Recent Advances to Ensure Simple, Leak Free GC Column Connections. Ken Lynam R&D/Application Chemist Agilent Consumables and Supplies Division

Similar documents
Products Designed to Solve Nagging GC Problems

Best Practice for Identifying Leaks in GC and GC/MS Systems

Agilent G3180B Two-Way Splitter Kit

6890 GC Site Preparation

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

no peaks missing peaks too small peaks increasing retention decreasing retention

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

Considerations and Best Practices for Maintaining Your Agilent GC s Split/Splitless Injection Port

The Open-Split Capillary Interface. Part No

Capillary Conversion System CCS-4/NC & CCS-05/NC. Installation and Operating Instructions. Operating Instructions

Connecting a SSL/PTV Backflush System

GC Accessories. Agilent Consumables. Agilent Instrument Specific Replacement Parts. SGE Replacement Parts by Instrument Vendor.

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Advances in Capillary Column Backflushing

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 5975C MSD Series G3170A, G3171A, G3172A, G3174A

Super-Clean Gas Filters from Restek

Thermo Scientific Chromatography Well Plates

Thermo Scientific Chromatography Well Plates

Please refer to the Hydrogen Safety Guide which is shipped with the Instrument. 5977B Series GC/MS Systems Site Preparation Checklist

Retention Time Locking: Concepts and Applications. Application

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

CP-3800 GC Getting Started Manual

Customer Responsibilities. Important Customer Information GCMS QQQ Site Preparation Checklist

ms NoVent II Instruction Booklet

COMPRESSION TUBE FITTINGS

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

7820A GC Site Preparation Checklist

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

3 Flow and Pressure Control

Ascentis Express HPLC Columns with Fused-Core Technology

Zebron Gas Management

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Simple and Worry Free Gas Filters

APPLICATION NOTE. GC Integrated Permeation Device

Converting Helium Carrier Gas GC Methods Nitrogen and Hydrogen

Impact of Air Leaks on the Productivity of GC and GC/MS Systems

A Column-Flow Independent Configuration for QuickSwap. Application. Authors. Abstract. Introduction

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing

COMPRESSION TUBE FITTINGS

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

Agilent 7697A Headspace Sampler

Agilent G Rebuilt Electron Capture Detector

For additional information about our solutions, please visit our web site at US/Pages/HomePage.

Carrier Gases in Capillary GC

Markes Thermal Desorption Systems Site Preparation Page 1 of 8

500 deg C Max in air unlimited in an inert gas Soft and Malleable. & with No phase

LC, RSLC, Bio RS and Dual Gradient Systems

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

Agilent Inlet EPC Leak Test

Mass Spec will not Autotune

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Multiple Gas#5 GC configuration Jan 2016

Instant Connect Helium Saver Injector Module

Agilent 7890 / 220 Ion Trap GCMS Site Preparation Checklist

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule

Agilent 7697A Headspace Sampler

SRI Model H2-40 Hydrogen Generator Operation and Maintenance Nov 2006

PURA. Pure Gas Dewpoint Transmitter. Users Guide

Agilent 7890 Series Gas Chromatograph

// ADapters GUIDelines

Agilent 1290 Infinity Pump Head Maintenance

COMPRESSION TUBE FITTINGS 1/16 THROUGH 2 -INCH, 2 MM THROUGH 50 MM-METRIC

UWPR. LC-MS setup. Before you connect your trap and column. Connecting your trap and column

GCMSD-Headspace Analysis SOP

Crimpers and Decappers

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

be present throughout these services; otherwise, they will miss important operational, maintenance and safety information.

Wheel operated Residual Pressure Valves

SCF Enviro-Friendly. Back-up Ring. Endcap. #7141 (for both) O-Ring. Back-up ring and O-ring fit onto end cap.

Buck Scientific, Inc.

Agilent G3185B QuickSwap Accessory

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Tips and Tricks of Injector Maintenance. Abby Folk Agilent GC Technical Support August 2009

Carrier Gases in Capillary GC

MicroJet Cryo-Trap MODEL MJT-1030Ex OPERATION MANUAL

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

HICHROM. HPLC Accessories

HiQ laboratory gas generators.

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

Major Design Features

Experiment GC : Analysis of BTEX by GC-FID

Agilent 7697A Headspace Sampler

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Valves FLUIDICS VALVE OVERVIEW & FUNCTIONS ROTARY SHEAR VALVES STAND ALONE VALVE PRODUCTS MANUAL VALVES SPARE PARTS VALVE ACCESSORIES

Running HPLC Methods on an ACQUITY UPLC System

USER'S GUIDE. Nanoflow Probe. Red Stripe. 3-4mm. ptfe Sleeve. To Injector. ZU1XC Fused Silica TTF115. Fused Silica. ptfe Sleeve

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

World Area Differences Technical Information

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Fiber Optic SMA Z-Flow Cell Manual Version 2.1

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

Transcription:

Recent Advances to Ensure Simple, Leak Free GC Column Connections Ken Lynam R&D/Application Chemist Agilent Consumables and Supplies Division 1

GC column installation is a challenge A routine, basic procedure but not easy to do Very small parts Wrenches in cramped, dark space 2 chances to get it wrong: at the inlet and the detector What can go wrong? Height into the fitting Leaks Activity 2

How do you make better GC column connections? 1. Start with the right tools and supplies Column nuts Material : stainless but need brass for MS interface Choice of right ferrules 2. Proper assembly process Make a good clean column cut every time After ferrule is installed Fused silica tubing cutters : ceramic Magnifier to inspect the cut - cracked fused silica and flaps of polyimide are active sites that ruin chromatography 3. Ensure the proper and consistent length of column into the fitting 3

Supply Selection: Which Capillary Ferrules to use? polyimide polyimide/graphite graphite flexible metal Composition Re-use Max T Use Limitation Polyimide (Vespel) yes 280 Easy seal Shrink after heating causing leaks after thermal cycle; isothermal only Graphite yes 450 FID, NPD Inlets Contamination, permeable to air not for oxygen sensitive detectors Polyimide/graphite (85% / 15%) limited 350 MS, ECD, Inlets Still shrink after thermal cycles creating leaks; need to retighten regularly Flexible metal no 450 Capillary Flow Technology (backflush, splitters, ) May not seal well with damaged fittings or rough surfaces Short ferrules for inlet and detector configurations on Agilent GC s Long ferrules for MS transfer lines and MS interface nut 4

Supply selection: Graphite Ferrules Often selected because high temperature range (450C) the least expensive capillary ferrules Soft, easily conform to fitting shape and size Active sites in the flow path But do not over tighten! Over tightening of ferrules Causes ferrule material to extrude into the fitting Creates active sites if in the flow path Can flake or fall apart, blocking flow path and requiring extensive maintenance Extensive Inlet maintenance needed Remember Graphite is NOT recommended with MS, ECDs or for use with column stationary phases sensitive to air because it is permeable to air 5

Supply Selection: Graphite/polyimide blend ferrules Graphite / polyimide blend ferrules are very popular Recommend Long style for Mass Spec Short for Inlets, and other oxygen sensitive detectors, like ECD Soft enough to make seal against rough surfaces Fairly high temperature stability (350C) Don t extrude beyond the fitting when tightened (like graphite) Lower air permeability than pure graphite 6

Graphite / Polyimide blend capillary ferrules Unfortunately leak following normal temperature program runs Studies show the leaking continues with use of the ferrules - Not just after the first one or two runs Application Note 5991-3612EN Frequent re-tightening of the fitting is needed to maintain a leak-free seal and system performance and productivity 7

Supply Selection: capillary column nuts Column nuts are determined by the instrument fitting Basic mechanical fittings with little enhancements Brass for the MS Some finger tight designs for ease of use New design addresses ease of use and productivity issues of leaking and over tightening 8

Better Connections: Agilent Self Tightening Column Nuts Designed for use with short graphite/polyimide blend ferrules both at the inlet and the MS interface so only one type of ferrule needed for both ends of the column! For inlet or detector For mass spec transfer line Short ferrule exposes more thread of the fitting for better sealing 9

How do Self Tightening column nuts work? Ease of use install in dark, small space in GC oven without wrenches Wing design for finger tight installation with graphite/polyimide blend ferrules No tools dramatically reduces force preventing over tightening or damage Robust stainless steel construction Plus. Novel spring driven piston design that continuously presses against the ferrule to maintain a leak-free fitting even when the ferrule shrinks during temperature program! 10

Benefit of Self-Tightening Column nuts Take you from this.. to this! Without retightening, the baseline remains flat after 400 runs with no indication of leaks when using the Self Tightening column nuts 11

How do you make better GC column connections? ü 1. Start with the right tools and supplies Choice of right ferrules = short graphite/polyimide Column nuts = Self Tightening 2. Proper assembly process Make a good clean column cut every time After ferrule is installed Fused silica tubing cutters : ceramic Magnifier to inspect the cut - cracked fused silica and flaps of polyimide are active sites that ruin chromatography 3. Ensure the proper and consistent length of column into the fitting 12

Column installation assembly process 1. Thread through an inlet septum 2. Pass column through the column nut 3. Install ferrule onto the column tubing 4. THEN make a fresh cut 5. Inspect the cut; repeat cut if any jagged or rough edges 5 3 2 1 4 13

Ensure the proper length Column Installation Tools Follow the manufacturer s recommended procedure Optimized GC performance and reproducibility requires ensuring the proper length of column into the fittings, every time Column Installation pre-swaging tools for the Split/ Splitless inlet Available for Agilent GC models 7890 and 6890, for graphite or metal ferrules PreSwaging tool for the MS interface G1099-20030 G3440-80218 / G3440-80217 14

How do you make better GC column connections? ü 1. Start with the right tools and supplies Column nuts = Self Tightening Choice of right ferrules = short graphite/ polyimide ü 2. Proper assembly process Make a good clean column cut every time After ferrule is installed Inspect the cut ü 3. Ensure the proper and consistent length of column into the fitting 15

Better connections: Beyond the basics Effluent manipulation for productivity: Split effluent from a single column to 2 even 3 detectors on the same GC. Backflush - replaces a bakeout period for high-boiling analytes that collect in the column then interfere with subsequent analyses GC x GC or 2-dimensional GC Powerful tool used in environmental, food and flavor analysis, and hydrocarbon processing industries Separates complex mixtures using two independent columns with different stationary phase selectivity Columns are connected in series and separated by a modulator Limitations to Adoption of : All column connections must: be inert, not adsorbing or decomposing analytes have low thermal mass and low dead volume to maintain sharp peak shapes be leak free and stay so not outgas from materials used to make the seal withstanding the temperatures used in the GC analysis not be technique dependent must be easy to do 16

Advanced techniques increase the number of connections Simple addition of a retention gap or guard column doubles the column connections Powerful advanced GCxGC systems with many connections 17

Better Connections: Glass column connectors Ultra Inert Press Fits Join retention gap or guard column to analytical, or split effluent Dependable inertness performance at a lower cost Improved robustness, holding strength Batch certified inertness Improved packaging and installation instructions Easier to use - transparent deactivation gives visibility of the column connection 18

Better Connections: Capillary Flow Technology Devices UltiMetal Plus Ultimate Union/UltiMetal Plus Tee Stainless Steel Micro Fluidic plates technology Deactivation essential to block active sites Column connection easy to assemble Release hole for stuck ferrules Using Flexible Metal ferrules to overcome issues UltiMetal Plus surface chemistry prevents activity Flexible design reduces risk of over tightening or column breaks Leak free seal remains after repeated temperature cycles 19

Impact of ferrule surface on inertness Very small amount of ferrule surface exposed to active pesticides x10 4 Untreated FMF Post column Std 500ppb 2 1 Acephate Omethoate Demeton-S 0 4 x10 2 FMF + UltiMetal Plus Post column Std 500ppb Acephate Omethoate Demeton-S 1 0 4.5 5 5.5 6 6.5 7 7.5 Counts vs. Acquisition Time (min) 20

Better connections: UltiMetal Plus Tubing and Fittings UltiMetal Plus Deactivated metal tubing and valves 0.53 and 0.25 mm ID guards and transfer lines Metal fittings (unions, tee s and nuts) Steel tubing (1/16, 1/8, ¼ ) Ultimetal Plus fused silica guard columns Ensure the entire chromatographic solution is inert and corrosion resistant to provide superior performance with improved peak shapes even for active compounds 21

Making Better GC Connections Select supplies appropriate for your instrument and application Follow recommended assembly process Maximize productivity by using innovative tools and supplies Ø Column Installation Pre-swaging tools Ø Self Tightening column nuts Ø Ultra Inert Press Fit connectors Ø UltiMetal Plus Flexible metal ferrules Ø UltiMetal Plus tubing and fittings 22

Hot GC Surfaces in Contact with Samples the Need for Inertness Split/Splitless Inlet Inlet Liner Gold Seal Ferrules Capillary Flow Technology Devices, Ultimate Union GC Column 23

Agilent Inert Flow Path Solution Ultimetal Plus Inlet Weldment, Shell and Transfer Lines Ultimetal Plus TCD, FPD, NPD/FID Jets Ultra Inert Inlet Liner Ultimetal Plus Ferrules Ultimetal Capillary Flow Technology Devices, Ultimate Union Ultra Inert Gold Seal Ultra Inert GC Column 24

UltiMetal Plus Flexible Metal Ferrules improve Capillary Flow Technique column connections 1 Grooves reduce stiffness during installation, improve ID constriction for reliable seal without breaking columns Wider opening for easier column insertion 5 UltiMetal Plus surface deactivation eliminates activity 4 3 2 Tighter ferrule ID specification and tolerances (30%) for consistent leak free seal Angle eliminates wall frictional contact to allow the material to flow preventing damage to the fitting 25

Ferrule and Fittings Maximizing Inertness Inlet connections Recommended: Inert Flow Path: Nut Nut 5190-6194 Column nut,self Tightening Inlet/Detect 05921-21170 Column nut for long ferrule Ferrule Ferrule 5181-3323 Ferrule, 0.4mm VG 0.1-0.25 col 10/PK G3188-27501 Ferrule, flexi inert 0.25mm col 10/PK 5062-3514 Ferrule, 0.5mm VG 0.32 col 10/PK G3188-27502 Ferrule, flexi, inert 0.32mm col 10/PK Tools: Tools G3440-80217 Column install pre- swaging tool, graphite ferrules G3440-80218 Column install pre- swaging tool, metal ferrules G3440-80217 / G3440-80218 26

Inert Flow Path for the 7890B GC / 5977A MSD 27

NOW IT S EASIER THAN EVER TO GET RELIABLE GC RESULTS THROUGH BETTER GC CONNECTIONS FROM AGILENT www.agilent.com/chem/bettergcconnections Order the poster View the video 28

Acknowledgements Agilent colleagues Lindy Miller Yun Zou Gary Lee Paul Trip Roger Firor You for your kind attention 29

Questions? 30