User Manual April 2015

Similar documents
User Manual November 2014

Bold Line Top Stage Incubator

Single UNO. Incubator. .com. Main Features: Incubating chamber. of a Multi Well plate. Manual Air/CO 2 mixer. operation.

UNO-COMBINED-CONTROLLER. CO 2 Microscope Electric Top Stage Incubation System. Manual. Vers

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

QE-1, Rev Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

User s Guide. CO2 Controller for miniature incubators

User s Guide. Vacuum Controller for liquid delivery systems

User s Guide. Pressure Controller for liquid delivery systems

Bold Line Cage Incubator

Microfluidic Demonstration

Installation Instructions RB 500 Motorized Roller Shades Motorized Roller Shade W/ Fascia Series-Motor Operation...

Linkam Scientific Instruments USER GUIDE. LTS420 and LTS120. Temperature Controlled Stage

User s Guide. CO2 & O2 Controller for miniature incubators

Linkam Scientific Instruments USER GUIDE

Linkam Scientific Instruments USER GUIDE TST350. Temperature Controlled Tensile Stress Testing Stage

Instruction Manual. Model DSP-Ex Portable Dewpoint Meter. Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England

BPS-2, Rev TABLE OF CONTENTS

Linkam Scientific Instruments USER GUIDE DSC600. Temperature Controlled Stage

NHR Powder Feed Hopper

Flashlight. Hand Lanyard. 36 Super Bright LED Bulbs. Sensor

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

Flow control valves Series RFU - RFO 2/

Installation, operating and maintenance Instructions for Seemag bypass level indicator

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

2016 Road Electronic Frame Fit Specifications This document is intended to communicate general frame fit guidelines for SRAM electronic products.

Armatures for analytical probes

NHR-X-X Encore Feed Hoppers

ShellPa. Standard Mechanical Cell Stretch System Model No: NNMS Serial #: User Manual

H301-T-UNIT-BL-PLUS Electric Top Stage Incubation System Manual

TTL Converter for Nikon DSLR with Nikonos N5 Connector (Version 2)

Pressure Dump Valve Service Kit for Series 3000 Units

Animal Bed Mouse Cryo

DGT-CO2BX, Digital CO 2 Controller. Manual

INSTALLATION MANUAL JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. Before installation. Installation INSTALLATION MANUAL: B700

Paddle Bar Replacement

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

THE RC-26GLP CHAMBER RC-26GLP RC-26G

Quadair. Air Hockey Table Owners Manual. Assembly operation and care instuctions. Serial # Distributed By. Sales Person. Technical Service #

MEC OEM. User Manual. Commercial in Confidence

SERIES 20 CHAMBERS THE RC-26, RC-26P AND RC-26G CHAMBERS ASSEMBLY

QRPGuys Single Lever Paddle w/base

LEAK TROUBLESHOOTING

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR DETERMINING THE LIQUID LIMIT OF SOIL

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

e.do Gripper Safety requirements, technical features and assembly and integration instructions

9A5N Solid State CW Paddle

How to calibrate the formaldehyde sensor within a PPMonitor Wireless Unit:

screw fittings - nickel plated brass series SC

TECHNICAL INFORMATION

INSTRUCTION MANUAL. January 23, 2003, Revision 0

MJB4 Mask Aligner Operating Procedure. Effective Date: 07/12/2012 Author(s): Jiong Hua Phone:

Animal Bed Rat Cryo. User Manual. Innovation with Integrity. Version MRI

SERIES 20 CHAMBERS THE RC-20 AND RC-20H CHAMBER ASSEMBLY

SCOUT DECK ANCHOR 3 1/4" BONDING SCREW

Linkam Scientific Instruments USER GUIDE TST350. Temperature Controlled Tensile Stress Testing Stage

SI-F971A. 9-speed super narrow chain such as CN-7700 / CN-HG92 8- / 7- / 6-speed narrow chain such as CN-HG50 / CN-IG51

Vacuum grease can be applied to Warner chambers by use of a small artist s dotting brush or a syringe. Both approaches are described below.

Pressure regulators Manually operated Fine setting valves. Brochure

INSTALLATION INSTRUCTIONS

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

Disassembling and assembling APP and APP 16-22

Linkam Scientific Instruments USER GUIDE DSC600. Temperature Controlled Stage

Vacuum grease can be applied to Warner chambers by use of a syringe or a small artist s dotting brush. Both approaches are described below.

Technical Service Bulletin 10001

PRO SINK -R 1 and 2. Dilution system CONTENTS

Flat Bench. Use various tools and clamps in process of welding, so you could weld the items together with accuracy.

Application of vacuum grease

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

INSTALLATION INSTRUCTIONS

RG1200 Service and Repair Manual

SGY-PM910H2/HL/LR ChainRing Adapter Installation Manual

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

Cantilever Brake. Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike

User Manual MFCS TM -EZ

SERIES 20 CHAMBERS THE RC-25 AND RC-25F CHAMBERS ASSEMBLY

STATIONARY TRUCK INTERNAL HALYARD V-CLEAT FLAGPOLES FOR QUICK AND PROFESSIONAL INSTALLATION READ ALL INSTRUCTIONS BEFORE PROCEEDING

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

Basic Flows in a Microfluidic Device

EVO Solid Downtube. Operators Manual for Downtubes fitted with zinc plated springs June 2004

Shifting Lever. RAPIDFIRE Plus 11-speed

Variable Temperature Storage Dewar Mount Inserts

Underwater Housing for Panasonic Lumix DMC-ZS60, DMC-TZ80

GHC Remote Control Instructions manual

Basketball Instructions

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

INSTALLATION INSTRUCTIONS

Model # HC-MIS INSTRUCTION MANUAL

SUMMITTM 475 & 675. Natural Gas Barbecues. Step-By-Step Guide THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY.

Universal Gage. Multimar 844 T

Cyclops + Cyclops + Written By: John Bamford e3d-online.dozuki.com/ Page 1 of 18

INSTALLATION INSTRUCTIONS

Pressure Dump Valve Service Kit for Series 2300 Units

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

INSTALLATION INSTRUCTIONS

Miniball Coulomb Excitation Target Chamber

Nerf N-Strike Elite Strongarm Spring Piston Chamber Replacement

Design Based Anchoring 2009 FORD F-150

RC 195 Receiver-Controller

Transcription:

Page1 Compatible with the following XY stages Compatible with the following Okolab Controllers XY stage model and serial number must be specified in purchase order. H201-T-UNIT-BL

Page2 Index 1. Components and dimensions... 3 2. Sample Holders... 4 2.1 Available Sample Holders... 4 3. Insertion of the Sample Feedback Temperature Sensor... 5 4. Insertion of Sample Holder into Chamber... 5 5. Magnetic Locks... 7 6. Working with 1x3 and 1x2 chamber slides - magnetic locks... 9 7. Connection of the Gas Supply...10 8. Working with Perfusion...10 9. Connection of the Chamber with stage...11

Page3 1. Components and dimensions H301-UP includes the following components: Chamber base Chamber body, it owns 12 holes for the insertion of perfusion tubing up to 2.0 mm Objective adapter, the dimension and type of objective in use must be specified in the purchase order. Holder, the type of stage on which the chamber will fit must be specified in the purchase order. Lid, it features a hinge system allowing to open and close the Lid surrounding the objective. Objective adapter Lid Chamber Body Side View Sample Holder-Order Separately Chamber base Chamber top view Holder Figure 1. H201 UP Components and Dimensions.

Page4 2. Sample Holders 2.1 Available Sample Holders The following sample holders are available. NOTE: Please contact info@oko-lab.com if you cannot find the sample holder you are looking for. We are constantly adding new inserts to the list. UP-1x35-M UP-14xGS-M UP-1xLABTEK-M UP-1xLABTEK-II-M UP-1x60-M #1 35mm Petri-dish #1 1x3in. chamber slide #1 Lab-Tek 1in.x2in. chambered cover glass #1 Lab-Tek II 1in.x2in. chambered cover glass #1 60mm Petri-dish UP-1x35-M For #1 35mm Petri-dish holder UP-1x60-M For #1 60mm Petri-dish holder UP-1xGS-M For #1 1 x3 chamber slide holders UP-1xLABTEK-M For #1 1 x2 Labtek chambered cover glass holder UP-1xLABTEK-II-M For #1 1 x3 chamber slide and #2 35mm petri dishes Figure 2.Available sample holders.

Page5 3. Insertion of the Sample Feedback Temperature Sensor Insert the Sample Feedback Temperature Sensor through the dedicated opening located in the main body (see Figure 3, Frontal and 3D views). Temperature Sensor dedicated opening Temperature Sensor dedicated opening 1.Frontal view 2.3D view Figure 3. Insertion of the temperature sensor inside the chamber. 4. Insertion of Sample Holder into Chamber Sample holders fit into the chamber base and are held in place by magnets embedded within both on the chamber and on the holder. To introduce a sample holder with the proper orientation, match the red dot on the holder to the one on the chamber base, as illustrated in Figure 4. Insert the adapter by superimposing the red dots Figure 4. Introduction of the Specimen Holder inside the Chamber Base. If you want to change the sample holder follow the steps shown in the images of Figure 5 and listed below: 1. Open the lock spring, as shown in Figure 5 Image 2 2. Open the chamber lid as shown in Figure 5 Image 3 3. Remove the chamber lid by lifting it from the workspace, as shown in Figure 5 Image 4

Page6 4. Remove the chamber by lifting it from workspace, as shown in Figure 5 Images 5 and 6 5. Lift and replace the sample holder, as shown in Figure 5 Image 8 1 2 A 3 4 5 6 7 Figure 5. Introduction of the Specimen Holder inside the Chamber Base.

Page7 5. Magnetic Locks Magnetic locks prevent movement of 35 and 60 mm dishes inside the sample holder. Figure 6 illustrates the available magnetic locks for 35 and 60 mm dishes. Threaded magnetic posts allow adjusting holder s height. Magnetic Locks for 35 and 60 mm petri dishes. Included in the corresponding sample holder Figure 6.Magnetic locks for 35 and 60 mm dish NOTE: Magnetic locks are included with sample holder. Spacing rings with variable diameter are also included in according to the needs of the user. Figure 7 shows how to position the ring inside the sample holder. Ring selection guide diagrams: rings for 35 and 60 mm dishes -Figure 8 and Figure 9, respectively. 1 2 3 Figure 7. 1) Insertion of the ring, 2) insertion of the 35 mm dish, 3) insertion of the magnetic lock. NOTE: Spacing rings are included with sample holder.

Page8 Grainer-Petri35x10 Ibidi μ-dish35mm-low BD Falcon-35x10 Willco-35x10 Corning-35x10mm MatTek-P35G-X-14-X Figure 8. Ring selection scheme for 35 mm dish. Ibidi μ-dish 50mm-low MatTek-P50G-X-30-X BD Falcon 60x15 Grainer - Petri 60x15 Corning-60x15mm Willco60x15 Figure 9. Ring selection scheme for 60 mm dish.

Page9 6. Working with 1x3 and 1x2 chamber slides - magnetic locks Magnetic locks prevent movement of 1 x 3 and 1 x 2 chamber slides inside of the sample holder. NOTE: Magnetic locks are included with sample holder. 1 2 Figure 10. Magnetic lock for 1'' x 3'' chamber slide. 1 3 2 Figure 11. Magnetic lock for 1'' x 2'' chamber slide. To lock the slide, push simultaneously the buttons indicated with (3).

Page10 7. Connection of the Gas Supply A single silicon tubing carries output gas from the Okolab Gas Controller to the. Silicon tubing connects to a gas input - brass opening - located on a corner of the. See Figure 12. Connect by gently pushing silicon tubing onto brass opening. Gas Input 8. Working with Perfusion Figure 12.Connection with gas supply. The features 12 perfusion holes on the sides for the insertion of perfusion tubing up to 2.0 mm in outer diameter. Small screws plug the perfusion holes when not in use. (Grub screws M3x6). Remove small screws as necessary before introducing perfusion tubing. Figure 13 shows the location of perfusion holes. Perfusion dedicated opening 1.Frontal view 2.3D view Figure 13. Perfusion

Page11 9. Connection of the Chamber with stage fits on the stage. To fix the chamber on the stage, follow the steps shown in Figure 14 1. Place the holder on the stage and fix it by the four pan head screws M2.5x6 (the screws type depends on the working stage). The place of the pan screws is indicated by letter A.(See Figure 14 Image 1). 2. Place the chamber on the stage and fix it by the four pan head screws M2x4 (the screws type depends on the working stage). The place pan screw is indicated by letter B.(See Figure 14 Image 2). 1 2 Screw M2.5x6 Screw M2x4 A B A B Figure 14. How to fix the H301-UP on the stage