CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

Similar documents
Pressure Regulator. Instructions for Use

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Dialflow Regulator. Instructions for Use

Yoke Block Instruction Manual

Pressure Regulators. Instructions for Use

MEDICAL REGULATOR RANGE (MEDIREG RANGE)

Yoke Block Instruction Manual

Micro Dial-Flowmeter. Instructions for Use

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Oxygen Dialflow Meter. Instructions for Use

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Oxygen Dialflow Meter. Instructions for Use

SERIES-O REGULATOR. Instructions for use

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

CF-SERIES HIGH FLOW REGULATORS

Rev. B. Operating Instructions

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

Model ASSEMBLY and OPERATING INSTRUCTIONS

- GAS REGULATOR - COMPACT STYLE

MODEL CALIBRATION GAS DELIVERY SYSTEM

Cocoa Patio Pond with Lit Spillway

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

2-Liter Pressure Cup. Instructions - Parts List C

Interface Devices, Inc. Hydraulic Mini Mule

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

AND OPERATION INSTRUCTIONS

Budget Range Operators Handbook

User Instruction Manual

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Masoneilan* 78 Model Air Filter Regulator

User Operation Manual and Safety Instructions

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

APC Pressure Reducer with Sensor

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Operation Manual Air Saver Unit ASV5000 Series

RK-IR Sample Draw Aspirator Adapter Operator s Manual

for the of and the EM55-1

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

623 Series Dome Load Regulators

TactAir PCP Fill Kit/Adapter. Operation Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

MODEL NUMBER: AS18-2 USER GUIDE

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

453 Series Steam Heated Vaporizing Regulator

30T A/Manual Hydraulic Shop Press

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

LOCK UP VALVES YT-400/405/430/435 SERIES

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Adjustable. Unloader Valve. O&M Manual. Part #

4-in-1 Professional Inflator Kit

RK LEL Sample Draw Aspirator Adapter Operator s Manual

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

SANP ACTING RELAYS YT-520/525/530 SERIES

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

G7S Hand Pump Owner s Manual

Techcon Systems TS1254 Pressure Pot

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

J Air and Water Kit Instructions Part# 02584

Service Manual. Dial Flow Regulators

2.5 & 5.0 GALLON PRESSURE TANKS

Masoneilan* Model 78-80S & 08-80S Transfer Valves

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

Model 405 &407 Small Animal Ventilator. User Manual v3.5

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

User manual. ZX trolley.

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR INLINE METAL SHEAR

Equinox II NITROUS OXIDE / OXYGEN ADMINISTRATION EQUIPMENT 01EQ7000E

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Model VR6 System. Installation, Operation & Maintenance

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Back Pressure Regulator

NITRONOX USER S MANUAL

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Transcription:

ANA 74300 Oxygen Regulator with Yoke Connector User Manual Manual No. ANA 74300 001 Issue 1

Safety Thank you for purchasing this Clements Oxygen Regulator. For your safety it is imperative that this unit only be operated by authorised personnel in accordance with the instructions as described in this manual. Operated in this way, the Oxygen Regulator will provide the standard of service specified. Due to continual improvements in product design, the Oxygen Regulator may vary in detail from the descriptions in this manual. In the event of further questions please contact your local distributor or BMDi TUTA Healthcare direct. M Morris Engineering Works Ltd 43 Kung Yeh Road, Kuan Tien Industrial District Tainan Hsien, Taiwan, Republic of China User Manual Oxygen Regulator Manual Number ANA 74300 001 Issue 1 Copyright 2010 BMDi TUTA Healthcare Pty Ltd The information in this manual was originated by, and is the exclusive property of BMDi TUTA Healthcare Pty Ltd. It is furnished for customer information only, and is not an authorisation or licence to make this product or to furnish this information to others. 2 BMDi TUTA Healthcare Pty Ltd Level 17, 275 Alfred St North Sydney NSW 2060 Australia Phone: +61 2 9466 5300 Fax: +61 2 9922 7165 Website: www.medaust.com

Contents Cautions... 4 Classifications... 5 Specifications... 6 Installation and Operation... 7 Cleaning... 9 Accessories and Spare Parts... 10 Maintenance... 11 Troubleshooting... 12 Warranty... 14 3

CAUTION PLEASE READ THOROUGHLY AND FOLLOW DIRECTIONS CAREFULLY BEFORE OPERATING EQUIPMENT. WARNING OXYGEN IS A NON-FLAMMABLE GAS; IT WILL HOWEVER SUBSTANTIALLY INCREASE THE RATE AT WHICH FLAMMABLE MATERIALS BURN. OIL, GREASE AND OTHER HYDROCARBONS WHEN COMBINED WITH OXYGEN, WILL BECOME HIGHLY COMBUSTIBLE AND SHOULD NEVER BE USED ON ANY PART OF THE OXYGEN CYLINDER, REGULATOR OR OTHER EQUIPMENT USED WITH OXYGEN. GENERAL SAFETY INFORMATION 1. NO SMOKING - Remove matches, lighters, lighter fluid and other flammable materials from the oxygen therapy area before administering oxygen. 2. Inspect the oxygen cylinder valve, regulator and flowmeter thoroughly for dust, oil and grease. DO NOT USE THE OXYGEN REGULATOR IF OIL OR GREASE IS PRESENT! Inform your gas supplier of this condition immediately. 3. If using a humidifier or similar device, remove the device from the regulator before changing the cylinder. DO NOT ALLOW FLUIDS TO ENTER REGULATOR. 4. In any situation requiring emergency oxygen, call a physician or emergency medical service clinician immediately. This unit is an inhaler and is useful only on persons who are breathing prior to administering oxygen. 4 Safety Information

Intended Use Regulate the high pressure from an oxygen gas cylinder to a lower, constant pressure for use with oxygen therapy equipment. Classifications GMDN 35300 Regulator, gas, high-pressure Classification Class IIb ARTG 174010 Clasifications 5

Specifications Gas Medical Oxygen Maximum Inlet Pressure 20MPa [2900psi] Outlet Pressure Regulator Inlet Connector 400kPa [58psi] Fixed output pressure diaphragm style Type pin-indexed yoke CGA 870 AS 2473.3-2007 Outlet Connector Oxygen ring index AS 2896-1998 Safety Pressure safety valve, ball and seat type Gauge 50mm, kpa and colour coded capacity band Gauge Range 0 to 20,000 kpa, graduated at 1,000 kpa Duty Cycle Continuous operation Standard AS 3840.1-1998 Dimensions Unit: 170W x 135H x 90D Packed: 205W x 160 H x 165D Weight Unit: 1.08kg Packed: 1.3kg Ambient Temperature -18 C to 60 C Standard Conditions 25 C, Sea Level, 101kPa Installation and Operation Check for Damage Carefully examine the oxygen regulator for any visual signs of damage that might have occurred during shipment. 6 Specifications

Installation and Operation Connect Regulator to Cylinder 1. Inspect the oxygen cylinder valve, regulator and flowmeter thoroughly for dust, oil and grease. DO NOT USE THE OXYGEN CYLINDER IF OIL OR GREASE IS PRESENT! Inform your gas supplier of this condition immediately. 2. With the cylinder valve outlet facing away from you, slightly open the oxygen cylinder post valve to purge any debris from the valve seat, then re-close the valve. 3. Slip the yoke over the cylinder post valve and fit the yoke pins into the holes in the cylinder valve. The pins should fit easily into their respective holes. Do not force the pins into the holes. 4. Ensure that the sealing washer is in place on the regulator yoke connection and is in good condition 5. Ensure the Tee Handle screw point is seated on the dimple on the cylinder post valve. Turn the Tee handle clockwise and tighten until secure to provide a leak-proof connection. Connect Flowmeter to Regulator 1. Attach flowmeter to the regulator and tighten connector. If the flowmeter is a tube-style unit ensure that the tube is maintained in a vertical tube-up position. 2. Ensure that the flowmeter is off - turn flow control knob clockwise. Pressurise the Regulator 1. Slowly open the cylinder post valve. 2. Confirm that the cylinder pressure gauge indicates adequate capacity. A cylinder with less than 2MPa should be exchanged for a full cylinder to ensure an adequate supply of oxygen. 3. Confirm that there are no leaks in the oxygen cylinder, regulator and flowmeter circuit. Installation and Operation 7

Adjust the Oxygen Flow 1. Turn the flowmeter control knob anti-clockwise until the centre of the ball corresponds with the line indicating the required flow rate. 2. When finished administering oxygen therapy turn the flowmeter control knob clockwise to the off position. Confirm that the ball indicates zero. WARNING Do not use high concentrations of oxygen for more than 5 hours without 1 hour interruptions. Closing the Regulator If the regulator will be used again in a short time (one hour or less) turn the flowmeter control knob clockwise to off. If the regulator will not be used for a longer period of time, turn the cylinder valve clockwise to the OFF position. Removing the Regulator from a Cylinder 1. Turn the cylinder valve clockwise to the OFF position. 2. Open the flowmeter control knob to bleed the residual pressure from the circuit. Allow the gas pressure in the regulator circuit to completely escape. The flowmeter and pressure gauge should both indicate zero. 3. Close the flowmeter control knob. 4. If using a humidifier or similar device, remove the device from the regulator flowmeter before changing the cylinder. Do not allow fluid to enter. 5. Turn the Tee handle anti-clockwise to allow pins to disengage from post. Remove regulator from cylinder. WARNING Never attempt to remove a regulator from a cylinder if the pressure gauge shows pressure. 8 Installation and Operation

Cleaning WARNING Cleaning DO NOT USE ANY OIL BASED OR HYDROCARBON PRODUCTS ON THIS OXYGEN REGULATOR. Clean using a ph neutral disinfectant for wiping clean. Wipe with a damp cloth and dry with paper towel to remove residue. Do not wipe the contact areas of the inlet and outlet connectors. Transportation and Storage Environmental conditions for transportation and storage are shown in the following table. Parameter Minimum Maximum Temperature 10ºC 40ºC Humidity 60% RH 95% RH Barometric Pressure 700 mbar 1060 mbar Cleaning 9

Accessories and Spare Parts ANA 74300 001 ANA 74100 ANA 74100 100 User manual for Oxygen Regulator Oxygen Flowmeter 0-15 litre/min Humidifier for Oxygen Flowmeter ANA 74300 201 Kit, Gauge for Oxygen Regulator ANA 74300 202 Kit, Yoke for Oxygen Regulator ANA 74300 203 Kit, Bodok Seal for Oxygen Regulator (10) ANA 74300 204 Kit, Inlet Filter for Oxygen Regulator (5) ANA 74300 205 Kit, Service, Spring for Oxygen Regulator ANA 74300 206 Kit, Service, Seal/Seat for Oxygen Regulator Maintenance Period Check Action Each Use Visible Damage Repair, replace Leaks Repair, replace Quarterly Gauge Accuracy Repair, replace Outlet Pressure Yoke seal washer Replace Replace 10 Accessories and Spares

Troubleshooting Fault Check Rectify No reading on pressure gauge Cylinder Cylinder valve Pressure gauge Blockage in regulator Replace cylinder Confirm turned on Replace Replace regulator Leaks Outlet pressure incorrect No Flow Seal washer present and in good condition Debris on valve seat Tee handle secure Cylinder valve Confirm pressure with calibrated gauge Self-sealing valve Blockage in regulator Inlet filter blocked Replace seal washer Clean Tighten Confirm turned on Replace regulator Replace regulator Replace regulator Replace inlet filter Service Apart from the sealing washer (Bodok Seal), there are no user-serviceable parts on the oxygen regulator. Refer all service to suitably qualified and authorised personnel. Troubleshooting 11

Exploded View 18 12 Exploded View

Part List Item 1 Body 2 Yoke Connector 3 Safety Relief Body 4 Safety Relief Seat 5 Seat Retainer 6 Relief Spring 7 Cap 8 Spring 9 Seat Assembly 10 Orifice 11 Retainer 12 Diaphragm 13 Diaphragm Plate 14 Nut 15 Gasket 16 Adjusting Spring 17 Spring Seat 18 Cover 19 Label 20 Adjusting Screw 21 Cap 22 Outlet Nipple 23 Lock Nut 24 Outlet Nut 25 Gauge Description Parts List 13

Warranty BMDi TUTA Healthcare Pty Ltd warrants that this product is free from defects in workmanship and materials for a period of 12 months from the date of shipment by BMDi TUTA Healthcare or its authorised agent to the purchaser. Subject to the conditions of this warranty, if the product fails to operate for any reason within the warranty period and the product is returned to the place of purchase at the purchaser's expense, BMDi TUTA Healthcare will repair or replace the product free of charge. If a valid warranty claim is made within 30 days from the date of shipment, then BMDi TUTA Healthcare will also reimburse the purchaser for reasonable freight costs in returning the product to the place of purchase. Conditions of Warranty 1. The product must be returned to the place of purchase with proof of purchase. 2. This warranty is only available to the original purchaser of the product. 3. The product must not have had its serial number removed, defaced or changed, its casing opened, its power supply altered or have been tampered with in any other way. 4. This warranty does not cover : inadequate or incorrect site preparation; improper installation; connection to the wrong voltage; failure of the product due to misuse; the use or operation of the product outside of the physical, electrical or environmental specifications of the product; use in a manner or environment in which the product is not designed to be used; improper adjustment, calibration or operation by the purchaser; the use of accessories including consumables, hardware or software which were not manufactured or approved in writing by BMDi TUTA Healthcare ; 14 Warranty

any modifications of the product which were not authorised in writing by BMDi TUTA Healthcare ; any contamination or leakages caused or induced by the purchaser; and inadequate or improper maintenance of the product. 5. This warranty does not cover normal wear and tear. 6. BMDi TUTA Healthcare will not be responsible for damage or loss caused during shipping. 7. In Australia, apart from any warranties implied by the Trade Practices Act 1974 all other warranties expressed or implied and whether arising by virtue of statute or otherwise are hereby excluded. 8. Outside Australia, all other warranties expressed or implied and whether arising by virtue of statute or otherwise (including any warranties implied by the Vienna Convention) are hereby excluded. 9. BMDi TUTA Healthcare s obligations under this warranty are limited to the repair or replacement of the product, within the terms of this warranty and the total liability of BMDi TUTA Healthcare for loss or damage of any kind whether arising pursuant to the terms of the sale of the product or otherwise in connection with the product is limited to the amount paid by the purchaser to BMDi TUTA Healthcare for the product. 10. Apart from any liability imposed by Part VA of the Trade Practices Act, BMDi TUTA Healthcare accepts no other liability for any loss or damage occasioned (including consequential loss or damages) in any way as a result of the use of the product. 11. The warranty does not extend to cover damage to the following parts as they are inherently prone to wear : motor brushes 12. This warranty does not extend to cover corrosion due to any cause nor to any damage to painted or anodised surfaces. 13. BMDi TUTA Healthcare will give the purchaser the benefit of any manufacturer's warranty in respect of any components in the product which were not manufactured by BMDi TUTA Healthcare, if such a manufacturer's warranty is available. Warranty 15