Manual Tissue Microarrayer

Similar documents
TMArrayer Users Guide

Tissue-Plus. User Manual. O.C.T. Compound. Optimal Cutting Temperature Embedding Medium for Frozen Tissue Specimens

Pipetting Small Volumes

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Ultrasound Guided Thoracentesis Simulator Strap-on Type

Ultrasound Guided Thoracentesis Simulator Strap-on Type

BPS-2, Rev TABLE OF CONTENTS

OXYTEMP Instructions 1

Corning Microarray Hybridization Chambers

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

UPPER ARM INTRA-MUSCULAR INJECTION SIMULATION KIT USER MANUAL

PreAnalytiX Supplementary Protocol

QUIK-jet Micro-Injection System

Unblocking the MicroSprayer Aerosolizer Model IA-1C With the High Pressure Reverse Cleaning Adapter. Instructions for Use

DIAGNOSTIC CARDIOLOGY

Ultrasound Guided Thoracentesis Simulator

Basic Flows in a Microfluidic Device

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

CVC Insertion Simulator

User manual STARLOCK. Careways International - Innovation Quality Performance

RECOMBINATE. [Antihemophilic Factor (Recombinant)] (For intravenous use only)

Gel Loading Practice MiniLab

Fisherbrand. Finnpipette INSTRUCTIONS FOR USE PARK LANE Pittsburgh PA

Shandon Cryotome Cryostat Series

Bio SB BIOSCIENCE FOR THE WORLD

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Connecting a SSL/PTV Backflush System

Unisense In Situ UniAmp Connector System

Safety Huber Needles

INSTRUCTION MANUAL. January 23, 2003, Revision 0

BACTRON Anaerobic Chambers The Complete Environmental Microbiology Workstation Anaerobic, Hypoxic, & other Gas Environments

INFUSION SYSTEM (110V) (220V) USER S MANUAL

Solvent System Walkthrough

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Version BA D

Agilent 1220 Infinity II LC Mobile Upgrade Kit

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

USER'S GUIDE. Nanoflow Probe. Red Stripe. 3-4mm. ptfe Sleeve. To Injector. ZU1XC Fused Silica TTF115. Fused Silica. ptfe Sleeve

Unblocking the MicroSprayer Aerosolizer Model IA-1B With the High Pressure Reverse Cleaning Adapter. Instructions for Use

PoolLock Easy Pool Cover

Pipetting and Determining Protein Concentration

BAUSCH & LOMB ENGINEERING ROCHESTER. Title: Membrane Press Procedure Page 1 of 14

Best Practices for Infinium Assays

Patients Guide for Self Administering Intravenous Antibiotics General points

Model 405 &407 Small Animal Ventilator. User Manual v3.5

Tridak Model 1050 User Guide

Before you start sampling, be sure to read

ADVANCED CORE DECOMPRESSION SYSTEM X-REAM. Percutaneous Expandable Reamer PRO-DENSE. Core Decompression Procedure Kit SURGICAL TECHNIQUE

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Figure. Experimental set up of catalyst, reactants and product syringes.

REV: 03/17. User Manual

Standard. Abdominal Aortic Aneurysm (AAA) Repair Trainer. Part No: 60610

Introduction to Ecoseal

ADVANCED CORE DECOMPRESSION SYSTEM X-REAM

Boyle s Law VC 09. Experiment 9: Gas Laws. Abstract

MAINTENANCE PROCEDURE FOR X 650

product manual H-1200 & H-1250 Universal and Portable Penetrometers

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

OPERATING INSTRUCTIONS. Parts List N. Note: Owner and operator MUST read and understand this operating instructions before use this lift table.

instruction manual tintoretriever pressure cooker

Histology Protocols. Safety and Good Laboratory Practice (GLP)

Hydraulic Punch Drivers

Fruit Testing during Long Term Storage

Zero Head Space Extractor. Catalogue No. YT HW. Operation and Maintenance Manual

Rev. B Sept 06. VD510 INSTRUCTION MANUAL Part # DISPENSING VALVE MODEL VD510 INSTRUCTION MANUAL

Experiment 18 Properties of Gases

F776 IM_v4_ F776 INSTRUCTIONS. Liberty Security Gate Kit. With Stay-Open Feature & Additional 9cm Extension

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

EVO Solid Downtube. Operators Manual for Downtubes fitted with zinc plated springs June 2004

Ultra Concentrate Dispensing System

Bio SB BIOSCIENCE FOR THE WORLD

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

Elcometer 138. Bresle Kit and Patches. Operating Instructions

TURBO SET 1000 E D $'9 5(9

PyroShot High Speed (HS) Including Long Range and BackFire options Serial Numbers HS-301 and above

INSTRUCTIONS FOR USE - US RaplixaSpray (Raplixa Delivery Device)

Liquidator 96 Manual benchtop pipetting system

Rev. A Jul 07 Part # SS VD510-SS INSTRUCTION MANUAL DISPENSING VALVE MODEL VD510-SS INSTRUCTION MANUAL

Port - Body in a Box User s Manual

USER GUIDE ROLLING WALKERS INSTRUCTIONS FOR USE JANUARY, Maximum User Weight: 170kg (Do not exceed this weight)

Internal Sealing of Masts

Bio-sample testing on an adaptation to a tensile testing machine

Series Environmental Chambers

[USING THE VITROBOT April 9, Using the Vitrobot

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

MSD 96-Well MULTI-ARRAY CRP Assay

User s Manual. Autoclavable & UV r e s i s t a n t. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

SAILTEC, INC CONGER COURT, OSHKOSH, WI USA

RST INSTRUMENTS LTD.

Operating Instructions. Rainin Classic Manual Pipette

200 / 300 Upgrade Kits

Deep groove ball bearings L12DDU. Polyolefin is used for packaging food in supermarkets, replacing dioxin-generating vinyl chloride.

Abdominal Aortic Aneurysm (AAA) Repair Trainer User Guide

Quick Reference Guide

Info Counting chamber (haemacytometer)

Operating instruction for the quick-change tap holders type:

Standard. Bag & Stand Advanced Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00442

Transcription:

User Guide Manual Tissue Microarrayer Quick Ray

NOTE This user guide describes the instruction of Quick-Ray. Review this user guide to avoid injury and prevent damage to this product or any products connected to it before you use Quick-Ray. To avoid potential hazards, use this product only as specified in this guide. QuickRay is registered trademarks of Unitma Co., Ltd. Contacting us : UNITMA Co., Ltd. 3F, Chungmyeong B/D, 224-8, Jamsil-Dong, Songpa-Ku, Seoul, 138-220, Korea Tel: +82-2-420-0070 Fax: +82-2-420-9797 http://www.unitma.com E-mail: unitma@unitma.com Tissue Microarray? Tissue Microarray (TMA) is a technique that enables the tissues from many patients to be arrayed in a single slide. You can compare and analyze the expression of various genes and protein from the tissues. This technique has an advantage because you can analyze the tissues in the same condition to enhance the efficiency of the research. TMA technique reduces the use of reagent, time and human resources tremendously. Beside increasing throughput, it offers the following benefits ; conservation of tissue resources, improved internal experimental control, reduced consumption of reagents and facilitation of multicenter research studies. TMA also can be applied to almost every tissue processing including immunohistochemistry, in situ hybridization, FISH and in situ PCR.

Quick-Ray, Manual Tissue Microarrayer Minimized size arrayer comparing with the conventional products Portable, easy to carry and to make the array block anytime and anywhere Easy to handle. Inexperienced pathologist can handle easily in the lab. Simple developing procedure Easy to create the various sized block with using disposable bases Steel array block and cassette array block are available Low cost to purchase Quick Ray SET Quick Ray Tip Quick Ray Base Mold Guide for 1mm recipient block Weight : 140g Length : 15.5Cm Tip & Recipient block core size 1mm 2mm 3mm 5mm 1.5mm(Tip available only for the recipient block constructed with Quick Ray Mold Recipient block

CONSUMABLES Premade recipient blocks Constructed recipient blocks 5mm x 20 well 3mm x 30 well 2mm x 60 well 1mm x 120well Quick-Ray Mold Kit Core size : 1mm 170 holes (10 x 17) Core size : 1.5mm 150 holes (10 x 15) Core size : 2mm 70 holes (7 x 10) Core size : 3mm 40 holes (5 x 8)

PROCEDURE How to construct a recipient block with Quick Ray Mold Kit 1. Place the Quick Ray Mold kit in a dry oven for 30 minutes at 70~80 C to warm-up the mold kit. * Note : This is strongly recommendable for lengthening durability of the mold kit as well as good quality recipient block. 2. Dispense liquid paraffin (60~65 C) slowly into the mold kit until the top of core rods are fully submerged. A. Paraffin dispense should be done so slowly that no bubbles are to be formulated among the core rods. B. When some bubbles are formulated, remove them with heated forceps. 3. Place an embedding cassette on the mold kit 4. Dispense enough liquid paraffin into the embedding cassette

5. Solidify the embedding cassette and the mold kit at a normal room temperature or at about 4 C for 30~60 minutes. If solidified at lower temperature, the block may have cracks in it. 6. Separate the mold kit from the embedding cassette slowly and carefully. 7. Trim paraffin around the periphery of the recipient block. (Pic. Fully completed recipient blocks) How to array the sample tissues into the recipient block by using Quick Ray 1.Place the reference slide and the donor block on microscope stage for position marking with an oil pen. 2. Extract the marked tissue from the donor block by using the Quick Ray needle 1) Place the donor block on a horizontal and flat table. 2) Hold the Quick-Ray in your hand and tighten your grip. 3) Hold the Quick-Ray needle perpendicular to the marked position of the donor block. 4) Insert the Quick-Ray needle into the donor block at the proper depth of 5mm slowly. (Don t insert it quickly and too deep to prevent to damage the donor block and the Quick Ray needle.)

* Quick Ray needle s depth: 5mm * Incubate the easily breaking donor block in a heating oven or a chamber at 37~40 for 15 ~ 20 minutes. 3. Deliver the extracted tissue into the corresponding holes of the recipient block that were pre-made by UNITMA, with Quick Ray needle. 1) Place the recipient block on a horizontal and flat table. 2) Hold the Quick-Ray needle with the extracted tissue perpendicular to the corresponding holes of the recipient block. 3) Inject the extracted tissue (core) into the corresponding holes of the recipient block at the proper depth of 4mm by pushing the Quick Ray plunger slowly. 4) Gently push or tap in all tissue cores to ensure evenness for microtomy. 4. Put the recipient block into embedding mold with cutting section faced down and incubate it in oven at 60 for 30 minutes.(the top side of the recipient block in Step 3 will be cutting section.) 5. Take out the recipient block when completely transparent. Embedding 6. Solidify the block in cold plate. 7. Cutting (about 4 μm) Step 1 for Embedding Step 2 for Embedding Step3 for Embedding

How to use the Guide for 1mm recipient block 1. Put the recipient block into the prop hole at bottom side. 2. Fit the 1mm guide on the prop. 3. Extract the marked tissue from the donor block by using Quick-Ray needle. 4. With fixing the prop by hand, insert the Quick-Ray needle into the guide hole, and put the extracted tissue into the recipient block hole by pushing the knob down. 5. Remove the guide and recipient block from the prop. Note : A. In case of using 2, 3 and 5mm recipient block, insert the extracted tissue directly into the recipient block without the guide by pushing the Quick-Ray knob down. B. The guide cannot be used for recipient blocks produced with Quick Ray Mold kit due to the size and embedding cassette.

BLOCK & SLIDE

ORDER Product Cat. No. Standard Pack Quick Ray Set Full set with 4 Tips and 4 sized blocks UT06 1 set Single set for 1 mm puncher with a guide UT06T1 1 set Single set for 2mm puncher UT06T2 1 set Single set for 3mm puncher UT06T3 1 set Single set for 5mm puncher UT06T5 1 set Single set for 1.5mm puncher (*Ref) UT06T1.5 1 set Tip 1mm UT06-1 1 ea 1.5mm UT06-1.5 1 ea 2mm UT06-2 1 ea 3mm UT06-3 1 ea 5mm UT06-5 1 ea Guide for 1mm recipient block UG06 1 set Premade recipient block 1mm (10 x 12 ; 120 wells) UB06-1 1 ea 2mm (6 x 10 ; 60 wells) UB06-2 1 ea 3mm (5 x 6 ; 30 wells) UB06-3 1 ea 5mm (4 x 5 ; 20 wells) UB06-5 1 ea Quick Ray Mold Kit 1mm (10 x 17 ; 170 wells) UM01-1 1 ea 1.5mm (10 x 15 ; 150 wells) UM01-1.5 1 ea 2mm (7x 10 ; 70 wells) UM01-2 1 ea 3mm (5 x 8 ; 40 wells) UB01-3 1 ea Base mold UBM06 1 ea Embedding cassette UC06 500/PK * Ref : Manual single set of 1.5mm puncher (UT06T1.5) does not include a sample recipient block because premade recipient block of 1.5mm size is not available. 1.5mm recipient block can be produced only with Quick Ray Mold Kit (UM01-1.5)