two component solvent free amine cured phenolic epoxy coating (1 g/cm³ = 8.25 lb/us gal; 1 m²/l = 40.7 ft²/us gal) (data for mixed product)

SIGMAGUARD CSF 575. PRODUCT DATA SHEET September 14, 2015 (Revision of September 14, 2015) DESCRIPTION

Hardener: at least 24 months when stored cool and dry

To be used as a coating for potable water tanks and pipes. Independently tested and certified for potable water storage. Other

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 33 C calculated VOC-USA / VOC Hong Kong EPA Method 24

To be used as a coating for potable water tanks and pipes. Independently tested and certified for potable water storage. Other

Property Test/Standard Description

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 36 C calculated VOC-US/Hong Kong US EPA method 24 (tested)

Property Test/Standard Description

Specially designed for maintenance and repair of dedicated water ballast tanks on vessels and offshore structures. Other

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 35 C calculated IED (2010/75/EU) (theoretical)

Approved. Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong

Two coats are normally recommended. Some service may require mils DFT

Technical Data Megacote

Property Test/Standard Description

Property Test/Standard Description

Can be used on helidecks, walkways, ramps, weigh bridge decks, decks in general where abrasion resistance and non-slip properties are required.

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 55 C VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description

Property Test/Standard Description

Property Test/Standard Description

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 25 C

Property Test/Standard Description

Approved. Marine: Exterior areas, specially designed for outside hull, may be used on superstructure, decks and other external areas.

Property Test/Standard Description. 63± 2 % Gloss level (GU 60 ) ISO gloss (70-85) Flash point ISO 3679 Method 1 30 C

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 36 C

General: Primarily designed for maintenance and repair. In immersed environments Jotamastic 80 Aluminium is suitable.

Polidura Glossy PU Topcoat Component A: 6103 Component B: 6199

10P20-13 High Solids Primer

Before application, test the atmospheric conditions in the vicinity of the substrate for the dew formation according to ISO

Carboguard 893 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

APPLICATION GUIDE ECOSPEED FOR ALUMINIUM SURFACES

Before application, test the atmospheric conditions in the vicinity of the substrate for the dew formation according to ISO

aluminium, aluminium red toned, black, white and according to Multicolor Industry tinting system (MCI)

Designed for both global and coastal trade. Recommended for exposure to both sea and fresh water during newbuilding outfitting. Antifouling.

AMERCOAT 370. PRODUCT DATA SHEET June 16, 2016 (Revision of October 9, 2015) DESCRIPTION. Two-component, fast dry multi-purpose epoxy coating

The Application Guide offers product details and recommended practices for the use of the product.

DFT in excess of 8.0 mils per coat is not recommended.

SAFETY IN CONFINED SPACES AND HEALTH SAFETY EXPLOSION HAZARD - TOXIC HAZARD

*Valid if manufactured at a certified location. Light Grey (0700), White (0800), and Light Blue (0100). Colors are unmatched

AkzoNobel Aerospace Coatings. Primerr. Product Group. Epoxy primer. Characteristics Product Information. resistance. Components * TR-114. permits.

PAC33NV Polyurethane Primer. Mix Ratio (by volume) 4359/3600 (Base) 5 parts 0701/9000 (Activator) 1 part 0477/9000 (Thinner) 3 parts

Date of issue: 20 April 2018 Page: 1/6

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 35 C calculated IED (2010/75/EU) (theoretical)

As Supplied : 1.67 lbs/gal (200 g/l) Plasite Thinner #71 : 10% by volume 2.18 lbs/gal (261 g/l)

CV117 Hydraulic Fluid Resistant PU Lacquer. ACT34 (Activator) NOTE: No thinner is required for brush application

PAC33 Polyurethane Primer. Mix Ratio (by volume) 4355/3600 (Base) 5 parts 0701/9000 (Activator) 1 part 0433/9000 (Thinner) 4-5 parts

The Application Guide offers product details and recommended practices for the use of the product.

PACKAGING: Component A W-THANE HBA CD (2,7 L) Component B W-THANE 5057 CD (0,9 L)

Self-priming. May be applied over most generic types of coatings.

TECTYL 1422S APPLICATION PROCEDURES AND TROUBLESHOOTING GUIDE

Specification. M/V Viggen Viggen Drydocking of 16. Oy Hempel (Finland) Ab Bertel Jungin aukio 5 FI Espoo Finland hempel.

*RTS not recommended for immersion service. Do not exceed 10 mils in a single coat (without additives)

PR219 Epoxy Primer Undercoat

Part of Group Assortment. Local availability subject to confirmation.

Technical Data Sheet PART A & PART B

Autoclear Mix & Matt

TECHNICAL DATA SHEET PP404. PP404 Epoxide Primer. Product Description. Components. Specifications. Surface Preparation and Pretreatment

Aerodur 2111 Chrome Free Primer

Epoxy Non-chromate Corrosion Inhibiting Primer. Alumigrip 4101P001 Alumigrip 4901 (CS4901) AkzoNobel Aerospace Coatings. Bombardier Hawker Beechcraft

PR143 (ACT 149) Epoxy Primer

5014 PU Surfacer. Highly flexible Water resistant Good fluid resistance including phosphate ester hydraulic fluids Transparent to ultrasound & radar

5541/9000 UV Resistant Varnish Semi Gloss. 0701/9000 (Activator) 5541/9000 meets the requirements of : AIMS

TECHNICAL DATA SHEET CA7040. CA7040 HS CF Polyurethane Primer. Product Description. Components. Specifications. Surface Preparation and Pretreatment

EC96 HS Epoxy Topcoat. 1 part. ACT197 (Activator) near matt. 1 part

NAVSEA REVIEWED ASTM F-718. If this product is to be applied as part of a coating system, all components of the system must be as listed on the QPL.

HR39/801 Heat Resistant Topcoat Matt Black. HR39/801 is a heat resistant topcoat suitable for interior and exterior use.

PRODUCT DATA SHEET. Advanced Industrial Coatings 2.1 VOC Epoxy Primer AIP302 Gray, AIP303 White PERSONAL PROTECTION SURFACE PREPARATION

Interzinc 22 Application Guidelines

EC75/C9071 Epoxy Clear Coat. EC75/C9071 (Base) ACT65 (Activator) 0.33 part (spray application)

Heresite VR-514 T E C H N I C A L D A T A S H E E T

Desothane CA8311 HS Polyurethane Topcoat Matt

CA3120 Anti-fretting Epoxy Varnish. Excellent anti-fretting properties High lubrication rate Abrasion resistant Allows high friction coefficient

TECHNICAL DATA SHEET EC75. EC75 Epoxy Topcoat. Product Description. Components. Specifications

High Solids, low VOC Excellent durability Excellent flexibility Wide range of mica particle size and surface effects available

Part of Group Assortment. Local availability subject to confirmation.

The Application Guide offers product details and recommended practices for the use of the product.

The Application Guide offers product details and recommended practices for the use of the product.

Imron 2.1 PR Polyurethane Primer

Imron Industrial Strength Ultra Low VOC Polyurethane Clear Reduced Gloss Modifications

DP40 is a versatile 2K Epoxy Surfacer. It is light grey in colour, chromate-free and has good corrosion resistance over bare metal.

PD100 White, PD200 Black Low VOC Acrylic Polyurethane Topcoat

Desofill CA8620 HS PU Sanding Surfacer. CA8000B (Activator) CA8000C or CA8000C2 (Thinner)

Enviroline 405HTR Application Guidelines

4125 Direct Adhesion Epoxy Coating. Two pack, direct adhesion epoxy topcoat Applicable with all types of fasteners Excellent adhesion properties

COATINGS SPRAY GUIDE Acrylics (210, 211, 211HT, and 212)

Super Koropon 515X333 fluid resistant primer is a chemical and solvent resistant epoxy coating used in areas exposed to hydraulic fluid.

TECHNICAL DATA SHEET 44Y Y032 Water Reducible Epoxy Primer. Product Description. Components. Specifications

Desoprime HS CA7422 Chrome-Free Epoxy Primer

Desoprime HS CA7233 Military Epoxy Primer

Interline 399 Application Guidelines

Desoprime HS 533K004 Military Epoxy Polyamide Primer

Eco-Prime EWDE072 Military Water-Borne Epoxy Primer

COATINGS SPRAY GUIDE Urethane 520

44GN008A Water Reducible Type II Epoxy Primer

Intertherm 3070 Application Guidelines

PRO-TEX TRUCKBED LINER TECHNICAL DATA SHEET

Mix ratio (by volume) for gloss colors: CA8800/XXXX (base component) CA8800Z (activator component) CA8800CT (thinner component)

AQUABASE PLUS P Extended Performance Clearcoat

Interline 9001 Application Guidelines

Transcription:

6 pages Revision of February 2006 DESCRIPTION two component solvent free amine cured phenolic epoxy coating PRINCIPAL CHARACTERISTICS one coat tank coating system clear version is the basis for the glassmat reinforced solvent free tank bottom system (see system sheet 4145) excellent resistance to crude oil up to 194 F (90 C) suitable for storage of unleaded gasolines good chemical resistance against a wide range of chemicals and solvents good visibility due to light color glossy and smooth appearance easy to clean can be applied by heavy duty single feed airless spray equipment (60:1) reduced explosion risk and fire hazard approved to Air BP F2D2 section 2.1 for the storage of jet fuels COLORS AND GLOSS green, cream, clear - gloss BASIC DATA AT 68 F (8.25 lb/us gal = 1 g/cm³; 40.7 ft²/us gal = 1 m²/l) (data for mixed product) Mass density 10.85 lbs/gal (1.3 g/cm³) Solids content 100% VOC (supplied - EPA 24) max. 106 g/kg (Directive 1999/13/EC, SED) max. 1.2 lb/gal (approx. 142 g/l) see information sheet 1411 Recommended dry film 12-24 mils (300-600 µm) depending on system thickness Theoretical spreading rate 134 ft²/gal (3.3 m²/l) for 12 mils (300 µm) * Touch dry after 6 hours Overcoating interval min. 24 hours * max. 2 months * Full cure after 5 days * Shelf life (cool and dry place) (data for components) at least 12 months * see additional data page 1/6

RECOMMENDED SUBSTRATE CONDITIONS AND TEMPERATURES steel; blast cleaned to a minimum of SSPC SP10/NACE 2 (ISO-Sa2½), blasting profile (R z ) 2-4 mils (50-100 µm) substrate temperature must be above 41 F (5 C) and at least 5 F (3 C) above dew point during application and curing steel with suitable primer (Sigma Phenguard 930) which must be dry, clean and free from any contamination INSTRUCTIONS FOR USE mixing ratio by volume: base to hardener 80 : 20 Induction time the temperature of the mixed base and hardener should preferably be at least 68 F (20 C) at lower temperature the viscosity will be too high for spray application no thinner should be added for recommended application instructions: see working procedure none Pot life 1 hour at 68 F (20 C) * * see additional data AIRLESS SPRAY use heavy duty single feed airless spray equipment preferably 60:1 pump ratio and suitable high pressure hoses in-line heating or insulated hoses may be necessary to avoid cooling down of paint in hoses at low air temperature length of hoses should be as short as possible Recommended thinner Nozzle orifice Nozzle pressure BRUSH/ROLLER Recommended thinner no thinner should be added approx. 0.021" inch (= 0.53 mm) at 68 F (20 C) (paint temperature) min. 4000 p.s.i. (= approx. 28 Mpa or 280 bar) at 86 F (30 C) (paint temperature) min. 3000 p.s.i. (= approx. 22 MPa or 220 bar) for stripe coating and spot repair only no thinner should be added CLEANING SOLVENT Sigma thinner 90-83 (preferred) or Sigma thinner 90-53 all equipment used for application must be cleaned immediately after use paint inside the spraying equipment must be removed before the pot life time has been expired page 2/6

SAFETY PRECAUTIONS ADDITIONAL DATA for paint and recommended thinners see safety sheets 1430, 1431 and relevant material safety data sheets although this is a solvent free paint, care should be taken to avoid inhalation of spray mist as well as contact between the wet paint and exposed skin or eyes no solvent present; however, spray mist is not harmless, a fresh air mask should be used during spraying ventilation should be provided in confined spaces to maintain good visibility Film thickness and spreading rate theoretical 134 (3.3) 69 (1.7) spreading rate ft²/gal (m²/l) dft in mil (µm) 12 (300) 24 (600) max. dft when brushing: 6 mils (150 µm) measuring wet film thickness a deviation is often obtained between the measured apparent wft and the real applied wft this is due to the thixotropy and the surface tension of the paint which retards the release of air trapped in the paint film for some time recommendation is to apply a wft which is equal to the specified dft plus 2 mils (50 µm) measuring dry film thickness because of low initial hardness the dft cannot be measured within some days due to the penetration of the measuring device into the soft paint film the dft should be measured using a calibration foil of known thickness placed in between the coating and the measuring device page 3/6

Overcoating with Sigma Novaguard 840 (spot repair and stripe coating) substrate temperature minimum interval maximum interval surface should be dry and free from any contamination Curing table 41 F 50 F 68 F 86 F (5 C) (10 C) (20 C) (30 C) 80 hours 36 hours 24 hours 16 hours 3 months 3 months 2 months 1 month substrate temperature dry to handle full cure 41 F (5 C) 60 hours 15 days 50 F (10 C) 30 hours 7 days 68 F (20 C) 16 hours 5 days 86 F (30 C) 10 hours 3 days adequate ventilation must be maintained during application and curing (please refer to sheet 1433 and 1434) for storage and transport of drinking water the recommended working procedure should be followed WASHING PROCEDURE all personnel should wear watertight suits, boots and gloves properly cleaned with a sodium hypochlorite solution (1% active chlorine per liter) all tank sides, bottom and deckheads etc. should be brush cleaned or high-pressure spray cleaned with 1% active chlorine solution as above note: this can also be done by butterworth washing all parts should be high pressure cleaned with tap water and tanks drained concentrated active chlorine solution should be sprinkled on bottom; approx. 1quart/100 ft² (1 ltr/10 m²) tanks should be filled with tap water to a depth of approx. 8 inches (20 cm) and the water should remain in the tank for at least 2 hours (max. 24 hours) tanks should be thoroughly flushed out with tap water depending upon local regulations it may be necessary to take water samples, after filling tank completely, to check on bacteria after this procedure the tanks will be fit to carry drinking water page 4/6

Pot life (at application viscosity) 68 F (20 C) 86 F (30 C) 60 min. 45 min. due to exothermic reaction, temperature during and after mixing may increase Worldwide availability Whilst it is always the aim of SigmaKalon Marine & Protective Coatings to supply the same product on a worldwide basis, slight modification of the product is sometimes necessary to comply with local or national rules/ circumstances. Under these circumstances an alternative product data sheet is used. REFERENCES Explanation to product data sheets see information sheet 1411 Safety indications see information sheet 1430 Safety in confined spaces and health safety Explosion hazard - toxic hazard see information sheet 1431 Safe working in confined spaces see information sheet 1433 Directives for ventilation practice see information sheet 1434 Cleaning of steel and removal of rust see information sheet 1490 Specification for mineral abrasives see information sheet 1491 page 5/6

LIMITATION OF LIABILITY The information in this data sheet is based upon laboratory tests we believe to be accurate and is intended for guidance only. All recommendations or suggestions relating to the use of the Sigma Coatings products made by SigmaKalon Marine & Protective Coatings, whether in technical documentation, or in response to a specific enquiry, or otherwise, are based on data which to the best of our knowledge are reliable. The products and information are designed for users having the requisite knowledge and industrial skills and it is the end-user's responsibility to determine the suitability of the product for its intended use. SigmaKalon Marine & Protective Coatings has no control over either the quality or condition of the substrate, or the many factors affecting the use and application of the product. SigmaKalon Marine & Protective Coatings therefore does not accept any liability arising from loss, injury or damage resulting from such use or the contents of this data sheet (unless there are written agreements stating otherwise). The data contained herein are liable to modification as a result of practical experience and continous product development. This data sheet replaces and annuls all previous issues and it is therefore the user's responsibility to ensure that this sheet is current prior to using the product. In the event of any disparity or dispute in the wording of this document, the original English text shall prevail. PDS 7468 237775 cream 3012002200 180207 green 4000001400 page 6/6