VER: A00. Model No:BA2010

Similar documents
Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

Instruction Manual. S&S Tradings

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

5 series Blood Pressure Monitor

Auto Arm Blood Pressure Monitor

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Sports Wrist Digital Blood Pressure Monitor Item #

Digital Blood Pressure Monitor. Model UA-705. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni 1WMPD B

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

6833_INSTRUCTIONS MANUAL DIGITAL WIRST BLOOD PRESSURE

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

Digital Blood Pressure Monitor. Model UA-787

User Manual. Hopkins IMPACT Digital Wrist BP RELATED ITEMS. Item #526014

Contents. Safety Notice. Wrist Type

Semi-Automatic Blood Pressure Monitor with Memory

Instruction Manual. Wrist Blood Pressure Monitor with Advanced Positioning Sensor (APS ) Model HEM-650 ESPAÑOL ENGLISH

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

REF CH-302B IDENTIFICATION OF PARTS

premium wrist blood pressure monitor

Wrist Type Blood Pressure Monitor

Fully Fuzzy Auto Digital Wrist Blood Pressure Monitor. tensio control. INSTRUCTION MANUAL Model GP-6220

MODEL CH-432B INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. - Eng 1 - English Español Português Deutch. Italiano Français CH-432B

GoWISE USA R Blood Pressure Monitor Wrist Type. Instruction Manual

Talking Wrist Style Blood Pressure Monitor Model INS-LAB-RevB08

REF CH-602B IDENTIFICATION OF PARTS

Instruction Manual. Auto Inflate Blood Pressure Monitor

Digital Blood Pressure Monitor for the Upper Arm INSTRUCTION MANUAL

Check following components!

Fully Automatic Blood Pressure Monitor

Digital Blood Pressure Monitor Model UA-621 Instruction Manual

English Español Português Italiano Deutch Français INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR MODEL CH-656C. - Eng 1 -

Talking Wrist TypeBlood Pressure Monitor. Talking Wrist Type Blood Pressure Monitor Model: BPW810. User Manual

Oregon Scientific Wrist Blood Pressure Monitor (BPW211)

Model UA-705. Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Blood Pressure Monitor

Operating Instructions Instrucciones de funcionamiento

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

Wrist Blood Pressure Monitor Model R2

Owner s Manual. EZ Health TM Platinum Talking Automatic Wrist Blood Pressure Monitor ABP-A3

MEDICARE 60. Semi-automatic upper arm blood pressure monitor. Instruction manual

Instruction Manual. Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

SBC 21. Electromagnetic Compatibility Information

Blood Pressure Monitor

Model UA Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Blood Pressure Monitor

VIDEO TUTORIAL: greatergoods.com/0605

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing

Fully Automatic ihealth Track Connected Arm Blood Pressure Monitor USER MANUAL

TD-3140 Blood Pressure Monitor. Owner s Manual

TD-3140 Blood Pressure Monitor. Owner s Manual

VGP-4300-G. Travel Pulse. Blood Pressure Monitor for Travel

Content

Owner s Manual & Safety Instructions

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing

Blood Pressure Monitor

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

Blood Pressure Monitor

Contents. Helpline No. UK/Northern Ireland , Rep. Ireland Web Support Model Number:

ProSeries 2. Blood Pressure Monitor. Quick Start Guide. A complete user guide is available at vitasigns.com

Instructions for use. 3year. Wrist MOBIL BASIS. The monitor for first users To be used on the wrist. Also suitable for: WARRANTY. Clinically validated

Model M3 Intellisense

Blood Pressure Monitor

Model MIT Elite Plus

INSTRUCTION MANUAL DIGITAL BLOOD PRESSURE MONITOR

LD6. Digital Blood Pressure Monitor Instruction Manual

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

LD7. Digital Blood Pressure Monitor Instruction Manual. Ciśnieniomierz elektroniczny automatyczny LD Instrukcja Obsługi ENG POL

Fingertip Pulse Oximeter

Blood Pressure Monitor

User Manual DMD1001. Arm Type. Digital Blood Pressure Monitor. version:1.0

Aneroid Sphygmomanometer. Use, Care, & Maintenance

Oregon Scientific Wrist Blood Pressure Monitor (BPW120)

STANDARD OPERATING PROCEDURE ARTSANA MERCURY SPHYGMOMANOMETER

SpotArm Type Blood Pressure Monitor. Model i-q142

Instructions. Upper Arm Blood Pressure. Model EW3153

INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR

User Manual DMD1001. Arm Type. Digital Blood Pressure Monitor. version:1.0

User Manual DMD1001 1

LD22. Digital Blood Pressure Monitor Instruction Manual

REF CH-308B INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR IDENTICATION OF PARTS Eng 1 - Exhaust button Air connector Pumping bulb tube

Instruction Manual. Automatic Blood Pressure Monitor for Arm - Voice Prompt Function Announces Measured Values HB-ZA310V

Device Equivalence Evaluation Form Comparison of the Omron RS2 (HEM 6121 E) with the Omron RS3 (HEM 6130 E)

MODEL CH-485E INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. English Español Português Deutsch. English Español Português Deutch Français

WARNING: EXPLOSION HAZARD

Blood Pressure Monitor B06T

Blood Pressure Monitor Instruction Manual

3.1.3 Weight. Frequency. Weight is obtained at the baseline examination and annually. Equipment

UA-851THW/UA-851TMW/UA-851THX Wireless Automatic Blood Pressure Monitor Users Manual

Owner's Manual. Wrist-type Fully Automatic Blood Pressure Monitor. Contents. Safety Notice. Model BP2116. Document No. Version: REV

Blood Pressure Monitor Instruction Manual

BM 26 ENGLISH. Blood pressure monitor Instructions for use... 2

User Manual. Wrist Blood Pressure Monitor. Wrist Type

12V AIR STATION ALL-IN-ONE

Device Equivalence Evaluation Form

User Manual. Bluetooth Pedometer. AmericanPumpkins. version:1.0

USE, CARE & MAINTENANCE DIAGNOSTIX TM 972 MERCURIAL BLOOD PRESSURE INSTRUMENT

Automatic Blood Pressure Monitor Model M6 Instruction Manual

INSTRUCTION MANUAL. Pedometer Downloadable Model: HJ-323U ENGLISH

Transcription:

VER: A00 Model No:BA2010

Before Using the Monitor Introduction...1 Symbols Use...2 Important Safety Notes...3 Konw Your Unit...45 IHB Introduction...6 Before Taking A Measurement...7 Quick Reference Guide...8 Operating Instructions Battery lnstallation/replacement...9 Adjusting Settings...10 Proper Use of the Arm Cuff...1112 Take a Measurement...13 Use the Memory Function To read the average value...14 To read the measurement value...14 To delete all values stored in the memory...15 About Blood Pressure Blood Circulation...16 Health and Blood Pressure...16 Classification of Blood Pressure...17 Care and Maintenance Exceptional Situations Error Indicators...18 Eliminate Fault...18 Care and Maintenance Care...19 Maintenance...19 Specifications...20 Indications for Use Statement...21 Statement...21 Warranty Information...22 Thank you for purchasing Fully Automatic Upper Arm Style Digital Blood Pressure Monitor. The unit uses the oscillometric method of blood pressure measurement. It means the unit detects the movement of your blood through your brachial artery, and converts your blood pressure into a digital reading. The unit is simple to use because a stethoscope is not needed while using an oscillometric monitor. The unit stores automatically 60 sets of measurement values. You can read the stored data conveniently by pressing the memory button. The unit comes with the following components: Main Unit Arm Cuff Storage Bag Instruction Manual printed in English

Symbols Use SYMBOLS USED IN THIS INSTRUCTION MANUAL Indicates a potentially hazardous situation WARNING which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not CAUTION avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property. Type B applied part AUTHORISED REPRESENTATIVE IN THE EUROPEAN COMMUNITY Refer to instruction manual/booklet MANUFACTURER SERIAL NUMBER The marking of electrical and electronics devices according to Directive 2002/96/EC. The device,accessories and the packaging have to be disposed of waste correctly at the end of the usage. Please follow Local Ordinances or Regulations for disposal. To assure the correct use of the product basic safety measures should always be followed including the precautions listed below: Read all information in the instruction manual and any other literature included in the box before using the unit. Contact your physician for specific information about your blood pressure. Selfdiagnosis and treatment using measured results may be dangerous.follow the instructions of your healthcare provider. Operate the unit only as intended. Don't use for any other purpose. The unit is intended to use in measuring blood pressure and pulse rate for adult only, not recommended for neonatal baby at home or medical centre. Do not use a cellular phone near the unit. It may result in operational failure. Please avoid using in high radiant area in order to make your measuring data correctly. Do not disassemble or attempt to repair the unit or components. Do not use the equipment where flammable gas (such as anesthetic gas, oxygen or hydrogen) or flammable liquid (such as alcohol) are present. 2 3

Know Your Unit Know Your Unit Body Display Arm Cuff Fit for 22cm~32cm range of upper arm perimeter Air Plug (Insert to Air Socket) Air Socket BA2010 Start/Stop Button Hose Memory Button Metal Display If your arm cuff is broken or not functional, please use a new cuff. A new arm cuff does not include an air plug. Please continue to use the old air plug on the new arm cuff. Power Pouch Inflation/Deflation Symbol or WHO Indication Low Battery Symbol Average Value Symbol Memory & Times Irregular Heartbeat Symbol Systolic Blood Pressure Diastolic Blood Pressure Unit Indication Pulse Heartbeat Symbol 4 AA Alkaline Batteries Instruction Manual Please keep the instruction manual well after using. Warning: 1. Do not use rechargeable batteries. 4 5

IHB Introduction Before Taking A Measurement Irregular Heartbeat Symbol( ) When the unit detects an irregular rhythm two or more times during the measurement, the irregular heartbeat Symbol will appear on the display with the measurement values. An irregular heartbeat rhythm is defined as a rhythm that varies by less than 25% from the average rhythm or 25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure. Normal Heartbeat Pulse Blood pressure Irregular Heartbeat Short Long Pulse Blood pressure If the Irregular Heartbeat Symbol( ) displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor. 1.Avoid eating,drinking alcohol, smoking, exercising and bathing for 30 minutes before taking a measurement. 2.Stress raises blood pressure. Avoid taking measurements during stressful times. 3.The cuff can be applied to your left or right wrist.always measure your blood pressure on the same Arm. 4.Measurements should be taken in a quiet place. 5.Position the unit at heart level throughout the measurement. 6.Remain still and do not talk during the measurement. 7.Keep a record of your blood pressure and pulse readings for your physician.a single measurement does not provide an accurate indication of your true blood pressure.you need to take and record several readings over a period of time.try to measure your blood pressure at the same time each day for consistency. 8.Wait 30~60 seconds between measurements. The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement.you may need to increase the wait time depending on your individual physiological characteristics. 6 7

Remove the battery cover from the battery compartment. Install 4 AA size batteries so the (positive) and (negative) polarities match the polarities of the battery compartment as indicated. Replace the battery cover. Press the START/STOP button. All symbols appear,then the cuff starts to inflate automatically. / M EM S TART/S TOP 8 9

Adjusting Settings Proper Use of the Arm Cuff Press the MEM button about 10 seconds unil the units (kpa or mmhg) displayed when the unit turned off. Then press the MEM button again to change the current unit. Press the START/STOP button to save the current setting and turn off. 1 Make sure the air plug is inserted properly in the main unit. BA2010 M EM S TA RT/S TO P mmhg display kpa display 2 Remove all clothes from your upper arm allowing the cuff to fit directly on the skin. 3 Sit in a chair with your feet flat on the floor. Place your arm on a table so as to level the cuff to your heart. 4 Pass the end of the cuff through the metal, and keep the hose outward. 10 11

Proper Use of the Arm Cuff Take a Measurement 5 Put your arm through the loop, then pull it up to the position of your upper arm. 1 Press the START/STOP button. All display symbols appear on the screen. The cuff starts to inflate automatically. All symbols display Deflating automatically Start to inflate 6 The hose runs down the inside of your arm. The bottom of the cuff should be approximately 1~2cm above your elbow. 1 ~ 2cm 2 Measurement starts while inflating. The heartbeat symbol flashes once a pulse is detected. Start to inflate Inflating To a fit pressure Deflating Deflating 7 Wrap the cuff tightly around your upper arm by using the Velcro strip. Do not leave any spacing between the arm and the cuff. 8 Relax your arm, keep the palm upward and the fingers curving naturally, then turn on the unit and start to measure. 12 3 The blood pressure and pulse rate are displayed when the measurement completed. The cuff is deflated automatically, and all of the measurement OR OR results are stored in the memory. The symbol will be displayed if irregular heartbeat is detected. "kpa" display "mmhg" display " " display 4 Press the START/STOP button to turn off the unit. The unit will anutomatically turn off after 2 minutes if you have forgotten to turn it off. NOTE: To stop the inflation or measurement,push the START/STOP button,the unit will stop inflating and then release and turn off. INSTRUCTIONS FOR SPECIAL CONDITIONS In order to accelerate the measurement time for the systolic pressure more than 180 mmhg, press and hold the memory button until the unit inflates 30 to 40 mmhg higher than your suspected systolic pressure if you know. ( The unit will not inflate above 299 mmhg). 13

M EM S TART/S TOP Use the Memory Function Use the Memory Function The unit stores the blood pressure and pulse rate in the memory after completing a measurement every time. It can automatically store 60 sets of measurement values. The oldest record is deleted to save the latest measurement value when more than 60 sets. The unit also calculates an average reading based on the values of the latest 3 times measurement taken. To read the average value Press the MEM button. The average value symbol will display. To delete the memory value... In the memory reading mode, press the MEM button for 46 seconds, the unit will display Press the MEM button again and confirm to select or. If you are sure all the data of corresponding user can be deleted, press the START/STOP button, all the corresponding user s data will be deleted and the unit will turn off. Turn to next M EM S TART/S TOP the average value of all measurent values TO read the measurement value... Press the MEM button to view the latest measurement value with the measuring date. Long press the button and the value quickly changes. Note: if you have set, but do not press a button for 2 minutes, the product will shut off automatically, but the corresponding user s blood pressure data will not be deleted. The delete operation must be confirmed by user. M EM S TA RT/S TO P The 1st latest measurement value The 2nd latest measurement value The 60th latest measurement value 14 15

Blood Circulation About Blood Pressure The blood circulation is responsible for supplying the body with oxygen. Blood pressure is the pressure exerted on the arteries. The systolic blood pressure value (higher pressure or top value) represents the blood pressure produced by contraction of the heart muscle. The diastolic blood pressure value (lower pressure or lower value) represents the blood pressure produced by relaxation of the heart muscle. Systolic Blood Pressure Contraction of the heart muscle Extrude blood Pressure increased to the blood vessel Higher pressure Diastolic Blood Pressure Relaxation of the heart muscle Blood return heart Pressure decreased to the blood vessel Lower pressure About Blood Pressure Classification of Blood Pressure After each measurement is completed, the LCD display will show your position automatically on the six segments of the bar indicator which corresponds to World Health Organization (WHO) Blood Pressure Indicator. 110 100 90 85 80 Reference Material: Journal of Hypertension 1999, Vol 17 No.2 Diastolic Blood Pressur (mmhg) Normal blood pressure Optimal blood pressure (target value) Mild hypertension Normal systolic value Severe hypertension Moderate hypertension WHO 120 130 140 160 180 Systolic Blood Pressure (mmhg) *Note! When a person s systolic and diastolic pressures fall into different categories, the higher category should apply. Red Yellow Green Classification of Blood Pressure 16 17

Error Indicators Exceptional Situations The following symbol will appear on the display when measuring abnormally. Symbol Cause Correction The course of inflating appears error. When measurement fails. Wrap the cuff correctly and tightly. Ensure the connection is close between the air plug and the unit. Inflate over again after ensuring. Do not move your arm and body, and keep quiet. Measure over again according to correct way. Care Care and Maintenance Keep the unit in the storage case when not in use. Clean the unit with a soft dry cloth. Do not use any abrasive or volatile cleaners. Never immerse the unit or any components in water. If needed, please use ultraviolet radiation for disinfection. Avoid subjecting the monitor to strong shocks or vibrations, such as dropping the unit on the floor. Maintenance Do not clean the body and cuff with naphtha, thinner or gasoline etc. Do not wet the cuff or attempt to clean the cuff with water. When the batteries power are too low. Replace all of the worn batteries with new ones. naphtha thinner gasoline Eliminate Fault No power. Problem Causes and Solutions Replace all the worn batteries with 4 new ones. Store the unit in a clean and dry location. Do not subject the unit to extreme hot or cold temperature, humidity and direct sunlight. Remove the batteries if the unit will not be used for 3 months or longer. Always replace all of the batteries with new ones at the same time. No display appears on the display screen. Measurement values appear too high or too low. Check the battery installation for proper placement of the batteries polarities. Blood pressure varies constantly. Many factors including stress, time of day, how you wrap the cuff, may affect your blood pressure. Review the sections "Proper Use of the Arm Cuff" and "Take a Measurement". 18 Use the unit consistent with the instructions provided in this manual. Use only authorized parts and accessories. 19

Indications for Use Statement BA2010 The unit is intended to be used to measure blood pressure (systolic and diastolic) and heart rate from the upper arm by using the oscillometric method. The unit is intended for usingin only adult population,not applied to the other populations such as neonatal baby. 180 It can t be used while the wirst (arm) has bleeding or wound to avoid the blood flowing from the wound in pressurzing. The unit satisfies the requirements of IEC606011 Medical electrical equipment, EN10601: Noninvasive sphygmomanometer, EN10603: Noninvasive sphygmomanometer. The Unit complies with IEC 80601230. Automatic Turn Off 60 Sets of Measurement Values 4 AA Alkaline Batteries Within 2 Minutes Approx. 420g (Batteries not included) 20 10~40 (50 ~ 104 F ) 15 ~ 90% RH (Noncondensing) 80~105 kpa 20~60 (4 ~ 140 F ) 10 ~ 95% RH (Noncondensing) 21

Warranty Information Federal law restricts this device to sale by or on the order of a physician. The unit, excluding the unit cuff, is guaranteed to be free of defects in workmanship and materials for a period of two years from the date listed on the purchase record. when used in accordance with the instructions provided with the unit. The unit cuff is warranted to be free from detects in materials and workmanship appearing within one year from the date listed on the purchase record when the unit is used in accordance with the instructions provided with the unit. For repair under this warranty. Our authorized service agent must be advised of the fault within the period of the warranty. This warranty covers parts and labor only under normal operations. A transportation fee or freight fee that may be incurred will be the owner's responsibility. Any defect resulting from natural causes, e.g., flood, hurricane etc., is not within this guarantee. This guaranty does not cover damage incurred by: use of the unit not in accordance with the instructions, accidental damage, or being tampered with or serviced by unauthorized service agents. Unit subjected to misuse, abuse, and neglect of these manual content, noninstructional purposes; unauthorized repair or modifications will be excluded from this warranty. This guarantee specifically excludes expendables and consumables, for example batteries. All warranty claims must be directed to the distributor responsible for the sale of the device. The content of this warranty is subject to change without further notice. Periodical check: Sensitive measuring devices must be checked from time to time for accuracy and leakage, we therefore recommend that the performance should be checkedevery 2 years. Check and maintenance and repair for the unit, please contact the local distributor for details. 22