cp2 Rp3 R_i4 C_i4 R_i5 C_i5 L2 Cp3 MP 2 Figure 1: Electrical circuit model of the generic ME equipment with floating (F) type applied part. Fig. 1 shows the phase-neutral with floating (F) type applied part circuit model of a generic ME equipment. It follows the explanation of the circuit parameters: MP: mains part or alive part; I: enclosure; M: ground; AP: applied part; L1: supply phase L1 (one of the two alive parts); L2: supply phase L2 (the other of the two alive parts); V1: root mean square value of the supply voltage of the ME equipment. The value is equal to 230 V and the frequency is equal to 50 Hz; C1, C2: electromagnetic interference (EMI) filter capacitances; R1: ME equipment resistive load which absorbs electrical power; Ri1, Ci1 and Ri5, Ci5: basic insulation between alive parts and conductive accessible parts that are protectively earthed (named ground in the paper); Ri2, Ci2 and Ri4, Ci4: double insulation or reinforced insulation between alive parts and conductive accessible parts non-protectively earthed (named enclosure in the paper), for example moving parts for

510 Risk Analysis IX which PE connection is not recommended due to its poor reliability (in general for class II equipment); Ri3, Ci3: insulation between ground and enclosure. It is indicated in [5] that this insulation would be in addition to the insulations interposed to alive parts; Rp1, Cp1 and Rp2, Cp2 and Rp3, Cp3: insulations between applied part and one of the two supply phases, applied part and conductive accessible part, applied part and the other of the two supply phases respectively. The circuit model described in Fig. 1 allows us to simulate leakage currents similar to that of a real equipment. It has been successful applied in the case of a commercial defibrillator. In Fig. 2 the electrical diagram of commercial defibrillator for electric safety measurements in an Italian hospital is presented. The diagram is drawn on the software platform National Instruments Multisim, which is particularly suitable to perform simulations. The commercial defibrillator under test is a class I ME equipment, with a basic insulation between alive parts and ground. Touch current values measured during tests shows that all conductive accessible parts are protectively earthed. The defibrillator is composed by three cardiac floating (CF)-type applied parts and two body floating (BF)-type applied parts. The CF-type applied parts are ElectroCardioGraphic (ECG) electrodes ( electrodes in the paper) and the BF-type applied parts are paddle electrodes ( paddles in the paper) from which the electrical discharge is delivered. Fig. 2 shows the Measuring Device (MD) that is modelled as reported in [7] where the resistance of 1 kω represents the human body. So this circuit models a specific defibrillator put into operation on a laboratory bench to test earth leakage current, touch current and patient leakage current. These currents are measured in: normal condition (NC); when a supply conductor or the protective earth conductor are open (single fault conditions SFC); both with normal supply polarity and reversed supply polarity. Defibrillator has not been placed in an operating room, where other electrical equipment as insulation transformers, supply lines, etc. would be modelled in addiction. In Fig. 2 switches J1 and J3 are shown. They are drawn to simulate the inversion of supply polarity. Switch J2 is drawn to simulate disconnection of one supply phase while switch J4 simulates the disconnection of PE. The insulation between applied parts and alive parts can be double, or composed by basic insulation + secondary circuit protectively earthed, basic insulation + metallic shield or by impedances. The insulation between applied parts and conductive accessible parts can be solid considering creepage distances, or air considering air clearance. Values of impedance and capacitance have been calculated by means of formulas (1), (2), (3) and (4). Resistance values are assigned by measurement tests listed in [6] and written as a), b), c), d) and e) at the beginning of this section. The EMI filter capacitance is assigned equal to 1 nf which is a reasonable value and its variations don t influence the results of the model.

Risk Analysis IX 511 J1 R_i1 C_i1 R3 150MΩ Alive Part MP1 401MΩ 3.76nF Key = Space 12pF V1 C3 C1 R5 1nF 150MΩ 230 Vrms R1 50 Hz 1150Ω Ground 0 900pF C2 C5 J2 J3 1nF R13 2GΩ 22pF C13 Key = A Key = Space Alive Part MP2 401MΩ 3.73nF R18 R_i4 C_i4 R6 155MΩ J4 20kΩ R2 13pF C6 Key = B 0.055Ω Protective Earth R7 155MΩ C7 900pF R_MD R14 2GΩ 1kΩ 22pF R_in_md C14 R8 600MΩ 10kΩ 0.015µF C8 1.64pF C_md R4 220MΩ MEASURING DEVICE C4 53.4pF R15 600MΩ C15 1.64pF R9 600MΩ C9 1.64pF R10 220MΩ C10 53.4pF R16 600MΩ C16 1.64pF R11 600MΩ 1.64pF C11 R12 230MΩ C12 53.6pF R17 600MΩ C17 1.64pF Earth Figure 2: Electrical safety based circuit model of a commercial defibrillator. BF type AP 1 BF type AP 2 CF type AP 1 CF type AP 2 CF type AP 3

512 Risk Analysis IX Z 1 1 R R 1 jcr jc R 1 jcr 1 jcr 1 jcr R j 1 1 CR 2 2 CR CR 2 (1) 2 2 R CR Z 2 2 1 ( CR) 1 CR Z V I 2 (2) rms (3) rms C The parameters of the circuit model are shown in Table 1. It is important to note that insulation resistances between applied parts and alive parts are not measured during tests. Their values in the model are assigned on the basis of the leakage currents measured taking into account the accuracy range of the MD: 1% of read value ± 1μA. 3 Results 2 2 2 2 4 2 2 2 2 4 2 4 4 2 2 2 2 Z R R 2 Z R R 4 R Z Z R 1,2 4 4 2 2 R Z The circuit model results of leakage current are compared with the measurement data obtained from tests carried using a commercial defibrillator. It is important to note how the data returned by the model are in line with what was expected. In fact, the earth leakage current, the touch current and the patient leakage currents which flow through the circuit in single fault conditions are greater than those found in normal condition. While the measurement data show that there is no difference in the values of touch current and the patient leakage currents when a supply conductor is open compared to the normal condition. The range accuracy of the MD justifies the difference between the experimental data and simulated ones. As it can be noticed, the simulated patient leakage currents from the paddles when a supply conductor is open are not twice the same currents in normal condition as it happen for the simulated patient leakage currents from the (4)

Risk Analysis IX 513 electrodes. Moreover, the values of these currents are slightly different when the polarity is reversed. The asymmetry values of the insulation impedances of the paddles with respect to the two alive parts, justifies this difference shown in the Table 2. Table 1: Comparison between electrical parameter values measured on a commercial defibrillator and simulated ones. Electrical parameter Real defibrillator Simulated defibrillator Load resistance 1150 1150 PE 0.055 0.055 Basic insulation resistance Basic insulation capacitance LL pad insulation LL pad insulation LL pad insulation LL pad insulation V pad insulation resistance with respect to V pad insulation V pad insulation resistance with respect to the alive parts V pad insulation RA electrode insulation RA electrode insulation RA electrode insulation RA electrode insulation OVER (> 400 M maximum of the MD measurement range) 401 M 3.76 nf with respect to the phase L1 3.73 nf with respect to the phase L2 150 M 150 M 900 pf 150 M with respect to L1 2 GΩ with respect to L2 12 pf with respect to L1 22 pf with respect to L2 155 M 155 M 900 pf 155M with respect to L1 2 GΩ with respect to L2 13 pf with respect to L1 22 pf with respect to L2 220 M 220 M 53.4 pf 600 M with respect to the alive parts 1.64 pf

514 Risk Analysis IX Table 1: Continued. Electrical parameter Real defibrillator Simulated defibrillator RL electrode insulation 220 M 220 M RL electrode insulation 53.4 pf RL electrode insulation 600 M with respect to the alive parts RL electrode insulation 1.64 pf LA electrode insulation 230 M 230 M LA electrode insulation 53.6pF LA electrode insulation LA electrode insulation 4 Conclusions 600 M with respect to the alive parts 1.64 pf In this work we have shown the circuit model of a real ME equipment suitable for assessment of microshock risk. The model contains all insulation resistances that are considered in standards CEI EN 60601-1 and CEI EN 62353. Values of model parameters may be obtained from electrical safety tests on the considered ME equipment and by simple application of Ohm s law, which allow to calculate resistances and capacitances that constitute insulation impedances. The model simulates leakage currents from ME equipment in normal condition and in single fault conditions. It has been validated by the application to a commercial defibrillator and results of simulated leakage currents are to be considered in quite satisfactory agreement taking into account the accuracy range of the MD used for tests. The method presented to construct the circuit model of a ME equipment can be extended to draw the safety based model of any other ME equipment by assigning the values of insulation impedances from the results of laboratory tests, required by the regulations. In fact, even if ME equipment are physically much different, they must comply with the requirements of the standards. So, the model of each of the equipment is composed by insulations which are to be measured as is written in [6] and its leakage currents must comply with limit values as is reported in [7]. This does not exclude that in constructing the circuit model of a ME equipment is necessary to take into account its own

Risk Analysis IX 515 particularities, for example the class of the electrical equipment or the number and the type of applied parts. The modelling of ME equipment used in a surgical procedure is important to assess the risk of microshock in the operating room. Table 2: Comparison between leakage current values measured during the electrical safety tests on a commercial defibrillator and simulated values from its electrical circuit model. Device s component Operating condition PE Earth leakage current in normal condition PE Earth leakage current when a supply conductor is open PE Earth leakage current in normal condition and supply PE Earth leakage current when a supply conductor is open and supply Touch current in normal condition Touch current when a supply conductor is open Touch current when PE is open Touch current in normal condition and supply polarity reversed Touch current when a supply conductor is open and supply Touch current when PE is open and supply polarity reversed Patient leakage current in normal condition Patient leakage current when PE is open Patient leakage current in normal condition and supply and supply Patient leakage current when PE is open and supply Patient leakage current in normal condition Measured value [μa] Simulated value [μa] 274 274 522 518 273 273 525 518 0 0.015 0 0.03 270 274 0 0.015 0 0.03 273 273 2 2.23 2 2.22

516 Risk Analysis IX Table 2: Device s component Operating condition Patient leakage current when PE is open Patient leakage current in normal condition and supply and supply Patient leakage current when PE is open and supply Patient leakage current in normal condition Patient leakage current when PE is open Patient leakage current in normal condition and supply and supply Patient leakage current when PE is open and supply Patient leakage current in normal condition Patient leakage current when PE is open Patient leakage current in normal condition and supply and supply Patient leakage current when PE is open and supply Paddle V Patient leakage current in normal condition Paddle V Paddle V Patient leakage current when PE is open Paddle V Patient leakage current in normal condition and supply Paddle V and supply Continued. Measured value [μa] Simulated value [μa] 2 2.23 2 2.22 2 2.23 2 2.22 2 1.76 2 2.96 30 30.1 2 1.59 2 2.96 31 30.6 2 1.76 2 2.99 30 30.1 2 1.59 2 2.99

Risk Analysis IX 517 Acknowledgement The authors are grateful to Giacomo Fazi for his valid support during the model development and literature search. References [1] Amicucci, G. L., Di Lollo, L., Fiamingo, F., Mazzocchi, V., Platania, G., Ranieri, D., Razzano, R., Camin, G., Sebastiani, G., Gentile, P., Electrical safety during transplantation. Transplantation Proceedings, Elsevier, 42, pp. 2175-2180, 2010. [2] ISO/DIS 13824 General principles on risk assessment of systems involving structures 2008. [3] Corbellini, G., Impianti elettrici sicurezza elettrica nei locali adibiti ad uso medico e chirurgico, vol. 4 part. 1, La Goliardica Pavese, 1999. [4] Spalding, L., Carpes, W. Jr., Batistela, N., A method to detect the microshock risk during a surgical procedure. IEEE Transactions on Instrumentation and measurement, 58(7), pp. 2335-2342, 2009. [5] CEI EN 60601-1 Medical electrical equipment General requirements for safety 2nd ed., 1998. [6] CEI EN 62353 Medical electrical equipment Recurrent test and test after repair of medical electrical equipment, 2008. [7] CEI EN 60601-1 Medical electrical equipment - General requirements for basic safety and essential performance 3rd ed. 2007.