Strategies for concrete confinement with strips of CFRP sheet

Similar documents
SHEAR PERFORMANCE OF RC FOOTING BEAMS BY CAP-TIE SYSTEM USING WELDED STIRRUPS

Research on Shear Test methods of bonded steel bolts

Static and Dynamic Behaviour of the VersaBolt. Presented by Denis Champaigne VP Technical Services MMTI

DYNAMIC CRUSH TEST ON HYDROGEN PRESSURIZED CYLINDER

Tightening Evaluation of New 400A Size Metal Gasket

Prof. B V S Viswanadham, Department of Civil Engineering, IIT Bombay

Reinforced Soil Retaining Walls-Design and Construction

The Adequacy of Pushover Analysis to Evaluate Vulnerability of Masonry Infilled Steel Frames Subjected to Bi-Directional Earthquake Loading

Mechanical Stabilisation for Permanent Roads

Behavior of Square Footing Resting on Reinforced Sand Subjected to Static Load

Pushover Analysis of 4 Storey s Reinforced Concrete Building

CHAPTER 5: VACUUM TEST WITH VERTICAL DRAINS

La inclusion del HRF como material con fines estructurales en el nuevo Codigo Modelo 2010

Displacement-based calculation method on soil-pile interaction of PHC pipe-piles

APPLICATION OF PUSHOVER ANALYSIS ON EARTHQUAKE RESPONSE PREDICATION OF COMPLEX LARGE-SPAN STEEL STRUCTURES

SEALANT BEHAVIOR OF GASKETED-SEGMENTAL CONCRETE TUNNEL LINING

Pushover Analysis of Water Tank Staging

Calibration and Validation of the Shell Fatigue Model Using AC10 and AC14 Dense Graded Hot Mix Asphalt Fatigue Laboratory Data

Non-Linear Seismic Analysis of Multi-Storey Building

A Study on the Eccentric Loading of K Node of Steel Tube Tower

Analysis of dilatometer test in calibration chamber

Investigation of Stresses in Ring Stiffened Circular Cylinder

Vibrations of table tennis racket composite wood blades: modeling and experiments

Figure 1 - JPIF proposal for ISO standardisation of the CAI test method

[Barve, 4(7): July, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

RELATIONSHIP BETWEEN STRUCTURE AND MECHANICAL PROPERTIES OF BRAIDING GOLF SHAFTS AND KANSEI

Analysis of Shear Lag in Steel Angle Connectors

PUSHOVER ANALYSIS OF STEEL STRUCTURE Santosh shet 1, Dr.Akshatha shetty 2 1

A Study on the Punch Shape for Improving Tool Life in Shearing AHSS

INFLUENCE OF FLY ASH IN STRENGTH CHARACTERISTICS OF COHESIVE SOILS

Drop Weight Testing on Sandwich Panels with a Novel Thermoplastic Core Material

Presented to the International Technical Rescue Symposium, November Abstract

A New Test Setup for Testing Polyethylene Tubes under Constant and Cyclic Internal Pressures

Materials Selection Lab Report

Elastic-Plastic Finite Element Analysis for Zhongwei--guiyang Natural Gas Pipeline Endangered by Collapse

Influence of Settlement on Bearing Capacity Analysis of Shallow Foundations on Sandy Clays in the Niger Delta, Nigeria

Vertical Uplift Capacity of a Group of Equally Spaced Helical Screw Anchors in Sand

AN EXPERIMENTAL STUDY ON BUBBLE DECK SLAB SYSTEM WITH ELLIPTICAL BALLS

EXPERIMENTAL ANALYSIS OF MECHANICAL PROPERTIES OF SELECTED TAKRAW BALLS IN MALAYSIA

2.1 Introduction to pressure vessels

Pushover Analysis of G+3 Reinforced Concrete Building with soft storey

BASIC REQUIREMENTS FOR FIBER REINFORCED PLASTIC (FRP) TYPE 3FC COMPOSITE CYLINDERS

Effect of Depth of Periphery Beams on Behavior of Grid Beams on Grid Floor

Application of pushover analysis in estimating seismic demands for large-span spatial structure

Effect of a Backplate Using in Electromagnetic Induction Method for Permittivity Measurement

Influence of Fly Ash Content on Compaction Characteristics of Fly Ash Clay Mixture

Technological Innovations in Progress of Pole-vault Performance

STUDY OF UNDERWATER THRUSTER (UT) FRONT COVER OF MSI300 AUTONOMOUS UNDERWATER VEHICLE (AUV) USING FINITE ELEMENT ANALYSIS (FEA)

Multi-directional Vibration Analysis of Cricket bats

High-Energy Ship Collision with Jacket Legs

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

TenCate TC275-1 PRODUCT DATA SHEET DESCRIPTION FEATURES NEAT RESIN PROPERTIES PRODUCT TYPE TYPICAL APPLICATIONS SHELF LIFE

Liquefied gas cargo tanks and process pressure vessels

Hermetic Compressor Manifold Analysis With the Use of the Finite Element Method

Linear Compressor Suction Valve Optimization

Applicability of Nonlinear Static Procedures to RC Moment-Resisting Frames

Seismic Response of Skewed RC Box-Girder Bridges

Experimental Method to Analyse Limit Load in Pressure Vessel

Notice for Pressure Special Equipment Manufacture Licensing

Adaptive Pushover Analysis of Irregular RC Moment Resisting Frames

Pushover analysis with ZSOIL taking soil into account. Stéphane Commend GeoMod Ing. SA, Lausanne

Session 1. Pushover Analysis of a Torsionally Eccentric Cellular Abutment. Date 11/03/ PM 4 PM Eastern Time

DOT-CFFC BASIC REQUIREMENTS (FIFTH REVISION) PAGE 1

Study on Stress Analysis of Araldite HY-951 and CY-230 Bell Crank Lever using Photoelasticity and FEM

Module 7 Lecture 1. Swelling and Collapse Behavior

Session on applications: HRS - refuelling. P. Moretto

Bottom End-Closure Design Optimization of DOT-39 Non-Refillable Refrigerant Cylinders

Composite tubing collapse under uniform external hydrostatic pressure

An Investigation into the Relationship between Wood Bat Durability and Bat Taper Geometry using LS-DYNA

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Influence of effective stress on swelling pressure of expansive soils

Impact Fatigue on Suction Valve Reed: New Experimental Approach

SIMULATION OF ENTRAPMENTS IN LCM PROCESSES

Wind Pressure Distribution on Rectangular Plan Buildings with Multiple Domes

STRUCTURAL ANALYSIS OF THE VACUUM VESSEL FOR THE LHCb VERTEX LOCATOR (VELO)

Newport 301 Product Data Sheet

ASSESSMENT AND ANALYSIS OF PIPELINE BUCKLES

The Relationship between the Depth Embedded Pipe Pile and the Force of Clamping Jaw

Modeling of thin strip profile during cold rolling on roll crossing and shifting mill

machine design, Vol.6(2014) No.3, ISSN pp

Impact Test Equipment Ltd & User Guide. User Guide

Optimization of rotor profiles for energy efficiency by using chamber-based screw model

Analysis and Design of Elevated Intze Watertank and its Comparative Study in Different Wind Zones - using SAP2000

Using Experimental Procedure to Improve the Efficiency of the Two Stand Reversing Cold Mill

Illinois Center for Transportation

Residual Stresses in Railway Axles

EFFECT OF INCORPORATED LUBRICATION ON THE TRIBOLOGICAL PROPERTIES OF POLYAMIDES

Other Si min/max. Cr min/max. 0.4/ / / / Bal.

Bearing Capacity and Settlement Response of PMS Tanks on Cohesionless Soil Lithology in Lekki, Lagos of Nigeria

Effect of Shear Span to Depth Ratio on Shear Strength of Steel Fiber Reinforced High Strength Concrete Deep Beam using ANN

Study to Establish Relations for the Relative Strength of API 650 Cone Roof Roof-to-Shell and Shell-to- Bottom Joints

Collapse of composite tubes under uniform external hydrostatic pressure

Critical face pressure and backfill pressure in shield TBM tunneling on soft ground

EXPERIMENTAL INVESTIGATION ON OPTIMUM INSTALLATION DEPTH OF PVD UNDER VACUUM CONSOLIDATION ABSTRACT

Wind Action Effects on Mixed Reinforced Concrete Structures in Non Seismic Zones

RESEARCHES UPON THE TENSILE STRENGTH AND ELONGATION AT BREAK OF THE LEATHER SUBSTITUTES

External Pressure Coefficients on Saw-tooth and Mono-sloped Roofs

Stress Analysis of The West -East gas pipeline with Defects Under Thermal Load

STIFFNESS INVESTIGATION OF PNEUMATIC CYLINDERS. A. Czmerk, A. Bojtos ABSTRACT

For a cantilever pile wall shown in Figure 1, assess the performance of the system and answer the following questions.

Transcription:

Strategies for concrete confinement with strips of CFRP sheet D. Ferreira Technique Institute, Campus de Santa Apolónia, Apartado 8, -8 Bragança, Portugal J. Barros Dep. of Civil Engineering, University of Minho, Campus de Azurém, 8-8 Guimarães, Portugal ABSTRACT: To increase the strength and the energy absorption capacity of concrete elements submitted to compression loading, concrete cylinder specimens of mm diameter and mm height were confined with strips of wet lay-up carbon fiber sheet (CFRP). To assess the influence of the width and number of CFRP strips, and the number of CFRP layers per strip in the concrete compression strength and ductility, distinct confinement arrangements were applied. The main results obtained are presented and analyzed in the present work. INTRODTION Earthquakes in urban areas have repeatedly demonstrated the vulnerabilities of older reinforced concrete columns to seismic deformations demands, (Xiao et al. 999). The full wrap of the concrete column with Carbon and Glass fiber reinforcement polymer (CFRP, GFRP) sheets is a general practice to increase the load bearing capacity, the ductility and the shear strength of this type of structural elements (CEB-FIB, ; Seible et al., 99, Mirmiran e Shahawy, 99; Untiveros, ). In spite of the success attained by the application of C(G)FRP confinement systems on laboratory specimens, on prototypes and on real applications, the knowledge of the confinement mechanisms involved are not yet quite assessed and the experimental results available for developing design guidelines are not sufficient. The present work aims to contribute for the knowledge in this area. CONFINEMENT SYSTEMS The confinement systems adopted are represented in Figure a and Table. Figure b to f includes photos of representative specimens of some of these confinement systems. They are composed by strips of CFRP sheet bonded to concrete and to subjacent layers by epoxy resin. The influence of the strip width, W, the number of strips along the specimen, S, and the number of CFRP layers per strip, L, on the specimen compression behavior was analyzed. The series indicated in Table were tested, each one was composed by three specimens. Varying W, S and L led to series of different confinement ratio ( f = A f /A c,t ), where A f = S W L. mm is the cross section area of the confinement system (according to the manufacturer, the CFRP has. mm of thickness) and A c,t = mm is the longitudinal section of the cylinder specimen ( mm width by mm height). Each specimen is designated by WiSjLk, where i is the strip width, j is the number of strips along the specimen and k is the number of CFRP layers per each strip. A detailed description of the confinement arrangements and procedures are given elsewhere (Ferreira and Barros ). MATERIALS From uniaxial compression tests carried out at 8 days with concrete cylinder specimens of mm diameter and mm height, an average compression strength of MPa was obtained. The wet lay-up carbon fibre sheet used has the trade name of Mbrace C-. According to the supplier, the Mbrace C- is. mm thick, can attain a tensile strength higher than MPa, an elasticity modulus in the fibre direction of about GPa and an ultimate strain of about.

Table Test series t W S L [mm] [-] [mm] - 8 - [-] [mm] [%]........9. 9.8..... 9.8......9..9....8...... Specimen designation WSL WSL WSL WSL WSL WSL WSL WSL WSL WSL WSL WSL WSL WSL WSL WSL WSL..8 WSL.... WSL WSL 8.. WSL 8....8 WSL WSL.8.9 WSL 8....8 WSL WSL..9 WFL..8. WSL WSL.. WSL Af f Conf.s ystem EQUIPMENT AND MEASURING DEVICES Three LVDTs were used to evaluate the specimen axial deformation. To decrease the confinement effect on the specimen, a teflon system was applied inbetween the platens of the testing rig and the specimen extremities. Strains in the fiber direction of the CFRP strips were measured by strain gauges (SG) placed at half height of the strip, accordingly to the arrangement represented in Figure. A detailed description of the test equipment and test procedures can be found in (Ferreira and Barros ). RESULTS Figure shows the relationship between concrete stress and specimen axial strain on specimens of series WS and WS. The concrete stressspecimens' axial strain-cfrp strain relationship of the remainder series is depicted in Figure. Each curve represents the average response registered on the three specimens that compose each series. The concrete stress is the ratio between the applied load and the specimen cross section. From the analysis of the graphics of figure a and a it is verified that the confinement system of series WS was not effective, and the confinement system of series WS provided an increase on the energy absorption capacity, but the maximum stress did not exceed the strength of the corresponding unconfined concrete (). In series WS the maximum strain in the CFRP increased with the number of layers per each strip. From Figure b it is verified that, after the strain at peak stress of series ( cp), the specimens of series WS with three or more CFRP layers per each strip had a hardening branch. WSL W t/ W a) t t W t/ WSL WSL b),,,,8 SG e) f) d) Figure - Generic confinement system and photos of some adopted confinement systems., a) WSL SG, c) SG WSL WSL WSL WSL WSL WSL,,,,8, Figure Stress-axial strain relationship.,,, b)

WSL WSL WSL WSL WSL WSL WSL WSL WSL WSL Stress(MPa) -, -,,,, Strain on CFRP (mm/mm) WSL WSL WSL WSL WSL WSL -, -, -,,,,,,, Strain on CFRP (mm/mm) b). WSL_ext WSL_ext WSL WSL WSL_ext WSL_ext -, -,,,,,, Strain on CFRP (mm/mm) Axial. strain(mm/mm) c) WSL_ext 9 WSL_ext WSL_ext WSL 8 WSL WSL_ext WSL WSL_ext WSL_ext -, -,,,,,,,, Strain on CFRP (mm/mm) 9 WSL 8 WSL WSL WSL WSL WSL -, -, -,,,,,,, Strain on CFRP(mm/mm) Axial strain(mm/mm) WSL WSL WSL WSL 8 WSL -, -,,,,,,,, Strain on CFRP(mm/mm) f) Figure Stress-axial strain-cfrp strain relationship. a) d) e) In specimens confined with strips of width larger than mm, not only the energy absorption capacity increased significantly, but also the load bearing capacity. After cp, the load bearing capacity of specimens confined with three strips of mm width (WS, Figure b) increased smoothly with the specimens' axial deformation up to its failure. In this series the increase on the load bearing capacity was more pronounced from three to five layers per strip, than from five to seven layers. In specimens confined with four strips of mm width (WS, Figure c) after cp the stiffness of the deformational response increased significantly with the number of layers per each strip. The maximum strains in the two CFRP strips of the series confined with three layers per strip were similar, having attained a value of about., which corresponds to % of the CFRP ultimate strain ( fu ). In specimens of five layers per strip, the maximum strain on the top strip (SG, Figure e) was larger ( ) than the strain on the bottom strip (SG,. ). This was due to the larger concrete dilatancy occurred on the top part of these specimens. In specimen with four strips of mm width (WS, Figure d) it was observed a behavior similar to the one of series WS. However, series WS provided a larger increase on the load bearing capacity and on the energy absorption capacity. For more than layers per strip, the benefits in terms of load and energy increment were marginal. The maximum strains decreased with the increase of the number of layers per each strip. In series with five and seven layers per strip, the maximum strains on top and on bottom strips were similar, while in series with three layers, the maximum strain in the top strip was again larger than the maximum strain in the bottom strip. In series WS the maximum strain in the CFRP was about 8% of the fu. In spite of series WS and WS have equal f, they have provided different levels of confinement. Series WS assured a larger increment on the load bearing capacity, revealing that, for this purpose, the number of strips is more influent than the width of the strip. However, the largest values of the maximum strains in the CFRP were registered in series WS. In series of full wrapping (WS, Figure f) above five layers per each strip the increase on the load bearing capacity and on the energy absorption capacity was marginal. In these series it was also observed a decreasing of the maximum strain in CFRP with the number of layers. Table summarizes the results obtained, where max is the maximum concrete compression stress (in series of specimens, max represents the average

value of the concrete compression strength, f c ), cfp is the axial strain corresponding to max (in series of specimens cfp = cp ) and fmax is the maximum strain in the CFRP. To graphically represent the efficacy of the confinement systems in terms of increasing the load bearing capacity and the energy absorption capacity, it was obtained the σ/f c - f and - f relationships, represented in Figure and, respectively, for different levels of relative axial strain of confined specimens, / cp, namely, / cp =,,, e 8. U is the exceeding energy provided by the confinement arrangement and Uc is the energy dissipated in the deformation of the unconfined specimens up to a strain of., see Figure. From the analysis of the values included in Table and from the curves represented in Figure, it was verified that: the load bearing capacity increases with f ; confinement systems of f <. did not provide an increase on the load bearing capacity of the corresponding series; it was not effective to apply more than layers per strip; in the confinement systems made by strips of mm width, the increase of the load bearing capacity was only significant in series of five strips of six layers per strip (increase of %); in series WS the increase of the load bearing capacity was 9%, 8% e % for three, five and seven layers per strip, respectively; in series WS the increase of the load bearing capacity was 8% and % for three and five layers, respectively; comparing the results obtained in series WS and WS it was verified that, for the purpose of increasing the load bearing capacity, it is more efficacy to decrease the distance between strips than increase the number of layers, as more volume of concrete is effectively confined. This conclusion can also be extracted analyzing the results obtained in series WS and WS that, despite having the same percentage of CFRP, the load bearing capacity was higher in series WS, whose distance between strips was mm, while in series WS was mm; in series WS the increase of the load bearing capacity was %, % e % on specimens with three, five and seven layers per strip, respectively; the compression strength of unconfined concrete can be duplicated using one of the following confinement systems: WSL, WSL, WS; the cfp / cp was increased with the confinement percentage, f. Up to f =., cfp / cp was less than three. For f >., cfp / cp increased significantly, having attained a maximum value of nine. It should be emphasized that, as the load bearing capacity of the equipment was limited to kn, the failure load of some confined specimens was not attained, by the way, the values of the cfp / cp ratio and the maximum load of these specimens would be larger than those registered. The maximum strain in the CFRP ranged from % to 8% of the CFRP ultimate strain, fu. WS was the series with more homogeneous values, with a variation from % to % of the fu........ /cp= WS WS WS WS WF.. ρf..8 /cp= WC WS WS WS WS.. ρf..8 /cp= WS WS WS WS......8 ρf /cp= WS WS WS WS ρf /cp=8....8 WS....8 ρf WS Figure σ/f c versus confinement percentage (ρ f ) σ f'cc f'c unconfined concrete Uc U FRP failure confined concrete cp. cfp Figure Stress-strain model in compression for calculation of ultimate concrete strain

...8. /cp= WS WS WS WS WS WS.. /cp= WS WS WS WS WS WS.. /cp= 8 WS WS WS WS WS.. /cp= WS WS WS WS WS.. /cp=8 WS WS WS....8 Figure - Normalized increment of energy () versus confinement percentage (ρ f ), at five / cp levels From Figure the following observations can be pointed out: the energy absorption capacity increased with ρ f, but the increment ratio decreased with ρ f ; the increment of was more pronounced in series WS and WS; for a strain level twice the strain corresponding to the strength of unconfined specimens (/ cp =) is only a little bit higher than the unit value. For / cp =8 a of about was attained; in series WS and WS, of equal ρ f, series WS was more efficacy in terms of energy absorption capacity; for equal ρ f, the efficacy of series WS was similar to the series WS (full wrapping); for / cp =8 the energy absorption capacity of specimens of series WS was not increased with the increase of ρ f (increase the number of layers per strip from five to seven); for a strain level near (/ cp =), which can be expected in some reinforced concrete elements of structures submitted to seismic loading, varied between the limits of about and, which is important in terms of safety. CONCLUSIONS In the present work the compression behavior of concrete cylinder specimens confined by strips of wet lay-up carbon fiber sheet (CFRP) was analyzed, carrying out uniaxial compression tests under displacement control. The strips were differently arranged for leading confinement configurations that can reveal the relative importance of the number and width of the strips, and the number of layers per strip, on the increase of the load bearing capacity and on the energy absorption capacity. From the analysis of the results obtained it was observed that, the compression strength of unconfined concrete specimens was only exceeded on series with CFRP confinement percentage, f, larger that.. In series with f <., only the energy absorption capacity was increased. Increasing the number of CFRP layers, the load bearing capacity and the energy absorption capacity were increased in all series. However, above five layers per strip, the increase was not so significant than the increase registered up to five layers. The influence of the strip width and the number of strips on the confinement level attained is related to the free space of concrete between CFRP strips. In series of equal f, larger increase of the load bearing capacity and ductility was observed in series with lower distance between CFRP strips. This is due to the fact that the concrete damage was concentrated in these gaps. In general, the maximum strain in the CFRP decreased with the increase of the number of layers per strip. The load bearing capacity of unconfined concrete specimens of compression strength ranged from to MPa can be doubled using one of the following confinement systems: four strips of mm width and four layers per strip; three strips of mm width and five layers per strip; full wrapping with two layers.

Table - Main indicators of the efficacy of the confinement systems ρ Specimen designation S L f σ max σ max /f c cfp [%] (MPa) (µm/m) cfp / fmax cp (µm/m) fmax / fu Unconfined concrete - - - - - - - - WS.E-. - - - -.E-. - 88 - - -.E-.8-98 - - -.E-.8 - - - -.8E- 8.8-98 - - - Unconfined concrete - 8. (f c). 98 ( cp). - WS.E-.. 9...8.8E-.. 8.8.9..E-.. 8. 99...E-..9 8. 88.9.9.E-.. 98. 8.. Unconfined concrete -.8 (f c). 9 ( cp). - WS.E- 9..9. -.E- 9.8.9 9. -.E-.. 88. -.E-.. 999. -.E-...8 - Unconfined concrete -. (f c). 8 ( cp). - WS.E- 8.8.9.9..8.E-..8. 8...8E-.. 8. 8..8 Unconfined concrete - 8.8 (f c). ( cp). - - WS.E-.8.8.9.E-... Unconfined concrete - 9. (f c). 9 ( cp). - WS.E-.99.8 8..8E- 9.. 89 8. 9.E- 9.8. 9 8.9 Ext- 99.. Ext- 9.. Ext-. Ext- 9.. Ext- 8.. Ext-.9. Ext- 9.. Ext-.. Ext-.. Ext- 9.. Unconfined concrete -. (f c). ( cp). -.E-.8. 8... WS.8E- 9.8.98 8 8..9.9 9.E- 8..9 9 8.8..9 Unconfined concrete -. (f c). 8 ( cp). -.8E- 8.. 9.8 - - WS -.E 9.98.. 98..E 99.8..8 8. ACKNOWLEDGMENTS The authors wish to acknowledge the supports provided by Bettor MBT Portugal and S&P Clever Reinforcement. REFERENCES CEB-FIB, Structural Concrete- textbook on behaviour, design and performance, vol., July 999. Ferreira, D., Barros, J., Mantas de CFRP no confinamento de elementos de betão sujeitos à compressão (Strips of wet layup CFRP in the confinement of concrete elements submitted to compression), V Symposium EPUSP on concrete structures, S. Paulo, Brazil, June. Mirmiran A.; Shahawy M., Behaviour of concrete columns confined by fiber composites, ASCE Journal of structural Engineering, Vol, nº, pp 8-9, 99. MBTBettor, Master Builders Technologies. Seible, F.; Priestley, M. J. N.; Hegemier, G. A.; Innamorato, D., Seismic retrofit of RC columns with continuous carbon fiber jackets, ASCE, Journal of Composites for Construction,Vol., nº, pp -, 99. Untiveros, C. M. A., Estudio experimental del comportamiento del hormigón confinado sometido a compresión, PhD thesis, UPC, Barcelona, September. Xiao Y. and Wu H., and Martin, G. R., Prefabricated composite jacketing of RC columns for enhanced shear strength, ASCE Journal of structural Engineering, Vol, nº, pp -, 999.