On the design and control of complex tunnel ventilation systems applying the HIL tunnel simulator

Similar documents
METRO System Design. Witt&Sohn AG Aug-11

Appendix FRANCE Annecy Tunnel Courier

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow

Application Block Library Fan Control Optimization

Ingersoll Rand. X-Series System Automation

AN INVESTIGATION OF LONGITUDINAL VENTILATION FOR SHORT ROAD TUNNELS WITH HIGH FIRE HRR

VENTILATION OF PROTECTED AREAS IN ROAD TUNNELS

Distributed Control Systems

Every things under control High-Integrity Pressure Protection System (HIPPS)

Appendix FRANCE Lyon Croix-Rousse Tunnel

OPTIMIZING THE LENGTH OF AIR SUPPLY DUCT IN CROSS CONNECTIONS OF GOTTHARD BASE TUNNEL. Rehan Yousaf 1, Oliver Scherer 1

Lane changing and merging under congested conditions in traffic simulation models

Appendix ITALY Valsassina Tunnel near Lecco (Lombardy)

ZIPWAKE DYNAMIC TRIM CONTROL SYSTEM OUTLINE OF OPERATING PRINCIPLES BEHIND THE AUTOMATIC MOTION CONTROL FEATURES

MoPac South: Impact on Cesar Chavez Street and the Downtown Network

LONGITUDINAL AIR VELOCITY CONTROL IN A ROAD TUNNEL DURING A FIRE EVENT

Queue analysis for the toll station of the Öresund fixed link. Pontus Matstoms *

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios

SoundCast Design Intro

Introducing STAMP in Road Tunnel Safety

AUSTRIAN RISK ANALYSIS FOR ROAD TUNNELS Development of a new Method for the Risk Assessment of Road Tunnels

Tunnel Ventilation The Actual State of the Art

VENTILATION DURING TUNNEL CONSTRUCTION INDUSTRY CONSIDERATIONS

VENTILATION AND ESCAPE FACILITIES FOR SHORT CUT-AND- COVER URBAN TUNNELS

NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOUR IN A MODERN TRAFFIC TUNNEL IN CASE OF FIRE INCIDENT

CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

OPTIMISATION OF VENTILATION IN THE CASE OF A FIRE IN ROAD TUNNELS

Evaluation of the ACC Vehicles in Mixed Traffic: Lane Change Effects and Sensitivity Analysis

Traffic circles. February 9, 2009

Press Release. Friction Stir Welding: Grenzebach extends its portfolio

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

UNIVERSITY OF WATERLOO

ENHANCED PARKWAY STUDY: PHASE 2 CONTINUOUS FLOW INTERSECTIONS. Final Report

DYNAMIC LANES FOR AUCKLAND

Journal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1)

Pedestrian Dynamics: Models of Pedestrian Behaviour

SIDRA INTERSECTION 6.1 UPDATE HISTORY

Dieter Krenz, Linde, Germany, Manel Serra, Inprocess, Spain, and. Theron Strange, Simplot Phosphates, USA, discuss dynamic process simulation

2017 Edition GUIDANCE NOTE GN 8 INVERTER DRIVES FOR FANS AND PUMPS GN 8 - INVERTER DRIVES FOR FANS AND PUMPS

RICK FAUSEL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES

Tools for safety management Effectiveness of risk mitigation measures. Bernhard KOHL

Evaluation of the optimum conditions for a local ventilation system in connection with the mine ventilation network

Public Bicycle Sharing Scheme

APPLICATION NOTES DELOMATIC 4, DM-4 GAS

TRANSPORTATION ANALYSIS REPORT US Route 6 Huron, Erie County, Ohio

Truck Climbing Lane Traffic Justification Report

REQUIREMENTS AND HAND-OVER DOCUMENTATION FOR ENERGY-OPTIMAL DEMAND-CONTROLLED VENTILATION

Introduction Roundabouts are an increasingly popular alternative to traffic signals for intersection control in the United States. Roundabouts have a

METHODOLOGY. Signalized Intersection Average Control Delay (sec/veh)

AGENDA. Stakeholder Workshop

Courseware Sample F0

TP Validating a dynamic grid model with tracer gas injection and analysis

Session Objectives. At the end of the session, the participants should: Understand advantages of BFD implementation on S9700

Controlling the prefeeder

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

Gas Accumulation Potential & Leak Detection when Converting to Gas

Operational Comparison of Transit Signal Priority Strategies

THE CANDU 9 DISTRffiUTED CONTROL SYSTEM DESIGN PROCESS

Cascade control. Cascade control. 2. Cascade control - details

SIL explained. Understanding the use of valve actuators in SIL rated safety instrumented systems ACTUATION

Application Note AN-107

A Conceptual Approach for Using the UCF Driving Simulator as a Test Bed for High Risk Locations

Safety, ventilation and climate in rail tunnels

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

Evaluation summary of Pilot trial with Hard Shoulder Running on the Hillerød Motorway

PROBLEMS ON VENTILATION IN COMPLEX CITY TUNNELS

TECHNICAL NOTE THROUGH KERBSIDE LANE UTILISATION AT SIGNALISED INTERSECTIONS

Appendix BELGIUM Brussels Belliard Tunnel

The Future of Hydraulic Control in Water-Systems

TUNNEL SAFETY BY VENTILATION AN ILLUSION?

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

Motorway-to-motorway: a potential technological solution to motorway congestion

High Efficiency SO2 Scrubber Design to Reduce Caustic Consumption

This test shall be carried out on all vehicles equipped with open type traction batteries.

Measuring range Δp (span = 100%) Pa

PREDICTION OF TOTAL PRESSURE CHARACTERISTICS IN THE SETTLING CHAMBER OF A SUPERSONIC BLOWDOWN WIND TUNNEL

Neles ValvGuard VG9000H Rev 2.0. Safety Manual

Evaluating chaff fire pattern algorithms in a simulation environment. JP du Plessis Institute for Maritime Technology South Africa

Designing a Traffic Circle By David Bosworth For MATH 714

Simulating Street-Running LRT Terminus Station Options in Dense Urban Environments Shaumik Pal, Rajat Parashar and Michael Meyer

MODELLING OF FUME EXTRACTORS C. R.

Study by numerical simulations on the breathing effect in a semi-underground highway with beams and a roof above it

New Technologies applied to the design and optimization of tunnel ventilation systems

PREPARED TESTIMONY OF NICK CONNOR. Q. Please state your name, professional position, and business address.

ROSE-HULMAN INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering. Mini-project 3 Tennis ball launcher

ENS-200 Energy saving trainer

Modeling of Hydraulic Hose Paths

Specifications for the CMI 2409 Magnetocardiograph

CFD Modeling of Thermal Manikin Heat Loss in a Comfort Evaluation Benchmark Test

THE TUNNELS IN GUADARRAMA FOR THE HIGH SPEED RAILWAY

Transitional Steps Zone in Steeply Sloping Stepped Spillways

7.0 FREEWAYS CONGESTION HOT SPOT PROBLEM & IMPROVEMENT PROJECT ANALYSIS & DEFINITION

AVI Based Freeway Incident Detection

Training Fees 3,400 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Control Strategies for operation of pitch regulated turbines above cut-out wind speeds

Line Following with RobotC Page 1

CITY OF SAINT JOHN TRAFFIC CALMING POLICY

The RCM Analyst - Beyond RCM

HENDERSON DEVELOPMENT 213, 217, 221, 221 ½, 223 HENDERSON AVENUE and 65 TEMPLETON STREET OTTAWA, ONTARIO TRANSPORTATION OVERVIEW.

Transcription:

On the design and control of complex tunnel ventilation systems applying the HIL tunnel I. R. Riess and P. Altenburger HBI Haerter Ltd Consulting Engineers, Switzerland P. Sahlin Equa Simulation AB, Sweden Abstract For a complex road tunnel network, the ventilation system has been designed, implemented and tested. For design and optimisation of the control system, a one-dimensional numerical model has been used. With growing system complexity and demanding constraints of time and quality, system tests become increasingly important. They have to be performed based on the assumption that it won t work if it hasn t been tested. In order to have sufficient time to perform these tests, the control system has to be tested prior to installation. For this purpose, a numerical simulation model of the tunnel, ventilation system and control system is used. For later tests, the simulated control system is replaced by a Hardware-In-the-Loop (HIL) setup connecting the to the actual Programmable Logic Controller (PLC) and control code that will be installed. 1 INTRODUCTION The ventilation control during normal operation as well as during incidents has become an important issue. During an incident, the ventilation operation is usually fully automatic. Any failure may lead to severe danger to tunnel users. In normal operation, meeting the pollution criteria inside and outside of the tunnel may be a challenging task, as well. Breach of pollution limits may cause severe penalties on the tunnel operator. Road tunnels especially in an urban environment tend to become very complex with several entry and exit portals, portal air extraction and forced recirculation to avoid portal discharge. The traffic flow may vary rapidly from light free-flowing to heavily congested traffic. With penalties being applied for breaches of design conditions from the first day of tunnel operation, detailed tests of the control system prior to the tunnel opening become increasingly important. As the ventilation control system is required to cover all possible scenarios from normal operation, maintenance and incident modes to partial tunnel closures, numerous 1

operational modes and levels have to be taken into account. Tests have to cover all possible transitions between operational modes and levels. They have to be performed based on the assumption that it won t work if it hasn t been tested. Once the ventilation control system is installed, the time required to perform these tests is normally not available. The tunnel usually has to be opened to traffic as soon as possible. Therefore, the control system has to be tested prior to the installation on site. This can be done with the application of a tunnel : a numerical simulation of the tunnel and ventilation system connected to a PLC running the real world control system. Thus, tests on site are minimised as much as possible. The tunnel is opened to traffic and the ventilation operation is on its optimum from day one. VENTILATION SYSTEM The application of a tunnel for the design and commissioning of the ventilation system was tried for the first time on a very complex urban tunnel system. The tunnel consists of two separate tunnels with uni-directional traffic. The main tunnels include several entry exit ramps, so that the tunnel network has altogether eight tunnel portals..1 Design conditions In this project, the design and control of the ventilation system has to meet stringent requirements for normal conditions, such as: the tunnel ventilation system must supply a sufficient amount of fresh air for pollution dilution in order to meet the in-tunnel air quality requirements; the ventilation system must enable operation of the tunnel without air discharge at the portals; the ventilation system and its control must be designed for economy of operation throughout the full range of tunnel traffic conditions. Penalties apply in the occurrence of a breach of these conditions. The key requirements seem to be partly contradicting, such as maximum pollution dilution and economy of operation.. Ventilation concept For tunnel air discharge, a location in the vicinity of the main western tunnel portal was nominated. The ventilation is designed as a longitudinal ventilation system with fresh air entering the tunnel at all tunnel portals. In the main tunnels, the movement of air utilises the piston effect of the traffic and a series of jet fans distributed in the tunnel sections. At the eastern exit portal, the air is extracted from the eastbound tunnel and via a cross-ventilation station introduced into the westbound tunnel. Along the westbound tunnel, it mixes with additional fresh air coming from the entry portal and the two ramps before it is extracted into the main exhaust ventilation station (Figure 1).

Western Air Flow Traffic Direction Ventilation Tunnel Traffic Direction Air Flow Eastern Figure 1 Complex tunnel ventilation system (normal operation) schematic In case of congested traffic, a slightly different concept is used. The vitiated air extracted from the eastbound tunnel is brought via a ventilation tunnel directly towards the main exhaust ventilation station, thus avoiding increased flow velocities in a congested westbound tunnel..3 Operation modes In order to control the ventilation system under all traffic and operating conditions, nine different operation modes have been defined, such as normal condition, one tunnel closed for incoming traffic, maintenance of one of the three ventilation stations under traffic, as well as several incident modes. The change from one operation mode into another mode is done manually by the operator. However, it is not possible to change from each operation mode into any other mode, as some combinations do not appear reasonable, such as eastbound tunnel closed to westbound tunnel closed.. Ventilation modes Each operation mode includes up to eight ventilation modes four modes for fluid traffic and four modes for partially or fully congested traffic. Additional sub-modes have been introduced in order to cater for traffic scenarios with increased fresh air requirement in a particular ramp. However, the number of different ventilation modes is slightly reduced as not all ventilation modes are available under all operation modes. The change from one ventilation mode into another one is automatically triggered by 3

expected power saving comparison of the number of operating jet fans in the main tunnel with the power requirement for a different exhaust flow rate; pollution levels in the main tunnel an elevated pollution level triggers the ventilation system to switch to a mode with increased fresh air supply in the main tunnel; traffic data a combination of reduced average speed with high traffic density triggers the ventilation system to switch to a ventilation mode designed for congested traffic. In order to avoid oscillation between ventilation modes, a minimum delay between ventilation mode changes is defined..5 Summary The ventilation design comprises of 56 jet fans, distributed in thirteen tunnel sections, and ten axial fans, installed in three large ventilation stations. The ventilation control system includes numerous operation modes and ventilation modes. The ventilation control system is fully automatic within each operation mode. 3 DESIGN, CONTROL AND INSTALLATION 3.1 Ventilation design The required exhaust flow rates were calculated from the maximum fresh air requirement which occurs during congested traffic throughout the tunnel. During free flowing traffic, a reduced fresh air supply is sufficient to meet the in-tunnel air quality requirements. The required number and location of jet fans was calculated using a one-dimensional steady state network model. The number of jet fans required to operate in each tunnel section was determined for predicted traffic scenarios as well as tunnel capacity. Some scenarios assumed selected sections of the tunnel being closed for incoming traffic. These scenarios may require additional jet fan operation for maintaining air intake at all tunnel portals. This trusted inhouse model was subsequently used to validate the dynamic model. 3. Ventilation control system design The ventilation control system includes the operation modes described in Section.3 and the ventilation modes given in Section.. The control logic within a ventilation mode consists of fixed exhaust flow rates for the three ventilation stations; six independent control loops for the operation of the jet fans in the tunnel sections, either controlling the air flow to a given set-point or balancing the air flow in two adjacent tunnel sections (Figure ).

EB6 A EB EB1 EB3 B C EB EB5 BVS EVS WB6 D CVS WB5 WB WB3 WB WB1 F E WB7 Figure Control loop schematic As each control loop is governed by two parameters, numerous parameters had to be analysed and tested during design and optimisation of the control system. This was done by utilising the IDA Road Tunnel Ventilation software (IDA RTV) (1) that provides a one-dimensional network model of the tunnel network, the ventilation system, the control system, the dynamic traffic flow, including vehicle emissions as well as pollution and air flow monitors. Figure 3 shows the schematic representation of the tunnel in IDA RTV during the detailed design stage, containing the aerodynamic model of the tunnel as well as the control components. The eastbound tunnel is above, the westbound below. For both tunnels, traffic direction is from left to right. The model has a total of,5 variables, 15 of which belong to the control system. A typical simulation experiment covering 1 hours of system operation takes about 3 seconds of execution time. A total of 15 time-steps have then been taken, ranging in size between.36 and 36 seconds. The variable time step differential-algebraic equation solver adapts automatically the step-size to the frequency content of the solution according to a tolerance parameter. Discrete events in driving functions and discontinuities in system equations are treated by special methods. 5

MiniboostEB Speed_Mainline ModeChange MiniBoostWB Speed_SideExit Gain k-1 Gain k-1 FirstOrder1 T1 FirstOrder T1 Gain6 k-1 NSWIT CH5 NSWITCH6 NSWITCH1 Abs1 NSWITCH Abs Product1 Abs Product Product NSWIT CH3 Gain1 k-1 NSWITCH13 Gain5 k-1 FirstOrder1 T1 FirstOrder13 T1 NSWITCH1 NSWIT CH7 Abs6 Gain7 k-1 Product6 Abs11 FirstOrder1 T1 Gain3 k-1 Product18 NSWITCH8 FirstOrder5 Abs1 T1 Product17 NSWIT CH FirstOrder1 T1 Abs NSWITCH9 Product Abs1 Product19 1 11 1 13 1 1 3 3 1 5 P ortal 18 17 16 15 6 7 8 9 7 8 9 3 31 P ortal 19 5 6 1th Int. Symp. Aerodynamics and Ventilation of Vehicle Tunnels, Portoroz 6 Project: rtv_fire Description: With separate Jet Fans and separate Axial Fans Vehicles Ambient Global Res ults Add path report Simulation data... Fan power consumption Volume-Flow[m3/s] RTV Invoke Power-Consumtion[kW] Air-Speed_EB Start simulation Air-Speed_WB CO Concentration WB[ppm] fixed fans ventilation station vsd fans 1 Traffic vsd fans input time series fixed fans 3 fixed fans tunnel sections control objects 5 fixed fans Figure 3 The detailed design system model 3.3 The HIL tunnel The electro-mechanical installations usually form the last part of the tunnel construction. The time schedule is very tight as the tunnel should be opened to traffic at the earliest possible date. Especially in a toll-financed project, any delay to the tunnel opening causes additional costs as well as loss of revenue. Once the control system principles have been developed and control loops tuned in the simulation model, the code of the target PLC system can be written. This encompasses not only the ventilation related part of the control system but also a large number of other disciplines such as lighting, traffic management, CCTV surveillance etc. As with any computer programme, there will initially be a number of bugs. In addition to this, the real PLC implementation has to deal with several practical aspects of fan and damper operation, that are not worthwhile to model in the off-line control system model, such as component failure signals, position feedback loops etc. All in all, the correspondence between the conceptual control model and the real implementation cannot be taken for granted. At this stage, a HIL tunnel helps debugging and optimising the control system code. The full control code is loaded on the actual (hardware) PLC to be used in the tunnel. The feedback from the tunnel is simulated by the existing dynamic model. The simulation creates all relevant signals (CO, velocity, visibility, traffic density and traffic speed) that normally would be provided by physical sensors in the tunnel. Through an interface, simulated sensor signals are transferred to the PLC. According to these inputs, the PLC will determine fan and 6

MiniboostEB Speed_Mainline ModeChange MiniBoostWB Speed_SideExit Gain1 Gain FirstOrder19 FirstOrder Firs tor der 1 FirstOrder3 FirstOrder FirstOrder FirstOrder FirstOrder1 FirstOrder Firs tor der 7 Gain5 Gain18 Gain19 FirstOrder1 FirstOrder FirstOrder8 Gain3 FirstOrder FirstOrder3 Gain7 Gain FirstOrder3 FirstOrder7 FirstOrder5 FirstOrder6 FirstOrder8 Gain6 Gain8 FirstOrder8 FirstOrder9 FirstOrder3 FirstOrder31 FirstOrder9 FirstOrder5 FirstOrder6 FirstOrder7 FirstOrder53 FirstOrder1 FirstOrder11 FirstOrder1 FirstOrder13 FirstOrder3 FirstOrder33 FirstOrder3 FirstOrder35 FirstOrder6 Gain FirstOrder FirstOrder5 FirstOrder36 FirstOrder37 FirstOrder38 FirstOrder5 FirstOrder5 FirstOrder1 FirstOrder15 FirstOrder16 FirstOrder51 FirstOrder39 FirstOrder FirstOrder17 FirstOrder18 1 11 13 1 17 1 3 Gain1 Gain13 Gain1 3 1 5 8 Gain9 Gain1 Gain11 Gain15 Gain16 Gain17 Gain P ortal 18 16 15 7 6 8 9 7 9 3 31 3 P ortal 19 5 FirstOrder9 6 1th Int. Symp. Aerodynamics and Ventilation of Vehicle Tunnels, Portoroz 6 damper operation. These requests are transferred back to the real time simulation the loop is closed. Project: Description: Control-System in Model Gespeichert 1.3.5 18:35 Vehicles Ambient Global Res ults Add path report Simulation data... Fan power consumption Air-Speed_EB RTV Invoke Air-Speed_WB CO-Concentration_WB[ppm] Start simulation CO-Concentration_EB[ppm] Volume Flow AxialFans Av eragewb NIL + fixed fans NIL Traffic1 Traffic vsd fans SS3-to-EB 1 Traffic SS1-to-EB vsd fans SS-to-EB fixed fans SS-to-EB interface objects 3 SS-to-WB fixed fans SS1-to-WB SS3-to-WB interface objects fixed fans 5 Figure The system model for the HIL simulation The architecture of the tunnel, interfaces and PLC control unit is shown in Figure 5. The full system includes the control code development environment, which is installed on a separate PC and the tunnel-operator interface (HMI) same as in the physical control room. The tunnel control system may be operated either using the control code development environment or the operator interface. However, the final HMI might not be available at an early stage of the control system tests. The tunnel represents the physical reaction of the real tunnel, giving air flow signals and pollutions measurements according to the traffic scenario and the operation of the ventilation system. Time series of air flow, pollution and other signals as well as data on ventilation operation may be stored in the developer environment as well as in the tunnel. Figure shows the corresponding tunnel system model. In comparison to the model of Figure 3, control components have been replaced by real-time import and export objects, which govern data exchange with the physical PLC. 7

Tunnel HIL Simulator Windows PC Windows PC Windows PC IDA Road Tunnel Ventilation Software PLC Control Unit Control Software Developer Enviroment Human Machine Interface HMI Interface OPC Client Ethernet Figure 5 Tunnel HIL schematic The additional effort required for the HIL tunnel lies in the development of the HIL interface between the dynamic software model of the tunnel and the PLC. Often, the implementation of this interface can be based on the Open Process Control (OPC) standard, thereby reducing the need for manufacturer dependent coding. A few changes to the software model of the tunnel are also required, e.g. to convert units of simulated signals to those of the PLC implementation and to artificially provide feedback signals that are not covered by the virtual tunnel model. The HIL interface of IDA manages the timestep of the numerical model and alarms if for instance the simulation model lags too far behind physical time. The numerical model sometimes has to negotiate system discontinuities using elaborate and timeconsuming methods, so that exceptions may occur even if the average progress of the simulation model is considerably faster than real time. 8

8 Simulation 8 Tunnel Measurement 7 7 Ventilation Mode 6 5 3 1 Ventilation Mode 6 5 3 1 1 15 16 17 18 19 1 15 16 17 18 19 8 8 EB3 Number of Jet Fans 6 - Number of Jet Fans 6 - EB6 - - 1 15 16 17 18 19 1 15 16 17 18 19 Air Speed [m/s] 5 3 1-1 Air Speed [m/s] 5 3 1-1 EB3 EB6. - - -3-3 1 15 16 17 18 19 1 15 16 17 18 19 Figure 6 Comparison HIL tunnel vs. measurements Dynamic testing of the control code can either be done in the office or on site. It makes sense to continue testing on site as soon as the equipment in the tunnel is available. Discrepancies between the desired operation and the simulation results can be communicated to the control system supplier. Alterations can be agreed and implemented. 3. Commissioning Due to extensive testing of the control system prior to installation, only a minimum time is required for commissioning tests on site. The features that remain to be tested on site include 9

the air quality and air flow monitors as well as communication between the control system and the ventilation equipment, such as jet fan selection from a particular group. Only minor adjustments to the control parameters are required on site, depending on the accuracy of the aerodynamic model (Figure 6). In this particular project, it would not have been possible to debug the control code, optimise the system parameters and run all required tests within the time frame available between the installation in the tunnel and the tunnel opening. It is expected that in any project of similar complexity, a HIL tunnel would be the only measure to finalise the control system in time. TIME SCHEDULE Testing the ventilation control system is a rather slow process as the control parameters have to be tested in real time simulations. The time scales of a typical tunnel ventilation system range from 1 to 3 minutes. Each test scenario runs for eight to twelve hours, so several transitions from one ventilation mode to another may be tested. Simulator tests may run at night-time in order to allow a comprehensive analysis of recorded data during the day. The required amount of testing, of course, depends on the quality of the control code as well as the pre-selection of control parameters. Usually, control parameters are adapted rather easily, but for changes to the code, the control system supplier has to be involved. Table 1 gives a possible time schedule for the project. The control code has to be available at least four months prior to tunnel opening. The interface between the control system and the has to be defined six months prior to tunnel opening. It is preferable for the tests if a basic HMI is available at an early stage of the control code tests. Table 1 Time schedule Time from Action tunnel opening - 6 months decision whether or not the tunnel should be applied for HIL tests of the control system code - months tunnel set up for communication with PLC and HMI (if available) begin of tests on control code - months control code debugged and optimised begin installation of control system hardware in the tunnel -1 month begin of tests on the ventilation system in the tunnel (optional: fine tuning of the tunnel according to aerodynamic measurements in the tunnel) commissioning tests - 1 week end of tests on the ventilation system + tunnel opening + 1 to weeks fine tuning of control parameters according to actual traffic in the tunnel 1

One drawback of the tunnel application is the shifted time schedule of project delivery. Especially the time schedule of the control system supplier has to be shifted in a way that allows for completion of the control code prior to testing. In the time schedule of a conventional project, the control code has to be finalised only a short time before the installation of the hardware in the tunnel. Thus, a decision about the application of the tunnel made only six months before tunnel opening might already be too late for the control system supplier. 5 CONCLUSIONS The ventilation control system of a complex tunnel network has been tested prior to installation in the tunnel. Any reduction of tests and optimisations in the completed tunnel allow an earlier project completion. Once the tunnel is open to traffic, there is only minor fine-tuning required without interference to normal operation. The risk of breach of technical requirements such as continuous portal air inflow or maintaining in-tunnel air quality is greatly reduced. The control system is operating in an optimised way from day one of the tunnel operation. The decision about whether or not a HIL test of control code should be carried out should be made as early as possible in the project. As the tunnel represents an additional investment, the costs have to be weighed against potential savings and reduced technical risks during commissioning. The benefits of the clearly increase with the complexity of the ventilation system and the ventilation control system. At a later stage, the may be used as a training tool for the tunnel operator by running a separate, but identical ventilation control system (either in a PLC or on a computer) connected to the tunnel. REFERENCES (1) IDA Road Tunnel Ventilation, EQUA Simulation AB 11