ASBESTOS INSPECTION PLANT BIOLOGY BUILDING 178 MICHIGAN STATE UNIVERSITY

Similar documents
THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

THREE-YEAR RE-INSPECTION and ASBESTOS MANAGEMENT PLAN for the

FINAL Designated Substances Survey Report Women s Residence 674 Dundas Street West, Toronto, Ontario

ASBESTOS INVENTORY CONTROL

Asbestos Regulation and Compliance

WITTICH HALL RENOVATION

WAYNE COUNTY BOARD OF EDUCATION. Asbestos Operations and Maintenance Program

OPERATIONAL GUIDELINE P R O C E D U R E

ASBESTOS OPERATIONS AND MAINTENANCE SAFETY PROGRAM

Safe Work Practices / Procedures / Instruction ASBESTOS. (See also Asbestos Exposure Control Plan )

Sept 23, 2014 LAB MANUAL

THE EAGLE CREEK PLAN BN-1B W/BASEMENT

Chapter 7 Inspector Safety

APPENDIX P U.S. EPA WARM MODEL OUTPUT

Estates & Facilities Management - Management and Control of Asbestos Policy and Procedures

INSTALLATION & OPERATION MANUAL AORCS ATLAS OPERATING ROOM CEILING SYSTEM. Redefine your comfort zone.

BEGINNING THE MEETING

CONTRACTOR HEALTH, SAFETY AND ENVIRONMENTAL HANDBOOK

Net Receipts by County

Specifications For Threaded and Butt Weld Hammer Unions

User Information Sheet 015

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO CSAH 133 OVER A DITCH ST. LOUIS COUNTY

Cooling NI Single-Board RIO Systems Appendix: Reference Examples NI sbrio-9605/6

CYCLIC PERFORMANCE PER ASTM E 330 TEST REPORT. Rendered to: TRUSEAL TECHNOLOGIES, LTD. PRODUCT TYPE: Fixed Window

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A STRUCTURAL PERFORMANCE TEST REPORT SUMMARY RENDERED TO:

Metal Expansion Joints. System solutions for reliable connections in plant engineering and construction.

TERMITE PROTECTION Material Description Qty Units Cost M/up Labor Total. Termite Control (Slab) 188 m Subtotal

4 Testing Agency Guide. 4.1 U.S. Army Corps of Engineers (USACE) Standard for Air Leakage

Asbestos Operations and Maintenance Plan

UPDATE ARLINGTON COUNTY. Bicycle Parking Standards

Seamless Acoustical Plaster Solutions

ACCREDITATION OF ON-LINE LEAK SEAL ORGANIZATIONS

Electrical Tapes Selection Guide. 3Innovation

CCR Fugitive Dust Control Plan

Safe Work Practices for Handling Asbestos DRAFT

2. MIXING SHAW 5050 is ready to use. No mixing is required. Simply open the container and spread.

Pressure Relief Device Investigation Testing Lessons Learned

Air Leakage Detailing & Awareness Services

17374 US ROUTE 694 OTTAWA, OHIO 45875

TATTVAM ENVIRONMENTAL AND ENGINEERING SOLUTIONS, LLC. Indoor Air Quality Report for Weston Public Schools Weston, CT.

WILL NOT DISTURB ASBESTOS CONTAINING MATERIAL!

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

Gas Cylinder Cabinets

Township of North Huntingdon Application for Permit

IRB Regulation 22 Performance Specification Re-test Field Report

Appendix 2-B: Paint Testing Summary Table

Commercial Pool Legislation (M39)

Indian River County Impact Fee Update Study. FINAL REPORT Executive Summary

1. Main Tees: Product: Donn T38 FR QRC Main Tee. Main tees shall be spaced at 1200mm centres.

Standard Pneumatic Test Procedure Requirements for Piping Systems

LATICRETE International Inc. One LATICRETE Park North Bethany, CT USA

Class 1 (Explosive) Hazmat: The Hazardous Materials Table. Hazard Classifications Used in Hazmat Table, Column 3

TO THE DRAWINGS AND THE PROJECT MANUAL

Bomb Blast Mitigation Test

PROPOSED CONVERSION OF MYRTLE BEACH MIDDLE SCHOOL TO MYRTLE BEACH ELEMENTARY SCHOOL PMH. PIKE McFARLAND HALL ASSOCIATES, INC. ARCHITECTS & PLANNERS

PERFORMANCE TEST REPORT FOR AIR LEAKAGE AND DURABILITY OF BARRIER PRODUCTS ASTM E Rendered to: BAUTEX SYSTEMS

Facility Condition Assessment Report

New Asbestos Analyst Guide

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (ELEVENTH REVISION)

Pool Inspection. Your Street San Diego, California Prepared for: Your Name Prepared by: Priority Inspection Service

Commercial Pool Legislation

Control of Work. Introduction This procedure describes the management of Asbestos. Definitions

Building Services Department

Packaging Information Bulk Packs Non-Gas

VWP CONSTRUCTION INSPECTION REPORT. Project Name: Berkmar Drive Extension Locality: Albemarle County Inspector: ERM

CCR Certification: Fugitive Dust Control Plan (b) for the. West Ash Pond. at the. F. B. Culley Generating Station.

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

WP2 Fire test for toxicity of fire effluents

New Licensed Asbestos Operative Training

For optimal strength and durability, we use a co-extrusion process of 3 different PVCs in the manufacturing of our pool cover slats.

Facility Condition Assessment Report

ROTHERHITHE BATH AND ASSEMBLY HALL OFFICIAL OPENING 27 NOVEMBER 1965

ICC REGULATIONS FOR THE REVIEW OF BOWLERS REPORTED WITH SUSPECT ILLEGAL BOWLING ACTIONS

Built for Champions: Mattamy National Cycling Centre Takes Off

MSA Cairns FIRE HELMET PRODUCT SPECIFICATION. PURPOSE: To supply a uniform, standard product specification for a leather structural fire helmet.

NAVSEA STANDARD ITEM. 1.1 Title: Contractor Crane, Multi-Purpose Machine and Material Handling Equipment at a Naval Facility; provide

ASTM E1886 and ASTM E1996 TEST REPORT. Report No.: E Rendered to: 3M COMPANY St. Paul, Minnesota 55144

1. Scope: This document describes the procedure for verifying the performance of vaccine vial monitors.

FENCE RENTAL, PURCHASE, INSTALLATION, SUPPLIES & SERVICE - REQUIREMENTS CONTRACT INVITATION FOR BID PRICE SHEET ATTACHMENT E

Two Rivers Activity Center (TRAC) McGough Construction 2737 Fairview Avenue North St. Paul, MN Phone: (651)

REQUEST FOR PROPOSAL FOR WATERPROOFING STRUCTURAL ENGINEERING

ARTIFICIAL GRASS PITCH INTRODUCTORY GUIDE

Ottawa Beach Road Study

F-08 HIGH-PRESSURE HOSE USED IN CO2 SYSTEM

HAZARD ASSESSMENT FOR ORANGE COUNTY SCHOOLS

Transcription:

Asbestos Inspection Plant Biology Building 178 Michigan State University Prepared For: Michigan State University January 2008 Project No. G07876PB

ASBESTOS INSPECTION PLANT BIOLOGY BUILDING 178 MICHIGAN STATE UNIVERSITY PREPARED FOR: MICHIGAN STATE UNIVERSITY JANUARY 11, 2008 PROJECT NO. G07876PB Fishbeck, Thompson, Carr & Huber, Inc. Engineers Scientists Architects Constructors 1515 Arboretum Drive, SE, Grand Rapids, MI 49546 Telephone: 616-575-3824

TABLE OF CONTENTS INTRODUCTION...1 CERTIFICATION...2 INSPECTION PROCEDURES AND SAMPLING METHODOLOGY...2 RESULTS...2 CONCLUSIONS...3 LIST OF FIGURES Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Plant Biology Building 178 - South Wing Basement Level Plant Biology Building 178 - West Wing Basement Level Plant Biology Building 178 - East Wing Basement Level Plant Biology Building 178 - Center Section Basement Level Plant Biology Building 178 - Center Section First Floor Plant Biology Building 178 - East Wing First Floor Plant Biology Building 178 - South Wing First Floor Plant Biology Building 178 - South Wing Second Floor Plant Biology Building 178 - East Wing Second Floor Plant Biology Building 178 - Center Section Second Floor Plant Biology Building 178 - Center Section Third Floor Plant Biology Building 178 - South Wing Third Floor LIST OF TABLES Table 1 Table 2 Table 3 Description of Homogeneous Materials Bulk Sample Location Log Summary of Asbestos-Containing Homogeneous Materials LIST OF APPENDICES Appendix 1 Appendix 2 Appendix 3 Photograph Log Analytical Reports Room-By-Room Building Inspection Summaries LIST OF ABBREVIATIONS/ACRONYMS ACM CFR FTC&H HA l.f. MM s.f. SM TSI MSU asbestos-containing material Code of Federal Regulations Fishbeck, Thompson, Carr & Huber, Inc. homogeneous area linear feet miscellaneous material square feet surfacing material Thermal System Insulation Michigan State University J:\07876PB\REPT\ASB_2008_0111.DOC i

INTRODUCTION FTC&H was retained by MSU to conduct an inspection of Plant Biology Building 178 for ACMs. Based on the information that was provided to FTC&H, the facility was constructed in 1966 with one addition (South Wing) in 1985. The building has three floors, which comprise a total of 172,000 s.f. The inspection was conducted according to the protocol described in 40 CFR 763 Subpart E with the following exceptions: Damage assessments were limited to significantly damaged accessible materials. No significantly damaged materials were observed. Sample locations for surfacing materials (e.g., plaster, drywall joint compound, etc.) were limited to discrete accessible locations where damage could be minimized. The inspection did not include building materials on the exterior of the building, destructive sampling, inaccessible equipment, fiberglass, steel, concrete/mortar/block, ceramic tile, or inaccessible areas/materials. The following materials were assumed to contain asbestos: Fire doors Laboratory counter tops High voltage electrical wire wrap TSI in metal jacketing Transite wall panels Plaster 1985 Addition The following rooms were inaccessible at the time of the inspection: Room 1 Room 3 Room 33 Room 35 Room 38 Room 65 Room S-12A Room S-6 J:\07876PB\REPT\ASB_2008_0111.DOC 1

Room 136A Custodial Closet First floor east wing Room S-112B Room 261 Room 254 Room 308 The inspection was conducted from November 5 through November 8, 2007, and on November 12, 2007, in accordance with the FTC&H proposal dated August 10, 2007. CERTIFICATION The building inspection was lead by a State of Michigan accredited Asbestos Building Inspector, Mr. Mark A. Lutkenhoff (Accreditation No. A12430). All samples were sent to an independent laboratory for analyses. Laboratories used for the analyses are identified in Appendix 2, as shown on the analytical reports. INSPECTION PROCEDURES AND SAMPLING METHODOLOGY The inspection was conducted in a room-by-room fashion. According to the standard, all materials were considered suspect ACMs for sampling purposes. For the purposes of this report, the terms homogeneous area and homogeneous material are used interchangeably. Homogeneous material numbers were arbitrarily selected depending on when they were first identified. The number of samples collected from each homogeneous material was determined depending on the type of material, and at least one sample was collected from miscellaneous materials. Sample locations were randomly selected by the inspector at the time of the inspection. Sample locations are shown on Figures 1 through 12. RESULTS A total of 53 unique homogeneous materials were identified during the inspection of Plant Biology Building 178, resulting in 68 samples collected and 111 sample analyses (including layers). As a result, 5 homogeneous materials were assumed to contain asbestos and 5 homogeneous materials were tested and found to be asbestos containing (having a concentration greater than 1% by weight). The results of the building inspection are provided in Tables 1 through 3, and Appendix 3. Table 1 identifies the homogeneous materials and their corresponding identification number. Photographs of each homogeneous material are included in Appendix 1. Table 2 identifies each distinct sample number and the sample locations. Summaries of the asbestos-containing and non asbestos-containing homogeneous J:\07876PB\REPT\ASB_2008_0111.DOC 2

materials identified in each room (functional space) and approximate quantities are presented in Appendix 3. Functional spaces which were identical in size and homogeneous materials were grouped together with the total quantity of each homogeneous material reported. Table 3 summarizes the assumed or confirmed ACMs with an approximate quantity. HOMOGENEOUS AREAS 14, 15, AND 17 Homogeneous areas 14, 15, and 17 were observed in room 20 of the building. These materials were removed prior to the completion of the inspection as part of a renovation project. Therefore, no pictures were taken, and no verification sampling of these materials was conducted. CONCLUSIONS From November 5 through November 8, 2007, and on November 12, 2007, FTC&H conducted an inspection of Plant Biology Building 178 on the campus of MSU. A total of 53 unique homogeneous materials were identified during the inspection, resulting in 68 samples collected and 111 sample analyses (including layers). Five homogeneous materials were assumed to be asbestos and 5 were tested and found to be asbestos containing (having a concentration greater than 1% by weight). J:\07876PB\REPT\ASB_2008_0111.DOC 3

Table 1 - Description of Homogenous Materials Michigan State University - Plant Biology Building 178 Inspection Dates: November 5 through November 8, 2007 Page 1 of 1 HA Number Material Type Unit Asbestos? Material Description 1 Drywall & drywall joint compound MM s.f. No 2 Fittings on fiberglass insulated piping TSI l.f. Yes 3 12" VAT- White with grey and black streaks MM s.f. No 4 Black covebase MM s.f. No 5 Laboratory counter tops MM s.f. Assumed 6 Fire Doors MM ea. Assumed 7 Expansion gaskets MM s.f. No 8 2' x 4' suspended ceiling tile- white with various size fissures and pinholes MM s.f. No 9 9" VAT- Light brown with white and dark brown streaks MM s.f. Yes 10 2' x 4' suspended ceiling tile- white with long fissures and random pinholes MM s.f. No 11 Brown covebase MM s.f. No 12 2' x 2' suspended ceiling tile- white with random fissures and pinholes MM s.f. No 13 Yellow carpet mastic MM s.f. No 14 12" VAT- beige with brown streaks MM s.f. No 15 12" VAT- tope with off white and brown streaks MM s.f. Yes 16 2' x 2' suspended ceiling tile- white with long fissures MM s.f. No 17 Sheet vinyl- tope with grey and white streaks MM s.f. Yes 18 Plaster SM s.f. No 19 12" VAT- Light blue with dark blue and white streaks MM s.f. No 20 12" VAT- Brown with black and white streaks MM s.f. No 21 High voltage wire wrap MM s.f. Assumed 22 2' x 4' suspended ceiling tile- white with random pinholes MM s.f. No 23 Sheet vinyl- yellow with irregular white shapes MM s.f. Yes 24 12" VAT- White with light blue streaks MM s.f. No 25 2' x 2' suspended ceiling tile- white with fissures and pinholes MM s.f. No 26 Mag pipe insulation TSI l.f. Yes 27 Red covebase MM s.f. No 28 2' x 2' suspended ceiling tile- white with random pinholes (1985 Addition) MM s.f. No 29 Light brown covebase (1985 Addition) MM s.f. No 30 12" VAT- brown with white and brown streaks (1985 Addition) MM s.f. No 31 12" VAT- cream with white streaks MM s.f. No 32 Dark brown covebase (1985 Addition) MM s.f. No 33 Black covebase (1985 Addition) MM s.f. No 34 Drywall & drywall joint compound (1985 Addition) MM s.f. No 35 12" VAT- Peach with brown and white streaks (1985 Addition) MM s.f. No 36 Plaster (1985 Addition) SM s.f. Assumed 37 2' x 2' suspended ceiling tile- white with fissures and pinholes (1985 Addition) MM s.f. No 38 2' x 2' suspended ceiling tile- white with small random fissures and pinholes MM s.f. No 39 Blue covebase MM s.f. No 40 Grey covebase MM s.f. No 41 2'x4' suspended ceiling tile- white with fissures and pinholes MM s.f. No 42 12" VAT- Light brown with dark brown and white streaks MM s.f. No 43 Transite wall panels MM s.f. Assumed 44 12" VAT- beige with dark and light brown streaks MM s.f. No 45 12" VAT- beige with multi-colored streaks (1985 Addition) MM s.f. No 46 Void N/A N/A 47 Red with brown covebase (1985 Addition) MM s.f. No 48 12" VAT- Grey with white and dark grey streaks MM s.f. No 49 2' x 4' suspended ceiling tile- white with random pinholes x 2 MM s.f. No 50 12" VAT- beige with dark brown and white MM s.f. No 51 12" VAT- Pink with black and grey (1985 Addition) MM s.f. No 52 12" VAT- chocolate brown with white streaks MM s.f. No 53 Sheet vinyl- green with multi-colors MM s.f. No Notes: MM SM TSI s.f. l.f. ea. HA VAT Miscellaneous Material Surfacing Material Thermal System Insulation Square Feet Linear Feet Each homogenous area vinyl asbestos tile J:\07876PB\REPT\ASB_2007_0111Tables.xls 1/10/2008