gait phases analysis. In the study by S. K. Ng and H. J.

Similar documents
Development of Wearable Sensor Combinations for Human Lower Extremity Motion Analysis

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system

Dynamic analysis and motion measurement of ski turns using inertial and force sensors

Stride October 20, 2017

Computer Aided Drafting, Design and Manufacturing Volume 26, Number 2, June 2016, Page 53. The design of exoskeleton lower limbs rehabilitation robot

Robot motion by simultaneously wheel and leg propulsion

Generation of Robot Motion Based on Measurement of Human Movement. Susumu Sakano 1, Satoru Shoji 1

WALKING MOTION ANALYSIS USING SMALL ACCELERATION SENSORS

Analysis of stroke technique using acceleration sensor IC in freestyle swimming

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and


Jogging and Walking Analysis Using Wearable Sensors *

A MODIFIED DYNAMIC MODEL OF THE HUMAN LOWER LIMB DURING COMPLETE GAIT CYCLE

Body Stabilization of PDW toward Humanoid Walking

Step Detection Algorithm For Accurate Distance Estimation Using Dynamic Step Length

APPLICATION OF THREE DIMENSIONAL ACCELEROMETRY TO HUMAN MOTION ANALYSIS

Shoe-shaped Interface for Inducing a Walking Cycle

Clinical Application of Acceleration Sensor to Detect the Swing Phase of Stroke Gait in Functional Electrical Stimulation

ZMP Trajectory Generation for Reduced Trunk Motions of Biped Robots

Takashi Watanabe, Hiroki Saito, Eri Koike, and Kazuki Nitta. 1. Introduction

Impact Points and Their Effect on Trajectory in Soccer

Simulation of the Hybtor Robot

Friction properties of the face of a hand-held tennis racket

Biomechanics and Models of Locomotion

Improving pedestrian dynamics modelling using fuzzy logic

NIH Public Access Author Manuscript Gait Posture. Author manuscript; available in PMC 2009 May 1.

REPRESENTATION OF HUMAN GAIT TRAJECTORY THROUGH TEMPOROSPATIAL IMAGE MODELLING

Trajectory Planning for Smooth Transition of a Biped Robot

ZSTT Team Description Paper for Humanoid size League of Robocup 2017

ACTIVITY MONITORING SYSTEM

Controlling Walking Behavior of Passive Dynamic Walker utilizing Passive Joint Compliance

Using GPOPS-II to optimize sum of squared torques of a double pendulum as a prosthesis leg. Abstract

An Indoor Positioning Method with MEMS Inertial Sensors

RATE CONTROL SYSTEM FOR SOUNDING ROCKETS

Modeling of Hydraulic Hose Paths

Motion Control of a Bipedal Walking Robot

Gait Recognition with Fuzzy Classification Using Shoulder Body Joint

AN31E Application Note

SCHEINWORKS Measuring and Analysis Systems by

Intelligent Decision Making Framework for Ship Collision Avoidance based on COLREGs

Video Based Accurate Step Counting for Treadmills

Modeling and Analysis of the Control System Drive in an Artificial Limb

EXSC 408L Fall '03 Problem Set #2 Linear Motion. Linear Motion

Gait Analysis at Your Fingertips:

Dynamically stepping over large obstacle utilizing PSO optimization in the B4LC system

CHAPTER IV FINITE ELEMENT ANALYSIS OF THE KNEE JOINT WITHOUT A MEDICAL IMPLANT

Biped Walking Robot Control System Design

MEMS Sensors for Smart Living: ITRI Solutions. Chris Chen, ITRI

Use of On-Body Sensors to Support Elite Sprint Coaching

+ t1 t2 moment-time curves

Figure 1 betois (bending torsion insole system) system with five measuring points and A/D- converter.

Compliance Control for Biped Walking on Rough Terrain

The three steps for biomechanical assessment are the following: > Periodically verify the results and the efficacy of treatment

Gait Recognition. Yu Liu and Abhishek Verma CONTENTS 16.1 DATASETS Datasets Conclusion 342 References 343

INCLINOMETER DEVICE FOR SHIP STABILITY EVALUATION

SHUFFLE TURN OF HUMANOID ROBOT SIMULATION BASED ON EMG MEASUREMENT

Emergent walking stop using 3-D ZMP modification criteria map for humanoid robot

IMPLEMENTATION AND ANALYSIS OF FUZZY-ZMP-WALKING CONTROL IN THE GIMBIPED

Electronic Automatic Transmission for Bicycle

Datalogging Shirt for Baseball Pitchers

A System Development for Creating Indoor Floor Plan of Walking Route using Video and Movement Data 1 2

Wave phenomena in a ripple tank

A Feedback System for the Motor Learning of Skills in Golf

Toward a Human-like Biped Robot with Compliant Legs

EXPERIMENTAL STUDY OF EXOSKELETON FOR ANKLE AND KNEE JOINT

The Design of ZMP Measure System for Biped Robot LI Bin 1, a, LI Zhihai 2, b, LI Jiejia 1, c, BU Chunguang 2, d

Novel Technique for Gait Analysis Using Two Waist Mounted Gyroscopes

TOWARDS A SMART SYSTEM OF IDENTIFYING STEPS FOR PREDICTING FALL IN PEOPLE WITH DISABILITIES

Development of a Simulation Model for Swimming with Diving Fins

Basic walker-assisted gait characteristics derived from forces and moments exerted on the walker s handles: Results on normal subjects

In memory of Dr. Kevin P. Granata, my graduate advisor, who was killed protecting others on the morning of April 16, 2007.

Programming Self-Recovery in the humanoid Leong Ti Xean 1 Yap Kian Tiong 2

Artifacts Due to Filtering Mismatch in Drop Landing Moment Data

Modeling and simulation of multiple personal mobility. vehicles in pedestrian flows using personal space

Gait analysis for the development of the biped robot foot structure

Walking Control Algorithm of Biped Humanoid Robot on Uneven and Inclined Floor

1 INEGI Instituto de Engenharia Mecânica e Gestão Industrial, Porto, Portugal, FEUP Faculdade de Engenharia,

Design, Fabrication and Analysis of Microcontroller Based Bipedal Walking Robot Vaidyanathan.V.T 1 and Sivaramakrishnan.R 2

A NEURAL PROSTHESIS TO IMPROVE GAIT IN PEOPLE WITH MUSCLE WEAKNESS

ROSE-HULMAN INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering. Mini-project 3 Tennis ball launcher

Brief Biomechanical Analysis on the Walking of Spinal Cord Injury Patients with a Lower Limb Exoskeleton Robot

Characteristics of ball impact on curve shot in soccer

Simulation analysis of the influence of breathing on the performance in breaststroke

Specifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS)

MOVEMENT QUALITY OF MARTIAL ART OUTSIDE KICKS. Manfred Vieten and Hartmut Riehle University of Konstanz, Konstanz, Germany

Foot side detection from lower lumbar spine acceleration

Gait Analyser. Description of Walking Performance

Joint Torque Evaluation of Lower Limbs in Bicycle Pedaling

Accelerometers: An Underutilized Resource in Sports Monitoring

Using sensory feedback to improve locomotion performance of the salamander robot in different environments

Mutual and asynchronous anticipation and action in sports as globally competitive

Mobility Lab provides sensitive, valid and reliable outcome measures.

GOLFER. The Golf Putting Robot

Impedance Control for a Golf Swing Robot to Emulate Different-Arm-Mass Golfers

Decentralized Autonomous Control of a Myriapod Locomotion Robot

Development of Fish type Robot based on the Analysis of Swimming Motion of Bluefin Tuna Comparison between Tuna-type Fin and Rectangular Fin -

J. Electrical Systems 11-2 (2015): Regular paper. Abnormal gait detection using Hexagonal method on Model based Front view model

A Novel Gear-shifting Strategy Used on Smart Bicycles

Skippy: Reaching for the Performance Envelope

PERCEPTIVE ROBOT MOVING IN 3D WORLD. D.E- Okhotsimsky, A.K. Platonov USSR

Transcription:

Proceedings 2005 IEEE International Symposium on Computational Intelligence in Robotics and Automation June 27-30, 2005, Espoo, Finland A Wearable Inertial Sensor System for Human Motion Analysis Tao Liu, Yoshio Inoue, Kyoko Shibata Department ofintelligent Mechanical Systems Engineerin} Kochi University oftechnology 185 Miyanokuchi, Tosayamada-cho, Kochi Japan 782-8502 078008g@gs.kochi-tech.ac.jp Abstract - To analyze the multi-dimension motion of human foot during walking, a wearable inertial sensor system is proposed. In this system, two gyroscopes (ENC-05EB) were used to measure angular velocities in x- and y- directions, and an accelerometer (ADXL202) was used to measure acceleration in x- and y- directions respectively. Furthermore, a fuzzy inference system (FIS) was developed for the calculation of the gait phases derived from sensors' outputs. A digital filter was also designed to remove noises from of the output of the fuzzy inference system, which enhances robustness of the system. Finally, experimental study was conducted, and a wearable mechanism with the sensors system was constructed to detect gait phases of the normal human walking. Index Terms -human motion analysis; motion sensor; gait phases; fuzzy inference. I. INTRODUCTION Gait analyses have been found in many application fields: functional electrical stimulation (FES) for restoring patents' walking function; human dynamic analysis system to finish force and motion analysis, when some force sensors are integrated; humanoid robot including assistant mechanism for walking. In daily life, human dynamics analysis is becoming important, for example, the gait analysis of pregnant woman can illustrate the different body dynamic conditions that ankle joint moment and hip joint moment are much larger than non-pregnant women. Based on gait phase analysis, the assistant and rehabilitative devices can be developed for pregnant woman or patients [1]. The integration of three-dimension motion measurement using multi-camera system and ground reaction force measurement using force plates has been successfully devoted to tracking human body parts and performing dynamics analysis of their physical behaviors in a complex environment [2][3]. However this method needs sizeable work space and high-speed graphic signal processing devices, therefore it is inefficient in real time controls and is too expensive for daily product developments. Moreover, human body is composed of many highly flexible segments, and the up-body motion of human is especially complicated for accuracy calculations. Thus, in the development of cheaper and more comfortable gait analysis device, several sensor combinations, including force sensitive resistors, inclinometer, goniometers, gyroscopes and accelerometers, were proposed to perform Xueyan Tang School ofmechanical and Production Engineering Nanyang Technological University Singapore 639798 TANG0031@ntu.edu.sg gait phases analysis. In the study by S. K. Ng and H. J. Chizeck [4], measurements from goniometers at the hip, knee and ankle joints were used in combination with a fuzzy model classification method to detect five different gait phases. However, the method suffered from frequency detection errors, and the measure devices also make human feel uncomfortable. In [5], K. Tong and H. M. Grant proposed a measurement device using two gyroscopes, one placed on the thigh and the other one on the shank, which can estimate knee rotation angle during walking. This system can detect difference phases of human walking, but the dispersed measurement system may affect user walking. In [6], R. Willemsen et al. proposed a detection system using accelerometers, but this system just can separate stance phase and swing phase from the human walking gait phases. Ion P.I. Pappas al. in [7] used a detection system consisting of three force sensitive resistors that measure the force loads on a shoe insole and a miniature gyroscope chip that measures the rotational velocity of the foot. The system detects accurately and reliably the four gait phases in real time, but it was just designed for the application of functional electrical stimulation. To finish the 3-D human dynamic analysis by using some wearable devices, in our study, we have developed a system composed of a wearable motion analysis system and a wearable 6-D force sensor. We will use the developed 6-D force sensor [8] to measure reaction forces and moments in three directions, and use the motion analysis system to detect 3-D motion of human motion during walking. The results of motion analysis and force analysis will be combined to finish dynamic analysis of human's walking. In this paper, we focus on the design of motion analysis system for gait analysis during human's walking. The motion analysis system was designed as a different sensors combination consisting of two gyroscope-chips that measure two-direction rotational velocities of the foot and a two-axis accelerometer-chip that can output twodirection accelerations of the foot during walking. Furthermore, a fuzzy inference system (FIS) was developed for the analysis of sensors' outputs, which can estimate a gait phase analysis result. To get the decided gait phases change points of human walking, a digital filter was used to remove noises from the outputs of the fuzzy inference system. Finally, experimental study was conducted. A wearable mechanism with the sensors system 0-7803-9355-4 / 05 / $20.00 2005 IEEE. 409

was constructed, and some experiments about detection gait phases of the normal human walking were finished. II. METHODS AND MATERIALS Hardware Description of the Inertial Sensor System The gait analysis system perfonns the detection of gait phases by using two types of inertial sensors, i.e.. two gyroscopes used to measure angular velocities of two-axis on the foot plane during walking, and a two-axis accelerometer used to measure total transmission accelerations including gravity acceleration and dynamic acceleration along two sensitive axis. As shown in Fig. 1, an electrical base board was designed for the inertial sensor system. Two miniature gyroscopes (Murata ENC-03J, size 15.5x8.0x4.3 mm, weight 10 g) were integrated on the base board with their sensing axis oriented on the bottom plane of the foot respectively. The two gyroscopes can measure twodimension rotations of the foot in that, plane. The Murata ENC-03J gyroscope measures the rotational velocity by sensing the mechanical deformation caused by the Coriolis force on an intemal vibrating prism. The gyroscope signal is filtered by a third-order band-pass filter (0.25-25 Hz) with a 20-dB gain in the pass band. The frequencies outside the pass-band were filtered out because they are not related to the walking kinetics. The filtered gyroscope signal was used to directly estimate the angular velocity of the foot and it was integrated to estimate the inclination of the foot relative to the ground. The accelerometer-chip with almost the same theory as gyroscope-chip was fixed on the back of the base board, which can measure two-axis accelerations including gravity acceleration and dynamic acceleration during walking. In the design of data record device, the sampling time of A/D module is selected according to the bandwidth of signals, and the sampling frequency should be higher than 2x 1.25x25 Hz (the bandwidth of the inertial sensors' signals is about 25 Hz) [9]. Therefore the sensor signals were sampled at a frequency of 100 Hz>62.5 Hz with a resolution of 14 bits through A/D card (Keyence NR-1 10), and the sample data is saved into the person computer for the analysis. The card is connected with computer through micro-card interface of PCMCIA2.1 in personal computer. Because the two kinds of inertial sensors are low energy consumed electrical devices, the motion analysis system is powered by using two button batteries (CR2032), which can work up to 30 minutes in walking experiments. A. (a) Front of the board Fig. ' Hardware device of the motion anlysis system A mechanical shoe (see Fig. 2) was designed to fix the base board of inertial sensors. The foot plane is parallel to the base board. The material was selected as Aluminum, and the weight is about 500 g, the size is almost the same as common shoes. B. Physics Sense Analysis of Gait Phases In this paper, a normal walking gait cycle is divided into four different gait phases, i.e., stance, toe-rotation, swing, and heel-rotation. The following is the definition of the gait phases (see Fig. 3): let stance phase be the period when the foot is with its entire length in contact with the ground; let toe-rotation phase be the period following the stance phase during which the front part of the foot is in contact with the ground and its heel is rotating around toe joint; let swing phase be the period when the foot is in the air (not in contact with the ground); let heel-rotation phase be the period following the swing phase which begins with the first contact of the foot with the ground (usually the heel, but not necessarily) and the front part of foot is rotating around heel's contacting point, which ends when the entire foot touches the ground. We define a walking cycle as the period from one stance phase of the foot to the next stance phase of the same foot. In gait phase analysis algorism, these gait phases were represented by a mathematics method with four distinct value ranges. The loop frequency of the phase record was 100 Hz, i.e., equal to the sensors sampling frequency. (b) Back of the board Fig. 3 Transition of four gait phases Fig. I Base board of the sensor system 410

.- s i. Fig. 5 Theory schematics of thefis Fig. 4 Wearable motion analsys mechanical device Physics sense analysis of each phase was performed to design rules for the gait phase detection algorithm. As shown in Fig. 4, when the motion measure device wears under the foot, we suppose the subject is viewed from the lateral side and clockwise rotations are considered positive. The Z- axis is vertical to the foot plane, and X- axis and Y- axis are along length- and wideorientations of foot respectively. The symbols oxx and coy represent the rotational velocity of foot around X- axis and Y- axis respectively. Physics senses of each phase can be defined as following: 1). If Ox= AND w)y O AND Ax=O AND Ay-O Then 'Stance Phase'; 2). If coy<o AND Ax#O AND Ay#O Then 'Swing Phase'; 3). If o,y>0 AND AX#O AND Ay,,#O Then If the case is before the 'Swing Phase' of the same walking cycle Then 'Toe-rotation Phase' Else 'Heel-rotation Phase'. prepare C. Design of a Fuzzy Inference System When the experiments data are recorded in the hard-disk of personal computer, the off-line analysis is made to analyze the gait during walking. The inertial sensors output signals are easy to be affected by interrupts from testing environmental noise, and the static float of the inertial sensors can decrease the precision of the measurements in the case of long time testing, so in the study, a fuzzy inference system (FIS) is proposed to improve precision of the detection of gait phase. The fuzzy system is robust to the noise from the inertial sensors. We design the fuzzy inference system by using software of MATLAB (see Fig. 5). The two gyroscopes' outputs and the accelerometer's two-axis outputs are defined as the four inputs of the FIS, and the output of FIS is a value of gait phases. In the design of fuzzy inference system, Mamdani fuzzy inference method was used as the inference method. Each fuzzy input was defined as three fuzzy ranges: negative, zero and positive (see Fig. 6), and each fuzzy range was designed by using saw-tooth function. In the same way, the output of FIS was defined as four fuzzy ranges to de-fuzzy inference results in the Mamdani method. As shown in Fig. 7, the four output ranges is named as: stand, toe-r, swing, and heel-r respectively. ::.-.. -...^.:. Fig... 6uct...ion.o w... ------ fuzzyinput. Fig. 6 Fuction of fulzzy input *; 7:.0.0-. :9@.ne.......... :;. -:-;.;:V.: T s. -:... -.: -- :.....El ---:. -.^,...... - t.:....:.. -. N } *W Fig. 7 De-fizzy output of the FIS D. Design of a Digital Filter In this section, a digital filer designed for the outputs of FIS is presented. The inertial sensors are sensitive to the environmental noise, which leads to the difficulty of detecting the gait phases precisely using a simple algorithm in a micro-computer. To get the decided gait phases change points of human walking, a digital filter is used to remove noise results from the fuzzy inference system. We recorded the inertial sensor system's signals at a frequency of 1OOHz, and the normal human walking period is about 1.5 sec, so in the results of FIS the pulse interrupts with period of no over 0.05 sec can be confirmed as the errors pulses in the gait phase detection. A digital filter was designed to filter the error pulses in the results of FIS. The symbols R(i) and Rf(i) represent the output result of FIS and last filtered results on the i-th sampling cycle (i=2,3,4...), and k represents the noise pulse swing value. Then the rule of the filter is designed as follows. If the absolute value of R(i-1) subtracted by R(i+3) is far no more than k, and one of the absolute value among R(i) subtracted by R(i-1) R(i+1) subtracted by R(i-1) and R(i+2) subtracted by R(i-1) is larger than k, then the value of R(i), R(i+1) and R(i+2) is set as the same value as R(i1), because in this case the 50ms sampling range (from i-1 to i+3) must be added in a noise pulse (see Fig. 8)., 411

Tor-P-T Hel swing W--- --------- --- J +L L -j ~ R(i>-?*RiR(i) ao ci r3 Stnc Fig. 8 Theorv of the digital filter III. EXPERIMENTAL STUDY An experimental study was carried out in order to quantify that the motion analysis system can be used on normal gait phases detection for the future motion analysis study. The study involved a group of healthy adults who worn the special mechanical shoes on the one foot. The inertial sensors' data were recorded in the personal computer through the A/D card with resolution of 14 bits. All the subjects walked on a plane ground (length 30 m), = and their gait cycle is about 1.5s. The gait phases were analyzed off-line based on the data from the two kinds of inertial sensors. A. Formal Part ofexperiment After calibrated to be zero when no motion and adjusted to change from -2.5 to 2.5 in the same range, the four-output data from inertial sensors were fed into the fuzzy inference system according to sampling time cycle. As shown in Fig. 9, one subject's motion data were recorded about using x- axis gyroscope, y- axis gyroscope, x- axis accelerometer, y- axis accelerometer respectively. I 0 101 200 3 405000 10 720 80C 00 100 itx- 1EJ 14 01-17010 _ Tiune (loms) --- 5GroX A,.I.X L- Acele?Y EIXI Tor-R1Ieel-nR Stanlce 0 100 200 300 400 5,00 600 700 SO0 0 1000 1100 1200 1301 1400 150Q 1600 1700 1800 Time (1Oms) Fig. 10 Inference result of the FIS ii H K Li.vhJv JJLLJ.. 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 300 140 1500 1600 1700 1800 Time (loms) Fig. I I Filtered inference result of the FIS - :I Figure 10 shows the inference result graph of the fuzzy inference system, in which the stance phase and swing phase can be clearly divided and the toe-rotation phase and the heel-rotation phase are separated by the swing phase. However, the noise pulses in the result graph make it is difficult that the real separate points of each gait phase are detected from the reference results. B. Post-part ofexperiment In this section, the post-process of inference results is presented. A digital filter was designed to filter the error pulses in the results of FIS. Figure 11 shows the filtered results of gait phase analysis algorithm. In the analysis, the sampling cycle is 10 ms, and table 1 lists the sampling numbers of every transition point in the all walking cycle. The object's gait phase analysis results graph was regenerated to prepare for the motion analysis of walking in the future study. Fig. 9 Four recorded signals of the inertial sensors 412

Hleel-R j " T reactions force measurement system is integrated into this analysis system.,tor-r _-------- --------r---@----j l*-f--r i -l.'' It....1.1...1, I O0 0 0 Z40506070809 00 lolo 3010 SO10 70lO I~~~~Tm Ilms 00 0 0 0 6D 70 0 90 10 10 120 130 140 150 6-701. lml lmi Fig. 12 Gait phase analysis result of a object TABLE I.GAIT PHASES TRANSITION POINTS OF AN OBJECT Transition time (1 Oms) cycle Gait phases transition number Stance to Toe-r to Swing to Heel-r to Toe-r Swing Heel-r Stance l 309 336 385 404 2 464 493 544 568 3 629 656 705 721 4 785 809 867 890 5 950 985 1034 1053 6 1117 1145 1195 1215 7 1285 1307 1356 1376 8 1451 1476 1529 1551 REFERENCES [1] Gerald F. Harris, Peter A. Smith, "Human Motion Analysis," Reading, IEEE, Inc., 1996. [2] I.A. Karaulova, P.M. Hall, A.D. Marshall, "Tracking people in three dimensions using a hierarchical model," Elsevier Science, Image and Vision Computing, Vol.20, pp.691-700, 2002. [3] Yoshio Inoue, Takuya Matsuda, Kyoko Shibata, "Estimation of vertical reaction force and ankle joint moment by using plantar pressure sensor," JSME, Symposium on human dynamics, pp. 57-62, 2003. (In Japanese) [4] S. K. Ng and H. J. Chizeck, "Fuzzy model identification for classification of gait events in paraplegics," IEEE Trans. Fuzzv Syst., vol. 5, pp 536-544, Aug. 1997. [5] K. Tong and H. M. Granat, "A practical gait analysis system using gyroscopes," Med Eng. Phys., vol. 21, pp. 87-94, 1999. [6] R. Williamson and B. J. Andrews, "Gait event detection for FES using accelerometers and supervised machine learning," IEEE Trans. Rehab. Eng., vol. 8, pp. 312-319, June 2000. [7] Ion P. I. Pappas, Milos R. Popovic, Thierry Keller, Volker Dietz, and Manfred Morani, "A reliable gait phase detection system," IEEE Trans. Rehab. Eng., vol. 9, No. 2, pp. 113-125, June 2001. [8] Tao Liu, Yoshio Inoue, Kyoko Shibata, Yohei Yamasaki, Masafumi Nakahama, "A Six-dimension Parallel Force Sensor for Human Dynamics Analysis," Proceedings of the 2004 IEEE Conference on Robotics, Automation and Mechatronics Singapore, pp. 208-212, 2004. [9] S. M. Sze "Semiconductor Sensors. Wiley," New-York, USA, 1994. lv. CONCLUSION A different motion analysis sensor that reliably identified the gait phase transitions between stance, toerotation, swing, and heel-rotation, was presented. This offline analysis system was based on a set of inertial sensors combination including two miniature gyroscopes and a miniature two-axis accelerometer, which were integrated on a based board to be wom under foot. The sensor signals were sampled at a frequency of 1OOHz with a resolution of 14 bits through A/D card, and the sample data is fed into the person computer for the off-line analysis. A fuzzy inference system (FIS) was designed to improve precision of the detection of gait phase. A digital filter is used to remove noise results from the outputs of fuzzy inference system. In experimental study, the gait phase detections were finished successfully on a group of healthy objects. In the future, the results of gait phase analysis can be used for multi-dimension motion analysis of walking, and a dynamic analysis of walking can be finished when a 413