MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX)

Similar documents
NOTICE WARNING MDX-R3 FOR FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR

MDX-R3 FOR ADJUSTABLE CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE

NOTICE WARNING MDX-R3 FOR FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR

NOTICE WARNING DANGER SDX2 HIGH FLOW SAFETY DRAIN FOR CONCRETE OWNER S MANUAL MAINTENANCE & INSTALLATION GUIDE. VGB 2008 Compliant

NOTICE. SDX HIGH FLOW SAFETY DRAIN For Concrete, vinyl & equalizer pools OWNER S MANUAL & INSTALLATION GUIDE

SKIMMER FOR CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE

SKIMMER FOR CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE

START UP MANUAL MADE IN USA REV US and Foreign patents and patents pending see

Understanding and Compliance of the Virginia Graeme Baker Pool & Spa Safety Act

SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE

SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE

NO WORK. ALL PLAY. NO WORK. ALL PLAY.

Automatic In-floor Cleaning & Circulation System Installation Manual for Vinyl Pools

ANTI-ENTRAPMENT PLAN

GUIDELINE FOR MITIGATING SUCTION HAZARDS IN POOLS

The Virginia Graeme Baker Pool and Spa Safety Act. by and does not necessarily represent the views of the Commission.

WORCESTER COUNTY HEALTH DEPARTMENT PRE-OPENING GUIDE SEMI PUBLIC POOLS 1. POOL WALLS AND BOTTOM SMOOTH, LIGHT COLORED AND EASILY CLEANABLE. (.

BERMUDA GUNITE SKIMMER FOR SWIMMING POOLS

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Swimming Pools, Hot Tubs and Spas

CUSTOMER ASSISTANCE GUIDE BUILDING PERMIT APPLICATION SUBMITTAL REQUIREMENTS

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTALLATION AND OPERATION MANUAL CHEMICAL BYPASS FEEDER General Instructions Regarding All Models

WORCESTER COUNTY HEALTH DEPARTMENT PRE-OPENING GUIDE RECREATIONAL POOLS 2. DECK AND COPING MUST BE IN GOOD REPAIR AND PROPERLY DRAINED. (.

Suction fittings for use in swimming pools, wading pools, spas, hot tubs, and other aquatic facilities.

Aqua Pilot Suction Pool Cleaner

VANISH IN-FLOOR CLEANING SYSTEM LET YOUR POOL DO THE WORK. YOU CAN DO THE PLAY.

I. Site Information. Pump Information

Vessel Installation and Operating Manual

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

VIRGINIA GRAEME BAKER POOL & SPA SAFETY ACT

Installation and Operating Manual

Dan Johnson, CBP Swim, Incorporated Lead Dog Aquatic Consulting

New England Municipal Building Officials Preventing Drowning and Suction Entrapment through Code Compliance

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Cynthia Arias Pollution Control Coordinator

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

ColorLogic Bubbler. Owner s Manual. Contents WFBCUS1100 WFB100

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

U.S. CONSUMER PRODUCT SAFETY COMMISSION WASHINGTON, D.C November 23, 2004

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

Installation/Care/Use Manual

DUAL SUCTION OUTLETS

CIPHI 2017 Annual Education Conference

POOL AND SPA REPLASTERING AND/OR REMODELING REQUIREMENTS

Code Compliance Incorporated

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST

Smart JVA Module WARNING. For use with AquaLink RS systems with rev R firmware or newer.

SEP 100 D.E. SEPARATION TANK

POOL ROVER ST POOL CLEANER Installation Instructions

Swimming Pool Requirements

ROUND ASSEMBLY. Positioning

COMPLIANCE WITH STANDARDS, REGULATIONS AND ORDINANCES

Pool Inspection. Your Street San Diego, California Prepared for: Your Name Prepared by: Priority Inspection Service

REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE

Lincoln County Environmental Health Department 302 North Academy Street, Suite B Lincolnton, NC Phone: Fax:

CAPITAL CONTROLS SERIES NXT3000

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Installation, Operation and Maintenance Manual for Back Pressure Regulator

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

MODEL CCX-AG CURVE STEP / CURVE STEP SYSTEM

Spas Hotels/Resorts Apartments & Condominiums Campgrounds Health Clubs Medical Clinics Waterparks

Installation Operation Maintenance

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Installation and commissioning instructions 255 series and 256 series

Sand Dollar Filter Owner s Manual IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS

Take a closer look at; Parts - Equipment Systems

Booster Pump PB4-60 Replacement Kits

WAKE COUNTY POOL PERMIT PRE-SEASON AUDIT 2014

Welcome to the PMG Educational Program. Sponsored by:

AMITY TWP POOL REQUIREMENTS

O&M Receiving and Inspection. Storage of Water Treatment Media

APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN

IT S TIME TO PLAY! Owner s Guide A&A BUILT-IN POOL CLEANING AND CIRCULATION SYSTEMS

Air Intake Snorkel Kit

CLEAN AND CLEAR PLUS CARTRIDGE FILTER

ASSE International Product (Seal) Listing Program

Chapter 10 SWIMMING POOLS

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

BS Series Basket Strainer

Cristal -Flo II Filter OwnerÕs Manual

The purpose of this brochure is to explain to owners and contractors the City of Burnaby s requirements for private swimming pools.

PUBLIC SPA CHECKLIST. Planning and Building Department City of Mississauga 300 City Centre Drive, 3th Floor Mississauga ON L5B 3C1

Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

FACILITY CONDITION ASSESSMENT

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

CLEARPRO TECHNOLOGY FILTER LATERALS EXTENSION KITS

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

Pressure Dump Valve Service Kit for Series 2300 Units

BADU JET super-sport II

Warning: NEVER ALTER TEST EQUIPMENT

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING

INSTALLATION INSTRUCTIONS Non-Pressurized Tank. Non-Pressurized Tank Part Number: AFCG1PT

Transcription:

Only for Pools with an existing MDX sump ANTI-ENTRAPMENT DEBRIS DRAIN MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX) Safety compliant according to the Virginia Graeme Baker Pool and Spa Safety Act ASME A112.19.8-2007 LISTED MADE IN USA SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR AS A REPLACEMENT FOR MDX DRAINS ONLY U.S. Patent No.: 6,810,537, 7,089,607, 7,178,179 Notice to Installers: Read and follow these instructions. Give these instructions to the facility owner to keep for future reference. Follow all codes and regulations that apply to the design, installation and use of suction outlet fittings. Only for use in pools with an existing MDX or MDX Sump. WARNING: MDX² and SDX must be installed in accordance with Paramount's written instruction manual, and in conformity with applicable Federal, State, Local and Swimming pool industry building and safety codes. MDX0805 004-027-8792-00 REV040109 295 East Corporate Place Suite 100 Chandler, AZ 85225 Toll Free: 1.800.621.5886 Phone: 480.893.7607 Fax: 480.753.3397 Paramount@1Paramount.com www.1paramount.com

IMPORTANT NOTICES: PLEASE READ WARNING KNOWN DROWNING HAZARD. DO NOT GO NEAR THE SUCTION FITTINGS OR DRAINS OF YOUR POOL OR SPA. YOUR HAIR OR BODY MAY BECOME TRAPPED CAUSING PERMANENT INJURY OR DROWNING. DO NOT ENTER THE POOL OR SPA IF SUCTION FITTINGS OR DRAIN COVERS ARE LOOSE, BROKEN, OR MISSING. INSPECT SUCTION FITTING INCLUDING FASTENERS FOR DAMAGE ON TAMPERING BEFORE EACH USE OF THIS FACILITY. WARNING RISK OF SEVERE INJURY OR DROWNING IF SUCTION SYSTEMS ARE NOT INSTALLED PROPERLY! NOTICE TO OWNER: READ, FOLLOW, AND KEEP THESE SAFETY INSTRUCTIONS FOR FUTURE REFERENCE. WARNING THIS POOL MAY HAVE VENT TUBES AS A LAYER OF ANTI-ENTRAPMENT PROTECTION ON THE SUCTION OUTLETS! IF A VENT TUBE IS INSTALLED ON THIS SYSTEM ATTACH THE ENCLOSED WARNING LABELS TO THE VENT PIPE AND CONTROL PANEL AS INSTRUCTED ON PAGE 9 OF THIS MANUAL. IF THIS POOL HAS BEEN WINTERIZED THE VENT MUST BE INSPECTED WHEN STARTING THE POOL FOR THE SEASON. REMOVE THE PLUG FROM THE ATMOSPHERIC VENT PIPE BEFORE ENERGIZING THE POOL PUMP(S)! TEST THE VENT BY BLOCKING THE DRAIN. AIR SHOULD ENTER THE PIPE AND CAUSE THE PUMP TO CAVITATE RELEASING THE SUCTION ON THE DRAIN BLOCK. WARNING ONLY TO BE USED AS A REPLACEMENT FOR AN MDX DRAIN AND MUST BE INSTALLED IN CONJUCTION WITH AN MDX SUMP Suction can pose a serious hazard to swimmers just as electricity can be a hazard. Both are important for proper water filtration and both must be treated with respect. Suction safety begins with a professional design that includes a quality suction system installed by a certified contractor. The MDX² Anti-Entrapment Debris Drain is only available to certified contractors for the same reason certified electricians are required to connect filtration pumps to public utilities; both require proper training and certification to assure no hidden hazards are built into the project. Certified builders will address the following issues when designing and installing a proper filtration system: Properly bond-grounded pumps, time clocks, switches and any other metal in or near water. This is required to address Electrical Shock Hazards. Design the suction piping so there are no single-point suction hazards; single-point suction (one drain) is a leading cause of Body Suction Entrapment Hazards. Note: your certified builder has many effective options for addressing this hazard; they may include dual-drain systems, like MDX², skimmers, gutters, negative edge features and many more products and piping designs known to professionals. Install ASME A112.19.8-2007 listed drains, suction covers and debris removal systems. This is the ONLY approved option for preventing Hair Entrapment Hazards, the leading cause of suction related injuries. Design and install an effective circulation system (including optional cleaning systems), to direct filtered water to all areas and interior surfaces. NOTE: Suction fittings can NOT clean or direct filtered water for proper sanitation; that can only be done on the pressure (return) side of the filtration system. While suction injuries are extremely rare, drowning and diving injuries are far too common and there is little your certified builder can do to eliminate these hazards. You must educate yourself and your guests. Below are some important safety issues every swimmer must know and recognize. PREVENT DROWNING: Watch children at all times, no swimming alone. NO DIVING IN SHALLOW WATER: You can be permanently injured. PREVENT SUCTION ENTRAPMENT: Inspect suction covers before swimming, keep swimmers away from suction fittings, protect long hair, don t swim with loose clothing or large and dangling jewelry. WARNING: MDX² and SDX must be installed in accordance with Paramount's written instruction manual, and in conformity with applicable Federal, State, Local and Swimming pool industry building and safety codes. For technical assistance call 1-800-621-5886 or contact your regional representative. 2008, Paramount Pool & Spa Systems

MDX² RETRO INSTALLATION MANUAL NOTICE Maximum Pump Size: MDX² Retro is rated for a maximum of 90 GPM (340 LPM). While system flow rate will vary with pump size and the Total Head Loss for a given system, virtually any modern pump is capable of exceeding this limit, therefore it is the responsibility of the system designer to make sure it is not possible to exceed 90 GPM (340 LPM). In the event of one suction outlet being completely blocked, the remaining suction outlets serving that system shall have a flow rating capable of the full flow of the pump(s) for the specific suction system. Notice: When replacing the MDX Cover and Funnel Assembly with the MDX² Retrofit cover DO NOT disable the secondary drains or the third layer of protection. The third layer of protection may be another submerged drain or a vent tube. If you do not have a third layer of protection on this system then you will need to add an SVRS or cut the floor of the pool and add a SDX drain teed into the main suction line 3 10 minimum from the MDX. When replacing the MDX be sure to check all other submerged suction outlets in the pool for broken or missing covers, correct or missing screws and compliant covers. Be sure to replace these covers with a SDX or SDX retro covers to bring all suction outlets into compliance. DO NOT INSTALL THE MDX 2 RETRO UNLESS THERE IS AN MDX SUMP AVAILABLE TO ACCEPT THE MDX 2 RETRO. 2.50 Flow vs Head Loss FLOW HEAD LOSS CURVE 2.00 Head Loss (inhg) 1.50 1.00 0.50 0.00 30 40 50 60 70 80 90 100 110 120 130 140 150 Flow (GPM) HYDROSTAT PLUMBING WARNING Hydrostatic Fitting The hydrostatic port inside the MDX² Sump is equivalent to a 2" Threaded Female Adapter and a 2" Slip Fitting Outside the MDX² Sump. Paramount recommends the use of the 2 thread plug provided. Do not use check valves here that are prone to sticking open causing the need to open the drain cover exposing a suction risk. This port is for the purpose of a hydrostat only. Do not install any suction equipment (pump) to this port For technical assistance call 1-800-621-5886 or contact your regional representative. 1

MDX² - CONCRETE DRAIN ASSEMBLY Concrete Drain Assembly (1pc concrete version): 1. Install lower support (#2) onto sump (#1) with 4(four) security screws (#3 and #4) with screw driver security T25. 2. Install upper support (#5) onto lower support (#2) and secure with 8 (eight) security screws (#6). 3. Install the cover (#7) onto the upper support (#5) and secure with 6 (six) security screws (#8) and 2 (two) security screws (#9). Note: Anchor clips not used in Concrete 1 PC installation 004-202-2221-XX MDX² RETRO FOR CONCRETE 1 PC Replace within 05 installed years 9 8 7 6 5 4 2 3 1 Item Part Number Description *1 005-202-2018-00 Sump MDX Concrete - 2½" (must be present in pool) 2 005-202-2064-00 Lower Support 3 Screw No. 10x 2 1/4" Security Head 4 Screw No. 12x 2 3/8" Security Head 5 005-202-2092-XX Upper Support 6 Screw: No. 10X3/4 Security Head 7 005-252-2085-XX MDX 2 Cover (XX=Color Code) 8 Screw: No. 10X3/4 Vinyl Security Head 9 Screw: No. 8X3/8 Security Head 10 Concrete anchors 11 screw 10 x 1 1/4 security head 005-202-2213-00 Screw Pack MDX2 Retro (includes 3,4,6,8,9,10,11) * Not part of MDX² Retro 2

MDX² - CONCRETE DRAIN ASSEMBLY Concrete Drain Assembly (with leveling ring): After draining the pool: 1. Position the Retro Lower Support (001-250-2064-00) over the existing sump as shown in figure 1 and attach with the screws (6) and anchor clips (3) provided by Paramount. (Fig. 1) Fig. 1 2. Using The Retro Lower Support as a template, drill (4) ¼ holes in the concrete. The holes must be drilled at least 1 ½ deep. (Fig. 2) 3. The holes should be clear of any debris left in the bottom. 4. Press in the concrete anchors 001-250-0520-00 supplied by Paramount. The concrete anchors must be pressed in its full length. (Fig. 3) Fig. 2 5. Install the (4) #10 x 1 ¼ screws 001-250-0821-00 provided by Paramount.(Fig. 4) 1.5 6 Install upper support (#9) onto lower support (#4) and secure with 8 (eight) security screws (#10). 7 Install the cover (#11) onto the upper support (#9) and secure with 6 (six) security screws (#13) and 2 (two) security screws (#12). Fig. 3 Fig. 4 3

004-202-2221-XX MDX² RETRO FOR CONCRETE WITH LEVELING RING Replace within 05 installed years 13 12 11 10 8 6 9 7 5 4 3 2 1 Item Part Number Description *1 005-202-2018-00 Sump MDX Concrete - 2½" (must be present in the pool) *2 Leveling Ring 3 005-252-2070-00 Clip Anchor MDX 2 Fiber Retro 4 005-202-2209-00 Lower Support 5 Concrete Anchors 6 Screw No. 10x 2 1/4" Security Head 7 Screw 10 x 1 1/4 Security Head 8 Screw No. 12x 2 3/8" Security Head 9 005-202-2207-00 Upper Support 10 Screw: No. 10X3/4 Security Head 11 005-252-2205-XX MDX 2 Cover (XX=Color Code) 12 Screw: No. 8X3/8 Security Head 13 Screw: No. 10X3/4 005-202-2213-00 Screw Pack MDX 2 Retro (includes item #5,6,7,8,10,12,13,) * Not part of MDX² Retro 4

MDX² - VINYL DRAIN ASSEMBLY Vinyl Drain Assembly: 1. Install lower support (#4) onto sump (#1) with 4 (four) security screws (#2 and #3) with screw driver security T25. 2. Install upper support (#5) onto lower support (#4) and secure with 8 (eight) security screws (#6). 3. Install the cover (#7) onto the upper support (#5) and secure with 6 (six) phillips screws (#8) and 2 (two) phillips screws (#9). Note: Anchor clips not used in Vinyl installation 004-202-2221-XX MDX² RETRO FOR VINYL Replace within 05 installed years 9 8 7 6 5 4 3 2 1 Item Part Number Description *1 005-252-2014-00 Sump Assembly - 2 1/2" (must be present in the pool) 2 Screw: No. 10X2 1/4" Security Head 3 Screw: 12 x 2 3/8" Security Head 4 005-252-2209-00 Lower Support Vinyl/Fiber 5 005-252-2207-00 Upper Support (XX=Color Code) 6 Screw: No. 10X¾ Security Head 7 005-252-2205-XX MDX 2 Cover (XX=Color Code) 8 Screw: No. 8X¾" Vinyl Security Head 9 Screw: No. 8X3/8 Security Head * 005-252-0818-00 Screw: 12-14 x 1 1/2" Vinyl Sump * 005-252-2044-00 Seal Ring * 005-252-0010-00 Vinyl Gaskets (2 pk) # 005-202-2211-00 Screw Pack MDX 2 Vinyl (includes item #s 2, 3, 6, 8, 9) * Not part of MDX² Retro 5

MDX² - FIBERGLASS DRAIN ASSEMBLY Fiberglass Drain Assembly: 1. Install lower support (#5) onto sump (#1) with 6 (six) security screws (#6 and #4) and two anchor clips (#3) (#005-252-2070-00) with screw driver security T25. 2. Install upper support (#7) onto lower support (#5) and secure with 8 (eight) security screws (#8). 3. Install the cover (#9) onto the upper support (#7) and secure with 6 (six) phillips screws (#10) and 2 (two) phillips screws (#11). 004-202-2221-XX MDX² RETRO FOR FIBERGLASS Replace within 05 installed years 11 10 9 8 7 6 5 4 3 2 1 Item Part Number Description *1 005-252-2016-00 Sump Assembly - 2 ½ (must be present in the pool) *2 005-252-2046-00 Seal Ring 3 005-252-2070-00 Clip Anchor MDX2 Fiber Retro 005-252-2209-00 Lower Support 005-252-2207-00 Upper Support 005-252-2205-XX MDX Cover (XX=Color Code) *4 5 Screw: No. 10X2 1/4" Security Head 6 7 Screw: 12 x 2 3/8" Security Head 8 9 Screw: No. 10X¾ Security Head 2 10 Screw: No. 10X¾" Security Head 11 Screw: No. 8X3/8 Security Head * 005-252-0818-00 Screw: 12-14 X 1 1/2" Vinyl/Fiberglass Sump (12 pk) * 005-252-0816-00 Screw: 12-14 X 1" Vinyl/Fiberglass Sump (12 pk) 005-252-0010-00 Gasket (2pk) 005-202-2212-00 Screw Pack MDX2 Fiber (Includes item #s 2,6,8,10,11) * * Mounting Ring * Not part of MDX² Retro 6

MDX² VINYL WINTERIZATION WITH CANISTER If vacuum relief suction outlets are located below freeze line skip steps 1 and 2. 1. Remove grate from second suction and install a 13-¾ blow through plug and blow line to achieve airlock. 2. If 3rd suction line is installed remove grate, install a 13- ¾ blow-through plug and blow line to achieve airlock. 3. Go to canister instructions step 1-4 below. 4. If vent tube is installed, install blow through plug and blow line to achieve airlock. Repeat vacuum out canister. Then complete canister step 5. WITHOUT CANISTER If vacuum relief suction outlets are located below freeze line skip steps 1 and 2. 1. Remove grate from second suction and install a 13-¾ blow through plug and blow line to achieve airlock. 2. If 3rd suction line is installed remove grate, install a 13- ¾ blow-through plug and blow line to achieve airlock. 3. If vent line is installed in main suction line, plug vent line and install blow through plug in pump inlet and blow line to achieve airlock. 4. Lastly, blow vent line to achieve airlock. PARAMOUNT CANISTER WINTERIZATION 1. Remove outer lid, inner lid and basket, clean and dry off, and store in same area as modules 2. Install and secure regular winterization plug in equalizer line of canister to pool at poolside. 3. Install and secure Schrader plug or blow out plug from canister to main drain. Blow out and obtain air lock as previously described, if skimmer is tied into canister, repeat procedure to skimmer. 4. Bottom port of canister to pump may require an extended pipe for ease of blowing out. Install and blow out line from canister to pump. Install and secure plug in pump. Using a wet/dry shop vac, remove all water from within canister components. 5. Extension pipe can be removed and replaced with plug or Gizmo type container if Gizmo not used. Be sure to install device to absorb ice expansion in canister area. Failure to do this may result in potential ice freeze damage to canister. Winterization anti-freeze is to be used as necessary or when required. Additional questions should be forwarded to Paramount's corporate office at 800.621.5886. TEST PLUGS 2" GALV. SQ. HEAD TO MAIN DRAIN Fig. 8 BALANCE LINE TO OPTIONAL SKIMMER OR VENT LINE USE STANDARD SKIMMER PLUG WRENCH VENT TUBE WARNING LABELS (Figures 8 and 9) Included in each MDX² are two warning labels that need to be placed on the pool equipment if the pool is to be winterized and has a vent tube on any of the drains plumbed on the pool. Attach the smaller label to the vent pipe where it terminates to atmosphere. (See Fig. 8) Fig. 9 Attach the larger label to the control panel next to the controller for the pump with the vent tube plumbed to it. (See Fig. 9) For technical assistance call 1-800-621-5886 or contact your regional representative. WARNING: MDX² and SDX must be installed in accordance with Paramount's written instruction manual, and in conformity with applicable Federal, State, Local and Swimming pool industry building and safety codes. 7

Notes 8

Notes 9