NZQA unit standard New US 1Non-coal of 7145 version 1 Page 1 of 5

Similar documents
NZQA unit standard 7145 version 9 Page 1 of 5. Design and maintain effective ventilation systems for an underground coal mine

NZQA unit standard version 5 Page 1 of 5. Describe, develop, and maintain basic ventilation systems for an underground coal mine

NZQA unit standard version 3 Page 1 of 8. Manage the mine ventilation system at an extractive site

NZQA unit standard 8916 version 8 Page 1 of 5

IGO GROUP SAFETY STANDARD 30 - WORKPLACE VENTILATION INDEPENDENCE GROUP NL

NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus

NZQA registered unit standard version 3 Page 1 of 6

NZQA unit standard version 1 Page 1 of 6. Describe hazards and apply risk reduction techniques and strategies while driving a bus or coach

VENTILATION. l.l.l. The primary objective should be to reduce emissions of contaminants at source and hence reduce the need for ventilation.

NZQA registered unit standard version 1 Page 1 of 5. Meet requirements for Approved Filler Test Certificate for refrigerants

Proficiency Module Syllabus. P601 - Thorough Examination and Testing of Local Exhaust Ventilation Systems

NZQA unit standard version 1 Page 1 of 5. Demonstrate knowledge of hazardous substances relevant to Certified Handlers

NZQA Expiring unit standard version 2 Page 1 of 5. This unit standard is for people involved with pest control in rural environments.

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

NZQA expiring unit standard version 6 Page 1 of 5. Demonstrate knowledge of electrical safety and safe working practices for electrical workers

Auxiliary ventilation operation practices

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

CONTRACTOR WHS HAZARD STANDARD HAZARDOUS CHEMICALS EXTERNAL USE ONLY

ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN

NZQA registered unit standard version 1 Page 1 of 5. Demonstrate knowledge of health and safety when welding and thermal cutting

NZQA registered unit standard version 3 Page 1 of 7. Demonstrate knowledge of bitumen gangbar sprayers and operations

MINING INQUIRY BOX FLAT COLLIERY REPORT, FINDINGS AND RECOMMENDATIONS

NZQA registered unit standard version 3 Page 1 of 8. Operate bitumen gangbar sprayer transfer, heating, and blending equipment

NZQA registered unit standard 676 version 5 Page 1 of 5

TABLE OF CONTENTS PART 2 - CONFINED SPACES

Chapter 7. Coal Cargoes. Properties and Characteristics 7.1

NZQA Expiring unit standard 8296 version 5 Page 1 of 5

NZQA registered unit standard version 3 Page 1 of 6

The principal mechanism for taking medium air velocity measurement is the Anemometer.

NZQA registered unit standard version 2 Page 1 of 5. Press wood veneer into plywood and laminated veneer lumber

COSAO26 Identify workplace health and safety hazards and control risks in asbestos surveying and analysis

Dangerous Substances and Explosive Atmosphere Regulations 2002 Appendix 2 Detailed assessment & zone classification where DSEAR applies to an area

VENTILATION DURING TUNNEL CONSTRUCTION INDUSTRY CONSIDERATIONS

2018 STATEMENTS OF FACT MINE RESCUE. 1. To test for methane, use a methane detector or chemical analysis.

LECTURE 1 THE CONTENTS OF THIS LECTURE ARE AS FOLLOWS: 1.0 AIRWAYS CONNECTED IN SERIES AND PARALLEL. 1.1 Airways Connected in Series

EUSMUNC06 (SQA Unit Code - FG2W 04) Locate and avoid supply apparatus for Utilities Network Construction

NZQA Expiring unit standard version 7 Page 1 of 8. Demonstrate knowledge of safe working practices in telecommunications.

Safe Work Practices (SWP) SWP (3) CONFINED SPACE ENTRY

NZQA registered unit standard 1269 version 7 Page 1 of 5. Plan, prepare for, and carry out line shifts in a cable harvesting operation

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Describe Flammable Gas Measurement

This document is meant purely as a documentation tool and the institutions do not assume any liability for its contents

NZQA Expiring unit standard version 3 Page 1 of 5. Demonstrate knowledge of the varroa mite and its control in the beekeeping industry

Goaf Inertisation and Sealing Utilising Methane from In-Seam Gas Drainage System

CONFINED SPACES DON T GET STUCK IN A HOLE. CAMERON HUNTER BSc., GradDip (Occ.Hygiene), MSIA Vital Safety Pty Ltd

Installing, Repairing or Modifying Construction Resources by Heating, Welding, Brazing, Soldering and Thermal Cutting in the Workplace L/505/0144

Installation of Ballast Water Management Systems

NZQA Expiring unit standard version 5 Page 1 of 5

Tunnelling. Design Element Health Hazard Considerations Possible Solutions Linked to Ref No.

Guidance on room integrity testing and its interpretation

VENTILATION FOR SINKING VERTICAL, SUB VERTICAL AND DECLINE SHAFTS. D M Walters Turgis Consulting

ATEX and explosive atmospheres

PRODUCT HEALTH AND SAFETY DATA

Ventilation Requirements for Uranium Mines

This standard comprises the following:

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Workplace Safety and Health (Major Hazard Installations) Regulations 2017 S 202/2017

WHS PROCEDURE P Confined Spaces. Approved by: Ruth Hampton Review Date: 6 th December 2015

Forced or Mechanical Ventilation - which uses mechanical supply and/or extraction to provide fresh air and is controllable.

D Lightweight Respiratory Protection

Safety Tips from the WorkSafe People. Building a Safety Program for Your Organization

Guidance: HSW Risk Assessment Methodology HSW-PR09-WI01. Objective. Implementation

Confined Space Policy

Evaluation of the optimum conditions for a local ventilation system in connection with the mine ventilation network

NZQA registered unit standard version 2 Page 1 of 5

MINE VENTILATION AND ENVIRONMENTAL ENGINEERING COURSE Perth, Western Australia 8 th April to 13th April 2018

Bona Naturale Base. Identification of the preparation and of the company

CIVIL INFRASTRUCTURE HEALTH, SAFETY, AND ENVIRONMENT Describe protection of health, safety and environment in the civil infrastructure industry

Airborne Activity Sampling and Monitoring at Hinkley Point A Site. David Williams, Hinkley Point A Site

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

Ventilation optimization at the La Camorra mine

AIDGC PRESENTATION MARCH 2006 HAZARDOUS AREAS STANDARDS & CLASSIFICATION

PSSI 36 General Confined Spaces, Tunnels, Culverts and Similar Spaces

Work Equipment: LOCAL EXHAUST VENTILATION

T.I. Mayes and A.D.S Gillies. A Review of Current Australian Longwall Mine Ventilation Practice, Proceedings, First Mine Environment and Ventilation

Cutting and shaping materials using thermal cutting equipment

Location and Avoidance of Underground Apparatus

Kansas State University Fume Hood Operation

Rockhampton Office Brisbane Office Tarong Site. Barron Gorge Hydro PS Kareeya Hydro PS Mica Creek PS

The routine maintenance and inspection of local exhaust ventilation (LEV)

Introduction to Confined Space Safety OR-OSHA

The Role of Gas Monitoring in the Prevention and Treatment of Mine Fires

Challenges of gas monitoring and interpretation in underground coal mines following an emergency

CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE

Engineering Safety into the Design

SOUTH AFRICAN NATIONAL STANDARD

excavation work and necessary for the exhalation of workers. After conducting the ventilation network analysis, the result should be checked whether t


SAFETY DATA SHEET according to 1907/2006/EC, Article 31

SAFETY AND HEALTH IN THE USE OF CHEMICALS AT WORK

CONTRACTOR WHS HAZARD STANDARD CONFINED SPACE EXTERNAL USE ONLY

PURPOSE To define the minimum requirements for controlling risks associated with persons entering or working in confined spaces.

STORM WATER RETENTION TANKS MAINTENANCE INFORMATION FOR HEALTH AND SAFETY FILE

SAFETY DATA SHEET. Silicon Carbide. 1. IDENTIFICATION OF SUBSTANCES / MIXTURE AND OF THE COMPANY / UNDERTAKING Product Identifiers Product Name:

Faculty/School: Pharmacy Initial Issue Date: Oct 2016

Confined Space Identification & Hazard Assessment

2012 SYLLABUS FOR IFE LEVEL 2 CERTIFICATE FIRE SCIENCE, OPERATIONS AND SAFETY 500/5925/7.

(2) but does not include a shaft, trench or tunnel that is a mine or is part of the workings of a mine.

NZQA registered unit standard 1178 version 7 Page 1 of 6

Transcription:

Page 1 of 5 Title Design and maintain effective ventilation systems for a non-coal underground operation Level 5 Credits 20 Purpose People credited with this unit standard are able to: explain the principles and practices of ventilation; design ventilation circuits, and select and position ventilation control devices; read and interpret a ventilation plan; explain how the ventilation system is established; measure, maintain, and document ongoing air velocity, air quality, and air quantity in a non-coal underground operation; measure gases and mixtures of gases found in a non-coal underground operation, and interpret results and explain the effects; and explain the primary causes and control mechanisms for fires and hazardous atmospheres in a non-coal underground operation. Classification Extractive Industries > Underground Extraction Available grade Achieved Entry information Prerequisites [New non-coal version of 21281], Interpret and test for gases in a non-coal underground operation, or demonstrate equivalent knowledge and skills. Guidance Information 1 Performance of the outcomes of this unit standard must comply with the following: Health and Safety at Work Act 2015 (HSW); Health and Safety at Work (General Risk and Workplace Management) Regulations 2016; Health and Safety at Work (Mining Operations and Quarrying Operations) Regulations 2016; Health and Safety at Work (Worker Engagement, Participation, and Representation) Regulations 2016; approved codes of practice issued pursuant to the HSW Act. 2 Any new, amended, or replacement Acts, regulations, standards, codes of practice, guidelines, or authority requirements or conditions affecting this unit standard will take precedence for assessment purposes, pending review of this unit standard. 3 Joint assessment must be conducted in the assessment of this unit standard because of the high degree of risk.

Page 2 of 5 To conduct a joint assessment, two assessors, or one assessor and one technical verifier, must have witnessed the learner undertaking the tasks required in the unit standard and have come to the same conclusion in regards to the learner being competent or not yet competent. At least one assessor or verifier must hold the unit standard they are assessing on their NZQA Record of Learning. 4 Due to the high degree of risk associated with this unit standard, the assessment process must include a learner interview with one or both assessors. 5 Definitions Company procedures mean the documented methods for performing work activities and include health and safety, operational, environmental, and quality management requirements. They may refer to legislation, regulations, guidelines, standard operating procedures, manuals, codes of practice, or policy statements. Industry best practice may be documented in management plans, control plans, company procedures, managers rules, occupational health and safety policy, industry guidelines, codes of practice, manufacturers instructions, and safe working and/or job procedures (or equivalent). 6 An underground operation includes extractive or tunnelling operations. 7 All evidence for assessment against this unit standard must be in accordance with industry best practice and company procedures. Outcomes and performance criteria Outcome 1 Explain the principles and practices of ventilation in a non-coal underground operation. 1.1 The principles and practices of air movement and gas management in underground operations are explained in terms of effective and ineffective air circulation. includes but is not limited to air movement, gas occurrence,, pressure differential, resistance, effects of temperature, air density, air power, areas, volumes. Outcome 2 Design ventilation circuits, and select and position visual control devices (VCDs) for a noncoal underground operation. 2.1 Design meets requirements of industry best practice and company procedures. 2.2 The gas laws and Atkinson s formula are calculated to demonstrate the design is effective.

Page 3 of 5 2.3 VCDs are selected and positioned on the designed plan to gain optimal atmospheric conditions for underground operation. includes but is not limited to main fans, air intake, return airflow, stoppings, doors, auxiliary fans, design, location. Outcome 3 Read and interpret a ventilation plan for a non-coal underground operation. 3.1 Standard symbols on a ventilation plan are interpreted in accordance with approved mine survey standards. includes but is not limited to main fan, air intake, return airflow, stoppings, doors, auxiliary fan, air mover. 3.2 Mathematical calculations are made and interpreted for a ventilation plan for a non-coal underground operation. Outcome 4 Explain how the ventilation system for a non-coal underground operation is established. 4.1 A VCD s construction is described. includes but is not limited to temporary and permanent materials, timber, fabric, concrete, blocks, shotcrete, mesh, steel, strength. 4.2 The installation of auxiliary ventilation fans and ducting is explained. 4.3 The installation of VCDs is explained. 4.4 The methods for testing the effectiveness and efficiency of the ventilation system and VCDs are evaluated against the intent of the ventilation plan and site requirements. includes but is not limited to pressure differential, air flow quantity and velocity, air leakage, air quality, air power. Outcome 5 Measure, maintain, and document ongoing air velocity, air quality, and air quantity in a non-coal underground operation.

Page 4 of 5 5.1 Air velocity and quantity is measured in accordance with equipment manufacturers specifications. includes anemometer; may include smoke tubes, velometer, pitot tube. 5.2 Air quality is measured in accordance with equipment manufacturers specifications. includes humidity measurement, hand-held gas detection, remote gas detection, thermometer (wet and dry bulb), dust monitoring, diesel particulate matter; may include chemical gas tubes. 5.3 Anomalous readings or readings indicating hazardous situations are reported and recommended actions taken. 5.4 Actions to minimise hazards are implemented and reported. 5.5 Adjustments required to VCDs and equipment to maintain required air flow and air quality are described. 5.6 Documentation is completed. Outcome 6 Measure gases and mixtures of gases found in a non-coal underground operation, and interpret results and explain the effects. may include but is not limited to carbon monoxide, carbon dioxide, oxygen, nitrogen, sulphur dioxide, hydrogen sulphide, oxides of nitrogen, ammonia. 6.1 The type and proportions of gases and mixtures of gases are measured in accordance with instrument specifications. 6.2 The potential hazards of the gas concentrations measured are interpreted in terms of consequences to site and workers. 6.3 Hazards are eliminated and/or minimised. 6.4 The characteristics and behaviour of gases are explained in terms of known gas laws. includes but is not limited to Boyle s law, Charles s law, Combined Gas law.

Page 5 of 5 Outcome 7 Explain the primary causes and control mechanisms for fires and hazardous atmospheres in non-coal underground operations. 7.1 Primary causes of underground fires and hazardous atmospheres are explained in terms of a non-coal underground environment. 7.2 Sources of ignition are explained in terms of a non-coal underground environment. includes but is not limited to frictional ignition, electrical, mechanical, prohibited material, flammable substances. 7.3 Control mechanisms for underground fires and hazardous atmospheres are explained. includes but is not limited to fire fighting methods, emergency responses, fire fighting equipment, neutralising agents. Planned review date 31 December 2022 Status information and last date for assessment for superseded versions Process Version Date Last Date for Assessment Registration 1 Consent and Moderation Requirements (CMR) reference 0114 This CMR can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Comments on this unit standard Please contact info@mito.org.nz if you wish to suggest changes to the content of this unit standard.