GLAUNACH THE SILENCER HANDBOOK SILENCERS AN OVERVIEW OF OUR PRODUCT PORTFOLIO GLAUNACH GMBH ALL RIGHTS RESERVED -

Similar documents
GLAUNACH THE SILENCER HANDBOOK INSTALLATION GLAUNACH GMBH ALL RIGHTS RESERVED -

Atmospheric Vent Silencers. Industrial & Marine Silencers

ADVANCES in NATURAL and APPLIED SCIENCES

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

PERKFILTER. Inspection and Maintenance Guide

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Natural Gas Conditioning Skids & Equipments

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs.

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

Pneumatic Conveying Principles BSH&E SEMINAR

NORMAL OPERATING PROCEDURES Operating Parameter Information

S and SF Inverted Bucket Steam Traps

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

RD(H)20/25 Pressure-Reducing Regulator User Manual

Thanks for choosing EJAI SOLAR product

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

SRI Jigger Tubes System

Inerted Vessels: Preventing Hazards Caused by Gas Buoyancy

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

for Stainless Steel Lines of Pressure Vessels, Hot Water Boilers, Heat Exchangers, Secondary Side of Pressure Reducing Valves etc.

STD Spray Type Desuperheater

FV Flash Vessel Installation and Maintenance Instructions

DUAL-VORTEX SEPARATOR. Inspection and Maintenance Guide

Operating Instructions

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG)

DF1 and DF2 Diffusers

VAD Variable Area Desuperheaters

Fisher and Whisper Disk Diffusers

Thermcraft Tube Furnace General Use

2 Sentry MCL Installation, Operation & Maintenance

What is pressure relief valve? Pressure relief valve

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Liquid Gas Cylinder (LGC)

Model Series 62 Constant Differential Relay

ASK HEROSE HEROSE NEWS NEW! EXCLUSIVE STOCK GENERANT SDC SERIES FOR DOT-4LC AND TC-4LM LIQUID CYLINDERS SILENT OPENING LCV & POP ACTION CRV CALL NOW!

MAINTENANCE & ASSEMBLY INSTRUCTIONS FUSIBLE LINK. Inline Thermal Check Valve

Operational Settings:

RELIEF VALVES. General Description

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

Spirax Compact FREME Flash Recovery Energy Management Equipment

MEGR-1912 Instruction Manual

Pressure reducing valves Index

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

Pressure Regulators. Operating Instructions. Instrumentation

Steam penetration in steam sterilization processes

CASH VALVE TYPE KP BACK PRESSURE VALVES

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Installation and Commissioning Instructions for GÄBLER-piston slide valves, especially for gaseous oxygen pipelines

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification

SRV461S and SRV463S Stainless Steel Direct Acting Pressure Reducing Valves

WORCESTER GREENSTORE. Indirect Unvented Cylinder with Solar Coil FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY GB/IE

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources

Pressure & Flame Protection

Tube rupture in a natural gas heater

Table of Contents - Protec Filters

indd indd

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

CS10-1 Stainless Steel Clean Steam Separator

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

MFP14-PPU (Vented) Automatic Packaged Pump Units

PRESSURE REDUCING VALVE RP45 (EN)

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

INSTALLATION AND OPERATION MANUAL CHEMICAL BYPASS FEEDER General Instructions Regarding All Models

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

6.6 Relief Devices. Introduction


Cryogenic Materials Operating Procedure and Safety Requirements

GREIG FILTERS, INC. OPERATION MANUAL

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

ASSIGNMENT 2 CHE 3473

Purge Star & Ring Purge Systems

ASSIGNMENT 2 CHE 3473

Right-Angle Tube Roller Model

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

TITAN FLOW CONTROL, INC.

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

PC3_ and PC4_ Pipeline Connectors

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

LGSS Liquefied Gas & VSS Vapor (Gas) LGSS VSS LGSS. Features and Benefits

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Safety Shut-off Valve SSV

TSS21 Sealed Thermostatic Steam Tracer Trap

PC10HP Pipeline Connector (ASME 600)

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Transcription:

GLAUNACH THE SILENCER HANDBOOK SILENCERS AN OVERVIEW OF OUR PRODUCT PORTFOLIO GLAUNACH GMBH 2010 - ALL RIGHTS RESERVED -

Part II page 2 of 10 ABSORBING SILENCER A any vent or blow-down application boiler start-up & purge 0 bar 0 psi 25 db depending on and number of absorber stages circular baffle silencer executed in stainless steel and mineral wool with long-stranded glass fabric lining, combined with an optimised radial diffuser inlet The gas flow is redirected and evenly distributed by the diffuser pipe, and the noise absorbed by the absorber baffles. Absorbing silencers can easily be extended with additional absorbers to achieve higher noise.

Part II page 3 of 10 DIFFUSER SILENCER D any vent or blow-down application boiler start-up & purge up to 50 db single- or multi-stage small-bore radial diffuser, surrounded by wrapped, finely woven stainless steel wire mesh In comparison to standard absorbing silencers, this technology provides comparable to better noise attenuation in a substantially smaller and lighter.

Part II page 4 of 10 DIFFUSER SILENCER WITH INSULATED SHELL DA any vent or blow-down application boiler start-up & purge up to 50 db D diffuser silencer, equipped with an additional longstranded glass fabric / mineral wool insulation of the inner shell surfaces The extra layer provides improved thermal and acoustic insulation of the outer shell.

Part II page 5 of 10 COMBINED SILENCER DIFFUSER / ABSORBER COMBINATION DAA any vent or blow-down application boiler start-up & purge 50 db integrated combination of a DA diffuser silencer with one or several A absorbing silencers stages The combination of a high-performance diffuser silencer with circular baffle absorber stages enables realising silencers for (almost) any noise requirement.

Part II page 6 of 10 INLINE DIFFUSER SILENCER INLINE closed systems requiring muffled in-line expansion of gaseous fluids under pressure without releasing them into the atmosphere, e.g. venting / blowing-down into a pipe or pressure vessel condenser injection up to 50 db specialised silencer for noise control in closed systems, based on a suitably modified D diffuser silencer The fluid is expanded through a multitude of small diffuser bores into a finely woven stainless steel wire mesh.

Part II page 7 of 10 DUMP TUBE DUMPTUBE gas expansion into low-pressure environments condenser injection controlled redirection and distribution of gas flows pressure control temperature control up to 35 db multi-stage dump tube expander with pecifically optimised number, size and arrangement of diffuser stages and diffuser holes, made from carbon steel or stainless steel available in customised s engineered by GLAUNACH, or according to customer specifications

Part II page 8 of 10 DIFFUSER DIFFUSER dump tube- requiring better noise attenuation, in particular gas expansion into atmospheric- / high-pressure environments condenser injection controlled redirection and distribution of gas flows pressure control temperature control up to 50 db multi-stage small-bore radial diffuser, surrounded by a pack of finely woven stainless steel wire mesh

Part II page 9 of 10 COLLECTING PIPE COLLECTING PIPE collection of gas flows from two or more pipes, including such with different gas pressures, e.g. for: connecting multiple inlets to a single vent silencer pressure matching up to 15 db without silencer application-specifically customised small-bore radial diffusers expand the gas flow(s) laterally into a common collecting pipe ed for the maximum possible flow The special minimises the mechanical load on the collecting pipe, improving operational life-time and safety. When used as outlet collector, the pipe diameter is ideally matched to the vent silencer. A collecting pipe permits expanding gases from lines with different set pressures to a common pressure; please observe that the permissible downstream idle pressure of the connected valves needs to be equated accordingly. 80 psi 40 psi 80 psi 145 psi

Part II page 10 of 10 RENTAL SILENCER s DA & DAA starting-up, bypassing, venting and blowing down of gases that (potentially) contain solid particles purging of (potentially) contaminated installations During equipment installation, component changes or repairs, solid materials - like debris or metal chipping - can be brought into the piping. These contaminations have to be removed before operating the installation with process gas / steam, usually by a purge blow. The problem is that contained solid particles get trapped in the silencer, rendering most devices ineffective or even dangerous to operate due to obstructions in the diffuser. up to 70 db DA or DAA diffuser silencer with exchangeable diffuser cartridge GLAUNACH s special rental silencers allow exchanging the diffuser cartridge as soon as its performance is impeded by debris, and the back pressure becomes too high. GLAUNACH rental silencers can thus be used repeatedly even in contaminated that would be an absolute no-go for other silencers.