Correction of Pressure Drop in Steam and Water System in Performance Test of Boiler

Similar documents
Laboratory studies of water column separation

Experiment 8: Minor Losses

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

The Discussion of this exercise covers the following points:

Two-stage pulse tube refrigerator with step displacer as phase shifter

Third measurement MEASUREMENT OF PRESSURE

Integral type Differential pressure flowmeter VNT Series

The water supply for a hydroelectric plant is a reservoir with a large surface area. An outlet pipe takes the water to a turbine.

RESEARCH OF BLOCKAGE SEGMENT DETECTION IN WATER SUPPLY PIPELINE BASED ON FLUID TRANSIENT ANALYSIS ABSTRACT

The Relationship between the Depth Embedded Pipe Pile and the Force of Clamping Jaw

THERMODYNAMICS, HEAT AND MASS TRANSFER TUTORIAL NO: 1 (SPECIFIC VOLUME, PRESSURE AND TEMPERATURE)

Journal of Chemical and Pharmaceutical Research, 2014, 6(3): Research Article

ASSIGNMENT 2 CHE 3473

Heat Pump Connections and Interior Piping

ASSIGNMENT 2 CHE 3473

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

CFD Analysis of the Anti-Surge Effects by Water Hammering

Concept of modernization of input device of oil and gas separator

Self-operated Pressure Regulators for special applications

Heat Transfer Research on a Special Cryogenic Heat Exchanger-a Neutron Moderator Cell (NMC)

The Mechanism Study of Vortex Tools Drainage Gas Recovery of Gas Well

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

EXAM # 2. First Name Last Name CIRCLE YOUR LECTURE BELOW: INSTRUCTIONS

Application Worksheet

PHYS 101 Previous Exam Problems

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

ADVANCES in NATURAL and APPLIED SCIENCES

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Experimental study for flow characteristics and performance evaluation of butterfly valves

EDEXCEL NATIONALS UNIT 6 MECHANICAL PRINCIPLES and APPLICATIONS. ASSIGNMENT No. 4

Coriolis Mass Flow Meter

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

InstrumentationTools.com

Chapter 9 Fluids and Buoyant Force

Unit A-2: List of Subjects

Numerical Investigation of Air Bubbles Evolution and Coalescence from Submerged Orifices Based on OpenFOAM

RESIDENTIAL WATER DISTRIBUTION

WATER HYDRAULIC HIGH SPEED SOLENOID VALVE AND ITS APPLICATION

1. The principle of fluid pressure that is used in hydraulic brakes or lifts is that:

H16 Losses in Piping Systems

SPH 4C Unit 4 Hydraulics and Pneumatic Systems

Analysis and Research of Mooring System. Jiahui Fan*

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

Stress Analysis of The West -East gas pipeline with Defects Under Thermal Load

1. All fluids are: A. gases B. liquids C. gases or liquids D. non-metallic E. transparent ans: C

(Refer Slide Time: 2:16)

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

ENGG. THERMODYNAMICS

2014. Multistage throttling characteristics of reverse direction impact of pilot operated check valve

Liquid level measurement using hydrostatic pressure and buoyancy

Enter your parameter set number (1-27)


The Discussion of this exercise covers the following points: Range with an elevated or suppressed zero Suppressed-zero range Elevated-zero range

ENGINEERING FLUID MECHANICS

Physical explosion analysis in heat exchanger network design

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

Static Fluids. **All simulations and videos required for this package can be found on my website, here:

A Numerical Simulation of Fluid-Structure Interaction for Refrigerator Compressors Suction and Exhaust System Performance Analysis

Physics 11 Unit III Practice Test Projectile Motion. Instructions: Pick the best answer available in Part A and Show all your work for Part B

****** * EX * ****** DWN W.W.POWELL CALCULATION OF FLOW LOSSES IN INLET CHK D.PAPA AND DISCHARGE HEADERS ASSOCIATED WITH

LESSON 3.2 Understanding pressure in liquids

Quiz name: Chapter 13 Test Review - Fluids

and its weight (in newtons) when located on a planet with an acceleration of gravity equal to 4.0 ft/s 2.

THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

Mass Flow Controller (MFC) for Gases

! =! [4 (2) ! n] 16 th Australasian Fluid Mechanics Conference Crown Plaza, Gold Coast, Australia 2-7 December 2007

3 1 PRESSURE. This is illustrated in Fig. 3 3.

Tutorial. BOSfluids. Relief valve

Micro Motion Pressure Drop Testing

KNOWN: Mass, pressure, temperature, and specific volume of water vapor.

Operating instructions Pitot Static Tube

Analysis of pressure losses in the diffuser of a control valve

ENGR 292 Fluids and Thermodynamics

Chapter 13 Fluids. Copyright 2009 Pearson Education, Inc.

Gerald D. Anderson. Education Technical Specialist

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate

Numerical Simulation of the Basketball Flight Trajectory based on FLUENT Fluid Solid Coupling Mechanics Yanhong Pan

for Stainless Steel Lines of Pressure Vessels, Hot Water Boilers, Heat Exchangers, Secondary Side of Pressure Reducing Valves etc.

KC Series Gas Components and Supply Design Guide

Study on Water Hammer Prevention in Pumping Water Supply Systems by Multi-valves

AIR PRESSURE CONTROLLED MASS MEASUREMENT SYSTEM

ROSE-HULMAN INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering. Mini-project 3 Tennis ball launcher

Mass Flow Controller (MFC) for Gases

Effect of attack angle on flow characteristic of centrifugal fan

Mass Split of Two-Phase-Flow

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

1.2 Example 1: A simple hydraulic system

Transient Analyses In Relief Systems

Seated valve for steam (PN 25)

Use equation for the cylindrical section and equation or for the ends.

TUTORIAL. NPSHA for those who hate that stuffy word. by Jacques Chaurette p. eng. copyright 2006

1. Air is blown through a pipe AB at a rate of 15 litre per minute. The cross-sectional area of broad

Modelling of the Separated Geothermal Water Flow between Te Mihi flash plants

Transcription:

IOP Conference Series: Earth and Environmental Science PAPER OPEN ACCESS Correction of Pressure Drop in Steam and Water System in Performance Test of Boiler To cite this article: Jinglong Liu et al 2018 IOP Conf. Ser.: Earth Environ. Sci. 108 052113 View the article online for updates and enhancements. This content was downloaded from IP address 148.251.232.83 on 12/10/2018 at 21:23

Correction of Pressure Drop in Steam and Water System in Performance Test of Boiler Jinglong Liu 1, Xianqiao Zhao 1, Fanjun Hou 2, Xiaowu Wu 2, Feng Wang 3, Zhihong Hu 1, Xinsen Yang 1 1 State Grid Shandong Electric Power Research Institute, Jinan 250000, China 2 Shandong Zhongshi Yitong Group, Jinan 250000, China 3 Shenhua Guohua Shouguang Power Generation, Shouguang 262700, China *Corresponding author e-mail: 470901183@qq.com Abstract. Steam and water pressure drop is one of the most important characteristics in the boiler performance test. As the measuring points are not in the guaranteed position and the test condition fluctuation exsits, the pressure drop test of steam and water system has the deviation of measuring point position and the deviation of test running parameter. In order to get accurate pressure drop of steam and water system, the corresponding correction should be carried out. This paper introduces the correction method of steam and water pressure drop in boiler performance test. 1. Introduction The steam and water pressure drop of boiler is an important evaluation index of boiler performance test. It mainly refers to the pressure drop in the superheated, reheater and economizer of boiler and it is a fine project in the contract of the boiler. Fines are generally measured with 0.01Mpa as the smallest unit of measurement. Therefore, the accurate measurement of steam and water pressure drop is very important. Due to the limitation of installation condition, the measuring points are generally not installed in the guaranteed position and the measuring device and the measured points are not on the same horizontal plane. At the same time, as the fluctuation of working condition, there exists deviation between the test and design conditions of boiler maximum continue rate (BMCR) in boiler performance test [1]. If the boiler output is greater than the design value of BMCR, the pressure drop of steam and water system will increase; conversely, it will decrease. Therefore, in order to obtain accurate steam and water pressure drop, it is necessary to correct the measured values. 2. Steam and Water Pressure Drop The steam and water pressure drop refers to the pressure drop caused by the flow resistance and the gravity pressure difference while the steam and water flow in the boiler and it s calculated by the inlet and outlet static pressure difference. At present, the main content of assessment of the steam and water pressure drop is total pressure drop from the economizer inlet to the superheater outlet and total pressure drop of heat exchanger. Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd 1

=steam and water pressure drop, MPa =inlet static pressure, MPa =outlet static pressure drop, MPa (1) To IP cylinder To HP cylinder 8 4 5 7 9 3 6 1 From HP heater 2 From HP cylinder 1Economizer 2Furnace 3Low Temperature Superheater 4Platen Superheater 5Final Superheater 6Low Temperature Reheater 7High Temperature Reheater 8Separator 9Storage Tank Figure 1. Side view of boiler steam and water circuit. The total pressure drop of single phase fluid flow is [2] (2) =total pressure drop, MPa =frictional pressure drop, MPa = local pressure drop, MPa =gravity drop, MPa =acceleration pressure drop, MPa To steady flow, if the pipe diameter is constant, the friction pressure drop is expressed as follows (3) 2

= the integral average specific volume along the length of the fluid, m 3 /kg = mass velocity of the working medium, kg/ (m 2 s) To single phase fluid, the local pressure drop is expressed as follows (4) = local resistance coefficient To single phase fluid, the gravity drop is expressed as follows (5) (6) =average density of inlet and outlet working medium in the pipe, kg/m 3 = height difference between inlet and outlet of the pipe, m, = inlet and outlet height of the pipe, m The acceleration pressure drop is expressed as follows (7), =specific volume of working medium at the inlet and outlet of the pipe, m 3 /kg To the total pressure drop, the acceleration pressure drop is negligible. 3. Position deviation correction It is the first task of the performance test to make clear the interface of the measuring system and determine the position of the measuring points. Usually, the measuring points are not in the guaranteed position, it is necessary to make corrections. 3.1. Gravity Difference Correction When the measuring device and the measured point are not in a horizontal plane, the correction of the gravity difference which comes from the liquid column in the transfer pipe should be taken into account. In Figure 1, the pressure gauge or transmitter and the taps are not on the same level, assuming that the Reading of pressure gauge or transmitter1 is p 1 (MPa),the Reading of pressure gauge or transmitter2 is p 2 (MPa), uncorrected pressure drop is p 1 -p 2. The pressure deviation which comes from the liquid column in the transmission pipe is expressed as follows [3] (8) 3

= additional pressure drop caused by the vertical height of the liquid column in the transmission pipe, MPa h= vertical height difference between the center point of pressure gauge or transmitter and pressure taking port, m g= gravitational acceleration, 9.807m/s 2 = refrigerant density, kg/m 3 pressure gauge or transmitter1 outlet pipe inlet pipe pressure gauge or transmitter2 The corrected pressure drop is: Figure 2. Gravity difference diagram1. H=vertical height difference between the center point of pressure gauge or transmitter and pressure taking port, m The height difference H were the relative value, when the pressure gauge or transmitter above tap, the height difference H is positive; when the pressure gauge or transmitter below tap, the height difference of H negative. In Figure 1, H1 is positive, H2 is negative; in Figure 2, H1 negative, H2 positive. (9) inlet pipe pressure gauge or transmitter 2 pressure gauge or transmitter 1 outlet pipe Figure 3. Gravity difference diagram2. 4

3.2. Pipeline Resistance correction Pressure drop guaranteed by boiler plant is usually the drop from the inlet header to the outlet header of the heating surface. Considering convenient construction and instrument installation conditions, pressure measuring points are generally not installed in the header, but installed in the inlet and outlet pipe. There is a distance between the pressure measuring points to the header. This pipeline will certainly produce frictional resistance and there may be elbow, three, orifice plate, test valve etc. between the distances. These components will produce local resistance, in order to obtain the real value of heating surface resistance; the resistance caused by the pipeline should be subtracted. Take a power plant as an example. The guaranteed steam and water pressure from economizer to drum is 0.392MPa but the measured value is 0.562MPa. By searching the data, we found that there is a long distance between the inlet pressure measuring point and the inlet header of economizer, with elbow, flow orifice, check valve and other components, as shown in Figure 4. Inlet header of the economizer Inlet pressure measuring point Figure 4. Diagram of the inlet pressure measuring point. We should count up the distance between the inlet header of economizer and the pressure measuring point, height difference, radius and quantity of elbow, specifications and materials of the pipe, and then find the resistance coefficient of orifice plate and the valve through checking the table, followed by calculation of pipe resistance and local resistance. Through the calculation, the resistance is 0.229MPa, so the pressure drop after correction is (0.562MPa-0.229MPa=) 0.333MPa, which reached the design value of 0.392MPa. 4. Operating Parameter Deviation Correction Due to fluctuation of working conditions, the steam flow, pressure, and temperature may be different from the design value, then the physical parameters of the steam will change, and the pressure drop 5

will change. Assessment tests generally require pressure drop under design parameters; therefore, the deviation of the operating parameters should also be corrected. 4.1. Pressure Drop of Reheater For the pressure drop of reheater, the gravity pressure drop can be neglected, and it is determined by frictional resistance and local resistance. According to the formula (2) (3) (4), we can get formula (10). To give reheater, friction coefficient and the local resistance coefficient is constant, the pressure drop is proportional to the square of the steam flow rate, and is proportional to the average specific volume of the steam. (10) A=sectional area of pipeline, m 2 k=, constant G-steam flow rate, kg/s Therefore, the pressure drop can be corrected by the following formula (11) operating parameter deviation correction, MPa =position deviation correction, MPa = design average specific volume, m 3 /kg = test average specific volume, m 3 /kg =design steam flow rate, kg/s = test steam flow rate, kg/s 4.2. Pressure Drop from Economizer to HP Superheater Outlet To the pressure drop from the inlet of economizer to the outlet of HP superheater, due to the phase transition of the working fluid (water in the economizer, steam and water in the water wall, superheated steam in the superheater),it is necessary to make subsection correction in order to get accurate results. The working fluid in the economizer is liquid water, the pressure drop mainly comes from the gravity pressure drop, and the change of the working condition has little influence on it, and the error can be ignored. When the precision requirement is not high, the gravity pressure difference of the economizer can be deducted on the basis of the correction of the position deviation of the pressure measuring point, and then do operating parameter deviation correction according to the formula (11).The final pressure drop is equal to the sum of the correction result and the gravity pressure difference of the economizer. 6

Another correction formula is given in reference [4], which can be corrected only according to the flow rate, and the result is similar to the result of formula (11). (12) 5. Calculation Example In the actual calculation, correction of steam and water pressure drop should be carried out according to the following steps. First the measured static pressure difference can be obtained according to the formula (1), and then the position deviation correction of measuring points should be carried out. Finally, the operation parameter deviation is corrected and we can get the final result. Table 1 is calculation of the steam and water pressure drop of the reheater. Table 1. Calculation of the steam and water pressure drop of the reheater. Item Unit Value G d -design steam flow rate t/h 2455.80 p din -design inlet pressure MPa 6.17 p dout -design outlet pressure MPa 5.98 t din -design inlet temperature 362.00 t dout -design outlet temperature 623.00 G t -test steam flow rate t/h 2329.80 p tin -test inlet pressure MPa 5.74 p tout -test outlet pressure MPa 5.53 t tin -test inlet temperature 354.00 t tout -test outlet temperature 614.00 -design average specific volume m 3 /kg 0.055 -test average specific volume m 3 /kg 0.059 measured static pressure difference MPa 0.203 pressure drop from inlet pressure extraction point to header MPa 0.047 pressure drop from outlet pressure extraction point to header MPa 0.006 pressure drop from inlet measuring point to transmitter MPa 0.020 pressure drop from outlet measuring point to transmitter MPa 0.020 MPa 0.110 operation parameter deviation correction according formula (11) MPa 0.114 corrections MPa 0.089 operation parameter deviation correction according formula (12) MPa 0.120 6. Conclusion This paper introduces the correction method of steam and water pressure drop in boiler performance test. The position deviation correction of measuring points and correction of operation parameter deviation are necessary. References [1] WU Shenglai, Zhao Yongjian, Guo Rui, Discussion on correction calculation of pressure loss in steam and water system by the ASME PTC4-2008 method, J. Thermal Power Generation. 42(2013) 132-134. [2] Henan Electric Power Survey & Design Institute. Hydrodynamics Calculation for Boilers. China Electric Power Press, Beijing, 2009. 7

[3] Jing Sirui, Zhang Mingyuan. Fluid mechanics. Xi an Jiaotong University Press, Xi an, 2008. [4] JB/Z201-1983, Hydrodynamic Calculation Method for Power Plant Boiler. [5] Xu, Y. Y., P. Dong, and R. H. Lan, Principle of calculations for hydrodynamic-loop analysis method used for natural circulation hot water boilers, J. Engineering for Thermal Energy & Power (2006). [6] Information on https://www.tlv.com/global/ti/. [7] Freeston D H,A comparison of experimental results of pressure drop for two phase steam/water and air/water mixtures in a horizontal pipe[c]// Institution of Engineers, Australia, 1980. 8