If you want to offer a more professional look to your

Similar documents
If you want to offer a more professional look to your

INSTALLATION GUIDE Gas Rangetops

G AS BBQ GRILLS INSTALLATION INSTRUCTIONS

D U A L F U E L R A N G E S

Viking Installation Guide

Installation GUIDE 5 SERIES. Built-in Gas Rangetops VRT530 / CVRT530 VRT536 / CVRT536 VRT548 / CVRT548

Installation. Professional Built-in Gas Rangetops VGRT530, VGRT536,CVGRT530, CVGRT536 VGRT548, CVGRT548

DUAL FUEL RANGES INSTALLATION INSTRUCTIONS. Model Series

DUAL FUEL RANGES INSTALLATION INSTRUCTIONS. Model Series ICBDF304 ICBDF366

ACCESSORY KIT INSTALLATION INSTRUCTIONS

6890 GC Site Preparation

INSTALLATION & OPERATION MANUAL FOR Stockpot Range

Required Indoor Draft Hood. Optional Outdoor Vent Cap

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

GAS CONVERSION KIT Installation Instructions Range/Rangetop

Instruction Manual VCG-6

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Viking Installation Guide

SINGLE OVEN GAS RANGE

GEN-1e CO2 Generator OVERVIEW INSTALLATION PROPANE GENERATORS ONLY NATURAL GAS GENERATORS ONLY

DESIGN CLASS FUNCTION

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

USER MANUAL Wok Range

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Operator: Save these instructions for future use!

Gas Countertop Griddle

Standard Gas Countertop Griddle

36H SERIES Combination Gas Valve

INSTALLATION, OPERATION, SERVICE & PARTS MANUAL FOR STOCK POT RANGE MODELS VSP100, VSP200 & VSP300

Installation Instructions

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

WARNING: FOR OUTDOOR USE ONLY

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

OWNERS MANUAL INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

FPLP CONVERSION KIT- Small Tank Fire Pit LP Conversion Kit for Manual Ignition Pits

Operator Manual Gas Griddle / Cheesemelter

Gas Countertop Hot Plates

G96 Series BASOTROL Dual Operator Valve

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL. Gas Salamander

JACKSON GRILLS PATIO FIRE

FPLP CONVERSION KIT- Small Tank Fire Pit LP Conversion Kit for Manual Ignition Pits

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

DESIGN CLASS FUNCTION

Natural Gas Conversion Kit

ESG35T * * Installation & Operation Manual. For Service, Call (318) Price: $6.00

North American Orifice Metering System

ASSEMBLY & OPERATING INSTRUCTIONS

for Assembly, Operating & Maintenance of Model A2CC Country Club Gas Grill THIS GAS GRILL IS DESIGNED FOR OUTDOOR USE ONLY.

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

GAS FRYER Instruction Manual Model #5099NS

Your safety and the safety of others are very important.

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Propane Conversion Kit Instruction

GAS SUPPLY DESIGN GUIDE

INSTALLATION AND OPERATION INSTRUCTIONS

PGM365 Cooktop. 2-3 Chassis Assembly* 4 Burner Tubes* 5-6 Top Frame Assembly. 7 Wiring and Lights

Installation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

Installation manual for all 24, 30,36 and 48 ranges

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

127 / 460 Air Mixer and all FPSLPK Kits Installation & Operation Instructions

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

TECHNICAL DATA. Q = C v P S

for Assembly, Operating & Maintenance of THIS GAS GRIDDLE IS DESIGNED FOR OUTDOOR USE ONLY.

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

G95 Series BASOTROL Single Operator Valve

Installation Instructions For Natural Gas Conversion

CASUAL FIRESIDE A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR FIRE PIT FOR PROPANE AND *NATURAL GAS

TECHNICAL DATA. than the water inlet pressure to the concentrate

INSTALLATION INSTRUCTIONS 30" (76.2 CM) FREESTANDING GAS RANGE with standard clean oven

LP GAS PRODUCTS HIGH QUALITY GAS PRODUCTS SINCE 1957

Propane Conversion Kit Instruction

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

/2004 US/CA

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

INSTALLATION INSTRUCTIONS 24" (61.0 CM) GAS SINGLE AND DOUBLE BUILT-IN OVEN

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

G92 Series BASOTROL Automatic Pilot Gas Valve

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

INSTALLATION & OPERATION MANUAL RCT RCR. Open Burner, Griddle & Oven Range. Trueheat RCT & RCR IO Manual Page 1 of 20

VACUUM REGULATORS CONTENTS

Owner s Manual for Assembly, Operating & Maintenance of

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

GAS BBQ 4 burner. instructions for. model no: BBQ10

RV and Outdoor Cooking Regulators and Accessories

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Transcription:

Model RT366 Model RT364C Low profile island trim 11" (279) griddle (optional) Porcelain coated cast iron top grates Dual brass burners 36" GAS RANGETOPS Model RT364G Stainless steel exterior finish Large red control knobs Griddle indicator light Pull-out drip tray Model RT362F Model RT364G shown The Wolf 36" (914) gas rangetop is available in natural or LP gas, with your choice of four top configurations. Model numbers indicate the rangetop features; (C) charbroiler, (G) griddle and (F) French top. The model number followed by (-LP) denotes an LP gas model. This appliance is certified by Star-K to meet strict religious regulations in conjunction with specific instructions found on www.star-k.org. If you want to offer a more professional look to your client s kitchen and still use a cooktop, look to the gas rangetops from Wolf. They offer you that commercial look but give you flexibility to use the ovens in other locations in the kitchen. In fact, the Wolf framed ovens would be a beautiful complement to these cooking instruments. Let Wolf, the corporate companion and kitchen soul mate of Sub-Zero, fuel your passion for cooking and kitchen design. WOLF PLANNING GUIDE 2004 (REV 1.0) 1

FEATURES Natural or LP gas models Classic stainless steel exterior finish Fits standard 24" (610) deep cabinets with zero clearance for easy installation Optional infrared charbroiler, infrared griddle or French top configurations Dual brass burners with automatic reignition at all settings, 500 Btu / hr (.1 kwh) simmer to 16,000 Btu / hr (4.7 kwh) high Porcelain coated cast iron top grates Large red control knobs with four position settings and chrome bezels optional black knobs available at no cost Stainless steel drip tray on ball bearing slides Low profile classic stainless steel island trim Certified by Star-K to meet religious regulations CSA certified for US and Canada Two and five year residential warranty exclusions apply, see warranty at the end of this guide O VERALL DIMENSIONS 27 1 /4" (692) OVERALL DEPTH (to knobs) 1 3 /4" (44) COOKING 10 1 /2" (267) 9 1 /2" (241) 20" (508) WITH 10 1 /2" (267) RISER 36" (914) OVERALL WIDTH 2 3 /4" (70) (to knobs) 24" (610) Dimensions may vary by +_ 1/8" (3). WOLF PLANNING GUIDE 2004 (REV 1.0) 2

MODEL OPTIONS Six Burners RT366 SPECIFICATIONS Overall Rangetop Width 36" (914) Four Burners w/ Charbroiler Four Burners w/ Griddle Two Burners w/ French Top RT364C RT364G RT362F Natural gas models listed, for LP gas add (-LP) to the model number. VENTILATION OPTIONS 36" (914) Pro Series Wall Hood 42" (1067) Pro Series Island Hood Refer to the Wolf Pro Series Ventilation section for additional information. A CCESSORIES 10 1 /2" (267) stainless steel riser Stainless steel island trim Overall Rangetop Height (to cooking surface) 10 1 /2" (267) Overall Rangetop Depth 27 1 /4" (692) Surface Burners Top burners with 500 Btu / hr (.1 kwh) simmer to 16,000 Btu / hr (4.7 kwh) high 11" (279) Charbroiler 16,000 Btu / hr (4.7 kwh) 11" (279) Griddle 18,000 Btu / hr (5.3 kwh) 22" (559) French Top 15,000 Btu / hr (4.4 kwh) Electrical Supply Requirements Power Cord Shipping Weight 110/120 V AC, 60 Hz, 15 amp dedicated circuit 6' (1.8 m) power cord with 3-prong grounded plug 190 lbs (86 kg) - 220 lbs (100 kg) Specifications are subject to change without notice. Black control knobs Porcelain cast wok grate Porcelain cast S-grates Hardwood cutting board LP and natural gas conversion kits High altitude conversion kit Contact your Wolf dealer for additional information on accessories. WOLF PLANNING GUIDE 2004 (REV 1.0) 3

COMBUSTIBLE CONSTRUCTION VENTILATION HOOD 6"min (152) TO COMBUSTIBLE MATERIALS 30"min (762) COOKING TO COMBUSTIBLE CONSTRUCTION 36"min (914) 30"(762) TO 36"(914) FOR COOKING CHARBROILER TO BOTTOM OF VENTILATION HOOD COOKING 6"min (152) TO COMBUSTIBLE MATERIALS 13"max (330) CABINET DEPTH 18"min (457) TO COOKING TOP VIEW OF PLATFORM 1/2" (13) BACK WALL 3"(76) E G 8" (203) 36 1 /4" (921) FINISHED ROUGH OPENING WIDTH 3 /4" (19) PLATFORM 8" (203) 14" (356) LOCATE ELECTRICAL AND GAS SUPPLY WITHIN SHADED AREA THROUGH BOTTOM OF PLATFORM 36"max (914) 2 3 /4" (70) 3/4" (19) PLATFORM 24" (610) ISLAND S: 12" (305) MINIMUM CLEARANCE FROM BACK OF RANGE TO COMBUSTIBLE MATERIALS 0" (0) TO NON-COMBUSTIBLE MATERIALS NO SIDE WALL OR REAR WALL ABOVE COOKING PENNINSULA S: NO SIDE WALL ABOVE COOKING Dimensions may vary by +_ 1/8" (3). DIMENSIONS Overall Width of Rangetop 36" (914) Finished Rough Opening Width 36 1 /4" (921) Location of Electrical and Gas Supply Within shaded area See Installation Instructions shipped with unit for detailed specifications. WOLF PLANNING GUIDE 2004 (REV 1.0) 4

NOTES Caution must be used in planning the proper installation of the Wolf gas rangetop to avoid any fires or damage to adjacent cabinetry or kitchen equipment. Please follow the minimum clearances established in the finished rough opening dimensions as shown in the installation illustration. It is recommended that you use a Wolf Pro Series wall or island ventilation hood with the Wolf gas rangetop. Refer to the Pro Series Ventilation section and the Pro Series ventilation charts in the General Applications section for specifics. Wolf gas rangetops are designed to operate on natural gas at 5" (127) WC (water column) pressure or LP gas at 10" (254) WC pressure. The maximum gas supply pressure to the regulator should never exceed 14" (356) WC;.5 psi (3.5 kpa). Wolf recommends the use of a 1/2" (13) I.D. commercial type flex hose; this is the minimum size that may be used. All plumbing to the flex hose MUST be 3/4" (19) minimum I.D. pipe. A separate external gas shut-off valve must be located near the rangetop in an accessible location. The Wolf gas rangetop functions up to 6,000' (1828 m) in altitude without any adjustment. If the installation is above 6,000' (1828 m), contact your Wolf dealer. The Wolf gas rangetop requires a 110 / 120 V electrical supply to operate the electronic ignition system. The 6' (1.8 m) power supply cord provided with the rangetop is equipped with a 3-prong, grounded plug for protection against shock hazard. The service should have its own 15 amp circuit breaker. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. You must follow all National Electrical Code and gas regulations. In addition, be aware of local codes and ordinances when installing your services. Refer to the installation instructions shipped with each Wolf product for detailed specifications. WOLF PLANNING GUIDE 2004 (REV 1.0) 5