Operation Manual. Hand tool for AMP DUOPLUG Customer Manual PN: en (Translation of the original German version)

Similar documents
Operation Manual. Nano-MQS Hand Tool 0,13-0,35 mm². en (Translation of the original German version) 1/17

Operation Manual. IDC Hand tool RAST 2.5 and 5

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

Model ASSEMBLY and OPERATING INSTRUCTIONS

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

COMPACT METAL bender 99826

Operating Instructions Temperature Measuring System MF420-5T-100

Pressure maintenance valve SDV-P / SDV-P-E

Product Name: Angel Anchor

Portable Massage Table User Manual

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

6 digital caliper with case

PRAHER PLC-MP AQUASTAR MANAUL 2009

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M)

30T A/Manual Hydraulic Shop Press

Siphon vessel / Priming aid

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS Grips

REMS Swing INSTRUCTION MANUAL SINGLE-HAND TUBE BENDER SWING ANCRA

OPERATIONS MANUAL IMPORTANT SAFETY INFORMATION

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

RISK ASSESSMENT. Bobcat Excavator. Models , (Series D & G) For. Version 1.2

Norrsken Family Booklet

Portable Compressed CO 2 Regulator

STRIBOG GRAND POWER. The INSTRUCTIONS FOR USE, MAINTENANCE AND SAFETY. 1

OWNER S MANUAL. Read the instructions and warnings in this manual carefully before using this firearm; do not discard this manual.

IZH 60/61 air rifle owner s manual

DT400/436 Tee Connector Installation Instructions

e.do Gripper Safety requirements, technical features and assembly and integration instructions

Triple Tine Mechanical Grapple

AD-3050 Seal Test Equipment

SERVICE LETTER WARRANTY CONDITIONS FOR ROTAX

Pre-filter for Brushless Blower Instruction Manual

20 Ton SD Shop Press Operating Instructions

C - SERIES. Height Adjustable Portable Goal Supports. Installation & Owner s Instructions C1000 C2000. Made in the USA

USER MANUAL. JET TST and JET TST S.

Safety and operating instructions

Part #: 15158; 15159; 15188; 61027; 61029; 61140; 61141

Operating and maintenance manual Filter and reducing station Series / 1.0

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

COOPER POWER SERIES. 600 A 15, 25, and 35 kv class PUSH-OP bushing adapter cap installation instructions. Deadbreak Apparatus Connectors MN650050EN

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 6K Puller (M6K-M)

Owner s Manual & Safety Instructions

COOPER POWER SERIES. 600 A 15, 25 and 35 kv class bushing adapter installation instructions. Deadbreak Apparatus Connectors MN650058EN

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

1 DRIVE INDUSTRIAL IMPACT WRENCH

trigger magazine release

Product Name: Concrete Anchor Strap

SSS SWEEPERS MODELS MS-31 & MS-39

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

453 Series Steam Heated Vaporizing Regulator

OPERATOR S MANUAL SPREADER. CSS, VNQ [For Combine Harvester AW82V] Original instructions

Tactical Sniper air rifle & carbine

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

1ml] ARROWQUIP COM-CATCH 61 SERIES MANUAL SQUEEZE CHUTE PRODUCT MANUAL arrowquip.com

IZH 46M air pistol owner s manual

IZH 53M air pistol owner s manual

Product Name: 2-Way Standing Seam Roof Clamp

Product Name: Bull Ring Anchor

ALERT SERVICE LETTER

Name of product: Gripper of FTV panels for horizontal façades Types: PHF (60, 80, 100, 120, 133, 150, 172,200, 240) INSTRUCTIONS FOR USE

AIR INLINE METAL SHEAR

FLANGED TWO-PIECE BALL VALVES

Type BBS-03, BBS-05, BBS-06, BBS-25

Owner's Manual Product Line

MP532 AIR RIFLE INSTRUCTION MANUAL

Windy City II. User instruction manual WARNING: Fill pressure: 200 bar (approximately 2,900 psi)

Beeman Precision Airguns R-Series Air Rifle Owner s Manual

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

Preventive Maintenance

Instructions for Use Wire Rope Hoist SAT 08 / SAT 16 / SAT 32

Model Visit our website at:

Model No.: SFC-ED Torque Tool Serial No.: SFC Ref No.:

Mounting instructions

Product Name: Universal Guardrail Post

User s Manual. USB Golf Simulator. Contents

CP10K. 10,000 lb. Cable Puller Instruction Sheet. SAFETY ISSUES

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

Operating Instructions in accordance with the Machines Directive 2006/42/EC

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

3 Post Pressure Fit System Owner s Manual

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

INSTRUCTIONS FOR USE

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Copyright Trek Bicycle Corporation 2005 All rights reserved

Overspeed governors (113 OG Моment 250 MR, 114 OG Moment 250 A3, 115 OG Moment 250 MRL, 119 OG Moment 250 MRL/1)

Q-POWER 106 SERIES HYDRAULIC SQUEEZE CHUTE PRODUCT MANUAL arrowquip.com

M5400 Operators Manual

Defender Series Owner s Manual

Pressure Fit System - Two Post Version Owner s Manual

Instructions for assembly and use ZAP telescopic platform ladder Z600

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

TOCA MAINTENANCE & TROUBLESHOOTING MANUAL

PBT1100 POWER BANDING TOOL

Quadratec Delrin Door Hinge Pin Bushings for Jeep Wrangler YJ & TJ 94-06

Pressure relief valve

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

Operating Manual VSA100A. tina29e1 ( )

Transcription:

Operation Manual Hand tool for AMP DUOPLUG 2.5 549033-1 Customer Manual Nr.: 411-18031-1 _Rev. C Customer Manual PN: Language: en (Translation of the original German version)

The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging This document, as well as the data, specifications and other information set forth in it, are the exclusive property of TE Connectivity Ltd. It may not be reproduced or given to third parties without its consent. The cover page shows a sample configuration. The delivered product may thus differ from the figure. The original operation manual is written in German. 1/ 17 Operation Manual

1 General information... 3 1.1 Copyrights, industrial property rights...3 2 Using the operation manual... 4 2.1 Abbreviations used...4 3 General safety instructions... 5 3.1 Intended use...5 3.2 Improper use...5 3.3 Reasonably foreseeable misuse...5 3.4 Qualification of personnel...6 3.5 Safety instructions in this document...6 3.6 Adhere to the following instructions...7 3.6.1 General instructions...7 3.6.2 During operation...7 3.6.3 During disposal...7 3.7 Obligations of the operator...7 4 Scope of delivery... 8 5 Product description... 9 5.1 Identification of product...9 5.2 Handled connectors...9 6 Making a connection... 10 6.1 Insertion of wires...10 6.2 Fitting the lid...13 7 Maintenance and Repair... 15 7.1 Daily Maintenance...15 7.2 Periodically Maintenance...15 7.3 Wear and tear parts...15 8 Disposal... 16 9 Appendix... 17 9.1 Contact information...17 2/ 17 Operation Manual

1 General information 1.1 Copyrights, industrial property rights This document, as well as the data, specifications and other information set forth in it, are the exclusive property of TE Connectivity Ltd. It may not be reproduced or given to third parties without its consent. This manual is exclusively meant for the carrier of the Hand tool for AMP DUOPLUG 2.5 (in further course called Hand tool ) and its personnel for internal use only. The additional device-specific manual includes descriptions, engineering drawings, instructions and references, that you may not copy, reproduce or distribute without written consent neither completely nor in parts. If the competition try for discover and inspect this manual, we do expect the same fairness, that you may expect from your customers in that case. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Subject to change without notice. Errors and omissions excepted. 3/ 17 Operation Manual

2 Using the operation manual These instructions contain important information on the safe and appropriate operation and simple troubleshooting of the hand tool. Read these instructions completely, especially section 3 General safety instructions, before working with the Hand tool. TE Connectivity Ltd. decline to accept any liability for damages that are incurred due to the fact that the instructions in the operation manual have been disregarded. The user is responsible for supplementing the operation manual with any instructions resulting from current national regulations for accident prevention and protection of the environment. Also observe the generally applicable, legal or otherwise binding regulations of the European or national legislation and the rules for the prevention of accidents and for environmental protection applicable in your country. 2.1 Abbreviations used Abbreviation PN RoHS Meaning Part-No. Restriction of (the use of certain) hazardous substances 4/ 17 Operation Manual

3 General safety instructions The DUOPLUG Hand tool has been manufactured according to the accepted rules of current technology. There is, however, still a risk of personal injury or damage to equipment if the following general safety instructions and the warnings before the steps contained in these instructions are not complied with. Read these instructions completely and thoroughly before working with the hand tool. Keep these instructions in a location where they are accessible to all users at all times. Always include the operating instructions when you pass the hand tool to third parties. RoHS Information Information on the presence and location of any substances subject to RoHS (Restriction on Hazardous Substances) can be found at the following website: http://www.tycoelectronics.com/customersupport/rohssupportcenter/ Click on Find Compliance Status and enter equipment part number. 3.1 Intended use The Hand tool for AMP DUOPLUG 2.5 has been designed to apply connectors according to the AMP specification 114-18049 (section 5.2 Handled connectors ) with wires following the grid connection plug technology using Insulation Displacement Technique. It is only permitted to use the 114-18049 exclusively for repair proposes or preparation of samples. Do not use it for serial production. The hand tool is not a product in terms of the EU-Machinery Directive 2006/42/EG. Intended use includes having read and understood these instructions, especially section 3 General safety instructions. Application Notes: Cumulative Trauma Disorders can result from a prolonged use of manually powered hand tools. TE Connectivity Ltd. hand tools are intended for occasional use and low volume applications. For extended use or production operations TE Connectivity Ltd. offers a wide selection of powered application equipment. 3.2 Improper use Any use of the Hand tool other than described in section 3.1 Intended use is considered as improper. 3.3 Reasonably foreseeable misuse Any attempt to use this hand tool with other than the specified connectors, described in section 5.2 Handled connectors is considered as a reasonable foreseeable misuse. Moreover, the hand tool may used exclusively within the limits of its intended use (section 3.1 Intended use ). 5/ 17 Operation Manual

3.4 Qualification of personnel In order to ensure operating safety, these activities may therefore only be carried out by qualified technical personnel or an instructed person under the direction and supervision of qualified personnel. Qualified personnel are those who can recognize possible hazards and institute the appropriate safety measures due to their professional training, knowledge, and experience, as well as their understanding of the relevant conditions pertaining to the work to be done. Qualified personnel must observe the rules relevant to the subject area. 3.5 Safety instructions in this document Type of risk! Consequences Precautions Safety sign (warning triangle): Draws attention to the hazard Signal word: Identifies the degree of hazard Type of danger: Identifies the type or source of the hazard Consequences: Describes the consequences of non-compliance Precautions: States how the hazard can be prevented The signal words have the following meaning: Signal word Application Indicates an imminently hazardous situation which, if not avoided, will certainly result in serious injury or even death. Indicates a potentially hazardous situation, which, if not avoided, could result in serious injury or even death. Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury or damage to equipment. If this information is disregarded, it may result in machine malfunction or breakdown. 6/ 17 Operation Manual

3.6 Adhere to the following instructions 3.6.1 General instructions Observe the regulations for accident prevention and environmental protection for the country where the product is used and at the workplace. Exclusively use the hand tool in good technical order and condition. Check the hand tool for visible defects. You must generally not modify or retrofit the product. Only use the product appropriate to the intended use described in this manual. Person who assemble, operate, disassemble or maintain the machine must not consume any alcohol, drugs or pharmaceuticals that may affect their ability to respond. Before putting the hand tool into operation, it is always important to check whether all devices are at hand and functioning correctly. The warranty only applies to the delivered configuration. The warranty will not apply if the product is incorrectly assembled, not used as intended and/or handled improperly. If the hand tool is apparently damaged or do not work proper, you must send it in for repairs (section 9.1 Contact information ). 3.6.2 During operation Only persons who have been authorized by the operator may be granted access to the direct operating range. 3.6.3 During disposal For environmentally friendly disposal please observe the notes in section 8 Disposal. 3.7 Obligations of the operator The operator of the TE Connectivity Ltd. products is bound to provide for personnel training on a regular basis regarding the following subjects: Observation and use of the operating instructions and the legal regulations Intended use and operation of the hand tool. 7/ 17 Operation Manual

4 Scope of delivery The scope of delivery includes following parts: 1 Hand tool for AMP DUOPLUG 2.5 1 operating manual 8/ 17 Operation Manual

5 Product description The hand tool has been designed to apply connectors according to the TE specification 114-18049 with wires using Insulation Displacement Technique. It is only permitted to use the Hand tool for AMP DUOPLUG 2.5 only for repair proposes or preparation of samples. Do not use it for serial production. 5.1 Identification of product For clearly identification of product the hand tool is marked with the Part number (arrow). Fig. 1: Identification of product 5.2 Handled connectors Following connectors according to the TE specification 114-18049 are used: Connector PN X-829868-X PN X-829869-X PN X-966194-X PN X-966195-X Wire specification DGB I solid wire ø0.4 mm and ø0.5 mm bonded wire 7 x ø0.15 = 0.12 mm² bonded wire 7 x ø0.16 = 0.14 mm² stranded wire 7 x ø0.20 = 0.22 mm² stranded wire 12 x ø0.21 mm = 0.35 mm² DGB II stranded wire 7 x ø0.25 mm = 0.35 mm² 9/ 17 Operation Manual

6 Making a connection Fig. 2: Construction 1 Stop 3 Spring stuffers (both-sided) 2 Stuffer 4 Guide groove 6.1 Insertion of wires Push the connector housing into the guide groove (4) until the stuffer (2) is positioned above the first chamber (Fig. 3 item 5) which is to be terminated. The housing will arrest in each position. Fig. 3: Insertion of connector housing 10/ 17 Operation Manual

Push the individual wire completely against the stop (Fig. 4). With DAISY CHAIN terminations the stop will move back on contact. Fig. 4: Insertion of wire Close the gripper completely. Fig. 5: Closing the gripper 11/ 17 Operation Manual

Then open the gripper. Fig. 6: Opening the gripper Push the connector housing further until the stuffer is positioned above the next chamber to be terminated. Repeat the described procedure until the connector is terminated completely. Do not tension the wires due to damaging the contacting! 12/ 17 Operation Manual

6.2 Fitting the lid Push the connector housing into the last possible arrest position (towards the pivot point of the gripper). Place the lid on the housing (Fig. 7). Make sure that the lid is correctly aligned. Fig. 7: Fitting the lid Close the gripper completely. Fig. 8: Closing the gripper The lid must visibly engage into the housing! 13/ 17 Operation Manual

The open the gripper. Fig. 9: Opening the gripper Pull the connector forwards out of the guide. Do not tension the wires due to damaging the contacting! 14/ 17 Operation Manual

7 Maintenance and Repair 7.1 Daily Maintenance For the daily maintenance following steps has to be taken by the responsible operator: Clean up the tool from dust, humidity and other residues by means of a clean, soft scrubber or a lint-free cloth. Never use rigorous or abrasive mediums to avoid damaging the tool. All pins, pivot points and bearing surfaces must be provided with a high-quality SAE20 motor oil. Avoid excessive lubrication. If the hand tool is no longer required, pinching the gripper and store the hand tool dry and clean. 7.2 Periodically Maintenance Depending on the degree of utilization an inspection of the Hand tool for AMP DUOPLUG 2.5 should be done by an appropriate qualified personnel. Pinching the gripper until the mechanism of the lever brace released resp. opened and let the gripper opened. Do not loose the gripper too fast and completely to avoid damaging the tool head s springs. Check the hand tool on abrasions and damaging, in particularly in the field of the crimper and all pivot points. 7.3 Wear and tear parts All wear and tear parts can be replaced easily Stuffer PN 0-0578699-1 Stop PN 0-0578702-1 Spring (Stop) PN 0-0578705-1 15/ 17 Operation Manual

8 Disposal Careless disposal of the applicator lead to pollution of the environment. In case of disposal, please send the hand tool back to the address specified in section 9.1 Contact information. 16/ 17 Operation Manual

9 Appendix 9.1 Contact information TE Connectivity c/o Schenck Technologie- und Industriepark GmbH Landwehrstr. 55 / Gebäude 83 64293 Darmstadt Field Service EMEA@te.com GATD Kundendienst-Hotline: +49-6151-607-1518 17/ 17 Operation Manual