Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

Similar documents
Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Straight-Way Valve with Packing Gland

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. Steel Valves Stainless Steel Valves

// ADapters GUIDelines

Declaration of Conformity as per Directive 97/23/EC

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Installation & Operation Manual Proven Quality since 1892

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

USER MANUAL. 1. Principle of operation. 2. Delivery condition. SPRING-LOADED SAFETY VALVES zarmak. Edition: 07/2016 Date: V (ex.

Type BBS-03, BBS-05, BBS-06, BBS-25

USER MANUAL Version: 1/2017

Declaration of Conformity as per Directive 97/23/EC

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Operating and maintenance manual Filter and reducing station Series / 1.0

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

ITT RICHTER CHEMIE-TECHNIK

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

Flowmeter. Original operating manual DFM

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

PV4 and PV6 Piston Valves

Compact Ball Valves ASAHI AV VALVES. Contents. User s Manual. (Page) (1) Be sure to read the following warranty clauses of our product 1

Manual Actuated Boiler Blowdown Valves

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Declaration of Conformity as per Directive 97/23/EC

Pressure relief valve

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Instruction Manual. Pressure Vessels

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Pressure relief valve

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Instruction Manual Contact Pressure Vacuum Gauge

Engineering Data Sheet

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

Pressure maintenance valve SDV-P / SDV-P-E

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

Operating instructions - Translation of the original -

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Installation, operation & maintenance manual - original version

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

MAINTENANCE AND OPERATING MANUAL

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Coiling Tube with Twist-Proof Fitting

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Translation of the original Operating Instructions for HKS rubber compensators

Siphon vessel / Priming aid

Control Valve with ZK Radial Stage Nozzle ZK 210. Original Installation Instructions English

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E

CAST IRON SAFETY VALVE TYPE 6301

Universal Charging and Testing Unit FPU-1

Telefon (+45) Telefax (+45)

for the of and the EM55-1

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Diaphragm Pressure Keeping Valve

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Operating instructions - Translation of the original -

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Non-Return Valve SRK 22A

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

Pressure Relief Valve DHV 718

Operating instructions - Translation of the original -

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

MANUAL. Sesame. Thermoplastic Tank Technologies

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Pressure Reducing Valve DMV 750

OPERATING INSTRUCTIONS

Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

FLANGED TWO-PIECE BALL VALVES

Installation and Operating Instructions Bypass Flow Meter DST

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Installation, Operation, and Maintenance Manual

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

Pressure Relief Valve Instruction Manual

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

Transcription:

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU FAS Manual Brass Shut-Off Valve DN10 through DN22 Please read these operating instructions carefully to ensure a safe operation and keep the same for further use. 2016 Armaturenwerk Altenburg GmbH Am Weißen Berg 30 04600 Altenburg, Germany

Operating instructions for FAS Manual Brass Shut-off Valve DN10 through DN22 Contents Safety... 4 Authorized personnel... 4 Residual dangers... 4 Symbols used for safety information... 4 General safety information... 5 Other information... 5 Description of valve... 6 Types (possible combinations of connections)... 6 Operating principle... 7 Product description... 7 Identification... 8 Technical parameters... 8 Design features... 9 Transport and Storage... 9 Mounting...10 Principles...10 Mounting preparation...10 Connecting the pipe...11 Commissioning...12 Principles...12 Steps of commissioning...12 Operation, Maintenance and Repair...13 Principles...13 Repair...13 Dismantling and Disposal...14 Principles...14 Document 90000704 Revision 01 Sh. 3 of 16

Operating instructions for FAS Manual Brass Shut-off Valve DN10 through DN22 Safety The FAS manual brass shut-off valve DN10 through DN22, hereinafter referred to as valve, is designed for use in refrigeration/air conditioning systems referred to as systems hereinafter. It may only be put into service if installed into the system unchanged in accordance with these instructions and as a whole is compliance with the statutory provisions. The valve incorporates state-of-the-art technology and has been built according to the applicable regulations. Great valve has been set upon the user s safety. These operating instructions are integral part of the contract and shall be kept throughout the entire life of the valve. Authorized personnel Only trained and instructed personnel shall be allowed to do any work on the valve and system. As regards the qualification and expertise of the personnel the applicable rules and guidelines shall apply. Residual dangers Unavoidable residual hazards may emanate from the valve. Every person working on this device shall therefore carefully read these instructions. To be observed are for example: - the generally accepted safety regulations, - EC directives, - Norms (e.g. EN 378) and all national provisions. Symbols used for safety information DANGER! Instructions on preventing imminent serious danger to persons. Imminent most serious injuries or death as a possible consequence. Any non-observance may lead to an immediate failure of the valve. Instructions on preventing potential serious danger to persons. Avoidable serious to very serious injuries or death as a possible consequence. Any non-observance can cause the valve to fail. CAUTION! Instructions on preventing a minor danger to persons. Minor, reversible injuries cannot be excluded. Any non-observance may lead to a medium-term failure of the valve. ATTENTION! Instructions on preventing potential damage to equipment. Minor, reversible injuries cannot be excluded. Any non-observance may lead to a medium-term failure of the valve. Sh. 4 of 16 Document 90000704 Revision 01

General safety information Operating instructions for FAS Manual Brass Shut-off Valve DN10 through DN22 These operating instructions are based on the safety requirements of DIN EN 378-2 and DIN EN 12284. Instructions to prevent hazards in all cycles of service life: DANGER! Risk of bursting if operated beyond the technical parameters. Most serious injuries and immediate system failure possible. Observe the technical parameters. Risk of bursting in an environment causing stress corrosion cracking. Most serious injuries and immediate system failure possible. Observe the environmental conditions for brass! Damage due to improper handling. Serious injuries and system failure possible. Never use the valve as transport, lifting or lashing point. Any non-observance of the instructions may cause the valve to fail. Avoidable serious to very serious injuries or death possible. Installation, operation and maintenance by authorized trained personnel only. Risk of service fluid to be released. Depending on the kind of service fluid serious to very serious injuries or death possible. Wear personal protective equipment (e.g. respirators, gloves). CAUTION! Very cold or very hot surface temperatures possible. Frostbites/burns possible. Wear personal protective equipment (e.g. respirators, gloves). Other information The information contained herein represents to the best of our belief our knowledge at the time when these instructions were prepared. They shall give you guidance how to safely handle the valve during transport, storage, installation, commissioning, maintenance and dismantling/disposal. A final decision as to whether the valve suits the purpose is to be taken by the user. This information shall not be deemed a warranty of quality or a guarantee. Any modification of the valve and operation under other than the prescribed parameters shall not be allowed and will result in the loss of the conformity declaration and all liability claims. Document 90000704 Revision 01 Sh. 5 of 16

Description of valve Operating instructions for FAS Manual Brass Shut-off Valve DN10 through DN22 Types (possible combinations of connections) Installation dimensions can be gathered from the AWA product catalogue and technical documents respectively. The connecting options A through D are explained in more detail in "Design features". Sh. 6 of 16 Document 90000704 Revision 01

Operating principle Operating instructions for FAS Manual Brass Shut-off Valve DN10 through DN22 Product description The manual brass shut-off valve DN10 through DN22 is a stop valve for refrigeration or air conditioning systems and for operation it has to be fully open or fully closed. According to DIN EN 378-2 the valve can only be operated by use of a tool/handwheel/spindle wrench. The position of the valve spindle as supplied (normally open) can be gathered from the technical documentation. The protective spindle cap is finger-tight. The mounting position and flow direction are optional. The valve is in compliance with DIN EN 12284:2003 and Pressure Equipment Directive 2014/68/EU. The ROHS directive 2011/65/EC and REACH regulations No. 1907/2006/EC are complied with. Document 90000704 Revision 01 Sh. 7 of 16

Operating instructions for FAS Manual Brass Shut-off Valve DN10 through DN22 Identification The valve is marked in accordance with DIN EN 12284 on the valve body as follows: Manufacturer s logo Type designation Date of manufacture Permissible pressure in bar Nominal diameter Housing material Technical parameters Pressure/Temperature allocation: Depending on the data given in the technical documentation. Service fluids: Refrigerants according to DIN EN 378-1-2012, DGRL fluid group 2 and associated refrigerator oils according to DIN 51503-1. On request other refrigerants can be permitted. It is explicitly indicated in the technical documentation. Leakage test: according to DIN 8964-3 (<4.1 g/a R-134a at 10bar) Strength test: according to DIN EN 12284 at 1.43-fold PS Cleanliness of interior: according to DIN 8964-1 Classification pursuant to Pressure Equipment Directive (PED 2014/68/EU): As per Article 4 (3) of good engineering practice. Sh. 8 of 16 Document 90000704 Revision 01

Design features Operating instructions for FAS Manual Brass Shut-off Valve DN10 through DN22 The material of the valve components and the manufacturing method are selected in conformity with the EN12284:2003 and Pressure Equipment Directive 2014/68/EU thus guaranteeing the reliability for the operating range indicated. The use of heat-resistant materials and connecting elements obviates the need of dismantling the valve when the system is installed (brazing). The valve spindle comes with wrench flats for operation and has a back seat function. The back seat is only effective when the valve is fully open. Sealing between the spindle and the housing is by corrugated pipe. The valve comes with a highly leak-proof protective spindle cap of brass as a standard feature. A handwheel type is available on request. Usually cap valves cannot be converted to handwheel valves. Types of connection Connection "A" Detachable 90 flared coupling with male connection to render a joint with copper pipes (outside diameter 10 to 22mm or 3/8 to 7/8 ) and cap nut. Size Thread Copper pipe inches / metric SAE 3/8 5/8-18 UNF 3/8 10 SAE 1/2 3/ 4-16 UNF 1/2 12 SAE 5/8 7/8-14 UNF 5/8 16 SAE 3/4 1 1/16-12 UNF 3/4 18 SAE 7/8 1 1/4-12 UNF 7/8 22 Connection "B" Detachable threaded connection according to DIN 3866 with NPTF threaded journal acc. to ANSI/ ASME B 1.20.1 and ANSI B1.20.3. Connection "C" Brazed capillary connection to render a brazed joint with copper pipes acc. to DIN EN 12735-1:2010 for outside diameters 10 to 22 mm or inch-type pipes 3/8 to 7/8. If transported and stored in dry condition, corrosion protection is ensured until installation. The service-friendly design makes it possible to purchase spare parts separately (e.g. valve bonnet, spare cone, gaskets, protective spindle cap, etc.) incl. mounting instructions. Transport and Storage Transport the valve by closed means of transport in the original packing protected against weather influences and store it in dry rooms. Document 90000704 Revision 01 Sh. 9 of 16

Operating instructions for FAS Manual Brass Shut-off Valve DN10 through DN22 Mounting Principles The valve shall be arranged in the system so that it can be properly operated and maintained. DANGER! Damage of valve possible. Serious injuries and system failure possible during operation. Valve to be installed without additional loads (forces, vibrations, etc.). Never use the valve as fixing point of pipes. In particular a removal space of min. 100mm shall be provided for spindle operation, the protective spindle cap and the replacement of the valve bonnet. A safe operation of the spindle (opening and shutting off) at the required torques must be possible. Only authorized personnel shall be allowed to mount the valve. DANGER! Any non-observance of these instructions may cause the valve/system to fail. Most serious injuries and death possible. Mounting and operation by personnel trained in refrigeration systems only. No modifications of the valve permitted. If modifications become necessary, they have to be agreed with the manufacturer prior to mounting. Product features may change. Avoidable serious to very serious injuries or death possible. Any modification of the valve has to be agreed with manufacturer in advance. Mounting preparation When supplied the valve is open and may come with additional protective means for transport. To avoid corrosion inside the valve and contamination, such protective means should be removed shortly before mounting. ATTENTION! Possible damage of interior components. Malfunction due to oxidation/contamination of internal components. Remove the transport protection shortly before mounting. Connections "C" only: Arrange the spindle centrally. For correct brazing the valve bonnet needs not be removed. ATTENTION! Damage of internal components possible. Malfunction of valve due to thermal overload. Centrally arrange the spindle for thermal joining processes. Sh. 10 of 16 Document 90000704 Revision 01

Connecting the pipe Operating instructions for FAS Manual Brass Shut-off Valve DN10 through DN22 1. The pipe / connection must be of a dimension that fits the valve. If not, use adapters. 2. Connections A and B only: Screw the valve with the mating part free of any mechanical constraint. Use the wrench flats at the valve body for counter pressure. Observe the torques (item 6). Excessive torques or non-observance of the mounting order may result in failures. Serious injuries and system failure during operation possible. Observe the torques! 3. Prepare the system connections so (bare metal and free from grease) to achieve a highquality joint. While brazing scavenge the relevant pipe sections with shielding gas. A cooling of the valve body with connection variant C is recommended. Then, cool down the system connection in the air. Clean the pipe connections rendered. Flux material residues are very corrosive and may cause long-term damage. Damage of valve due to strong heating possible. Serious injuries and system failure possible during operation. Do not heat the system connection above 700 C. Keep the flame away from the valve. Damage of valve (e.g. cracks) due to rapid cooling possible. Serious injuries and system failure during operation possible. Allow the joint to cool down in the air. ATTENTION! Damage of internal components possible. Malfunction due to oxidation of internal components. Scavenge with shielding gas while doing the joining. CAUTION! Risk of increased corrosion and component damage. Serious injuries and system failure possible during operation. Properly clean the joint after joining. 4. Depending on which condition is intended fully open or close the spindle. Then, tightly screw on the protective spindle cap at the tightening torque defined. If a subassembly is to be mounted, shut the pipe ends using dust caps until further use. 5. Observe the following torques for nominal sizes DN 10 to 22 (Nm): Nominal dia. Spindle closed Spindle open Protective spindle cap Valve cap Flared coupling DN 10 10 + 2 10 +5 30 + 5 80 + 10 33 +9 DN 12 10 + 2 10 +5 30 + 5 80 + 10 50 +12 DN 15 10 + 5 12 +5 30 + 5 110 + 10 63 +14 DN 16 10 + 5 12 +5 30 + 5 110 + 10 63 +14 DN 18 15 + 3 15 +5 30 + 5 140 + 10 90 +20 DN 22 15 + 3 15 +5 30 + 5 140 + 10 110 +20 Document 90000704 Revision 01 Sh. 11 of 16

Commissioning Principles Operating instructions for FAS Manual Brass Shut-off Valve DN10 through DN22 The valve has already been tested for leakage and strength by the manufacturer. The valve and the system into which it is installed, may only be commissioned if they have been checked, with due regard to the intended mode of operation, for proper condition as to assembly, installation, set-up conditions and safe functioning. After mounting and initial start-up according to DIN EN 378-2:2012 check again for leakage and strength and an effective corrosion protection. Steps of commissioning 1. Check the system for resistance to pressure by suitable means (e.g. helium, dry nitrogen). DANGER! Danger of bursting. Most serious injuries possible. The test pressure must not exceed the maximum allowable pressure (PS). Strictly observe the safety information (e.g. DIN EN 378). 2. Evacuating and filling the system with refrigerant. DANGER! Danger of bursting if operated beyond the technical parameters. Most serious injuries possible. Observe the technical parameters of the valve. Make sure the system is not filled with an excessive amount of refrigerant. 3. Depending on the intended operating condition either completely open or close the spindle. Then, put on the protective cap and tighten it applying the prescribed torque (see chapter "Mounting"). Any torque beyond the limits may lead to failure. Serious injuries and system failure during operation possible. Observe the torques. 4. Upon initial commissioning check the pipes for any abnormal vibration and record the operating data. CAUTION! Cracks of the piping and the valve due to dynamic loads possible. Injuries and system failure during operation possible. Avoid heavy vibrations. Take safety measures if need be. Sh. 12 of 16 Document 90000704 Revision 01

Operating instructions for FAS Manual Brass Shut-off Valve DN10 through DN22 Operation, Maintenance and Repair Principles The valve is maintenance-free. As part of the regular system inspection it should be checked for corrosion/damage and operability and its proper condition restored if necessary. Media contact possible, contact with hot/cold surfaces. Burns, frostbites Wear personal protective equipment as prescribed by national regulations during maintenance and inspections. If the valve spindle has to be operated for system maintenance, carefully remove the protective spindle cap. If no pressure compensation can be effected, put the protective spindle cap in place again and tighten it. If so, it indicates a malfunction of the valve and the system has to be stopped without delay. Repair The protective spindle cap is pressure-proof and may be pressurized. Serious injuries possible. Slowly remove the protective cap of the spindle. Allow any service fluid escape from inside the cap if necessary. Then, put the spindle in the correct position applying the necessary torques (see chapter Mounting). Upon completion of work put the protective spindle cap in place again. If the valve needs repair, shut down the system, drain the refrigerant from the system (or system section) in an environmentally friendly manner and ventilate the system. DANGER! Refrigerant may escape. Leaking refrigerant may cause most serious injuries. For repairs the system must have the right temperature, free from refrigerant and sufficiently ventilated. For repairs use no other than original spare parts. For mounting/start-up follow these operating instructions. It is indispensable to do a leakage and strength test once again. AWA assumes no warranty for tightness after repairs. Valve damage due to defective spare parts/mounting. Avoidable serious injuries and system failure possible. Use no other than original spare parts for repairs. Document 90000704 Revision 01 Sh. 13 of 16

Dismantling and Disposal Principles Operating instructions for FAS Manual Brass Shut-off Valve DN10 through DN22 To dismantle the valve, shut off the system, remove the refrigerant from the system (or system section) in an environmentally friendly manner and sufficiently ventilate the system (or system section). DANGER! Possible escape of refrigerant. Escaping refrigerant may cause most serious injuries. For repairs the system must have the right temperature, free from refrigerant and sufficiently ventilated! Media contact possible, contact with hot/cold surfaces. Burns, frostbites Wear personal protective equipment as prescribed by national regulations during maintenance and inspections. The valve and its components can be recycled. Valve body: Internal parts of valve: Protective spindle cap: Dust caps: brass scrap brass scrap brass scrap plastics (PE) Sh. 14 of 16 Document 90000704 Revision 01

Armaturenwerk Altenburg GmbH Am Weißen Berg 30 04600 Altenburg Telefon +49 (0) 3447-893-0 Telefax +49 (0) 3447-811-10 Internet: E-Mail: http://www.awa-armaturenwerk.de info@awa-armaturenwerk.de Subject to change of: 09.2016 Document 90000704 Revision 01