tel: fax: web:

Similar documents
OPERATING INSTRUCTIONS

VACUUM REGULATORS CONTENTS

DURHAM GEO SLOPE INDICATOR

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

OPERATING INSTRUCTIONS

Durham Geo-Slope Indicator S-510 Triaxial Cell

Precision and Instrument Regulators 1/4" port size

Florida Method of Test for MEASUREMENT OF WATER PERMEABILITY OF COMPACTED ASPHALT PAVING MIXTURES

TEST FOR STABILOMETER VALUE OF BITUMINOUS MIXTURES

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Laboratory Flowmeters

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

PRO-50 Instrument Supply Regulator

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

Standard Test Method for Capillary-Moisture Relationships for Fine-Textured Soils by Pressure-Membrane Apparatus 1

Schroeder Check Test Point System

Description Advanced Features Typical Applications

Standard Test Method for Infiltration Rate of Soils in Field Using Double-Ring Infiltrometer 1

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

HORIZONTAL BLADDER TANK

Standard Grout Header. Protected Pressure Gauge. High Pressure Gauge. In-Line Grout Header. Inline Protected Pressure Gauge

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

Series IRV1000/2000/3000

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Air Operated Hydraulic Pumping Systems to 50,000 psi

VERTICAL BLADDER TANK

The number of test stands can be adapted to the special requirements.

PMI Advanced Automated. Pulse Decay Permeameter APDP-10K-HP-101. Not just products... Solutions!

SG3 Series Regulators - Pressure Reducing

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

SG1 Series Regulators - Pressure Reducing

DETERMINING OPTIMUM RESIDUAL ASPHALT CONTENT (RAC) FOR POLYMER-MODIFIED SLURRY SEAL (MICROSURFACING) MIXTURES

High Precision Gauge Pressure Indicators

AUTOMATIC HOSE TEST UNIT, TYPE SPU

TURBINE SEAL: AXIAL TYPE DESIGN

5k Slickline Lightweight Pressure Control Equipment 4 ID

Basic & Controlled Atmosphere Glove Boxes

4400 TwinHybrid Gas Seal

CAST IRON VALVES FLOAT VALVE

Tex-616-J, Construction Fabrics

HTHP Filter Press for Ceramic Disks with 175-mL, Double-Capped Test Cell and CO 2 # : (115 V) # : (230 V) Instruction Manual

Powers Controls D Day-Night Thermostats

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

SANDBLAST HELMET EXTREME

HighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Oxidation Stability of Gasoline and Aviation Fuels

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Tex-414-A, Air Content of Freshly Mixed Concrete by the Volumetric Method

Vibration isolated tables. Individually tailored to your requirements.

Instruction Manual Updated 5/26/2009 Ver. 2.0

PTC INSTRUMENTS 2301 Federal Ave Los Angeles CA Phone: Model 500 Automatic Operating Stand Type 3

Flow Sensors & Hydrometers Specification Sheet

Pocket Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

Tex-416-A, Air Content of Freshly-Mixed Concrete by the Pressure Method

Compatible with a Wide Range of Gases or Liquids for Laboratory or Plant Applications

Chlorinator. MODEL C-731 (Floor Mounted)

Choosing the right miniature instrument and control valve is a snap

AIR CONTENT OF FRESHLY MIXED CONCRETE BY THE PRESSURE METHOD (Kansas Test Method KT-18)

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Series 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position

B84G - Excelon Plus Modular System General purpose filter/regulator

829S1 Series Flexflo Pilot

ELE INTERNATIONAL COMPRESSION TESTER Standard Operating Procedure

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

[Instruments for vacuum measurement, checking and adjustment] 3

HCMTCB MATERIALS SAMPLING & TESTING PERFORMANCE CHECKLIST

ABRASIVE REGULATOR II

ACCU-PULSE I Pulsation Dampeners

Dewatering Landfill Gas Wells to Maximize LFG Collection

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

Expert Hydrostatic Level Transmitters

Capillary Flow Porometer/Frazier/C-522 CFP-1100AEX-F-C522

HCMTCB ASPHALT CERTIFICATION KEY ELEMENTS LIST

OP CHECKLIST FOR 1D CONSOLIDATION LABORATORY TEST

ABRASIVE REGULATOR II

Operating Instructions

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL


The X-11 Molding Chamber

Series K Air service units G 1/8, G 1/4

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

SG2 Series Regulators - Pressure Reducing

Pressure Sensing Valve - Model 4023

ADAPTABILITY & PRECISION

Freeze-Thaw Effects and Gas Permeability of Utility Line Backfill

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

Hydraulic Punch Drivers

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

SERIES 20 CHAMBERS THE RC-25 AND RC-25F CHAMBERS ASSEMBLY

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860

Variable Area Flow Meters

On-Off Connector Skirt

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

GROUTEC SCOTT VICKERS. Grouting Equipment

Transcription:

Tri-Flex 2 Five-Cell Permeability Test System For high volume commercial laboratory testing, the Tri-Flex 2 Five-Cell Permeability Test System offers the user the capabilities to test up to five samples at a time, each with its own individual pressure settings. Set includes: 1 Tri-Flex 2 Master Control Panel (25-0696/0x or 25-0697/0x). 2 Tri-Flex 2 Auxiliary Control Panel (25-0699). 1 Tri-Flex 2 Water De-airing Tank System (25-0698). 5 Tri-Flex 2 Permeability Test Cell (25-0690). 5 2.8" or 70 mm Acrylic Cap and Base Set (25-0690/15 or 25-0690/10). 5 2.8" or 70 mm Porous Stones, pack of 2 (25-6721 or 25-6561). 5 2.8" or 70 mm Membrane Sealing Rings, pack of 10 (25-6641 or 25-6461). 5 2.8" (70 mm) Membranes, pack of 10 (25-6441). 1 2.8" (70 mm) O-ring Placing Tool (25-6470). 1 2.8" (70 mm) Membrane Tester (25-6443). 1 2.8" or 70 mm Suction Membrane Device (25-6660 or 25-6480). EI25-0688/02. 110vAC, 50/60 Hz, 1ø, English. EI25-0688/01. 220vAC, 50/60 Hz, 1ø, English. EI25-0689/02. 110vAC, 50/60 Hz, 1ø, Metric. EI25-0689/01. 220vAC, 50/60 Hz, 1ø, Metric. For test applications involving toxic permeants, stainless steel Cap and Base Sets and two Pressure Interface Chambers are required for each test cell. Tri-Flex 2 Three-Cell Permeability Test System Similar to the five-cell system, the Tri-Flex 2 Three-Cell Permeability Test System includes three additional test cells and our Tri-Flex 2 Auxiliary Control Panel. Using this configuration, users can test up to three samples at a time, each with its own individual pressure settings. Set includes: 1 Tri-Flex 2 Master Control Panel (25-0696/0x or 25-0697/0x). 1 Tri-Flex 2 Auxiliary Control Panel (25-0699). 1 Tri-Flex 2 Water De-airing Tank System (25-0698). 3 Tri-Flex 2 Permeability Test Cell (25-0690). 3 2.8" or 70 mm Acrylic Cap and Base Set 3 (25-0690/15 or 25-0690/10). 3 2.8" or 70 mm Porous Stones, pack of (25-6721 or 25-6561). 3 2.8" or 70 mm Membrane Sealing Rings, pack of 10 (25-6641 or 25-6461). 3 2.8" (70 mm) Membranes, pack of 10 (25-6441). 1 2.8" (70 mm) O-ring Placing Tool (25-6470). 1 2.8" (70 mm) Membrane Tester (25-6443). 1 2.8" or 70 mm Suction Membrane Device (25-6660 or 25-6480). EI25-0686/02. 110vAC, 50/60 Hz, 1ø, English. EI25-0686/01. 220vAC, 50/60 Hz, 1ø, English. EI25-0687/02. 110vAC, 50/60 Hz, 1ø, Metric. EI25-0687/01. 220vAC, 50/60 Hz, 1ø, Metric. For test applications involving toxic permeants, stainless steel Cap and Base Sets and two Pressure Interface Chambers are required for each test cell. 17

Tri-Flex 2 One-Cell Permeability Test System With the Tri-Flex 2 One-Cell Permeability Test System, efficient and accurate permeability testing of a wide range of construction materials can easily be conducted. The complete one-cell system consists of the Tri-Flex 2 Master Control Panel with water de-airing system, one Tri-Flex 2 Permeability Test Cell complete with platens for testing either 2.8" or 70 mm diameter specimens, and a complete range of sample preparation tools. Set includes: 1 Tri-Flex 2 Master Control Panel (25-0696/0x or 25-0697/0x). 1 Tri-Flex 2 Water De-airing Tank System (25-0698). 1 Tri-Flex 2 Permeability Test Cell (25-0690). 1 2.8" or 70 mm Acrylic Cap and Base Set 1 (25-0690/15 or 25-0690/10). 1 2.8" or 70 mm Porous Stones, pack of 2 (25-6721 or 25-6561). 1 2.8" or 70 mm Membrane Sealing Rings, pack of 10 (25-6641 or 25-6461). 1 2.8" (70 mm) Membranes, pack of 10 (25-6441). 1 2.8" (70 mm) O-ring Placing Tool (25-6470). 1 2.8" (70 mm) Membrane Tester (25-6443). 1 2.8" or 70 mm Suction Membrane Device (25-6660 or 25-6480). EI25-0684/02. 110vAC, 50/60 Hz, 1ø, English. EI25-0684/01. 220vAC, 50/60 Hz, 1ø, English. EI25-0685/02. 110vAC, 50/60 Hz, 1ø, Metric. EI25-0685/01. 220vAC, 50/60 Hz, 1ø, Metric. For test applications involving toxic permeants, stainless steel Cap and Base Sets and two Pressure Interface Chambers are required for each test cell. 18

Pressure Interface Chamber Stainless steel lower chamber and base construction with Viton diaphragm and O-rings. Supplied with all necessary valves and tubing. Construction. Stainless steel base and lower chamber; clear acrylic upper chamber and top;viton diaphragm and O-rings. Net 12 lbs. (5.5 kg). The Pressure Interface Chamber (PIC) is used during permeability test application involving toxic permeants.the chambers provide a closed system for toxic liquids entering and exiting the test cell. Note: Two Pressure Interface Chambers are required for use with each test cell. EI25-0695. Sample Preparation Tools Please refer to page 13 for a complete listing of available tools used to properly prepare specimens for testing. Tri-Flex 2 Master Control Panel Please refer to page 14 for complete specifications on the Tri-Flex 2 Master Control Panel and accessories. Three independent channels of pressure control. Digital pressure display system to an accuracy of ±0.25% of reading within range. User friendly burette system. Easy removal of burette/annulus assembly for cleaning. Bridging feature to set multiple burette pressures with one regulator. Quick disconnects for easy system setup. Easily expands for multi-cell test. EI25-0696/02. English. 110vAC, 50/60 Hz, 1ø. EI25-0696/01. English. 220vAC, 50/60 Hz, 1ø. EI25-0697/02. Metric. 110vAC, 50/60 Hz, 1ø. EI25-0697/01. Metric. 220vAC, 50/60 Hz, 1ø. EI25-0697/10. 10 ml Burette Assembly for manual pore pressure measurements. EI25-0698. Water De-Airing Tank System. EI25-0699. Auxiliary Control Panel. Compressed air, water and vacuum source required for panel operation. 19

Specimen Size. Head Assembly. Base Assembly. Cylinder. Max. Pressure. Tubing. Dimensions. 1.4" (35 mm) to 4" (102 mm) diam. using optional Cap and Base Sets, not included. Anodized aluminum with quick-disconnect fill/vent port and three clamping rods. Stainless steel with four stainless steel no-volume change ball valves for inflow and outflow ports and one brass no-volume change ball valve for lateral port. Clear acrylic. 150 psi (1,034 kpa). Teflon and stainless steel. Approx. 8" diam. x 15" h. (203 x 381 mm). Excluding valves. Net 23 lbs. (10.4 kg). EI25-0690. EI25-0695. Pressure Interface Chamber.Two required per cell. Permeability Cell Cap & Base Sets: Acrylic Stainless Steel 1.4" (35 mm) EI25-0690/13 EI25-0695/13 2.416" EI25-0690/14 EI25-0695/14 2.8" EI25-0690/15 EI25-0695/15 70 mm EI25-0690/10 EI25-0695/10 4.0" EI25-0690/17 EI25-0695/17 100 mm EI25-0690/12 EI25-0695/12 Porous Stones (Pack of 2): 1.4" (35 mm) EI25-4461 2.416" EI25-5661 70 mm EI25-6561 2.8" EI25-6721 100 mm EI25-7661 4.0" EI25-7761 Tri-Flex 2 Permeability Test Cell Corrosion resistant construction. Double drainage lines. Accepts a wide range of samples. The Tri-Flex 2 Permeability Test Cell incorporates many new features that promote ease in specimen preparation and installation.the cell consists of an aluminum alloy head assembly and a stainless steel base for corrosion resistance and long service life. Stainless steel no-volume change type valves at all specimen inflow and outflow ports provide additional corrosion resistance and prevention of pressure changes during permeability test procedures. Through the use of the cell s optional Platen Sets, the Tri-Flex 2 Permeability Test Cell can accept specimens ranging in size from 1.4" (35 mm) to as large as 4" (102 mm) in diameter. Depending on test requirements, all Platen Sets are available in either acrylic or stainless steel construction. Sealing Rings (Pack of 10): 1.4" (35 mm) EI25-4281 2.416" EI25-5663 70 mm EI25-6461 2.8" EI25-6641 4.0" (100 mm) EI25-7631 Rubber Membranes (Pack of 10): 1.4" (35 mm) EI25-4261 2.416" EI25-5665 2.8" (70 mm) EI25-6441 4.0" (100 mm) EI25-7621 20

Guelph Permeameter ASTM D-5126. Lightweight and portable for easy transportation. Test time of two hours or less. Requires only 2.5 liters of water. The Guelph Permeameter is a constant head permeameter that measures in-situ hydraulic conductivity. It is a simple to operate, portable unit that requires very little training to use. Only one person is needed to perform the test. The method involves measuring the steady-state rate of water recharge into unsaturated soil from a cylindrical well hole, in which a constant head of water is maintained. Calculations are made to determine the hydraulic conductivity, soil sorptivity and soil matrix flux potential. Depending on the soil type, tests can take between 1/2 hour and 2 hours using only 2.5 liters of water. Permeameter. Auger. Carrying Case. Test Time. Test Depth. Hydraulic Conductivity Range. High impact polycarbonate, molded elastomers. 2" (50.8 mm) diam.; machined steel. Die-cut foam for parts storage. 1/2 2 hours. 15 to 75 cm (0.5 to 2.5 ft). 10-4 to 10-8 m/sec (10-2 to 10-6 cm/sec). Net 30 lbs. (13.6 kg). Double Ring Infiltrometer ASTM D-3385. Determines infiltration rate of various soils. Heavy-duty aluminum rings for rust resistance and long life. Graduated Mariotte tubes for inner and outer rings. The Double-Ring Infiltrometer provides comparative information that is useful for determining erosion rates, leaching and drainage efficiencies, irrigation patterns, rainfall and evaluation of potential septic tank disposal fields. The instrument consists of two concentric rings, driving cap, two graduated Mariotte tubes, square neoprene splash guards and complete instructions.the two rings are driven into the ground and filled with water.the outer ring acts as a barrier to encourage only vertical flow from the inner ring. Rings. Driving Cap. Splash Guards. Mariotte Tubes. EI25-0660. Aluminum; two included, 12" i.d. x 20" h. (305 x 508 mm) and 24" i.d. x 20" h. (610 x 508 mm). Aluminum; 1/2" (12.7 mm) thick; with centering pins. Neoprene; two included; 6" (152 mm) square. Graduated; two included; 3,000 ml and 10,000 ml capacities. Net 70 lbs. (31.7 kg); Shpg. 90 lbs. (40.8 kg). EI25-0650. EI25-0655. Permeameter Extension Kit. 31-1/2" (800 mm) long. Increases test depth to 155 cm (5.16 ft). 21

Constant Head Sand/Gravel Permeameters ASTM D-2434. Meets ASTM D-2434 Test. Available in a wide range of sizes. Supplied complete with tubing and hardware. Accessory Manometer Panel and Constant Head Tank Assemblies. The Sand/Gravel Permeameter is used specifically for testing the permeability of granular soils. Manufactured in accordance with ASTM D-2434 test specifications, the permeameter is designed to provide accurate results when performing the constant head test method for the laminar flow of water through granular materials. A range of models to accommodate different particle sizes of specimens is available. Each Permeameter comes equipped with valves, porous stones and tubing for connection to a water source, vacuum, and manometer tubes.to prevent soil density changes during the test, a spring is incorporated in the top cap to apply 5 to10 lbf. (2.2 to 4.5 kg) against the top porous stone. Two manometer ports are grooved and screened on the inside of the chamber. The screens prevent material from migrating through the valves and tubing during testing.the acrylic chamber permits viewing of the sample during testing.the end caps and clamping ring are constructed of anodized aluminum for rust resistance and long service life. Construction. Manometer Ports. Clamping Rods. Weights. Anodized aluminum end caps and clamping ring acrylic chamber. Two. Located on the acrylic chambers side wall.the distances between ports are equal to the diameter. Three; quick release type. Net 7-12 lbs. (3.2-5.4 kg). Note: Manometer Panel and Constant Head Tank System; not included, order separately. EI25-0562. 3.0" (76 mm) i.d. EI25-0563. 4.5" (114 mm) i.d. EI25-0564. 6.0" (152 mm) i.d. EI25-0567. EI25-0568. Manometer Panel ASTM D-2434. Wall Mounted Manometer Panel. Constant Head Tank System. The Manometer Panel features two acrylic tubes and valving mounted on an aluminum rail with a 100 cm long dual-graduated scale. Each tube has its own valve, making it possible to run two independent permeability tests. Scale. Rail. Flow Tubes. EI25-0567. 100 cm long with cm and mm graduations. Aluminum construction with holes for wall mounting. Acrylic; each with its own flow control valve. Net 7 lbs. (3.2 kg). Constant Head Tank System ASTM D-2434. The system consists of an acrylic tank with regulating valve for flow control of water. A porous media is used at the bottom of the tank to filter out air bubbles. The unit maintains a constant water head by utilizing an overflow port. It also allows for connection to a tap water or de-aired water source. A wall mounting support, consisting of two rails with adjustable height brackets and tubing for connection between the tank and permeameter is included. Tank. Other Components. EI25-0568. 1000 cc. capacity, Clear acrylic with regulating valve. Wall mount, tubing and saddle valve. Net 8 lbs. (3.6 kg). 22

Compaction Permeameters Available in either 4" (101.6 mm) or 6" (152.4 mm) diameter models. Sturdy construction for testing all types of materials. Overflow valve assembly permits easy air removal before testing. Compaction Permeameters are designed for performing either constant head or falling head permeability tests on undisturbed, remolded or compacted soils. Mold. Capacity. Collar. Top. Base. Porous Stone. Weights. Machined seamless steel tubing; plated. EI25-0618: 1/30 cu. ft.; 4" i.d. x 4.584" h. (101.6 x 116.4 mm). EI25-0619: 0.1145 cu. ft.; 6" i.d. x 7" h. (152.4 x 177.8 mm). 2" h. (50.8 mm); machined seamless steel tubing; fits either end. of mold; plated. Cast aluminum; with overflow valve assembly and water connection. Cast aluminum; with inlet/outlet fitting. EI25-0618: 4" diam. x 1/2" thick (101.6 x 12.7 mm). EI25-0619: 5-15/16" diam. x 1/2" thick (150.8 x 12.7 mm). 50-70 permeability rating; 225 micron, average pore size. EI25-0618: Net 12 lbs. (5.4 kg). EI25-0619: Net 24 lbs. (10.9 kg). EI25-0618. Compaction Permeameter, 4" (101.6 mm). EI25-0619. Compaction Permeameter, 6" (152.4 mm). EI25-0620. Constant and Falling Head Accessory Kit. Includes a burette and meter stick for falling head tests and a constant head funnel both mounted on a support stand. Combination Permeameter Constant or Falling Head Plated steel chamber head assembly. Rust-resistant cast aluminum base assembly. Includes accessories for conducting both constant and falling head permeability studies. The Combination Permeameter is designed for laboratory determinations of permeability of either fine-grained or coarse-grained soils. Generally, soils containing 10 percent or more particles passing a no. 200 sieve are tested using the falling head assembly. More granular soils, containing 90 percent or more particles retained on the no. 200 sieve, are tested using the constant head assembly. In constant head permeability testing, a plastic funnel reservoir with overflow port is mounted on an upright attached to the chamber head. A maximum head of up to 55 cm is possible by placement of the reservoir on the upright. Falling head permeability studies are possible using the graduated pipette falling head reservoir which has a volume of 100 cc. Maximum head is 100 cm. Clear plastic chamber accepts 2-1/2" (63.5 mm) diameter specimens, ranging from 2-1/2" (63.5 mm) to 5-1/2" (140 mm) long. Specimen Size. Chamber. Base. Top Seal. Porous Stones. Constant Head. Falling Head. 2-1/2" diam. x 2-1/2" l. max. (63.5 x 63.5 mm) when using lower chamber only; 2-1/2" diam. x 5-1/2" l. max. (63.5 x 140 mm) when using both lower and extension chambers. Clear lucite; 1/4" (6.3 mm) wall; two sections. Cast aluminum. Plated steel with gaskets. Mounts at top and bottom; 2.47" diam. x 1/2" thick (62.7 x 12.7 mm); 105-120 permeability rating; 300 micron, average pore size. Plastic; funnel reservoir; 55 cm maximum head. Graduated pipette; 100 cc x 0.2 cc; 100 cm. maximum head. Net 11 lbs. (5 kg). EI25-0623. 23