ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

Similar documents
ProcessMaster FEP610 Electromagnetic flowmeter

ABB Instrumentation. Specifications. MagMaster Plus MFF Series Electromagnetic Sensors. MagMaster Plus bringing unsurpassed flowmetering performance

Electro-Magnetic Flowmeters Electromagnetic Sensor

C-Flow Coriolis Mass Flow Meters

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

ABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Level transmitter LT 100

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Ultrasonic level transmitter and indicator

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

TH-1800-T TRX-700-CNG Converter

High-performance submersible pressure transmitter For level measurement Model LH-10

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

Mass Flow Controller (MFC) for Gases

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

High-performance submersible pressure transmitter For level measurement Model LH-10

SonoMeter 30 Energy Meters

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

Liquid level instruments BM 24 /BM 51

S261 Remote seals with capillary tube

Torque Tube TB300 Digital Transmitters

Precision pressure sensor Basic version Model CPT6020

Expert Hydrostatic Level Transmitters

ATM.ECO - Analog Pressure Transmitter

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

For Multi-Parameter Meters see mvx

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

T EK-COR 1100A Coriolis Mass Flowmeter

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Online data sheet FLOWSIC30 GAS FLOW METERS

analytical bulk flow distance FLOW level pressure temperature industrial communication

High-speed pressure sensor Model CPT6140

Gas density monitor With integrated transmitter Model GDM-100-TI

Features. Description

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

ProcessMaster FEP610, HygienicMaster FEH610 Electromagnetic flowmeter

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

For Multi-Parameter Meters see mvx

Service Calibration are you doing it properly?

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

High-performance submersible pressure transmitter For level measurement Model LH-20

Pro-V Multivariable Flowmeter

9700 Transmitter Submersible hydrostatic level transmitter

Micro Motion H-Series Hygienic Coriolis Flow and Density Meters

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Orifice Plate Flow Meter

TECHNICAL DESCRIPTION

Turbine Flowmeters for Gas Applications

Mass Flow Meter (MFM) for gases

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

Mass Flow Controller (MFC) for Gases

780S Ultra High Purity Series

Thermal Energy Flowmeter Model KEC. Application Range. Special Features

High-performance submersible pressure transmitter For level measurement Model LH-20

Model 601CV. Mass Flow Controller. Product Features:

Mass Flow Meter (MFM) for Gases

Programmable Submersible Level Transmitters

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Turbine Flowmeters for Gas Applications (Metric)

Measurement & Analytics Wet gas monitoring

Pressure transmitter PASCAL Ci4

Turbine Flowmeters for Gas Applications

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Wafer type. the product

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Prewired position switches FA series

Design Features. General Description

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Flow Measurement SITRANS F C

Electronic Turbine Meter TERZ 94

Programmable pressure and temperature transmitters PTM/RS485

Over 20,000 Strain Gage Target flowmeters installed since 1952.

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

Programmable pressure and temperature transmitters PTM/RS485

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

Process Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.

Pressure Measurement Single-range transmitters for general applications

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Transcription:

ABB MEASUREMENT & ANALYTICS DATA SHEET WaterMaster FEW530 Electromagnetic water meter

2 WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W530/FE T3 -E N RE V. A Measurement made easy Cost effective and superior alternative to mechanical meters Compact full-bore device in wafer design available in sizes DN50 to DN250 (2 to 10 in) Quick and compact installation fits ASME flanges (CL150) Bi-directional flow measurement No moving parts increased reliability Switch-mode power supply

WATERMASTER FEW530 ELECTROMAGNETIC WATER METER DS/FEW530/FET3-EN REV. A 3 Applications Building automation and related metering Irrigation, tube wells and abstraction Treated effluents Bulk water metering Ideal for water and waste water OEMs Setting the standard Designed specifically to target water applications, WaterMaster FEW530 sets new standards of reliability and low cost of ownership. Ground-breaking design guarantees long-term calibration stability, coupled with a wide range of wafer design sizes DN 50 to DN 250 (2 to 10 in). Class-leading flow performance Based on the proven electromagnetic principle, the WaterMaster FEW530 combines the best features of the technology to create a cost-effective alternative to conventional methods. The combination of sensors with linear magnetics, proven technology, signal processing and sensor drive results in stable performance and high turndown. Assured quality WaterMaster FEW530 is manufactured in accordance with international quality procedures (ISO 9001) and all flowmeters are calibrated on traceable calibration rigs to provide the enduser with complete quality assurance. A flow tube that is free of obstructions ensures reliability under demanding flow conditions and in the presence of solids (for example, sand, weeds and leaves) in the process. Comprehensive features A wide range of features and user benefits are built into this cost effective flowmeter including a graphical display with a four-key HMI for easy operation and totalizers to keep track of the volume of water flowing through the meter. Specification mechanical Wetted parts Lining Elastomer (EPDM rubber) Measurement electrode Hastelloy C4 Grounding plate Stainless steel (SS316) Flowmeter sensor Housing DN50 to DN250 (2 to 10 in) Carbon steel sheet metal, painted, paint coat 80 µm thick, RAL 9002 Terminal box Cast aluminium, painted, 80 µm thick, light gray, RAL 9002 Meter tube Stainless steel Cable gland Polyamide M20 IP rating (according to EN 60529) IP 67 Temperature rating Ambient temperature 20 to 60 C ( 4 to 140 F) Storage temperature 20 to 70 C ( 4 to 158 F) Process temperature 0 to 80 C (32 to 176 F) Measuring medium conductivity 50 µs/cm Maximum measuring error (impulse output) Advanced calibration ±0.4 % of measured value % 2.5 2 1.5 Y 1 0.5 0 0 20 40 60 80 100 Q /QmaxDN 0 2 4 6 8 10 v[m/s] X Y = Accuracy (± of measured value in %) X = Flow velocity v in m/s, Q / QmaxDN [%] QmaxDN: see table on page 4 Advanced version error ±0.4 % of measured value ±0.02 % QmaxDN

4 WATERMASTER FEW530 ELECTROMAGNETIC WATER METER DS/FEW530/FET3-EN REV. A Specification mechanical Flowmeter sizes, flow range Bore DN in Min. flow range end value 0.02 x QmaxDN ( 0.2 m/s) 50 2 1.2 m 3 /h (5.28 US gal/min) 80 3 3.6 m 3 /h (15.9 US gal/min) 100 4 4.8 m 3 /h (21.1 US gal/min) 125 5 8.4 m 3 /h (37 US gal/min) 150 6 12 m 3 /h (52.8 US gal/min) 200 8 21.6 m 3 /h (95.1 US gal/min) 250 10 36 m 3 /h (159 US gal/min) QmaxDN 0 to 10 m/s 60 m 3 /h (264 US gal/min) 180 m 3 /h (793 US gal/min) 240 m 3 /h (1057 US gal/min) 420 m 3 /h (1849 US gal/min) 600 m 3 /h (2642 US gal/min) 1080 m 3 /h (4755 US gal/min) 1800 m 3 /h (7925 US gal/min) Max. flow range end value 2 x QmaxDN ( 20 m/s) 120 m 3 /h (528 US gal/min) 360 m 3 /h (1585 US gal/min) 480 m 3 /h (2113 US gal/min) 840 m 3 /h (3698 US gal/min) 1200 m 3 /h (5283 US gal/min) 2160 m 3 /h (9510 US gal/min) 3600 m 3 /h (15850 US gal/min) Specification electrical Output Current output 4 to 20 ma DC Digital output 2 (configurable for pulse and alarm) Human machine interface (HMI) Graphic LCD, four-key navigation Power supply 24 V AC and DC, 110 to 220 V AC, 50/60 Hz Transmitter configuration Integral to sensor Remote version available as option Signal cable (for remote versions only) Length up to 50 m (165 ft)

WATERMASTER FEW530 ELECTROMAGNETIC WATER METER DS/FEW530/FET3-EN REV. A 5 Dimensions DN 50 to 100 (2 to 4 in) 77.8(3.06) 105(4.13) 98(3.84) 100(3.94) C D H O 201(7.91) 84.5(3.33) 74.2(2.92) F 35(1.38) T G L Meter size DN50 (2 in) DN80 (3 in) DN100 (4 in) 100 (3.93) 132 (5.19) 170 (6.7) Dimensions in mm (in) Weight in kg (lbs) D C L F G O H T Integral Remote 50 (1.96) 66 (2.59) 85 (3.34) 88 (3.46) 126 (4.96) 156 (6.14) 291 (11.45) 317.5 (12.5) 331 (13.03) 164.2 (6.46) 190 (7.48) 204 (8.03) 341 (13.42) 383.5 (15.09) 416 (16.37) 154.5 (6.08) 197 (7.75) 229.5 (9.05) 214.2 (8.43) 256.7 (10.1) 289.2 (11.38) 8.12 (17.9) 9.93 (21.89) 12.66 (27.9) 6.08 (13.4) 7.44 (16.4) 10.16 (22.39)

6 WATERMASTER FEW530 ELECTROMAGNETIC WATER METER DS/FEW530/FET3-EN REV. A Dimensions DN 125 to 250 (5 to 10 in) 77.8 (3.06) 105(4.13) 98(3.86) ø100 (3.94) D O C H 201 (7.91) 84.5(3.33) F 74.2(2.92) 35(1.38) G T L Meter size DN125 (5 in) DN150 (6 in) DN200 (8 in) DN250 (10 in) 193 (7.6) 218 (8.58) 275 (10.82) 335.5 (13.2) Dimensions in mm (in) Weight in kg (lbs) D C L F G O H T Integral Remote 108.5 (4.27) 119.5 (4.7) 148 (5.82) 178.5 (7.02) 156 (6.14) 171 (6.73) 206 (8.11) 226 (8.89) 341 (13.42) 361 (14.21) 376 (14.8) 421 (16.57) 214 (8.43) 234 (9.21) 249 (9.81) 294 (11.58) 422.5 (16.63) 480.5 (18.91) 514 (20.62) 599.5 (23.6) 236 (9.29) 294 (11.57) 337.5 (13.28) 413 (16.25) 295.7 (11.64) 353.7 (13.92) 397.2 (15.63) 472.7 (18.61) 13.7 (30.2) 15.15 (33.4) 17.8 (39.24) 21.5 (47.39) 11.5 (23.35) 12.8 (28.21) 15.6 (34.39) 18.7 (41.22)

WATERMASTER FEW530 ELECTROMAGNETIC WATER METER DS/FEW530/FET3-EN REV. A 7 Electrical connections FET3 A = transmitter, B = sensor Power supply connections AC power supply Terminal L N PE DC power supply Function Live / Phase Neutral Protective earth (PE) Terminal Function 1+ + 2 PE Protective earth (PE) Sensor cable terminal connections (remote mount versions only) Terminal Function Cable color M1 Magnet coil Brown M2 Magnet coil Red D1 Data line Orange D2 Data line Yellow SE Shield E1 Signal line Violet 1S Shield for E1 E2 Signal line Blue 2S Shield for E2 3 Measurement potential Green Output connections Terminal Function 31 / 32 Current / HART output Current output is available in 'active' or 'passive' mode 51 / 52 Digital output DO1 active / passive May be configured locally as 'pulse output' (factory default) or 'digital output' 81 / 82 Digital input / contact input May be configured locally as 'external output switch-off', 'external totalizer reset', 'external totalizer stop' or 'other' 41 / 42 Digital output DO2 passive May be configured locally as 'pulse output' or 'digital output' (factory default). Flow direction signalling.

8 WATERMASTER FEW530 ELECTROMAGNETIC WATER METER DS/FEW530/FET3-EN REV. A Ordering information WaterMaster wafer flowmeter integral transmitter FEW531.Y0.V4.F.0050.W1.E2.U.1.D.0.D.70.A.2.G0.B.FET3+3KXF271100U0084-1 FEW531.Y0.V4.F.0080.W1.E2.U.1.D.0.D.70.A.2.G0.B.FET3+3KXF271100U0084-2 FEW531.Y0.V4.F.0100.W1.E2.U.1.D.0.D.70.A.2.G0.B.FET3+3KXF271100U0084-3 FEW531.Y0.V4.F.0125.W1.E2.U.1.D.0.D.70.A.2.G0.B.FET3+3KXF271100U0084-4 FEW531.Y0.V4.F.0150.W1.E2.U.1.D.0.D.70.A.2.G0.B.FET3+3KXF271100U0084-5 FEW531.Y0.V4.F.0200.W1.E2.U.1.D.0.D.70.A.2.G0.B.FET3+3KXF271100U0084-6 FEW531.Y0.V4.F.0250.W1.E2.U.1.D.0.D.70.A.2.G0.B.FET3+3KXF271100U0084-7 WaterMaster wafer flowmeter remote transmitter FEW532.Y0.A2.K1.F.0050.W1.E2.U.1.D.0.D.70.A.2.G0.B.SC2.FET3+3KXF271100U0084-1 FEW532.Y0.A2.K1.F.0080.W1.E2.U.1.D.0.D.70.A.2.G0.B.SC2.FET3+3KXF271100U0084-2 FEW532.Y0.A2.K1.F.0100.W1.E2.U.1.D.0.D.70.A.2.G0.B.SC2.FET3+3KXF271100U0084-3 FEW532.Y0.A2.K1.F.0125.W1.E2.U.1.D.0.D.70.A.2.G0.B.SC2.FET3+3KXF271100U0084-4 FEW532.Y0.A2.K1.F.0150.W1.E2.U.1.D.0.D.70.A.2.G0.B.SC2.FET3+3KXF271100U0084-5 FEW532.Y0.A2.K1.F.0200.W1.E2.U.1.D.0.D.70.A.2.G0.B.SC2.FET3+3KXF271100U0084-6 FEW532.Y0.A2.K1.F.0250.W1.E2.U.1.D.0.D.70.A.2.G0.B.SC2.FET3+3KXF271100U0084-7

WATERMASTER FEW530 ELECTROMAGNETIC WATER METER DS/FEW530/FET3-EN REV. A 9 Accessories Description Part number High accuracy FET3 FET3 * Sensor installation kits DN 50 (2 in) 3KXF271100U0084-1 DN 80 (3 in) 3KXF271100U0084-2 DN 100 (4 in) 3KXF271100U0084-3 DN 125 (5 in) 3KXF271100U0084-4 DN 150 (6 in) 3KXF271100U0084-5 DN 200 (8 in) 3KXF271100U0084-6 DN 250 (10 in) 3KXF271100U0084-7 Earth contact flange, 316 stainless steel 50 mm (2 in) 3KXF271100U0086-1 80 mm (3 in) 3KXF271100U0086-2 100 mm (4 in) 3KXF271100U0086-3 125 mm (5 in) 3KXF271100U0086-4 150 mm (6 in) 3KXF271100U0086-5 Earth contact ring, 316 stainless steel 200 mm (8 in) 3KXF271100U0086-6 250 mm (10 in) 3KXF271100U0086-7 * Additional ordering code (mandatory) FET3

10 WATERMASTER FEW530 ELECTROMAGNETIC WATER METER DS/FEW530/FET3-EN REV. A Notes Sales Service Software

WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W53 0/FE T3 -E N RE V. A 11

ABB Limited Measurement & Analytics Peenya Industrial Area Bangalore-560058 India Toll free: 1800 420 0707 International: +91 80 67143000 Email: contact.center@in.abb.com abb.com/measurement/flow We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2018 ABB. All rights reserved. DS/FEW530/FET3-EN Rev. A 05.2018