Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

Similar documents
Sensoric 4-20 ma Transmitter Board Operation Manual

Electro-Pneumatic Converter YT-940 SERIES

O3 3E 1 F Gas Sensor Module

Model B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Columbus Instruments

MODEL GT820 OXYGEN SENSOR

OEM Manual. MODEL ½ Digit DRUM SCALE

Datasheet: K-30 ASCII Sensor

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Installation, operating and maintenance Instructions for Seemag bypass level indicator

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

Operation and Maintenance Manual

MEC OEM. User Manual. Commercial in Confidence

RAI-M series RUDDER ANGLE INDICATOR SYSTEM

Operation Manual. Rev. C LPT Low Power Transmitter (Electrochemical Sensor)

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Installation and Operation Manual

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

Transmitter CS 21 Operation Manual

AMS 2710 PCB pressure sensor module with V output

Design Features. General Description

Connections The C20B can be connected either using the Molex locking socket, or by connection to four plated through holes. The plated through

Air Check Lite Toxic Gas Monitor

Operating Instructions

LVU2800 Series. Ultrasonic Level Transmitter

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

SX150A. Features. Typical Applications. Description

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

Gas density monitor With integrated transmitter Model GDM-100-TI

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

Model PDT Dewpoint Transmitter

EASIDEW TRANSMITTER with Current Source Output

Operating Instructions Part No

SDX Submersible Depth Transmitter User Manual

HLM-2000-TX Gas Transmitter User Manual

P499 Heavy Duty Pressure Transducer

Stand-Alone Bubble Detection System

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

DPC-30 DPC-100. Reference Manual

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

210 Series Transmitter with External Electrochemical Sensor

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Transmitter CS 21 Operation Manual

Instruction and Maintenance Manual

KING-GAGE. Calibration Instruction Manual. D/P LiquiSeal Purge Control and D/P Purge Control

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

HLM-2000-TX Gas Transmitter User Manual

RAM Operation Manual

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells.

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

INSTRUMENT MANUAL VP50 PROPORTIONAL CONTROL VALVE

OPERATION MANUAL F Y C A L M E

Operating Instructions Part No

EcoPRO-Series 4-20mA SUBMERSIBLE PRESSURE TRANSMITTER INSTRUCTIONS

Instruction and Maintenance Manual

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

ZIRCONIA OXYGEN DETECTOR SERVICE MANUAL

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

ACV-10 Automatic Control Valve

Operation and Maintenance Manual

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

AUTOMATIC GAS MANIFOLDS

! Warning, refer to accompanying documents.

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Procedure Troubleshooting the Interconnect Cables

Metham Aviation Design Limited, Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0)

Differential Pressure Transmiter

9700 Transmitter Submersible hydrostatic level transmitter

Wing Union/Hammer Union Pressure Sensors. Datasheet. Models 435/437

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

MEMS VOC Gas Sensor. (Model No.:GM-503A) Manual. Version: 1.0. Valid from: Zhengzhou Winsen Electronics Technology Co.

UNDERSTANDING, ACCELERATED

Operation manual Oxygen sensor

GEMS SENSORS & CONTROLS

RPS900W Redundant Power Supply. Installation Guide.

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

EC214 EC215 - EC215R Bench Conductivity Meters

Mass Flow Meter (MFM) for gases

TH-1800-T TRX-700-CNG Converter

RAM 4021-DPX Operation Manual

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008

INSTRUCTION MANUAL. FLOAT TYPE LEVEL TRANSMITTER HT-100R Series HITROL CO., LTD.

GAS FUEL VALVE FORM AGV5 OM 8-03

Toxalert International, Inc.

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

OXYGEN MONITORING SYSTEM OMS

ellison sensors international

P900. P900, Datenblatt Seite 1 DESCRIPTION

GPR-2500 / GPR-2500MO Oxygen Transmitter

User manual CF8-D/W-IN

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Transcription:

ALPHASENSE USER MANUAL Page 1 4-20mA Transmitter for Toxic Sensors UMTOX-1 Issue 4 1 INTRODUCTION The Transmitter PCB includes circuitry for a three electrode toxic sensor to convert the µa output signal from the sensor to a 2-wire 4-20mA signal. The transmitter board includes 4 mounting pillars that may be removed if not required. Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors: Transmitters are shipped pre-calibrated for immediate use. Circuitry includes onboard voltage regulator and uses low power two-wire transmitter systems, allowing the simplest possible wiring format. Small circuit board size allows smaller sensor housing. Conformally coated circuit board for environmental protection of circuit. Low power circuitry with excellent performance means no degradation of sensor performance due to electronics. Amplification of the sensor signal reduces noise pick-up and RFI/EMI susceptibility. Besides periodic sensor re-calibration, the transmitter electronics require no maintenance throughout the lifetime of the sensor. The sensor can be replaced at the end of the sensor working life. Re-calibration is required when the sensor is changed. See section 6. Please read these instructions to ensure correct installation, use and calibration of your gas sensor/ transmitter. 2.1 Transmitter Specification Input Voltage Required Output at zero gas concentration Output at full-scale Setability /stability Maximum load @ 20 ma, 24 VDC Supply voltage dependence +7.5 to + 35 VDC 4mA (user adjustable) 20mA (user adjustable) <0.05mA (<0.25% FS) 825 ohms (see note) < ±0.2 % output from +7.5 to +35 VDC Connector 2 pin Molex plug (ref. 22-27-2021) PCB current requirement <100 µa PCB dimensions Operating conditions Calibration (shipped pre-calibrated) Power supply protection No-power equivalent circuit 39mm (dia.) x 19 mm (height) See sensor specification multi-turn zero and span potentiometers Diode protection to voltage regulator Electrodes short- circuited via FET

UMTOX-1 Page 2 2.2 Range/Options Sensor and transmitter boards are shipped from Alphasense pre-calibrated. You may wish to confirm calibration. Standard available ranges are listed below: Sensor Ordering Code (includes sensor) Full-Scale Gas Concentration (ppm) Gain CO-BF THCO-BF 1000 Low CO-BF TLCO-BF 100 High H2S-BE THH2S-BE 1000 Low H2S-B1 THH2S-B1 200 Low H2S-B1 TLH2S-B1 25 High SO2-BF THSO2-BF 100 Low SO2-BF TLSO2-BF 20 High NO2-B1 THNO2-B1 50 High NO2-B1 TLNO2-B1 10 High CL2-B1 TLCL2-B1 10 High Table 1: Transmitter ordering code Although the sensor and transmitter are pre-calibrated and the ranges are preset, it is possible to change range by adjusting the zero and gain potentiometers, which changes the circuit gain. Different sensors can be fitted to a transmitter board; if the gain is in the same category (low or high), then only re-calibration is necessary. If the sensor gain is different, then contact Alphasense for instructions on how to change range. Nitrogen dioxide and Chlorine (NO 2 and Cl 2 ) sensors give negative outputs, so Cl 2 and NO 2 transmitters (THNO2-B1, TLCL2-B1 and TLNO2-B1) will not accept other sensors (CO, H 2 S, SO 2 ), since they have an additional op amp stage to correct for this inverted output. See section 6. 3 Set Up 3.1 Mechanical Mounting Transmitters are mounted to your housing using the four pillars pre-mounted to the PCB. Two sets of mounting holes are provided so that the sensor/pcb can be fixed to either the housing top (using the locating holes in the corner of the PCB) or to the base of the housing (using either set of locating holes). Figure 1 below shows mounting hole locations (dimensions are in mm). Figure 2 diagrams the sets of locating holes; normally the outer holes are used for mounting, while the inner e in the same location as the earlier issue of this PCB, allowing backward compatibility with the earlier PCB design. 19.5 32 39 19.5 32 39 Figure 1. Outer mounting hole locations. Figure 2.Inner and outer mounting holes.

UMTOX-1 Page 3 The pillars are tapped to accept an M3 pan head screw. We recommend a screw length that is at least 8mm to ensure rigid fixing. It is good practice to hold the pillar when screwing into the pillars to stop the pillar from rotating on the PCB. It may be easier to remove the sensor whilst screwing the circuit board pillars to your housing. If you move the pillars, ensure that if mounting to the lid of your housing that you include the washer between the pillar and PCB to ensure correct height of the pillar assembly. See figures 3 and 5. M3 M3 Span Connector Zero Washers MUST be fitted both sides Span Connector Zero Figure 3. Mounting pillar configuration for attaching to the lid of an enclosure..figure 4. Mounting pillar configuration for attaching to the base of an enclosure. 16.5 20 M3 Pillars Washers MUST be fitted both sides Figure 5. Side view of mounting to lid of an enclosure. Figure 6. Side view of mounting to the base of an enclosure. Allow 20 minutes after plugging the sensor back into the board for the output to stabilise. Ensure that the sensor is sealed securely to the top face of your housing. The O-ring supplied with your transmitter sensor should be used to ensure an airtight seal, avoiding any access of toxic or corrosive gases to the circuit board and the housing interior.

UMTOX-1 Page 4 3.2 Connection and Wiring Power to the transmitter board is via a Molex 2-pin mini plug (type 22-27-2021: supplied with the transmitter). Connect using a screened, two-core cable to the wires (black is ground, red is positive) by either soldering or using a screw terminal block. Twisted pairs can be used for shorter cable lengths. These leads can be shortened or extended as needed. 3.3 Power Supply Your power supply must be between 7.5 and 35 VDC with less than 0.2V ripple. Do not supply mains AC power to this unit: this will destroy the transmitter and void the warranty. The transmitter is protected against incorrect polarity but will not function if you have reversed the power supply wires by connecting the Molex plug incorrectly to the transmitter board socket. When selecting the power supply voltage, you must not exceed the maximum total loop resistance, which includes your measuring resistor used to change the 4-20 ma current into a measured voltage. The transmitter requires a minimum of 7.5 volts to operate; therefore, the maximum potential drop allowed across your sensing resistor and cable is: (power supply voltage) -(7.5V) Assuming full-scale deflection at 20 ma, use Ohm's law to calculate the maximum loop (cable plus sensing resistor) resistance allowed. 4 Correct Usage and Maintenance Ensure there is a good gas seal between the sensor and the housing; also if the sample is pumped, then ensure that the flow rate is sufficient. Alternatively, the sample gas can be allowed to diffuse to the front face of the sensor. The table below shows the recommended gas flow rate in standard cubic centimetres per minute (sccm). Higher flow rates may be used, but beware that pulsing flow and higher-pressure drops may lead to more erratic readings. Gas Flow Rate (sccm) CO 300 to 500 H 2 S 400 to 700 SO 2 400 to 700 Cl 2, NO 2 400 to 700 Table 2: Pumped gas recommended flow rates The only maintenance required is changing of the O-ring if it has been exposed to extreme environments for long periods (this O-ring should last the lifetime of the sensor in normal conditions). In addition, if the top dust/oil filter has become badly contaminated then contact Alphasense for replacement dust filter (section 5).

UMTOX-1 Page 5 5 Reordering Part Numbers Replacement sensor O-rings and dust/oil filters can be ordered by quoting the part numbers below. Part Number Description 033-0002-00 Replacement O-ring 024-0011-00 Self-adhesive dust/oil filter Table 3: Replacement Part Numbering 6 Calibration The 4-20mA transmitter is shipped pre-calibrated to the range shown in Table 1. Periodic re-calibration is required for all gas sensors, especially in safety-critical applications. To Calibrate: 1 First ensure that the power supply is connected correctly and a tight fitting flow hood is in place. 2 Ensure that a high quality zero gas source is available (e.g. cylinder of zero air or cleaned and scrubbed compressed air) and a bottle of calibration gas with validated accuracy (see Table 5 below). 3 Apply zero gas for 10 minutes at the flow rate shown in Table 2. Using a small screwdriver, adjust the zero potentiometer (RP2) until the reading is 4.00 ±0.05 ma. See figure 1, attached to this manual. 4 Apply test gas for ten minutes; the recommended test gas concentration for calibration is shown below in Table 4. Adjust the span potentiometer (RP1) with a small screwdriver until the reading is within ± 0.05 ma of the Span Calibration Point shown in Table 4 if you are using the recommended concentration. 5 Although it should not be necessary, it is good practice to recheck the zero after setting the span to ensure that the output is still 4.00 ± 0.05 ma in clean air ("zero gas"). Allow at least 10 minutes for full recovery to zero after the calibration gas has been removed. Transmitter Full-Scale (ppm) Calibration gas (ppm) Span Cal Point (ma) THCO-BF 1000 400 10.40 TLCO-BF 100 100 20.00 THH2S-BE 1000 400 10.40 THH2S-B1 200 50 8.00 TLH2S-B1 25 20 16.80 THSO2-BF 100 50 12.00 TLSO2-BF 20 10 12.00 THNO2-B1 50 25 12.00 TLNO2-B1 10 5 12.00 TLCL2-B1 10 5 12.00 Table 4: 4-20 ma Transmitter Span Calibration UMTOX-1 Page 6

7 Warranty Transmitters are warranted for two years. Sensors are warranted separately. If you have any difficulties or problems then contact: Customer Support Alphasense Limited Sensor Technology House 300 Avenue West Skyline 120 Great Notley Essex United Kingdom CM77 7AA Tel: +44 (0) 1376 556 700 Fax: + 44 (0) 1376 335 899 email: sensors@alphasense.com 8 Attachments Figure 7 Circuit diagram

αlphasense Ltd Sensor Technology House, 300 Avenue West, Skyline 120, Great Notley, Essex, UK CM77 7AA Tel: +44 (0) 1376 556 700 Fax: +44 (0) 1376 335 899 e-mail: sales@alphasense.com web: www.alphasense.com