Space product assurance

Similar documents
ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

WP2 Fire test for toxicity of fire effluents

This test shall be carried out on all vehicles equipped with open type traction batteries.

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

ISO INTERNATIONAL STANDARD

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Operation of the Perkin Elmer TGA-GC/MS

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Gaseous oxygen technical grade Specification

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

STANDARD OPERATING PROCEDURES

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Agilent 490 Micro GC Natural Gas Analyzer

INTERNATIONAL STANDARD

ANALYSIS OF GASES PRODUCED BY THREE UNDERWATER CUTTING DEVICES

Rapid and Reliable Detection of Dissolved Gases in Water

Carrier Gases in Capillary GC

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

3. Coupled Techniques in Thermal Analysis

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

3 Flow and Pressure Control

Major Design Features

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

Multiple Gas#5 GC configuration Jan 2016

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

ISO INTERNATIONAL STANDARD. Welding consumables Gases and gas mixtures for fusion welding and allied processes

ISO INTERNATIONAL STANDARD

VIC offers a variety of Calibrated Gas Leaks

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Retention Time Locking: Concepts and Applications. Application

Quadruple mass spectrometers (transducer type)

The Polyethylene Casing as Diffusion Barrier for Polyurethane Insulated District Heating Pipes

Background Statement for SEMI Draft document 4657B NEW STANDARD: SPECIFICATIONS FOR TUNGSTEN HEXAFLUORIDE (WF 6 )

Your local gas generation partner. Precision series Modular gas generation solution for GC.

M/s. Thermo fisher Scientific

The analysis of complex multicomponent

International Civil Aviation Organization DANGEROUS GOODS PANEL (DGP) MEETING OF THE WORKING GROUP OF THE WHOLE. Montreal, 18 to 22 April 2005

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

METHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1.1 Applicability. This procedure is applicable for

Gases and welding distributors continue

ISO 9539 INTERNATIONAL STANDARD. Gas welding equipment Materials for equipment used in gas welding, cutting and allied processes

CORESTA RECOMMENDED METHOD Nº 67

User manual. TC-20 Sample conditioning and dry-purge rig. QUI-0003 Version 6.3 September

Zebron Gas Management

ISO INTERNATIONAL STANDARD. Flow-metering devices for connection to terminal units of medical gas pipeline systems

USE OF RESIDUAL PRESSURE VALVES

Space product assurance

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

STANDARD OPERATING PROCEDURES

COMMERCIAL ITEM DESCRIPTION NITROGEN, TECHNICAL

STANDARD OPERATING PROCEDURES

Automated Determination of Dissolved Gases in Water Anne Jurek

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

Technical Specifications of Hydrogen Isotope Handling and Recovery System

AWS C2.21M/C2.21:2003 An American National Standard. Specification for Thermal Spray Equipment Acceptance Inspection

ISO/TR TECHNICAL REPORT. Natural gas Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation)

ISO/TC 112/WG 2 N 49. ISO TS QMS WD v6. Date of document Expected action Comment Due Date Background

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

TECHNICAL SPECIFICATION

Basic & Controlled Atmosphere Glove Boxes

Thermo Scientific Chromatography Well Plates

Thermo Scientific Chromatography Well Plates

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

Pharmaceutical Grade Nitrogen & Gardner Denver / CompAir PSA Nitrogen Gas Generation Systems

Gas mixtures. Individual solutions specifically for your application

Agilent G3180B Two-Way Splitter Kit

RULES FOR CLASSIFICATION Naval vessels. Part 1 Classification and surveys Chapter 5 Surveys for submarines. Edition January 2016 DNV GL AS

Your local gas generation partner. Precision series Modular gas generation solution for GC.

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

EN1279 part 3 assessment of insulating glass: IGU with Duralite sealant

Agilent Dimension Software for ELSD User Manual

INTERNATIONAL STANDARD

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

ISO INTERNATIONAL STANDARD. Inflatable boats Part 2: Boats with a maximum motor power rating of4,5kwto15kwinclusive

EUROPEAN pr I-ETS TELECOMMUNICATION September 1995 STANDARD

This standard is due for Five Year Review. This process is required by the SEMI Regulations to ensure that the standard is still valid.

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

Discovery HP-TGA 75/750. Site Preparation Guide

PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, ARGON

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

Residual Gas Analysis Systems for Industry

Best Practice for Identifying Leaks in GC and GC/MS Systems

Transcription:

ECSS-Q-ST-70-29C Space product assurance Determination of offgassing products from materials and assembled articles to be used in a manned space vehicle crew compartment ECSS Secretariat ESA-ESTEC Requirements & Standards Division Noordwijk, The Netherlands

Foreword This Standard is one of the series of ECSS Standards intended to be applied together for the management, engineering and product assurance in space projects and applications. ECSS is a cooperative effort of the European Space Agency, national space agencies and European industry associations for the purpose of developing and maintaining common standards. Requirements in this Standard are defined in terms of what shall be accomplished, rather than in terms of how to organize and perform the necessary work. This allows existing organizational structures and methods to be applied where they are effective, and for the structures and methods to evolve as necessary without rewriting the standards. This Standard has been prepared by the ECSS Executive Secretariat, endorsed by the Document and Discipline Focal points, and approved by the ECSS Technical Authority. Disclaimer ECSS does not provide any warranty whatsoever, whether expressed, implied, or statutory, including, but not limited to, any warranty of merchantability or fitness for a particular purpose or any warranty that the contents of the item are error free. In no respect shall ECSS incur any liability for any damages, including, but not limited to, direct, indirect, special, or consequential damages arising out of, resulting from, or in any way connected to the use of this Standard, whether or not based upon warranty, business agreement, tort, or otherwise; whether or not injury was sustained by persons or property or otherwise; and whether or not loss was sustained from, or arose out of, the results of, the item, or any services that may be provided by ECSS. Published by: Copyright: ESA Requirements and Standards Division ESTEC, P.O. Box 299, 2200 AG Noordwijk The Netherlands 2008 by the European Space Agency for the members of ECSS 2

Change log ECSS Q 70 29A 30 July 1999 ECSS Q 70 29B ECSS Q ST 70 29C First issue Transforming ESA PSS 01 729 into an ECSS Standard Never issued Second issue Redrafting ECSS Q 70 09A according to ECSS drafting rules and new template. 3

Table of contents Change log...3 1 Scope...6 2 Normative references...7 3 Terms, definitions and abbreviated terms...8 3.1 Terms defined in other standards...8 3.2 Terms specific to the present standard...8 3.3 Abbreviated terms...9 3.4 Formula for conversion...9 4 Requirements...10 4.1 Preparatory conditions...10 4.1.1 Test specimen preparation...10 4.1.2 Cleaning...12 4.1.3 Identification...12 4.2 Test facility...12 4.2.1 General requirements...12 4.2.2 Test chamber...12 4.2.3 Sampling equipment...13 4.2.4 Analytical equipment...13 4.2.5 Gas supplies...14 4.3 Test chamber certification procedure...14 4.4 Test procedure...15 4.4.1 Test conditions...15 4.4.2 Test execution...15 4.4.3 Analysis of samples...16 4.5 Acceptance limits...16 4.5.1 Materials...16 4.5.2 Assembled articles, experiments and racks...16 4.6 Quality assurance...17 4.6.1 Data...17 4.6.2 Calibration...17 4

Annex A (normative) Offgassing evaluation report - DRD...18 Annex B (informative) Example of test method procedure...20 Bibliography...22 Tables Table 4-1: Slits setting...14 5

1 Scope All non metallic materials release trace contaminants into the surrounding environment; the extent to which this occurs is dependent on the nature of the material concerned. In the closed environment of a manned spacecraft contaminants within the atmosphere are potentially dangerous with respect to toxicity and its consequences for the safety of the crew. This Standard defines a test procedure for the determination of the trace contaminants release by non metallic materials under a set of closely controlled conditions. The test procedure covers both individual materials and assembled articles. In this Standard the supplier means the testing authority that is responsible for specifying and executing the offgassing tests. This Standard describes a test to provide data for aid in the evaluation of the suitability of assembled articles and materials for use in a space vehicle crew compartment. The data obtained are in respect of the nature and quantity of organic and inorganic volatile contaminants evolved when subjected to the crew compartment environment. This standard may be tailored for the specific characteristics and constrains of a space project in conformance with ECSS S ST 00. 6

2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this ECSS Standard. For dated references, subsequent amendments to, or revision of any of these publications do not apply, However, parties to agreements based on this ECSS Standard are encouraged to investigate the possibility of applying the more recent editions of the normative documents indicated below. For undated references, the latest edition of the publication referred to applies. ECSS S ST 00 01 ECSS Q ST 10 09 ECSS Q ST 70 ECSS system Glossary of terms Space product assurance Nonconformance control system Space product assurance Materials, mechanical parts and processes 7

3 Terms, definitions and abbreviated terms 3.1 Terms defined in other standards For the purpose of this Standard, the terms and definitions from ECSS S ST 00 01 and ECSS Q ST 70 apply. 3.2 Terms specific to the present standard 3.2.1 assembled article any component black box or assembly of components which represents the article to be used in a spacecraft 3.2.2 experiment item designed and built to accomplish a specific purpose which can be disassembled and retain its capabilities after re assembly 3.2.3 offgassing evolution of gaseous products for an assembled article subjected to slight radiant heat in the specified test atmosphere 3.2.4 offgassing product organic or inorganic compound evolved from a material or assembled article or experiment or rack 3.2.5 rack structure in which different experiments take place during a manned mission 3.2.6 SMAC (Spacecraft Maximum Allowable Concentration) maximum concentration of a volatile offgassed product that is allowed in the spacecraft atmosphere for a specified flight duration 3.2.7 toxic hazard index (T) ratio of the projected concentration of each offgassed product to its SMAC value and summing the ratios for all offgassed products without separation into toxicological categories Further details on the calculation of this T value can also be obtained in NASA STD 6001. 8

3.3 Abbreviated terms For the purpose of this Standard, the abbreviated terms from ECSS S ST 00 01 and the following apply: Abbreviation Meaning C concentration expressed in μg/m 3 C1 CI ± EI ev GC MS MWt m/z ppm SMAC T concentration expressed in ppm chemical ionization electron ionization electron volt gas chromatograph mass spectrometer molecular weight ratio mass to charge part per million Spacecraft Maximum Allowable Concentration toxic hazard index For μg/m3, the conversion to ppm is done, using the formula ((3 1) given in clause 3.4 3.4 Formula for conversion Formula (3 1) shows the conversion from μg/m 3 to ppm: C = C MW 1 t 10 3 24,47 P 298 1013 273 + t (3 1) Where: C is the concentration (μg/m 3 ) C1 is the concentration (ppm) MWt is the molecular weight (g) P is the pressure (hpa) t is the room temperature ( C) (End of test) 24,47 is the molecular volume at 25 C (l) 9

4 Requirements 4.1 Preparatory conditions 4.1.1 Test specimen preparation 4.1.1.1 General preferences a. The supplier shall classify all materials to be tested into one of the three categories Surface, Volume and Mass described in 4.1.1.2, 4.1.1.3 and 4.1.1.4, respectively. 4.1.1.2 Samples of category Surface a. The category Surface shall include films, fabrics, coatings, finishes, inks, primers, adhesives, thin film lubricants, tapes and electrical insulating materials. This category is defined for materials that are essentially two dimensional. b. The supplier shall select test samples with a surface of (300 ± 10) cm 2 per litre of test chamber. c. Coatings and finishes shall be coated on a clean aluminium substrate. d. Material thickness, curing process and method of application shall be in accordance with the manufacturer s recommendations. Only the outer surfaces of a material on the aluminium panel are counted in surface area determinations. e. The supplier shall cut films, fabrics and similar materials to ensure a surface of (300 ± 10) cm 2. Because materials are often two surfaced in use, the total surface area is determined by counting, the top and the bottom surface. f. Heat shrinkable tubing or boots shall be applied and shrunk to simulate actually used configuration. 10

4.1.1.3 Samples of category Volume ECSS Q ST 70 29C a. The category Volume shall include foams and other blown or foamed materials and insulating padding. This category is defined for materials having a defined volume but a large real surface area due to surface convolutions or matting. b. The supplier shall cut samples to a thickness of (1,25 ± 0,2) cm unless the existing thickness is less than 1,25 cm. In this case, the existing thickness shall be used. c. The supplier shall cut the samples to a surface size of (50 ± 5) cm 2 per litre of test container volume. d. The supplier shall use all surfaces, tops, bottoms and sides to calculate the total surface area. e. In cases where the cut pieces of the sample do not fit into the container because of its size, the supplier shall cut two or more pieces, as long as 4.1.1.3d. is met. 4.1.1.4 Samples of category Mass a. The category Mass shall include potting compounds, moulding compounds, cast of formed objects, solid wires and thick plastics. This category is defined for materials having a defined bulk but not falling into the volume classification. b. The supplier shall use the samples as much as possible in the supplied configuration and cut them to give (5,0 ± 0,25) g sample per litre of chamber volume. c. The supplier shall prepare and cut potted or moulded materials to adequate weight. 4.1.1.5 Assembled articles a. The supplier shall test assembled articles in the condition in which it was received. b. The supplier shall perform the offgassing test in a passive mode. Passive mode means that the test is performed without any power supply for the assembled article. 4.1.1.6 Racks a. The supplier shall test racks in the context of their specific requirements, in relation to safety, non degradation of equipments and vacuum resistance. b. The supplier shall perform the offgassing test in a passive mode. 11

4.1.2 Cleaning ECSS Q ST 70 29C a. The customer shall perform the same cleaning and treatment of the test article as the sample undergoes before integration into the spacecraft. 4.1.3 Identification a. The customer shall accompany materials submitted for testing by a completed Materials Identification, with technical specifications, expected degradation during the test, cure and post cure noted. b. A full description of each assembled article, material identification and location shall be provided with each article by the customer. 4.2 Test facility 4.2.1 General requirements a. A basic facility for the performance of the tests shall include a sealed test chamber, a sampling capability and the analytical equipment. 4.2.2 Test chamber a. The test chamber shall be hermetically sealable. b. The test chamber shall be of a sufficient size so that the material or assembled article can be contained. Best practice is to use the volume of the specimen equivalent to 1/3 of the test chamber. If the test chamber is considerably larger than the article under test, this can lead to over dilution of the offgassed products in the test chamber. c. The test chamber shall be constructed out of materials that do not offgass beyond the background level. Refer to the note in 4.3. d. The test chamber shall be accessible for any cleaning operation and shall allow full visibility of the sample under test. e. For cleaning purposes, the chamber shall have the capability to be evacuated to a pressure of 1,3 Pa or less, or to be purged with clean gas not below 80 C. f. Feed through connections shall be fitted to the chamber. This is done so that the temperature at various points on the article or rack may be measured. g. Heatable gas line connections shall be included for sampling of the test atmosphere. 12

h. The temperature control system shall be capable of maintaining the temperature in the test chamber uniformly within ± 2 C of the designated test temperature. i. The test chamber instrumentation shall have the capability to continuously record the temperature. j. The test chamber shall be equipped with an internal fan for the convection of the test atmosphere. k. A pressure gauge shall be installed such that the test pressure can be measured to an accuracy of ± 1 300 Pa. 4.2.3 Sampling equipment a. The sampling equipment shall consist of the following two basic types: 1. Direct atmosphere sampling using containers of accurately known volume for subsequent direct gas analysis. For example, chromatograph gas sampling loops and evacuated glass chambers. 2. Dynamic atmosphere sampling performed by passing a known volume of the test atmosphere through an enrichment device. 1 2 For example, a pre concentration adsorption trap and a cool empty loop. Additional sampling devices can be included such as specific gas monitoring equipment. b. The sampling volume extracted should not exceed 25 % of the total volume of the facility. 4.2.4 Analytical equipment a. A desorption or extraction device shall be used for the recovery and subsequent injection of the pre concentrated contaminants into the analytical instruments specified in 4.2.4b, 4.2.4c., and 4.2.4d. b. A gas chromatograph with at least one flame ionization detector, a temperature programming facility, the necessary data recording equipment and a capillary GC column shall be used. The capillary GC column is used in order to obtain maximum separation capability. c. A second gas chromatograph equipped with a gas sampling loop, pneumatic valves, a methanizer and a flame ionization detector shall be used for the determination of carbon monoxide, methane and total organics (screening test). Packed columns are sufficient in this case. d. A mass spectrometer, preferably connected to the gas chromatograph, and with the following parameters shall be used for the identification of the offgassed products where this cannot be done by gas chromatography alone: 13

1. Mass range: 1 700. 2. Excitation: 70 ev. 3. Mode: EI/CI ±. 4.2.5 Resolution (Static): at the slit settings provided, the resolution definition (10 % valley) is within the values listed in Gas supplies a. All carrier gases used shall be of purity not less than 99,99 %. For example Helium or Hydrogen. 1. Table 4 1. 2. The GC/MS parameters are such that 100 picograms of Methyl Stearate injected on to the GC capillary column gives a signal to noise ratio of 50:1, for a MS source on the molecular ion at m/z 298. b. Calibration devices shall be used. 1 For example, external standards, such as a complex gas mixture. 2 An infrared spectrometer with a multipath gas cell for use as a complementary system of investigation, in particular with respect to the identification of inorganic contaminants. 4.2.6 Gas supplies a. All carrier gases used shall be of purity not less than 99,99 %. For example Helium or Hydrogen. Table 4 1: Slits setting Size of the slit Resolution Organic reference equivalent 4 th (large) 600 (1 666 ppm) ± 20 % 3 rd 2 000 (500 ppm) ± 20 % 2 nd 4 000 (250 ppm) ± 20 % 1 st (small) 10 000 (250 ppm) ± 10 % 4.3 Test chamber certification procedure a. The test chamber certification procedure shall be as follows: 1. Heat the chamber prior to testing to at least 70 C for a period of 24 hours, either under a clean vacuum of < 1,3 Pa or with a continuous purge of clean dry nitrogen or helium gas. 2. Reduce the chamber temperature to the test temperature and fill the chamber with the specified test atmosphere to the test pressure and condition it for 72 hours. 14

3. Analyse the chamber atmosphere for residual contamination. 4. Certify the chamber as clean for use if the background level is sufficiently low to permit detection and quantification of offgassed products from the test specimen. Best practice is to have a background level less than 20 ppm or 59 mg/l, in Pentane equivalent. 4.4 Test procedure 4.4.1 Test conditions a. The test conditions shall be as follows: 1. Temperature: 50 C ± 2 C. 2. Atmosphere: at least 20,9 % oxygen, with the balance nitrogen or argon. 3. Pressure: 1 atmosphere pressure (1 013 hpa at 50 C). 4. Duration: 72 hours ± 1 hour. 4.4.2 Test execution a. The test procedure for both materials and assembled articles shall be as follows: 1. Place the clean, weighed test item into the test chamber and ensure, for assembled articles, experiments or racks, that all electrical connections are made. 2. Place the various temperature sensors on the spots to be monitored and close the chamber. 3. Expose the experiment to a vacuum of less than 100 hpa and less than 3 minutes. 4. In case the experiment is not resistant to vacuum, connect the chamber to the pressurisation system and purge it with the test atmosphere (through a molecular sieve trap) with a minimum volume of three times the chamber capacity. 5. After completion of the purge, adjust the test atmosphere to the test pressure. 940 hpa at room temperature provides a pressure close to 1 atmosphere at 50 C. 6. At the end of the defined duration, allow the chamber to cool down to room temperature by passive cooling. 7. Connect the sampling equipment to the chamber and take samples of the atmosphere within 12 hours after room temperature has been reached. 15

8. Open the chamber and note any relevant information. ECSS Q ST 70 29C For example, particular odour remaining in the chamber and condensation. 4.4.3 Analysis of samples 4.4.3.1 Materials screening test a. A material screening test shall be applied only to individual materials. b. The sample analysis shall identify the following: 1. Quantity of carbon monoxide offgassed in μg/g of material tested. 2. Quantity of total organic (expressed as pentane equivalents) offgassed in μg/g of material tested. 3. Identity and quantity of each contaminant offgassed in an amount in excess of 10 μg/g of material tested. 4.4.3.2 General test for materials and assembled articles a. In specific cases for materials tested, and in general for assembled articles and racks, the sample analysis shall identify and quantify all contaminants present. 4.5 Acceptance limits 4.5.1 Materials a. For materials the following acceptance limits shall apply: 1. Carbon Monoxide: 25 μg/g of material tested. 2. Total Organics: 100 μg/g of material tested. b. In cases where materials are added to an assembled article which has already been subjected to test, the material shall be tested and shall meet the same acceptance limits as the assembled article. For example, materials can be added as a result of repair or rework. 4.5.2 Assembled articles, experiments and racks a. The quantity of each individual offgassed product shall result in a predicted spacecraft concentration less than the SMAC value for that product. When this condition is not met, consider the rejection and retest of the article concerned. 16

b. The toxic hazard index T shall be determined by calculating the ratio of the projected concentration of each offgassed product to its SMAC value and summing the ratios for all offgassed products without separation into toxicological categories. c. The T value shall not exceed 0,5. d. Amount of each contaminant shall be expressed in μg/m 3 of the manned space vehicle crew compartment. e. The supplier shall assess the possible toxic hazards. Those toxic hazards due to the volatile contamination evolved from the assembled article under investigation and for impacts on the potential toxicity of the total quantity of offgassed products from all contaminant generating items for a given mission. 4.6 Quality assurance 4.6.1 Data a. The supplier shall retain the quality records for at least ten years, or in accordance with project business agreement requirements. For example, the logbooks. b. The supplier shall provide the offgassing evaluation report in conformance with Annex A DRD for customer approval. 4.6.2 Calibration a. The supplier shall calibrate any measuring equipment to traceable reference standards. b. The supplier shall record any suspected or actual equipment failure as a project nonconformance report according to ECSS Q ST 10 09. This is to ensure that previous results are examined to ascertain whether or not re inspection and retesting is necessary. 17

Annex A (normative) Offgassing evaluation report - DRD A.1 DRD identification A.1.1 Requirement identification and source document This DRD is called from ECSS Q ST 70 29, requirement 4.6.1b. A.1.2 Purpose and objective The purpose of the document is to describe the contents of the offgassing evaluation report. A.2 Expected response A.2.1 Scope and content <1> Materials, assembled articles and racks designation a. The report shall contain the following information for the material: 1. ID 2. Type of product 3. Chemical nature 4. Manufacturer 5. Procurements 6. Standards specifications 7. Summary of processing parameters. b. The report shall contain the following information for the assembled articles and racks: 1. Designation of the item 2. List of contents 3. Manufacturer 4. Reference and serial number 18

5. Application 6. Location. c. The report shall contain the description of the samples. <2> Test equipment a. The report shall contain the volume of the test chamber. <3> Test procedure a. The report shall contain the following information: 1. Test temperature duration 2. Test atmosphere (normal air, enriched oxygen concentration, nitrogen) 3. Test pressure at room temperature. <4> Test result a. The report shall contain the following information: 1. Result of analysis 2. Projected spacecraft volume. b. The report shall contain any observation during and after the test on material, assembled article or rack. Results are expressed in μg/g or μg/cm 2. A.2.2 None. Special remarks 19

Annex B (informative) Example of test method procedure B.1 Introduction The data given in B.2 to B.4 is for information purposes and reflects possible experimental system surroundings that can be found in any laboratory. It is included here for the purpose of guidance and serves as an example assembly. B.2 Test chamber a. HERAEUS model VHT 85/110: 1. Volume of test chamber: 718 l. 2. Temperature rise: From 22 C (room temperature) to 50 C in 20 minutes. 3. Set the fan to on. 4. Expose the experiment for 72 hours at 50 C, and then stop the heater. 5. Recovering time to reach room temperature and 940 hpa: 12 hours. 6. Clean and dry synthetic air or pure nitrogen is used. B.3 Sampling B.3.1 Gas 5 litre glass bottle. B.3.2 Ceramic Traps a. Ceramic trap model 1 010 R filled with Carbopack B from SUPELCO: 1. 60 mesh 80 mesh: equivalent to 100 m 2 ; 2. Pneumatic pumping system, flow rate: 24,33 ml/min; 3. Gas volume passing through the trap: 243,3 ml. 20

B.3.3 Direct sample ECSS Q ST 70 29C This analysis is performed to establish the real value of carbon monoxide (CO) and methane (CH4) produced by the experiment. The analytical equipment is a Gas Chromatograph equipped with a Methanizer and a Flame Ionization Detector (FID). The two columns are packed with Molecular Sieve and Porapak N. A backflush is used during the first period of the elution. B.3.4 Preconcentrated sample The ceramic trap 1 01 R filled with 243,3 ml of contaminated air is desorbed by using a microwaves desorption system, model MW 1A from REKTORIK (CH). Desorption time: 30 seconds Energy: 1 425 Ah 10 6 B.4 Analytical equipment a. A Gas Chromatograph equipped with a DB1701 column from J.W 1. Dimensions: 60 m 0,320 mm 2. Film thickness: 0,25 μm b. Temperature programme 1. 20 minutes at 20 C, then 1 C/min to 150 C 2. 150 C during 15 minutes then 2 C/min to 200 C c. Detector 1. Flame Ionization Detector (FID) at 180 C 2. Thermal Conductivity Detector (TCD) at 180 C d. Gas Carrier 1. Helium: 99,999 % 2. Flow rate: 2 ml/min e. A Mass Spectrometer, model Profile, from KRATOS (UK) 1. Magnet system 2. Mass range: 1 500 3. Excitation (Electron beam): 70 ev 4. Mode: EI 5. Scan rate: 0,6 seconds per decade 6. Resolution: 600 f. A SUN computer, using the MACH3 software, able to store simultaneously the MS and the GC signals (FID, TCD). g. The quantification is done by the GC signal, the identification by the MS signal, compared with 80 000 spectra in memory. 21

Bibliography ECSS S ST 00 NASA STD 6001 ECSS system Description, implementation and general requirements Flammability, Odor, Off gassing and Compatibility Requirements & Test Procedures for Materials in Environments That Support Combustion 22