Non-Return Valves T55 Series

Similar documents
Quick Release Couplings 233 Series

C 0G 00 N/US

Pneumatic Function Fittings Metric & Inch

B74G - EXCELON Modular System General purpose filter/regulator

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators

ISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4

R18 General purpose pressure regulators

R84G - Excelon Plus Modular System Pressure regulators

B84G - Excelon Plus Modular System General purpose filter/regulator

Pneumatic pressure switch 20DD

F68G - Olympian Plus plug-in system General purpose filter

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Nugget 120 V14 Series

B84G - Excelon Plus Modular System General purpose filter/regulator

SPCH/ Blowing block

Piloted Non-Return Valves

KM/ Stainless steel air bellows Single acting Ø 220 to 400 mm

250 (9.84) 170 (6.69) 225 (8.85) 75 (2.95) 300 (11.81)

Nugget 120 V14 Series

Precision and Instrument Regulators 1/4" port size

Model range*1) Switching pressure difference

Relief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm

Parker Legris Machine Safety: Product Sheets

KM/31000 (Stainless steel end plates) Air bellows, single acting

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Product Data Screwed Valves

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

Pilot Check Valve: Metal Body Type

Direct Operated Precision Regulator Modular Style. Standard Specifications

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

Standard Specifications

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

F l o w c o n T R o l v a l v E S

Coiling Tube with Twist-Proof Fitting

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

// ADapters GUIDelines

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

Regulator/Modular Style AR1000 to 6000

Precision Pressure Regulators

M/160300/M/11, M/160300/M/12 Angular grippers

Push-In Fitting Type Silencer

SOLENOID VALVES AND PNEUMATIC VALVES

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

Ball Valve Series. Push-In Fitting Type Shut-off Valve. Control Open/Close Air Supply. Ensure Effective Area for Variety of Tube Dia.

THREAD/SCREW - Drill & Tap Chart

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

Related Products: Auto Drain Valve. Model/Specifications. Model

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

BGA158 Series CE Approved Class B Shutoff Gas Valve

WARNING. Work drop prevention check valves FPV series. Vacuum accessories. Safety handling of workpiece with several pads

EXCELON QUIKCLAMP SYSTEM Pressure relief valves V72G, V74G - G1/4... G 3/4

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

SAFETY LOCKOUT VALVES

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Pneufit Metric Series Push-In Tube Fittings 4 mm to 14 mm Tube Sizes M5 to 1/2" ISO G and ISO R Thread Options

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Choosing the right miniature instrument and control valve is a snap

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

FITTING IDENTIFICATION AMERICANT THREAD TYPES APPENDIX ALFAGOMMA // APPENDIX. Dash numers. NPTF (National Pipe Tapered Fuel)

TYPE A Male camlock-female BSPP

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Dual Solenoid Gas Valve Installation

relief valves Circle Seal Controls 2301 Wardlow Circle Corona, CA Phone (951) Fax (951)

V248 Series 3-Way Pressure-Actuated. Water-Regulating Valves for High-Pressure

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Technical Information Ball valves for high pressure applications

relief valves R6000 Series

Booster Regulator/Air Tank

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Pressure Gauge Series

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

ALF400 to 900, ALT-5/-9

Modular Type Regulators

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

COMPRESSION TUBE FITTINGS

Avenger Model 33M Installation & Operation Instructions

2-JAW SELF-CENTERING PARALLEL PNEUMATIC GRIPPER (SERIES HS)

Coding of banjo flow controllers. Actuation M = Manual S = Screwdriver

Push-In Fitting Type with Stop Valve

Push-in fittings QB, NPT

Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

High Pressure Equipment Taper Seal Valves, Fittings and Tubing

GM-7000 Series CE Approved Gas Control Valve

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

(1) Type (2) Tube dia. (ød(1)) (3) Thread size (T) (4) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist

STAUFF Accumulators Accessories

Product Range. Product Range

Valves ISO 5599/1 ISO 1, 5/2-5/3, electrically operated, with CNOMO pilot

Safety-Related Products from ROSS CONTROLS Complete Your System.

Transcription:

T55 Series In-Line, Non-Return Valves M5, 1 8", 1 2" BSPP, BSPT, NPT Permit free flow of air in one direction only Simple, reliable design Light weight Silicone free Low cracking pressure Technical ata Medium: ompressed air, filtered, lubricated and non-lubricated Operation: Non-return valve Mounting: Line mounted Port Sizes: Metric BSPP BSPT NPT M5 T55M0500 G 1 8T551800 Rc 1 8 T55B1800 1 8 NPTT55A1800 G 1 4T552800 Rc 1 4 T55B2800 1 4 NPTT55A2800 G 3 8T553800 Rc 3 8 T55B3800 3 8 NPTT55A3800 G 1 2T554800 Rc 1 2 T55B4800 1 2 NPTT55A4800 Ordering Information To order, quote model number from table overleaf. e.g. T552800 for the G 1 4model Alternative Models T50 Series In-line push-in non-return valves see page 5.10.002 T56 Series In-line male-female non-return valves. T5/520 Series Heavy uty non-return valves. 1 2 Operating Pressure: 0.1-10 bar Operating Temperature: -20 * to +80 *onsult our Technical Service for use below +2 Materials Aluminium body, silicone free nitrile rubber O ring, POM valve, stainless steel spring 1 2 03/99 N/AL 5.10.004.01

General Information Model Port Free Flow racking size Flow factor Pressure Weight Metric BSPP BSPT NPT * v** (bar) (gs) T55MO500 M5 0.8 0.19 0.05 10 * : measured in dm 3 /(s.bar) V** : measured in US gall/min T551800 T55B1800 T55A1800 1 8 2.4 0.59 0.05 15 T552800 T55B2800 T55A2800 1 4 5.5 1.35 0.05 25 T553800 T55B3800 T55A3800 3 8 9.0 2.20 0.05 60 T554800 T55B4800 T55A4800 1 2 15.0 3.70 0.05 80 Non-return Valve B E G A A/F ØF ØH Model T55MO500 T55A1800 T55B1800 T551800 T55A2800 T55B2800 T552800 T55A3800 T55B3800 T553800 T55A4800 T55B4800 T554800 A 11 14 14 14 17 17 17 24 24 24 27 27 27 B 27.5 42.5 42.5 42.5 54 54 54 63 63 63 77 77 77 M5 1/8 1/8 1/8 1/4 1/4 1/4 3/8 3/8 3/8 1/2 1/2 1/2 5 - - 7 - - 10.5 - - 12 - - 15 E 4 7 7 7 8 8 8 9 9 9 12 12 12 F 10.7 13.7 13.7 13.7 16.7 16.7 16.7 23.7 23.7 23.7 26.7 26.7 26.7 G 3 4 4 4 5 5 5 7 7 7 10 10 10 H 12 15 15 15 18.5 18.5 18.5 26 26 26 30 30 30 Warning These products are intended for use in industrial compressed air systems only. o not use these products where pressures and temperatures can exceed those listed under Technical ata. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. N/AL 5.10.004.02 03/99

T56 Series In-Line, Non-Return Valves M5, 1 8", 1 4" Permit free flow of air in one direction only Simple, reliable design Male/Female connections Silicone free Low cracking pressure O ring in the parallel threads Technical ata Medium: ompressed air, filtered, lubricated and non-lubricated Operation: Non-return valve Mounting: Line mounted Port Sizes: Metric BSPP BSPT NPT M5 T56M0500 1 8 T561800 1 8 T56B1800 1 8 T56A1800 1 4 T562800 1 4 T56B2800 1 4 T56A2800 Ordering Information To order, quote model number from table overleaf. e.g. T562800 for the 1 4 BSPP model. Alternative Models T50 Series In-line push-in non-return valves see page 5.10.002 T55 Series Female Female In-line non-return valves. T5/520 Series Heavy uty non-return valves. 1 2 Operating Pressure: 0.1-10 bar Operating Temperature: -20 * to +80 *onsult our Technical Service for use below +2 Materials Brass body, silicone free nitrile rubber O ring, POM valve. 1 2 03/99 N/AL 5.10.001.01

General Information Model Port Free Flow racking size Flow factor Pressure Weight Metric BSPP BSPT NPT * v** (bar) (gs) T56MO500 M5 0.55 0.19 0.05 18 T561800 T56B1800 T56A1800 1 8 2.4 0.59 0.05 45 T562800 T56B2800 T56A2800 1 4 5.0 1.23 0.05 80 * : measured in dm 3 /(s.bar) V** : measured in US gall/min Non-return Valve B I E G A A/F ØF ØH Model T56MO500 T56A1800 T56B1800 T561800 T56A2800 T56B2800 T562800 A 11 14 14 14 17 17 17 B 31.8 49 49 45 62.5 59 56.2 M5 1/8 1/8 1/8 1/4 1/4 1/4 5 - - 7 - - 10.5 E 4 4.5 4.5 4.5 5.2 5.2 5.2 F 10.7 13.7 13.7 13.7 16.7 16.7 16.7 G 3 4 4 4 5 5 5 H 12 15 15 15 18.5 18.5 18.5 I 4.3 9.5 9.5 5.5 14.3 11 8 Warning These products are intended for use in industrial compressed air systems only. o not use these products where pressures and temperatures can exceed those listed under Technical ata. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. N/AL 5.10.001.02 03/99

T56 Series In-Line, Non-Return Valves M5, 1 8", 1 4" Permit free flow of air in one direction only Simple, reliable design Male/Female connections Silicone free Low cracking pressure O ring in the parallel threads Technical ata Medium: ompressed air, filtered, lubricated and non-lubricated Operation: Non-return valve Mounting: Line mounted Port Sizes: Metric BSPP BSPT NPT M5 T56M0500 1 8 T561800 1 8 T56B1800 1 8 T56A1800 1 4 T562800 1 4 T56B2800 1 4 T56A2800 Ordering Information To order, quote model number from table overleaf. e.g. T562800 for the 1 4 BSPP model. Alternative Models T50 Series In-line push-in non-return valves see page 5.10.002 T55 Series Female Female In-line non-return valves. T5/520 Series Heavy uty non-return valves. 1 2 Operating Pressure: 0.1-10 bar Operating Temperature: -20 * to +80 *onsult our Technical Service for use below +2 Materials Brass body, silicone free nitrile rubber O ring, POM valve. 1 2 03/99 N/AL 5.11.001.01

General Information Model Port Free Flow racking size Flow factor Pressure Weight Metric BSPP BSPT NPT * v** (bar) (gs) T56MO500 M5 0.55 0.19 0.05 18 T561800 T56B1800 T56A1800 1 8 2.4 0.59 0.05 45 * : measured in dm 3 /(s.bar) V** : measured in US gall/min Non-return Valve B I E G A ØF ØH Model T56MO500 T56A1800 T56B1800 T561800 T56A2800 T56B2800 T562800 A 11 14 14 14 17 17 17 B 31.8 49 49 45 62.5 59 56.2 M5 1/8 1/8 1/8 1/4 1/4 1/4 5 - - 7 - - 10.5 E 4 4.5 4.5 4.5 5.2 5.2 5.2 F 10.7 13.7 13.7 13.7 16.7 16.7 16.7 G 3 4 4 4 5 5 5 H 12 15 15 15 18.5 18.5 18.5 I 4.3 9.5 9.5 5.5 14.3 11 8 Warning These products are intended for use in industrial compressed air systems only. o not use these products where pressures and temperatures can exceed those listed under Technical ata. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. N/AL 5.11.001.02 03/99