PRO SINK -R 1 and 2. Dilution system CONTENTS

Similar documents
Ultra Concentrate Dispensing System

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Pressure Dump Valve Service Kit for Series 3000 Units

Aquor House Hydrant V2

Pocket Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

User's Manual. MixRite TF 10. Edition 05.08

Pressure Dump Valve Service Kit for Series 2300 Units

Bermad Pressure Reducing. Model: 42T

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

VRS Assembly & Operating Instructions

Instructions for Use

Air Operated Hydraulic Pumping Systems to 50,000 psi

ABRASIVE REGULATOR II

ABRASIVE REGULATOR II

Installation of Your SprayMaster System

553 Series.

Air Saving Valve. Pressure Valve Flow Valve

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Installation Instructions

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

DS05C,D,G Dial Set Pressure Regulating Valves

RD(H)20/25 Pressure-Reducing Regulator User Manual

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

TECHNICAL DATA. Q= Cv S

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

Scald Protection Three-Way Thermostatic Mixing Valve

INSTALLATION GUIDELINES

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

INSTALLATION GUIDELINES

Geotech 1.66 Auto-Reclaimer Installation and Operation

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual

APPS-160 Gen 2 User Manual

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

LRS(H)4 Pressure-Reducing Regulator User Manual

OPERATION MANUAL obl1 OPERATION MANUAL

DS06D,G Dial Set Pressure Regulating Valve

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

Hydraulic Punch Drivers

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

OWNER S TECHNICAL MANUAL

SCUBAPRO. Balanced Power Inflator

3/4 MPT w/ MHT Flush & Cap (80 psi) (A2)

TECHNICAL DATA. Q = C v P S

GREIG FILTERS, INC. OPERATION MANUAL

Geotech 1.66 Auto-Reclaimer

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

1020 Industrial Drive, Orlinda, TN fax

SINORIX Valve Reconditioning

Easy Nest Kits. Installation Suggestions

Model: 43T. Bermad Pressure Relief Valve

OWNER S MANUAL SUCTION GUN SG-300

Scald Protection 3-Way Thermostatic Mixing Valve

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

D05 Pressure Regulating Valves

Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V

Model VR6 System. Installation, Operation & Maintenance

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

HGC-200 Hydro Gas Chlorinator

PANACEA P200 STAINLESS STEEL USER MANUAL

PANACEA P100 LOW PRESSURE USER MANUAL

ASSEMBLY & USE MANUAL

40K TLX Nozzles 40K TLX

3:1 High Ratio Oil Pump W. Extn. Kit

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Chemical Injection Technologies Installation/Service Bulletin

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Booster Pump PB4-60 Replacement Kits

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

Pneumatic Powered - Plunger Pumps

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Helium-Oxygen Blender

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Techcon Systems TS1258 Pressure Pot

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual STOP!

MANUAL. Sesame. Thermoplastic Tank Technologies

Installation Instructions

Combination Air Valve

CSA Sample Draw Aspirator Adapter Operator s Manual

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

UsER manual for Watersens ph -REDOX

GAS CONVERSION KIT Installation Instructions Range/Rangetop

Rapidmain Installation Guide

Standard and Low-Flow Metric Powder Feed Pumps

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Geotech 3.5 Reclaimer Installation and Operation Manual

Transcription:

PRO SINK -R 1 and 2 Dilution system CONTENTS 1.0 Product description 2 2.0 Warnings.. 3 3.0 Installation procedure 4 4.0 Plumbing connections 4 5.0 Technical features.. 5 6.0 Maintenance... 6 7.0 Troubleshooting......6 8.0 Remove the SS facing...8 9.0 Changing the water inlet direction 8 10.0 Changing a ball valve.....9 11.0 Reassembling the prosink-r.9

1.0 PRODUCTS DESCRIPTION PROSINK-R 1 PRODUCT 1GPM (4L/MIN) / 4GPM (16L/MIN) FGAP (PSK1F04UN000 PSK1F16UN000) PROSINK-R 2 PRODUCTS 1GPM (4L/MIN) / 4GPM (16L/MIN)FGAP (PSK2F04UN000 PSK2F16UN000) PROSINK-R 1PRODUCT 1GPM (4L/MIN) / 4GPM (16L/MIN) AGAP (PSK1A04UN000 PSK1A16UN000) PROSINK-R 2 PRODUCTS 1GPM (4L/MIN) / 4GPM (16L/MIN) AGAP (PSK2A04UN000 PSK2A16UN000) 1 Satin-finish STAINLESS STEEL guard 2 Activation knob 3 F-Gap backflow preventer 4 Venturi 5 ¾ GHT ring nut Connection for bottle ( S ) filling hose -1GPM (4L/MIN) 6 Connection for outlet hose (15,2X22 mm) - 4GPM (16L/MIN) 7 Connection for pick up hose ¼ ID 3 / 8 OD (6x9 mm) ProSink-R Cod. 0000137876 rev. 1.0 EN 2

2.0 WARNINGS I READ THE FOLLOWING WARNINGS BEFORE PROCEEDING TO INSTALL OR MAINTENANCE WORK ON THE DILUTION UNIT DO Optimum water supply pressure is 40 PSI (2.75 bar). Max. 100 PS (6.9 bar); Min. 20 PSI (1.4 bar) Max. temperature 140 F (60 C) Fittings have been tested for use with the most common liquid detergents mixed with water. Check that the detergent used is compatible with brass and polypropylene. Install the unit near a connection point for the water supply and above the sink in such a way that the activation knob is accessible. Mount the unit to facilitate cleaning and so the plumbing fittings are accessible for replacing metering tips and routine maintenance. I Check the model to accurately determine the dosage calibration references indicated in this manual. N WARNING: Always follow the necessary safety procedures, including the use of adequate protection for the eyes, face, hands, and clothing. N WARNING: When installing or carrying out maintenance on this equipment, always disconnect it from the water supply. Ü Ü The supplier is constantly striving to perfect all its products and we therefore reserve the right to make changes at any time without notice. Failure to follow these safety precautions could result in damage to adjacent property or injury to people, and possibly damaging the equipment or compromising its operation. ASSE 1055B APPROVED CHEMICAL DISPENSING SYSTEM! TO PREVENT SIPHONING AND TO COMPLY WITH ASME A112.1.2, INSTALL THE PROSINK WITH THE END OF THE OUTLET TUBE A MINIMUM 4 ABOVE THE FLOOD LEVEL OF THE SINK OR OTHER FIXED CONTAINER. ProSink-R Cod. 0000137876 rev. 1.0 EN 3

3.0 INSTALLATION PROCEDURE Picture Layout of wall mounting 1.1 Position the Pro Sink-R on a vertical wall and check that it is easy to operate and that it is close to a connection point for the water supply. 1.2 Mark the position of the slots on the wall as a guide for drilling. 1.3 Remove the guard from the wall and check that the drilling marks can be clearly seen. 1.4 Drill two ¼ (6 mm) diameter holes at the points marked on the wall. 1.5 Put the anchors supplied into these holes and screw in the screws without completely tightening 1.6 Mount the unit and secure tightly. 4.0 PLUMBING CONNECTIONS Note: The water supply connection is a standard ¾ female swivel (GHT) 1.1 Insert the screened washer with the filter as illustrated above. 1.2 Connect the water supply hose to the female swivel on the top right of the Pro Sink-R. 1.3 Turn the swivel until the washer is securely seated onto the male threads of the supply hose. 1.4 Insert the calibration nozzle chosen into the barb fitting and then secure the elbow connection. 1.5 Install the outlet hose (15,2X22 mm) and pick up hose ( 1 / 4 ID 3 / 8 OD 6x9mm). 1.6 Position the delivery hose above the sink. 1.7 Install the weight onto the end of the pick up tube, install the foot filter and slide the weight until flush with the foot filter. 1.8 Place the pick up tube into the product container. I Warning: The difference in height between the bottom of the product container and the Pro Sink-R nozzle connector must not exceed 6.6 ft (2 m) I Warning: The product must be below the Pro Sink-R to prevent siphoning. I Warning: The end of the delivery hose must be above the level of the product to be mixed to prevent siphoning. I Warning: The outlet tubes must be installed with flow restrictor rings ProSink-R Cod. 0000137876 rev. 1.0 EN 4

5.0 TECHNICAL FEATURES The ProSink-R provides the following flow rates (the values shown in table 1 only apply when mixing one product at a time): Dynamic pressure upstream of the PROSINK-R Flex-Gap 1 GPM 14.5 PSI (1 bar) 29 PSI (2 bar) 45.5 PSI (3 bar) Flow Rate in GPM 0.7 1.3 1.7 Flow Rate in l/min 2.6 5.0 6.3 4 GPM 14.5 PSI (1 bar) 29 PSI (2 bar) 45.5 PSI (3 bar) Flow Rate in GPM 1.6 2.7 3.4 Flow Rate in l/min 6.0 10.4 13.0 Table 1 I WARNING: OPENING BOTH DOSING TAPS AT THE SAME TIME LEADS TO A SLIGHT REDUCTION IN THE FLOW RATE AND RESULTS IN CHANGES IN DILUTION RATE. The degree of dilution required can be obtained by using one of the 15 calibrated metering tips supplied. The nozzles are colors coded as below (table 2). The dilution ratio refer to the dynamic pressure of 40 PSI (2,76bar) with water thin products. 1 GPM Model 4 lt/min Flex-Gap 4 GPM Model 16 lt/min Tip color Diam eter inch Oz/Gal gr/lt % Ratio Oz/Gal gr/lt % Ratio No tip \ 41,3 339,0 33,9 2,9 :1 22,1 181,2 18,1 5,5 :1 Grey 0,128 40,2 330,3 33,0 3,0 :1 21,8 178,8 17,9 5,6 :1 Black 0,1 38,9 319,6 32,0 3,1 :1 20,4 168,0 16,8 6,0 :1 Beige 0,07 29,4 241,9 24,2 4,1 :1 15,1 124,0 12,4 8,1 :1 Red 0,052 18,7 153,4 15,3 6,5 :1 9,4 77,4 7,7 13 :1 STANDARD METERING TIP White 0,043 12,6 103,8 10,4 9,6 :1 6,1 50,1 5,0 20 :1 Blue 0,04 10,7 87,8 8,8 11 :1 5,2 42,7 4,3 23 :1 Tan 0,035 8,4 68,8 6,9 15 :1 4,3 35,3 3,5 28 :1 Green 0,028 5,2 42,8 4,3 23 :1 2,9 23,8 2,4 42 :1 Orange 0,025 3,8 31,6 3,2 32 :1 2,0 16,4 1,6 61 :1 Brown 0,023 3,2 26,3 2,6 38 :1 1,7 14,2 1,4 70 :1 Yellow 0,02 3,0 24,4 2,4 41 :1 1,5 12,1 1,2 83 :1 Aqua 0,018 2,9 24,2 2,4 41 :1 1,1 9,2 0,9 109 :1 Purple 0,014 1,0 8,3 0,8 120 :1 0,9 7,0 0,7 143 :1 Pink 0,01 0,8 6,3 0,6 159 :1 0,2 1,8 0,2 556 :1 Clear \ No hole No hole Lime 0,009 0,45 3,70 0,37 270 :1 0,21 1,70 0,12 588 :1 ULTRALEAN TIP Burgundy 0,008 0,41 3,40 0,34 294 :1 0,18 1,50 0,11 667 :1 Pumpkin 0,007 0,35 2,90 0,29 345 :1 0,17 1,40 0,15 714 :1 Copper 0,006 0,12 1,00 0,10 1000 :1 0,06 0,50 0,07 2000 :1 Table 2 The dilution values given in this table are measured at free discharge water supply condition flow rate of 7.92GPM (30 l/min) and supply static pressure of 40 PSI (2.76 bar), with a suction height of 5 feet (1,5 m). ProSink-R Cod. 0000137876 rev. 1.0 EN 5

The ProSink-R provides the following flow rates (the values shown in table 3 only apply when mixing one product at a time): Dynamic pressure upstream of the PROSINK-R Air-Gap 1 GPM 14.5 PSI (1 bar) 29 PSI (2 bar) 45.5 PSI (3 bar) Flow Rate in GPM 0.7 1.2 1.5 Flow Rate in l/min 2.9 4.6 5.9 4 GPM 14.5 PSI (1 bar) 29 PSI (2 bar) 45.5 PSI (3 bar) Flow Rate in GPM 2.1 2.9 3.5 Flow Rate in l/min 8.0 11.2 13.4 Table 3 I WARNING: OPENING BOTH DOSING TAPS AT THE SAME TIME LEADS TO A SLIGHT REDUCTION IN THE FLOW RATE AND RESULTS IN CHANGES IN DILUTION RATE. The degree of dilution required can be obtained by using one of the 15 calibrated metering tips supplied. The nozzles are colors coded as below (table 4). The dilution ratio refer to the dynamic pressure of 40 PSI (2,76bar) with water thin products. STANDARD METERING TIP Tip color Diam eter inch Oz/Gal gr/lt % Ratio Oz/Gal gr/lt % No tip \ 37,2 305,5 30,6 3,27 :1 16,1 132,2 13,2 7,56 :1 Grey 0,128 36,7 301,7 30,2 3,31 :1 16,0 131,1 13,1 7,63 :1 Black 0,1 36,6 300,8 30,1 3,32 :1 15,9 130,4 13,0 7,67 :1 Beige 0,07 30,0 246,1 24,6 4,1 :1 13,2 108,8 10,9 9,2 :1 Red 0,052 20,8 171,3 17,1 5,8 :1 8,9 73,3 7,3 14 :1 White 0,043 14,1 115,7 11,6 8,6 :1 6,0 48,9 4,9 20 :1 Blue 0,04 12,3 101,1 10,1 9,9 :1 5,0 41,0 4,1 24 :1 Tan 0,035 9,3 76,4 7,6 13 :1 4,1 34,0 3,4 29 :1 Green 0,028 7,0 57,8 5,8 17 :1 2,6 21,5 2,2 47 :1 Orange 0,025 4,6 38,0 3,8 26 :1 2,0 16,3 1,6 62 :1 Brown 0,023 4,2 34,4 3,4 29 :1 1,8 14,8 1,5 68 :1 Yellow 0,02 3,3 27,1 2,7 37 :1 1,3 11,0 1,1 91 :1 Aqua 0,018 2,4 19,4 1,9 52 :1 1,1 9,0 0,9 111 :1 Purple 0,014 1,4 11,7 1,2 85 :1 0,6 5,3 0,5 189 :1 Pink 0,01 0,7 6,0 0,6 167 :1 0,6 4,8 0,5 208 :1 Clear \ 1 GPM Model 4 lt/min No hole Air-Gap 4 GPM Model 16 lt/min No hole Ratio Lime 0,009 0,56 4,60 0,06 217 :1 0,21 1,70 0,02 588 :1 ULTRALEAN TIP Burgundy 0,008 0,40 3,30 0,04 303 :1 0,18 1,50 0,02 667 :1 Pumpkin 0,007 0,37 3,00 0,04 333 :1 0,16 1,30 0,02 769 :1 Copper 0,006 0,18 1,50 0,02 667 :1 0,07 0,60 0,01 1667 :1 Table 4 The dilution values given in this table are measured at free discharge water supply condition flow rate of 7.92GPM (30 l/min) and supply static pressure of 40 PSI (2.76 bar), with a suction height of 5 feet (1,5 m). ProSink-R Cod. 0000137876 rev. 1.0 EN 6

The values given in the table should be considered as close approximations, as actual dilution rate depends on variables such as water pressure, product viscosity, and the temperature of the water supply. For improved accuracy, the calibration can be verified as follows: 1.1 Fill a graduated cylinder with the concentrated product. 1.2 Using the above chart, select and insert the tip closest to the desired dilution ratio. 1.3 Insert the pick up hose into the graduated cylinder. 1.4 Put the outlet tube into a sink and open the tap. Draw up the product until the pick up tube is completely filled. 1.5 Mark the level of the product in the graduated container. 1.6 Switch the tap off and insert the delivery hose in a 1 gallon (or 1 liter) container. 1.7 Switch the tap on again until the 1 gallon (or 1 liter) container is completely full. 1.8 Switch the tap off and read the quantity of product in the graduated container. 1.9 The difference in the product levels for points 1.5 and 1.8 indicates the amount of product mixed per gallon (or liter). A nozzle is also provided that has a transparent colored tip without any hole that can be drilled to obtain a customized degree of dilution. 6.0 MAINTENANCE 1.1 Periodically check for buildup or debris foot filter. 1.2 Periodically check and if necessary, clean the washer filter in the GHT ring nut. 1.3 Periodically remove any lime build-up. To clean the Venturi properly replace the product to be mixed with a suitably diluted anti lime product and turn the tap to draw the product through the system. 7.0 TROUBLESHOOTING PROBLEM CAUSE REMEDY No flow No water supply Open the water supply connection The foot filter is clogged Clean or replace the filter The calibration nozzle is clogged Clean or replace the nozzle A minimum pressure of 20 PSI (1.4 bar) Insufficient water supply pressure is required for correct functioning. The product is not The delivery hose flow restrictor Insert the delivery hose with the jet mixed ring is in the incorrect position breaker at the Venturi end. The product container is empty. Fill the container The pick up hose is not properly inserted in the nozzle holder. Push the pick up tube all the way into the tip holder, as far as the upper stop. Concentration too high The metering tip is not fitted or it is fitted badly Insert the tip in the tip holder properly ProSink-R Cod. 0000137876 rev. 1.0 EN 7

8.0 REMOVING THE SS FACING 1. Remove ProSink-R from wall and lay on flat surface. 2. Remove valve knobs and set tools aside. 3. Place thumbs on valve stems and lift from the underside of the facing. 4. Remove stainless steel facing and set aside. 9.0 CHANGING THE WATER INLET DIRECTION All manifold components snap together and are sealed with double O rings as pictured To change water flow direction simply rotate upper manifold and re-secure over ball valve O rings as pictured (note: Be sure to align the manifold properly to avoid displacing O Rings. ProSink-R Cod. 0000137876 rev. 1.0 EN 8

10.0 CHANGING A BALL VALVE Replace any component in minutes without the use of tools 11.0 REASSEMBLING THE PROSINK-R After reassembling manifold, first insert the inductor outlets through openings at the bottom of the stainless steel facing and line up the pegs with the holes in the manifold Snap the ProSink R back together, replace the knobs on the ball valves and re-install the Prosink-R on the wall ProSink-R Cod. 0000137876 rev. 1.0 EN 9