Similar documents
Cryogenic Materials Operating Procedure and Safety Requirements

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Standard Operating Procedure (SOP)

Laboratory Standard Operating Procedure: Cryogenic Liquids

Developing Safety Guidelines for Cryogenic Liquids.

Each cryogenic liquid has its own specific properties, but most cryogenic liquids can be placed into one of three groups:

Chem Bio Liquid Nitrogen Facility

Working with Cryogenic Liquids

Compressed Gas Properties. Introduction. Compressed Gas Properties. Definition of a Compressed Gas

EHS Laboratory Guidance: Cryogenic Material

Hazardous Substances Policy - Control Measures POLICY

Standard Operating Procedure

Compressed Gases STANDARD OPERATING PROCEDURE

School of Plant Biology - Liquid Nitrogen Induction

DUQUESNE UNIVERSITY. Liquid Nitrogen Safety

Automatic LN2 Fill Station Instructions

Lecture Demonstrations Safety Manual & New Staff Induction

B. Working with liquid nitrogen local rules when using the X-ray facility, room 5.20, Flowers building

Safe Handling & Use of Liquid Nitrogen and Other Cryogenic Gases

PURPOSE OF THE POLICY

CRYOGENIC LIQUID HANDLING STANDARD

Molecular Materials Research Center Beckman Institute California Institute of Technology

Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices. Unit Objectives. Pressure Vessels and Piping (1 of 2)

Lab-Specific Standard Operating Procedure (LSOP)- Pyrophoric Chemicals

Compressed Gases and Cryogens

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

LABORATORY SAFETY. A general overview

Standard Operating Procedure

Liquid Gas Cylinder (LGC)

Laboratory Standard Operating Procedure: Specimen Preservatives

EXPERIENCE WITH CRYOGENICS SAFETY, PROBLEMS AND SOLUTIONS

Compressed Gases Safety Program

Laboratory Standard Operating Procedure: Irritants

Instructions for Completing the UW-Madison Laboratory Chemical Hygiene Plan Template

STANDARD OPERATING PROCEDURES (SOP) FOR REPRODUCTIVE HAZARDS

LIQUID OXYGEN. General. Health Effects. Safety Considerations

Safe handling of cryogenic liquids

Australian Standard The storage and handling of non-flammable cryogenic and refrigerated liquids SWP055

THE UNIVERISTY OF NEWCASTLE - SCHOOL of BIOMEDICAL SCIENCES

Hydrogen Cyanide (HCN)

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

M3060 Handling Compressed Gas Cylinders Safely. Leader s Guide

Laboratory Standard Operating Procedure: Acutely Toxic Substances

Student Information & Laboratory Safety Contract

1. Chemical Product and Company Identification

TEMPLE UNIVERSITY A Commonwealth University Environmental Health & Radiation Safety (EHRS)

APPS-160 Gen 2 User Manual

Laboratory Standard Operating Procedure: Sensitizers

STANDARD OPERATING PROCEDURE (SOP): URETHANE

Chapter 2. Welding Safety Delmar, Cengage Learning

UCSC Laboratory Standard Operating Procedure (SOP) Compressed Gas Cylinder Change for MOCVD and CVD Systems

Hydrofluoric Acid SOP

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

SOP Standard Operating Procedure. Etching All Materials

Standard Operating Procedure

MANAGEMENT OF LIQUID NITROGEN

Leader s Guide ERI Safety Videos

Laboratory Standard Operating Procedure: Reproductive Toxins

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 022 MOD: 1st Issue Page: 1 of 8

Laboratory Safety Inspection Checklist

Safety rules must be followed

Laboratory Standard Operating Procedure: Carcinogens

Markus Hofer (Chair WHS committee) & Dianne Fisher (Safety Officer)

CRYOGENIC LIQUIDS AND THE SCIENTIFIC GLASSBLOWER. Michael D. Wheeler, Arizona State University Chair, A.S.G.S. Safety and Hazards Committee

Faculty/School: Pharmacy Initial Issue Date: Oct 2016

High School Safety Acknowledgment Form

Laboratory Safety Committee

Compressed Gas Cylinder Safety Program April 4, 2017

Type 131. Roller base. Information and Operating Instructions for Dewar Vessels Type 131 up to 135 boxed shaped KGW-ISOTHERM

Chemical Class Standard Operating Procedures

EHS-SWP-140. Safe Work Practice. Animal Projects with Chemicals. 1.0 Hazard Description

General Safety Rules

NUS Safety & Health Guidelines Procedure No: OSHE/SOP/GL/08

An area may be considered a confined space if it meets three criteria.

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

OWNER S MANUAL. Page: 1 of 8

Standard Operating Procedure Porosity Analyzer - The Micromeritics Tri-Star II (surface area) with Micrometrics VacPrep 061 (Sample Degas System)

SAFETY DATA SHEET V4 in accordance with Regulation (EC) 1907/2006 (REACH) amеnded with Commission Regulation(EU) 2015/830

SAFETY TRAINING LEAFLET 06 CARBON DIOXIDE

Standard Operating Procedure (SOP)

Hydrofluoric Acid. Syracuse University Laboratory Standard Operating Procedure. I. Purpose: Physical and Chemical Properties: Potential Hazards:

1. Cryogen Tanks. N2 Fill Tutorial for Vanderbilt Magnets. Contents: CSB NMR Facility

Standard Operating Procedure for Solvent use in EMAL

Technical Operating Instructions for Magnum Cutting Systems. for online instructions

Chemical Class Standard Operating Procedures. Pyrophoric Chemicals (PYR) & Water Reactive Chemicats (WRC) Diethylzinc

Schlenk Line. Standard Operating Procedure. Lab: Engineering Sciences Building 155. Department: Materials Science and Engineering. PI: Paul V.

Standard Operating Procedure (SOP) for (_Hydrpchloric Acid_)

Management Plan for Liquid Chlorine ISD #535

Liquid Oxygen- Helios & Helios Marathon A Guide for Patients in the Home

I. Subject: Compressed gas cylinders, regulators, and portable liquid systems.

UNH Department of Forensic Sciences

Section 1. Contact Information. Procedure Title: Procedure Author: Date of SOP Creation/Revision: Name of Responsible Person: Location of Procedure:

Open toed shoes, sandals, or shoes made of loosely woven material should not be worn in the laboratory.

Quebec Quebec Tel : Fax : MSDS: Methane, Oxygen in Nitrogen Mixture PRODUCT INFORMATION

KGW-ISOTHERM. Information and Operating Instructions for Dewar Vessels Type 26 to 29 B or B-E

Laboratory Safety Manual Prepared by RAEIN-Africa & Partners. Under the Implementation of The National Biosafety Framework Project for Swaziland

NEW MEXICO HIGHLANDS UNIVERSITY Chemical Handling and Storage Operating Guidelines. Facilities

Transcription:

Standard Operating Procedure Use of liquid nitrogen filling station Date: 02-12-13 SOP Title: Principal Investigator: Room and Building: Lab Phone Number: Section 1 Process Use of liquid nitrogen filling station B304B Stanley Hall Filling of liquid nitrogen dewars from automatic fill station located in B304B. Section 2 Hazardous Chemicals Liquid nitrogen Section 3 Potential Hazards Liquid cryogens pose a potential asphyxiation hazard. Nitrogen expands by a factor of 680 and helium expands by a factor of 740 when changing from the liquid to gas phase. The expanding gas displaces breathable oxygen. To limit the asphyxiation hazard, liquid nitrogen and liquid helium should only be handled in well ventilated areas. Immediately evacuate the room if oxygen senor audible alarm sounds. The extreme cold of liquid nitrogen and helium can cause oxygen to condense from the air, resulting in fire danger. Keep cryogen use areas free of combustible materials (paper, cardboard, machine oil, etc) and eliminate any other sources of ignition.

Section 4 Approvals Required Wemmer group members must be trained by Jeff Pelton and sign the SOP. Section 5 Designated Area Fills are to occur in Rm B304B. Section 6 Special Handling Procedures and Storage Requirements Section 7 Personal Protective Equipment The main hazards associated with handling liquid nitrogen and liquid helium are: A) burns when skin comes into contact with cold pipes or liquid, and b) asphyxiation if nitrogen or helium has expanded from its liquid form and the gas has displaced oxygen. To reduce the potential for injury, follow these guidelines: Avoid contact with cold unprotected pipes and vessels when working with liquid nitrogen or liquid helium. Wear proper protective equipment: o Dry leather or cryogenic gloves must be worn to avoid cold burns. The gloves must be loose fitting so that they can be removed easily. o Goggles or a face shield must be worn to protect the eyes and face. o Wear close-toed shoes and long pants while handling cryogens to protect feet and

legs from accidental spills. Metallic objects (e.g. jewelry) should be removed from those parts of the body that may come into contact with the liquid. Never accompany cryogens in the elevator. If the elevator were to malfunction, the expanding gas could fill the elevator and pose a serious risk of asphyxiation. Load dewar on elevator, post No Passengers sign on the dewar, and retrieve it after using separate route (stairs or another elevator). When transferring cryogenic liquids, always direct the flow away from others. Section 8 Engineering/Ventilation Controls The door to B304B into B304 should remain open during the fill in order to provide adequate ventilation Section 9 Spill and Accident Procedures In case of a liquid nitrogen spill, provide plenty of ventilation and wait for the liquid to vaporize. Section 10 Waste Disposal No waste is generated.

Section 11 - Decontamination Section 12 Process Steps Process Steps Attach liquid line to liquid port on dewar Attach vent line to vent port on dewar Fully open vent and liquid valves on dewar Pull the red STOP botton out to on position Press the fill button and hold for several seconds After the fill is complete, close the liquid and Vent valves on the dewar. Disconnect the hose at the vent port of the dewar Disconnect the hose at the liquid port of the dewar Do this slowly and beware that cold gas trapped in The line will escape Safety Measures Wear a face shield and gloves Push the red STOP button in the halt the fill Wear a face shield and glvoes Wear a face shield and gloves - Troubleshooting If the filling light turns off after releasing the fill Button, the system isn t sensing the proper pressure Check the connections and make sure that both valv are open and connected in the right orientation Vent to vent and liquid to liquid. Training Documentation Name (Printed) Signature Date