Pilots Specifications

Similar documents
P r o d u c t R a n g e Data sheet: P

RAF Diaphragm Control Valves for Waterworks

Ø248 Ø Series. R 2.00 R 2 Hydraulic Control Valves R 3 R 6 SEE "SEAT DE T DETAIL NO. 2" CONTROL VALVES

The Future of Hydraulic Control in Water-Systems

SINGLE VALVE WITH LOW-FLOW BYPASS

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING

Installation and operation Manual. Bermad Surge Anticipation Valve. Model No 435

BERMAD Fire Protection Hydraulic Control Valves

Pressure Reducing Control Valve w/ Hydraulic Check Feature

300 Series. Automatic Hydraulic Control Valves

DN300 DN2000 C Plunger Valve

Model: 43T. Bermad Pressure Relief Valve

VALVES HIDROMATIC VALVE.

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

FILTER BYPASS CONTROL

Principle of Operation. Features. Applications. CL34 Operating Schematic

Rate of Flow Valve Series 120

my SYSTEM A guide to common applications in water distribution systems

WW-730. Pressure Sustaining/Relief Control Valve

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Waterous Relief Valve

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

BAKER CONTROL VALVES Member of the. group AVK SOUTHERN AFRICA THE ART OF FLOW CONTROL

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Bermad Pressure Reducing. Model: 42T

IWCF Equipment Sample Questions (Surface Stack)

CASH VALVE TYPE KP BACK PRESSURE VALVES

SINGER MODEL 106/206-RPS-L&H

BEFORE SALES AFTER SALES

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

INSTALLATION OPERATION MAINTENANCE

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

TECHNICAL DATA. Q = C v P S

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660

TECHNICAL DATA. Page 1 of 12

Actuator HON 670 / 671

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Digester Processes. 1. Raw Sludge Pumping System

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

TECHNICAL DATA. Q= Cv S

1800CPB2 Pilot-Loaded Service Regulators

Model 1800 PFM Series Regulator. Technical Bulletin

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Pilot HON 630a, HON 640

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

Time-Delay Electropneumatic Applications

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Water Pressure Reducing Valves

1800CPB2 Service Regulators

Discharge Relief Valve Operation & Maint.

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

SB AXIAL FLOW VALVES

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Lesson 6: Flow Control Valves

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

FAULT CODE TROUBLESHOOTING INDEX

Testing Procedures & Trouble Shooting Guide Reduced Pressure Zone Assembly (1/2, 3/4", 1, 1 1/4, 1 1/2" & 2 )

Pilot Operated Safety Relief Valves For Liquified Gas Carriers

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

Hydraulics. Hydraulic Pressure Control

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

TECHNICAL DATA. Q = C v P S

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

Directional Control valves

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Tightness control TC. Product brochure GB 3 Edition AGA

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

ASVAD THE SIMPLE ANSWER TO A SERIOUS PROBLEM. Automatic Safety Valve for Accumulator Depressurization. (p.p.)

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

TECHNICAL DATA CAUTION

WHEATLEY Series 500 Swing Check Valve

T e l N o : F a x N o : E m a i l : a i s h c m c - m e. c o m w w w. c m c - m e.

[You may download this article at: ]

ANTI SHOCK RELIEF VALVE

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

EDUCATION DEPARTMENT ACCU-TEST

The OCV Series 8000 float control valves are designed to maintain a SERIES FEATURES

1800C and 1800C-HC Service Regulators

STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

Date of Issue: July 2016 Affected Publication: API Specification 16C, Choke and Kill Equipment, Second Edition, March 2015 ADDENDUM 1

FUNDAMENTAL PRINCIPLES OF SELF-OPERATED PRESSURE REDUCING REGULATORS. John R. Anderson Emerson Process Management Fluid Controls Institute

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA. Dry 132a. October 1, 2008

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

TECHNICAL DATA. Q = C v P S

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

Combination Air Valve Model

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

Transcription:

ilots Specifications - -way ressure Reducing metal pilot. 7-0 SI (0.-6 bar) - -way ressure Sustaining metal pilot. 7-0 SI (0.-6 bar) - -way Quick Relief metal pilot. 7-0 SI (0.-6 bar) - Altitude metal pilot. 7-0 SI (0.-6 bar) - -way ressure Reducing/Sustaining plastic pilot. 7- SI (0.-0 bar) -D -way differential pressure plastic pilot. 7- SI (0.-0 bar) - - - - rincipal Operation -way ressure Reducing Sensing Sensing Sensing ort ressure Reducing Sensing / Downstream ent ontrol hamber ressure / Upstream ressure Sustaining Sensing / Upstream ressure / Upstream ontrol hamber ent ent ommon ommon ommon Upstream Upstream Upstream High pressure position Set point pressure position Low pressure position rincipal Operation -way ressure Reducing Upstream Sensing Sensing Upstream Upstream Sensing ort ressure Reducing Sensing / Downstream ressure / Upstream ontrol hamber ommon ommon ommon High pressure position Required pressure position Low pressure position OBox 880, Kiriat Malachi 808 Israel, Tel 97 8 86000, Fax 97 8 860006, E mail info@ooval.com, www.ooval.com

ressure Reducing alve Ooval reducing configurations for general water supply systems with medium pressure rating. The plastic pilot model is best for irrigation and low-pressure applications. The plastic materials and straightforward design provide high corrosion resistance and costeffective prices. The -way pilot configuration, together with the unique diaphragm, enables smooth and precise pressure control. Use Ooval valves for domestic, water works, and filtration networks. Ooval valves are piloted hydraulic valves activated by line pressure. The pilot valve has a spring-loaded diaphragm that is sensitive to downstream pressure. The pilot s spring is preset to the desired reduced pressure. The pilot valve maintains a constant downstream pressure by gradually opening and closing the Ooval valves at any flow rate. -way ressure Reducing alve for sizes -6 with pressure ratings up to SI (0 bars). -way ressure Reducing alve with pressure rating up to SI (6 bars). Adjustment Adjust the reduced pressure set point with the adjusting screw on the pilot. The Ooval ressure Reducing alve is activated by line pressure and controlled by the pilot valve. The pilot includes a spring-loaded diaphragm that is exposed to the downstream pressure. The displacement of the membrane due to downstream fluctuation defines the flow direction inside the pilot. When the downstream pressure is lower than desired, the valve is automatically directed to open. In the reverse case, it is automatically directed to close. When line pressure is inserted into the control chamber of the valve (above its diaphragm) the valve closes. When the control chamber drains, the valve opens as a result of the line pressure from below its diaphragm. In two-way configurations, the control chamber drains downstream, enabling faster reaction time and gradual opening without water discharge. ontrol Mode -way lastic ilot Manual: Use the three-way selector to close or open the valve by turning the handle to (closed) or O (open) positions. Automatic: osition the three-way selector handle to A (automatic). When the downstream pressure is lower than that of the pilot spring, the valves control chamber drains via ports and of the pilot to open the valve. When the downstream pressure is too high, the pilot diaphragm moves upward allowing ports and to connect, thus permitting line pressure to close the valve. In three-way configurations, the control chamber drains out to atmosphere, permitting the valve to open entirely. ontrol Mode -way ilot Manual: To open the Ooval, open isolation valves and. To close the Ooval, close the downstream isolation valve. Automatic: When the downstream pressure is lower than that of the pilot spring, the control chamber drains downstream and the valve opens. In this case, there is a connection between the port (inlet upstream), the port (outlet downstream) and the control chamber. When the downstream pressure rises above the preset spring load, the pilot s diaphragm is forced upward, closing port or. The valve then begins closing and downstream pressure decreases. OBox 880, Kiriat Malachi 808 Israel, Tel 97 8 86000, Fax 97 8 860006, E mail info@ooval.com, www.ooval.com

ressure Sustaining / Relief alve Use the pressure sustaining/relief valve to maintain constant upstream pressure and to avoid undesirable high-pressure situations. This protection is required for most irrigation systems, domestic and industrial utilities, and for general water supply systems. The -way plastic pilot model provides high resistance to corrosion at a cost effective price. It is best for irrigation, filtration manifolds, water treatment circulation and low-pressure domestic applications. The -way pilot command provides smooth and precise pressure control. The pilot valve has a spring-loaded diaphragm that is exposed to upstream pressure. The valve is normally closed. With ressure Relief alves, only when the line pressure rises above a preset point does the valve open to reduce the excessive upstream pressure. The excess pressure is released off-line. ressure Sustaining alves reduce the excessive downstream pressure without causing surge hazards. When the line pressure drops beneath the desired point, the valve closes. -way plastic piloted pressure sustaining/relief valve for sizes -6 with pressure rating up to SI (0 bars). -way ressure Sustaining/Relief alve with pressure rating up to SI (6 bars). Adjustment Adjust the sustained pressure with the adjustment screw on the pilot. The ressure Sustaining/ Relief alve is activated by the line pressure and controlled by a pilot valve. A sustained pressure is preset by adjusting the pilot retaining spring. The pilot is connected to line pressure (upstream). The displacement of the pilot s spring-loaded diaphragm due to upstream pressure defines the flow direction inside the pilot. When the upstream pressure is higher than the set point, the valve is piloted to open. Otherwise the valve remains closed, maintaining the upstream pressure. The excess line pressure is relieved downstream. In -way pilot configurations, the valve control chamber drains out, enabling the valve to open fully. In - way pilot configurations, the control chamber drains downstream, enabling faster reaction time and gradual closure without water discharge. ontrol Mode -way lastic ilot Manual: Use the three-way selector to close or open the valve by turning the handle to (closed) or O (open) positions. Automatic: osition the three-way selector handle to A (automatic). When the upstream pressure is low, the pilot s membrane is in its lowest position. The valve s control chamber is exposed to line pressure through ports - of the pilot. The valve closes to sustain the upstream pressure. When the upstream pressure is higher than preset, the pressure overcomes the pilot s spring and forces the pilot s diaphragm to move upward. The connection between ports - opens and port closes. The control chamber drains and the valve opens to relieve the excessive pressure downstream. In -way configurations, the control chamber drains out to atmosphere, permitting the valve to open entirely. ontrol Mode -way ilot Manual: To open the valve, open isolation valves and. To close the valve, close the downstream isolation valve. The upstream isolation valve should remain open. Automatic: When the upstream pressure is lower than that of the sustained pressure set point, the valve s control chamber is connected to the line. This connection occurs through ports (inlet upstream) and port. The valve closes until the desired upstream pressure is achieved. When the upstream pressure rises above the set point, the pilot s diaphragm is forced upward. ort (outlet downstream) opens and the control chamber of the Ooval drains downstream, alleviating the excess pressure. 6 OBox 880, Kiriat Malachi 808 Israel, Tel 97 8 86000, Fax 97 8 860006, E mail info@ooval.com, www.ooval.com

ressure Reducing/Sustaining alve Use the pressure reducing/sustaining valve to define two pressure zones along a supply line. Typically, this occurs along a downhill flow. ressure Reducing/Sustaining valves are piloted hydraulic valves activated by line pressure and controlled by pilots. Both pilots have spring-loaded diaphragms. One pilot is responsive to upstream pressure and the other to downstream pressure. The combined operation of the two pilot valves sustains the preset minimum upstream pressure of the valve, and at the same time, reduces the downstream pressure to a preset maximum pressure. The valve opens or closes gradually to maintain both required pressures simultaneously. -way plastic piloted ressure Reducing/Sustaining valve. lastic pilot is used for -6 sizes with pressure rating up to SI (0 bar). -way pressure Reducing/Sustaining valve with pressure rating up to SI (6 bars). Adjustment Adjust the pressure set points with the adjusting screws on the pilots. S R S R The ressure Reducing/Sustaining valve is activated by the line pressure and controlled by two pilot valves. Both pilots include spring-loaded diaphragms. The sustaining pilot is preset to sustain the upstream pressure at a preset point. The reducing pilot reduces the downstream pressure and maintains it at a lower preset level. Under normal flow conditions, the valve is partly open to sustain the upstream pressure and reduce the downstream pressure. It partly closes when the downstream pressure rises above the lower set point or when the line pressure drops below the upper set point. It opens again when the upstream pressure rises. In -way pilot configurations, the control chamber of the valve drains out to atmosphere, enabling the valve to fully open. In -way pilot configurations the control chamber drains downstream, enabling faster reaction time and gradual opening without water discharge. ontrol Mode -way lastic ilot Manual: Use the three-way selector to close or open the valve by turning the handle to (closed) or O (open) positions. Automatic: osition the three-way selector handle to A (automatic). When the upstream pressure is low, the line pressure flows through ports - of the sustaining pilot and flows into the valve s control chamber. The valve closes to sustain upstream pressure. When the upstream pressure reaches the set point, the diaphragm of the reducing pilot moves upward and connects ports -. The control chamber drains through the sustaining pilot and exits port of the reducing pilot. The valve then opens to the preset downstream pressure. When the downstream pressure is greater then the desired level, the reducing pilot s diaphragm moves up, allowing water to flow into the control chamber through ports - of the sustaining pilot. ontrol Mode -way ilot Manual: To open the valve, open isolation valves and. To close the alve close the downstream isolation valve. The upstream isolation valve should remain open. Automatic: When the upstream pressure is low, the control chamber is connected through the -way sustaining pilot to the line pressure and the valve closes. When the line pressure rises and overcomes the spring of the sustaining pilot, the pilot s membrane moves upward to open port (outlet downstream). The control chamber then drains downstream through the -way reducing pilot. The valve then opens and reduces the upstream pressure. As the line pressure is reduced, the sustaining pilot closes, as does the valve. If the downstream pressure is greater than the set point of the reducing pilot, the reducing pilot s membrane moves upward and closes port (outlet downstream). The control chamber is connected to the upstream pressure and the valve closes. OBox 880, Kiriat Malachi 808 Israel, Tel 97 8 86000, Fax 97 8 860006, E mail info@ooval.com, www.ooval.com 7

Quick ressure Relief alve A Quick ressure Relief alve (QR) protects water systems from rapidly increasing excess pressure. It is recommended to install the Ooval QR valve at the start of the system near the main supply line or booster pump. The ressure Relief alve is a piloted hydraulic valve activated by line pressure. The -way pilot has a spring-loaded diaphragm that is sensitive to upstream pressure. The valve is normally closed. As the line pressure rises above the preset level, the valve opens quickly to relieve the excess pressure. The valve is a general application -way piloted ressure Relief alve with a pressure rating up to SI (6 bars). The ressure Relief alve is activated by line pressure. The displacement of the diaphragm in the pilot is due to a rise in line pressure against the spring force. As the pressure increases above the set point, the water flow inside the pilot is directed so that the valve quickly opens. ontrol Mode Automatic: When the line pressure is low, the sustaining pilot and the valve are closed by line pressure. The valve remains closed until the line pressure is higher than the set point of the pilot. As pressure increases above the set point, the diaphragm moves upward under the line pressure and port (outlet downstream) of the pilot opens, allowing the control chamber to drain through the vent. The Ooval opens in a few seconds relieving the excess pressure. 8 OBox 880, Kiriat Malachi 808 Israel, Tel 97 8 86000, Fax 97 8 860006, E mail info@ooval.com, www.ooval.com

Electric ontrol Hydraulic alve On/Off electric valves are used for remote control of hydraulic valves. Normally open or normally closed configurations are available. The valve opens or closes by electric command through a selection of either -way or -way solenoid valves. The solenoid opens or closes the valve when energized by an electric signal. The electric signal originates with a controller, timer, sensor or remote control device. Three-way normally closed and -way normally open electric control valve. Two-way normally closed and -way normally open electric control valve. -way configuration: The valves control chamber drains downstream, enabling faster and gradual opening without water discharge. -way configuration: The valve control chamber drains to atmosphere, allowing the valve to open fully. ontrol Mode Normally losed Mode: The line pressure is connected to the Ooval s control chamber above its diaphragm via port (pressure) and port (common). The diaphragm is pressed downward against the valve seat closing the valve. As an electric signal energizes the normally open (NO) solenoid, its plunger changes position and the control chamber drains out through port (vent). The diaphragm is forced upward by the line pressure and the valve fully opens. Normally Open Mode: The valve s control chamber is connected to port (common) of the solenoid. The valve s diaphragm is pressed upward by line pressure keeping the valve in the open position. As the normally closed (N) solenoid is energized by an electric signal, its plunger changes position and the vent closes. The control chamber of the valve becomes connected to the pressure source via port (pressure) and port and the valve closes. = ommon = ressure = ent Energized Energized N.O. Solenoid N.. Solenoid De - energized De - energized OBox 880, Kiriat Malachi 808 Israel, Tel 97 8 86000, Fax 97 8 860006, E mail info@ooval.com, www.ooval.com 9

Hydraulic Remote ontrol alve Use valve with a hydraulic remote control in those situations where the command pressure is lower or higher then the working pressure or in situations where there are topographic differences between the command source and the line water pressure at the valve. The hydraulic remote control is also used where the use of wires is not feasible. On/Off hydraulic remote control valves are used for the remote control of hydraulic valves. In normally closed (N) configurations, the valve remains closed until the hydraulic relay receives a hydraulic command. In the normally open (NO) model, the valve is open until the hydraulic relay receives a hydraulic command to close. Normally open and normally closed configurations are available. Operating pressure is up to SI (0 bars). A pressure regulating or pressure sustaining pilot may be used in conjunction with the hydraulic relay. The valve is activated by line pressure and controlled by the hydraulic relay. The relay includes a springloaded diaphragm that determines the pressure required to activate the command. In the normally closed operation (N), the line pressure is connected to the valves control chamber keeping the valve closed. In the reverse case (NO), the valve remains in the open position. ontrol Mode Normally losed Mode: In normally closed applications, when the command is received by way of port, the line pressure port is prevented from entering the control chamber through the connection between port - and the water in the control chamber drains through port, causing the valve to open. Normally Open Mode: In normally open applications, port connects to the upstream line pressure and water is prevented from entering the bonnet. When the command is received by way of port, port connects to port and the valve closes. Basic alve Basic valve can be operated manually through the use of a -way selector. Selector options are: losed: Upstream pressure or pressure from an external source is applied to the control chamber. The diaphragm is pressed down to close the valve drip-tight. Open: Discharging the water or air pressure to the atmosphere from the control chamber causes the valve to open. Automatic: The automatic port of the -way selector is connected to a solenoid, hydraulic relay or pilot, which controls the valve. The common port of the -way selector connects the control chamber to either A (automatic), O (open) or (closed), depending on the direction the selector is pointed. Way lastic Relay N.O. lose Mode Open Mode N.. 0 OBox 880, Kiriat Malachi 808 Israel, Tel 97 8 86000, Fax 97 8 860006, E mail info@ooval.com, www.ooval.com