Indian Institute of Technology Kanpur Environmental Engineering and Management Department of Civil Engineering

Similar documents
Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

FINAL REVISED TECHNICAL SPECIFICATION OF INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER (ICP-MS) WILL BE AS FOLLOWS:- GENERAL SPECIFICATIONS

The instrument should have a mass range from 2 to 2000 m/z or better Interface

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Hiden QIC Series Gas Analysers Real-time gas analysis systems

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Residual Gas Analysis Systems for Industry

PRC CO ² -LASER PRESENTATION

Agilent ICP-MS Interactive Troubleshooting tool for Low sensitivity

Features of Jobin Yvon ICP Spectrometers

Savillex Technical Note PFA Inert Kit for Thermo Element 2

DOS in Food Science & Nutrition, Manasagangotri, Mysore

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Agilent 4100 MP-AES. Specifications. Runs on air

The Helium Leak Detector

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Indian Institute of Technology Kanpur Samtel Centre for Display Technologies

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

LUMAZOTE T ECHNICAL BRO CHU RE

Major Design Features

DEBUBBLERS & DEGASSERS ACTIVE DEBUBBLERS APPLICATION NOTE WHY DEGAS YOUR MOBILE PHASE? PAGE 177 STAND ALONE DEGASSERS PAGE 175 PAGE 178

Agilent 4200 MP-AES. Specifications. Runs on air

Operation of the Perkin Elmer TGA-GC/MS

High Performance Mass Spectrometers

Thermo Scientific Model 146i Principle of Operation

Setting a New Standard in Flash Chromatography Performance

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

HumiSys HF High Flow RH Generator

The instrument will process the samples one by one till all the samples have been cleaned up.

Customer Responsibilities

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Agilent ICP-MS Interactive Troubleshooting tool for Plasma ignition problem

HPLC. Solvent Delivery Module Systems

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

ADDENDUM IMPORTANT DOCUMENT INVITATION TO BID ADDENDUM. OPENING DATE & TIME: January 3, 2018 at 3:00PM

Application Note AN-107

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

New Agilent 7900 ICP-MS Product Information. Redefining ICP-MS. Again! Agilent Restricted Jan

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

Series Environmental Chambers

1)! DO NOT PROCEED BEYOND THIS MARK

Precisely HPLC. Hints, Tips, Guidelines and Important Considerations. Presenters: Wilhad Reuter / Tom Breslin

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

The latest automotive systems require innovative leak test methods and fixturing.

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Varian 325-MS LC/MS Quadrupole Mass Spectrometer Pre-installation Instructions

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

LC, RSLC, Bio RS and Dual Gradient Systems

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

CORESTA RECOMMENDED METHOD Nº 67

Login to ilab Kiosk. Revised 05/22/2018. Load your sample:

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Increasing the productivity of ICP-OES with the Thermo Scientific Qtegra ISDS Software

Long term stability tests of INO RPC prototypes

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Manual of SF6 Comprehensive Tester

FPG8601 Force Balanced Piston Gauge

PHOENIX L300i Best-in-class Helium Leak Detectors

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

Quadruple mass spectrometers (transducer type)

APPLICATION NOTE. GC Integrated Permeation Device

System Overview. TCD Detector temperature setpoint Regulator

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Additel 761 Automated Pressure Calibrators Selection Guide

UltiMate 3000 Viper Capillary Kits for Intelligent LC (LCi) System Solutions

AKTA pure 25 New Owner s Intro

Additel 761 Automated Pressure Calibrators

GCMSD-Headspace Analysis SOP

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Mass Flow Controllers

Thermo K-Alpha XPS Standard Operating Procedure

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

Pool and Spa. Water Testing

This test shall be carried out on all vehicles equipped with open type traction batteries.

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

Best Practice for Identifying Leaks in GC and GC/MS Systems

Design Features. General Description

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Gradients in ion chromatography. Optimal separation with shorter analysis time

M/s. Thermo fisher Scientific

VIC offers a variety of Calibrated Gas Leaks

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300

Mass Spec will not Autotune

Agilent 5110 ICP-OES

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

Transcription:

Indian Institute of Technology Kanpur Environmental Engineering and Management Department of Civil Engineering Professor Vinod Tare Phones:+91-0512-2597791,7792 Email: vinod@iitk.ac.in Post Office: IIT Kanpur 208016 _ Enquiry No: CE/EEM/2013/NC/IC-ICP-MS/5 Dated: October 17, 2013 Last Date: November 4, 2013 Sub: Call for quotation for IC-ICP-MS System Sealed Quotation(s) are invited (in foreign currency on CIF New Delhi basis) for the purchase of IC-ICP-MS 1 (One) No quantity. It must fulfill following technical details All components of the IC-ICP-MS system must be seamlessly integrated through a single PC-controlled software that auto-triggers component routines. Minimum required specifications for the ICP-MS and IC systems are shown below. ICP-MS System specification 1. ICP-MS sample introduction system A. Peristaltic pump: A multi channel (>10 rollers) which can support variable flow rate, with at least four channels B. Nebulizer: It must include a PFA nebulizer as standard having high resistance to acid. C. Spray Chamber: Temperature controlled quartz spray chamber with efficient peltier cooling (-10 o C to + 20 o C). Should be able to handle up to 0.2% of total dissolved solids in the sample. 2. ICP Torch A. ICP Torch: Quartz torch with 2.5 mm or smaller ID injector. C. Precision torch adjustment: Complete computer controlled adjustment 1

of the position of three torch in X, Y and Z directions with independent movements in the three directions. Automatic alignment option. D. Precision gas control: Three computer controlled mass flow controllers for controlling all the plasma gas lines precisely (nebulizer, plasma and auxiliary gas flow). 3. RF Power source for ICP torch: A. RF Generator (source): ~27 MHz frequency, solid state power source, crystal controlled. B. Forward Power: 500-1600 Watts variable. C. Plasma shutdown: Automatic shutdown of the plasma by the system after completion of analysis. 4. Interface High matrix tolerance interface with high purity nickel cone shaving apertures of at least samples cone ~1.1mm. Skimmer cone ~0.5 mm diameter. A set of platinum cones should also be supplied as standard accessory. 5. Collision reaction cell The system must have the state-of-the-art technology for analysis in both, collision and reaction modes. 6. Ion Optics Ion optics should have excellent focusing with 90 o deflection system to analyzer and detector for elimination of photons and neutrals. Background noise should be less than < 1cps in all modes. 7. Quadrupole mass analysis A. RF generator: Should be 2 MHz or higher The system should have the facility for overcoming the 1ow mass based interferences. B. Vacuum system: Should have rotary pump and turbo molecular pump with split flow for extremely high gas throughput. Vacuum should be: Better than 1x10-5 mbar in open valve condition and shall be better than 5x10-5 mbar in closed valve condition. 2

C. Quadrupole material: made of molybdenum or stainless steel rods with RF pre-filters. Mass range: (5-285) amu. Scan rate: 5000 amu/sec D. Resolution: Computer controlled settings for quadrupole resolution adjustments are to be demonstrated. The best possible quadrupole resolution should be separately indicated in the offer. 8. Detector Ion detection with electron multiplier shall ensure better than 9 orders of linear dynamic range using simultaneous analog/pulse counting. It shall be possible to measure major and minor concentrations in a single analytical run. Should have over range protection and fully automated detector cross calibration with good linearity. The detector shall be easily replaceable by the user. Both the analog and pulse counting modes should be protected against overload. Minimum dwell time100 µs in both pulse counting and analog mode. Detector should have a minimum life of 3 years without replacement. 9. Performance criteria A. Sensitivity Li/Be 50.0xl0 6 cps/ppm Co 60.0 xi0 6 cps/ppm InorY 200.0x10 6 cps/ppm U/TI/Th 110.0x106cps/ppm. B. Signal stability: Short term stability (%SD), less than 3% (over 10 minutes) and Long time stability (%SD) less than 3% (over 2 hours) have to be demonstrated. C. Oxide ratio: CeO/Ce (%) < 3 D. Doubly charged ratio (%): Ba 2± /Ba(%) < 3 E. Isotope ratio precision: (%SD) Agl07/Agl09 < 0.1 F. Mass Stability: 0.025amu/Day or better 3

10. System control and data acquisition The system should perform auto optimization of plasma parameters like plasma power, plasma gas flow, etc. The instrument software shall allow auto-tuning to enable the instrument to be used with the consistent and reproducible day to day performance independent of the operator. A. Acquisition mode: Peak jumping, scanning, Time resolved analysis, Isotope Ratio measurements using integral software. B. Analysis mode: Shall allow for semi quantitative analysis, external calibration and internal standard addition methods for fully quantitative analysis, allowing parts per trillion level analysis and isotope ratio measurements with precision better than 0.2%. C. Report Generation: Output results formatted in mixed concentration units e.g. ppt, ppb, ppm etc. D. Quality control and software: a. Software for automated QA/QC during unattended operation. It must have all the features of CFR21 Part11 audit trials offered as standard. b. Off line data processing and exportability of data to other standard packages should be available. c. Matrix specific databases to provide preferred isotope selection should be available. Note: Master copies of all relevant software must be supplied. All instruction manuals and service manuals must be supplied along with the instrument. Latest PC along with Laser printer should be supplied at no extra cost. E. Warranty: The system should carry a warranty for at least 3 years from installation, against any kind of manufacturing defects and must include periodic servicing of the 4

instrument on-site. The warranty should b e a part of the total IC-ICP-MS system supply. a. Multi-element NIST traceable standard - 1No b. Fume exhaust for ICP-MS system 01 set c. Gas supply system to ICP-MS system 01 set The gas supply system is meant to provide required gases to the ICP-MS system at specific purity, pressure and flow rates. Such a gas supply system should include: i. Gas cylinder for Plasma formation - Argon ii. Gas cylinder for Collision cell gases - Helium iii. 2 stage Gas pressure regulators for each cylinder iv. Gas purification panels v. Gas supply manifold for switching gas cylinder vi. SS tubing d. UPS system with 1Hour battery backup 1 Set e. PC with necessary software for controlling the IC-ICP-MS system f. Color Laser printer at no extra cost - 01No g. Water recirculation chiller for ICPMS system as standard accessory -1 h. HF Kit 01 No IC (Ion Chromatograph) Specifications 1. The system quoted should include following modules for speciation of As, Cr, Hg, Sn, Fe, Se:- i. An appropriate Quaternary Gradient Pump with flow rates up to 10ml/min and compatible with Micro bore 2mm dia and standard bore analytical columns of 4 mm dia, Compatibility with capillary columns will be an added advantage. ii. Thermostatted Detector Chromatography housing model to accommodate injector, columns, switching valves in thermally controlled environment. iii. Polymeric columns for Anions and Cations, Gradient compatible iv. Chromatography control Software v. Automated sample preparation vi. Standards and Qualification kit vii. PC and Printer 5

2. Following are the details specification required for each module:- The complete flow path of the system modules should be nonmetallic PEEK based compatible for 0-14 ph & 100 % reverse phase organic solvent for analysis of Anions, and Cations. 1. QUATERNARY GRADIENT SOLVENT DELIVERY PUMP - 1No Non metallic PEEK based compatible for 0-14 ph & RP compatibility for 4 solvents gradient and as per the following specification a Flow rate Range 0.001-10 ml/min b Flow rate accuracy ± 0.1 at 1 ml/min c No. of mobile phase : Should form a gradient of 1-4 mobile d Pressure Range : 50-5000psi e Pressure Pulsation/Ripples : < 1 % without pulse dampner f Delay volume : < 500 µl g Seal wash : On-line automatic h Flow Precision : ±0.1%at 1ml/min. i Vacuum degasser : Built in 4 channels with gradient pump j Gradient Proportioning Accuracy : ±0.5 % at 2 ml/min k Gradient Proportioning Precision : ±0.5 % at 2ml/min ELUENT ORGANISER A separate mobile phase organizer should be provided to hold and mount 4 mobile phase bottles with Helium Sparging option must be available. The eluent organizer must be corrosion proof polypropylene. 3. COLOUMN FOR METAL IONS SPECIATION: a. Columns must be of polymeric Ion exchange for better efficiency and high loading capacity. All columns must be solvent compatible, non-metallic and non-corrodible components like Frits, preferably made of PEEK for analysis of Anions. b. Columns for Anions must have the separation capability for analysis of Anions & Cations. c. Columns must be 100 % solvent compatible and must withstand 0-14 ph. 6

4. CHROMATOGRAPHY SOFTWARE The Software should be capable to control the complete Ion Chromatography system through ICP-MS console. It should be able to configure any of the detectors available. Software should be compatible with the windows XP and higher operating systems. IC & ICP-MS should be controlled through a seamless integrated interface that auto-triggers component software. 4. SAMPLE PREPARATION: Appropriate sample preparation solid phase cartridges must be quoted and included in the system 5. STANDARDS FOR ANIONS AND CATIONS with the IQ/OQ/PQ qualification kit should be supplied for easy startup and qualification. Send sealed quotation(s) (Technical and financial quotes separate and clearly marked outside on the envelope) to the following address by 16:00 h on November 4, 2013: Dr Vinod Tare, Department of Civil Engineering, IIT Kanpur, KANPUR - 208016. Vinod Tare 7

8