Continuous Gas Analysis. ULTRAMAT 6, OXYMAT 6 Safety Manual. Introduction 1. General description of functional safety 2

Similar documents
SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 /

YT-300 / 305 / 310 / 315 / 320 / 325 Series

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Safety Manual VEGAVIB series 60

Safety Manual OPTISWITCH series relay (DPDT)

Safety Manual VEGAVIB series 60

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

Special Documentation Proline Promass 80, 83

Safety manual for Fisher GX Control Valve and Actuator

Ultima. X Series Gas Monitor

Solenoid Valves used in Safety Instrumented Systems

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

DeZURIK Double Block & Bleed (DBB) Knife Gate Valve Safety Manual

Commissioning and safety manual

Neles ValvGuard VG9000H Rev 2.0. Safety Manual

Pneumatic QEV. SIL Safety Manual SIL SM Compiled By : G. Elliott, Date: 8/19/2015. Innovative and Reliable Valve & Pump Solutions

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

Eutectic Plug Valve. SIL Safety Manual. SIL SM.015 Rev 0. Compiled By : G. Elliott, Date: 19/10/2016. Innovative and Reliable Valve & Pump Solutions

FP15 Interface Valve. SIL Safety Manual. SIL SM.018 Rev 1. Compiled By : G. Elliott, Date: 30/10/2017. Innovative and Reliable Valve & Pump Solutions

DeZURIK. KSV Knife Gate Valve. Safety Manual

High Integrity Pressure Protection Systems HIPPS

Hydraulic (Subsea) Shuttle Valves

Bespoke Hydraulic Manifold Assembly

Solenoid Valves For Gas Service FP02G & FP05G

Section 1: Multiple Choice

SPR - Pneumatic Spool Valve

Neles trunnion mounted ball valve Series D Rev. 2. Safety Manual

Safety Manual VEGASWING 61, 63. NAMUR With SIL qualification. Document ID: 52084

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company

Accelerometer mod. TA18-S. SIL Safety Report

L&T Valves Limited SAFETY INTEGRITY LEVEL (SIL) VERIFICATION FOR HIGH INTEGRITY PRESSURE PROTECTION SYSTEM (HIPPS) Report No.

Rosemount 2130 Level Switch

Vibrating Switches SITRANS LVL 200S, LVL 200E. Safety Manual. NAMUR With SIL qualification

Reliability of Safety-Critical Systems Chapter 3. Failures and Failure Analysis

SIL explained. Understanding the use of valve actuators in SIL rated safety instrumented systems ACTUATION

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03

Jamesbury Pneumatic Rack and Pinion Actuator

Section 1: Multiple Choice Explained EXAMPLE

Transmitter mod. TR-A/V. SIL Safety Report

Failure Modes, Effects and Diagnostic Analysis

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

High performance disc valves Series Type BA, BK, BW, BM, BN, BO, BE, BH Rev Safety Manual

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, MN USA

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

Rosemount 2120 Level Switch

Service & Support. Questions and Answers about the Proof Test Interval. Proof Test According to IEC FAQ August Answers for industry.

Failure Modes, Effects and Diagnostic Analysis

PL estimation acc. to EN ISO

Functional safety. Functional safety of Programmable systems, devices & components: Requirements from global & national standards

Failure Modes, Effects and Diagnostic Analysis

Valve Communication Solutions. Safety instrumented systems

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, Minnesota USA

Implementing IEC Standards for Safety Instrumented Systems

Failure Modes, Effects and Diagnostic Analysis

Understanding safety life cycles

Understanding the How, Why, and What of a Safety Integrity Level (SIL)

Failure Modes, Effects and Diagnostic Analysis

Every things under control High-Integrity Pressure Protection System (HIPPS)

New Thinking in Control Reliability

SIL Safety Manual for Fisherr ED, ES, ET, EZ, HP, or HPA Valves with 657 / 667 Actuator

Failure Modes, Effects and Diagnostic Analysis

Reliability of Safety-Critical Systems Chapter 4. Testing and Maintenance

Functional Safety SIL Safety Instrumented Systems in the Process Industry

H250 M9 Supplementary instructions

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

Transducer mod. T-NC/8-API. SIL Safety Report

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

GasSense NDIR User Manual

Applications & Tools. Evaluation of the selection of a safetyrelated mode using non-safety-related components

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

PROCESS AUTOMATION SIL. Manual Safety Integrity Level. Edition 2005 IEC 61508/61511

Session One: A Practical Approach to Managing Safety Critical Equipment and Systems in Process Plants

What safety level can be reached when combining a contactor with a circuitbreaker for fail-safe switching?

Achieving Compliance in Hardware Fault Tolerance

THE IMPROVEMENT OF SIL CALCULATION METHODOLOGY. Jinhyung Park 1 II. THE SIL CALCULATION METHODOLOGY ON IEC61508 AND SOME ARGUMENT

EMERGENCY SHUT-DOWN RELIABILITY ADVANTAGE

Partial Stroke Testing. A.F.M. Prins

SPECIAL PRINT. Innovative Control Technology. Safety in the Process Industry. SAMSON AG Manuel Hinkelmann Marcel Richter Monika Schneider

GAS FUEL VALVE FORM AGV5 OM 8-03

The Key Variables Needed for PFDavg Calculation

Special Documentation Liquiphant M/S with electronic insert FEL56 + Nivotester FTL325N

THE CANDU 9 DISTRffiUTED CONTROL SYSTEM DESIGN PROCESS

Failure Modes, Effects and Diagnostic Analysis

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic

Competence in Functional Safety

innova-ve entrepreneurial global 1

Failure Modes, Effects, and Diagnostic Analysis of a Safety Device

The IEC61508 Operators' hymn sheet

Session: 14 SIL or PL? What is the difference?

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Instrumented Safety Systems

1 General information Device description Scope Task definition Explosion protection, Device variants...

Application Note. Safety Sub-function PUS Category 1, up to PL c. Application Note PUS, Category 1, up to PL c M20 S22 R20 M1 Q20

Transcription:

Introduction 1 General description of functional safety 2 Continuous Gas Analysis ULTRAMAT 6, OXYMAT 6 Device-specific safety instructions 3 List of abbreviations A Operating Instructions Supplement to instruction Manuals ULTRAMAT 6, OXYMAT 6 OXYMAT 61 12/2014 A5E00695577-05

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY Order number: A5E00695577 P 11/2014 Subject to change Copyright Siemens AG 2005-2014. All rights reserved

Table of contents 1 Introduction... 7 1.1 Purpose of this document... 7 1.2 Device variants... 7 1.3 Additional documentation... 8 1.4 History... 8 1.5 Further information... 9 2 General description of functional safety... 11 2.1 Safety-instrumented system... 11 2.2 Safety integrity level... 12 3 Device-specific safety instructions... 15 3.1 Applications... 15 3.2 Safety function... 15 3.3 Settings... 16 3.4 Behavior in case of faults... 17 3.5 Maintenance and checks... 18 3.6 Safety characteristics... 19 3.7 OXYMAT 61... 19 A List of abbreviations... 21 Glossary... 23 Operating Instructions, 12/2014, A5E00695577-05 5

Table of contents 6 Operating Instructions, 12/2014, A5E00695577-05

Introduction 1 1.1 Purpose of this document This document contains all information and safety instructions required when using an ULTRAMAT 6, OXYMAT 6, ULTRAMAT/OXYMAT 6 or OXYMAT 61 gas analyzer in safetyinstrumented systems. It addresses system planners, constructors, service and maintenance engineers and any personnel commissioning and operating the device. 1.2 Device variants There are the following types of analyzers: Stand alone ULTRAMAT 6 analyzers Stand alone OXYMAT 6 analyzers Stand alone OXYMAT 61 analyzers Units with two analyzers ULTRAMAT 6 Units with two analyzers ULTRAMAT 6/OXYMAT 6 The term 'Gas analyzer' is used for all these types of devices. Features which apply to only one or some of these types are accordingly marked. This safety manual applies only to the analyzer types listed in the following table with the additional order code 'Z+C20'. Table 1-1 ULTRAMAT and OXYMAT 6 types Analyzer name Design Standard analyzer Special analyzer ULTRAMAT 6F 1 channel (IR) 7MB2111 ULTRAMAT 6F 2 channels (1 x 2 IR) 7MB2112 ULTRAMAT 6E 1 channel (IR) 7MB2121 ULTRAMAT 6E 2 channels (2 x 1 IR) 7MB2123 ULTRAMAT 6E 2 channels (1 x 2 IR) 7MB2124 3 channels (1 x 1 IR, 1 x 2 IR) ULTRAMAT 6E 4 channels (2 x 2 IR) ULTRAMAT/OXYMAT 6E 2 channels (1 IR, 1 O2) 7MB2023 ULTRAMAT/OXYMAT 6E 3 channels (2 IR,1 O2) 7MB2024 OXYMAT 6F 1 channel (O2) 7MB2011 7MB2017 OXYMAT 6E 1 channel (O2) 7MB2021 7MB2027 OXYMAT 61 1 channel (O2) 7MB2001 Operating Instructions, 12/2014, A5E00695577-05 7

Introduction 1.3 Additional documentation 1.3 Additional documentation This document deals with the ULTRAMAT 6, OXYMAT 6 and OXYMAT 61 gas analyzers exclusively as part of a safety function. This document is valid only in conjunction with one of the following documents: No. Designation Order no. /1/ Instruction Manual ULTRAMAT 6 and OXYMAT 6 C79000-G5276-C143 (English) C79000-G5200-C143 (German) C79000-G5277-C143 (French) C79000-G5272-C143 (Italian) C79000-G5278-C143 (Spanish) /2/ Operating Instructions OXYMAT 61 A5E00123067 (English) A5E00123066 (German) A5E00123068 (French) A5E00123069 (Spanish) A5E00123070 (Italian) 1.4 History The following table shows the released versions and the changes in the documentation compared to each preceding edition: Edition 01 10/2005 02 07/2010 03 10/2013 04 07/2014 05/ 12/2014 Remark First edition Certificate of conformity updated OXYMAT 61 introduced ULTRAMAT 6 and OXYMAT 6 s united in one document SIL 2 relevant ULTRAMAT device numbers (MLFB) specified 8 Operating Instructions, 12/2014, A5E00695577-05

Introduction 1.5 Further information 1.5 Further information Information The contents of these instructions shall not become part of or modify any prior or existing agreement, commitment or legal relationship. All obligations on the part of Siemens AG are contained in the respective sales contract which also contains the complete and solely applicable warranty conditions. Any statements contained herein do not create new warranties or modify the existing warranty. The content reflects the technical status at the time of printing. We reserve the right for technical changes in the course of further development. References If further information on an aspect described here is referenced to, the corresponding reference will always be found at the end of a section under "See also". Operating Instructions, 12/2014, A5E00695577-05 9

Introduction 1.5 Further information 10 Operating Instructions, 12/2014, A5E00695577-05

General description of functional safety 2 2.1 Safety-instrumented system This chapter describes the functional safety in general and not specific to a device. The devices in the examples are selected as representative examples. System description The sensor (analyzer), automation system and final controlling element combine to form a safety-instrumented system, which executes a safety function. Functional principle The transmitter (analyzer) generates a process-related measured value that is transferred to the automation system. The automation system monitors this measured value. If the measured value exceeds the range of the high or low limit, the automation system generates a shutdown signal for the connected final controlling element, which switches the associated valve to the specified safety position. Special characteristics Four freely-programmable measuring ranges per component, also with suppressed zero All measuring ranges are linear The isolated analog output is set to 4 to 20 ma (NAMUR) Operating Instructions, 12/2014, A5E00695577-05 11

General description of functional safety 2.2 Safety integrity level 2.2 Safety integrity level Definitions SIL, Safety Integrity Level The international standard IEC 61508 defines four discrete Safety Integrity Levels (SIL) from SIL 1 to SIL 4. Each level corresponds to the probability range for the failure of a safety function. The higher the SIL of the safety-instrumented system, the higher probability that the required safety function will work. The achievable SIL is determined by the following safety characteristics: Average probability of dangerous failure of a safety function in case of demand (PFDAVG) Hardware fault tolerance (HFT) Safe failure fraction (SFF) Description The following table shows the dependency of the SIL on the average probability of dangerous failures of a safety function of the entire safety-instrumented system" (PFDAVG) The table deals with "Low demand mode", i.e. the safety function is required a maximum of once per year on average. Table 2-1 SIL Safety Integrity Level Interval 4 10-5 PFDAVG < 10-4 3 10-4 PFDAVG < 10-3 2 10-3 PFDAVG < 10-2 1 10-2 PFDAVG < 10-1 The "average probability of dangerous failures of the entire safety-instrumented system" (PFDAVG) is normally split between the three sub-systems in the following figure. Figure 2-1 PFD distribution 12 Operating Instructions, 12/2014, A5E00695577-05

General description of functional safety 2.2 Safety integrity level The following table shows the achievable Safety Integrity Level (SIL) for the entire safetyinstrumented system for type B subsystems depending on the proportion of safe failures (SFF) and the hardware fault tolerance (HFT). Type B subsystems include sensors with positioners, actuators with complex components, e.g. microprocessors (see also IEC 61508, Section 2). Table 2-2 Achievable Safety Integrity Level (type B subsystems) SFF HFT 0 1 (0) * 2 (1) * < 60 % Not allowed SIL 1 SIL 2 60... 90 % SIL 1 SIL 2 SIL 3 90... 99 % SIL 2 SIL 3 SIL 4 > 99 % SIL 3 SIL 4 SIL 4 * As per IEC 61511-1, Section 11.4.4 Operational reliability According to IEC 61511-1, Section 11.4.4, the hardware fault tolerance (HFT) can be reduced by one (values in brackets) for transmitters and final controlling elements with complex components if the following conditions are applicable to the device: The device is based on prior use. The user can configure only the process-related parameters, e.g. control range, signal direction in case of a fault, limiting values, etc. The configuration level of the firmware is blocked against unauthorized operation. The function requires SIL of less than 4. The device fulfills these conditions. Operating Instructions, 12/2014, A5E00695577-05 13

General description of functional safety 2.2 Safety integrity level 14 Operating Instructions, 12/2014, A5E00695577-05

Device-specific safety instructions 3 3.1 Applications The gas analyzers are suitable for use in a safety-instrumented function of Safety Integrity Level (SIL) 2 in low demand mode within a 1oo1 architecture. The proven in-use-assessment was carried out by RISKNOWLOGY according to IEC 61508 / IEC 61511. Product revisions will be carried out by the manufacturer in accordance with IEC 61508. The gas analyzers are usable in safety applications to monitor limits. 3.2 Safety function The gas analyzers are mainly used for user defined threshold monitoring. Only the 4 to 20 ma analog output (NAMUR) may be used as part of a safety-instrumented function (SIF). In addition to the application-specific measurement error, an additional safety accuracy of 5 % of the maximum measurement range must be added. The total tolerance (safety function) is calculated as follows: Total tolerance (safety function) = ± [application-specific measuring error + 5% safety accuracy] Safety Accuracy of the gas analyzers: the maximum effect of a single failure on the measured value, which is classified to have no effect. NOTICE Loss of safety function The mandatory settings and conditions are listed in the "Settings (Page 16)" and "Safety characteristics (Page 19)" sections. These conditions must be adhered to in order to fulfill the safety function. When the safety function has been executed the safety-instrumented systems shall be brought to a safe state. The Mean Time To Restoration (MTTR) is 8 hours. Reference Instruction manuals ULTRAMAT 6/OXYMAT 6 and OXYMAT 61 (see section Additional documentation (Page 8) for order nos.) See also Settings (Page 16) Safety characteristics (Page 19) Additional documentation (Page 8) Operating Instructions, 12/2014, A5E00695577-05 15

Device-specific safety instructions 3.3 Settings 3.3 Settings After assembly and commissioning in line with the device manual, the following parameter settings shall be made when the devices is used as part of a SIF: Safety parameters Enter the following parameter via user menu: Function number Function Action 24 AUTOCAL/-check Submenu 'AUTOCAL/-check mode': Parameter AUTOCAL/-check on/off' must be set to 'off' 70 Analog output Select setting 'NAMUR/4-20 ma' 77 Store analog output Set 'analog output to 21 ma' Set 'store on/off' to 'on'' Reference ULTRAMAT 6/OXYMAT 6 Manual, OXYMAT 61 Operating instructions Protection against configuration changes After configuration, the analyzer access codes (function 79) shall be changed such that the device is protected against unintentional and unauthorized changes/operation. Checking the safety function after installation Following installation and commissioning of the analyzer a safety function test has to be carried out as described in chapter 5 "Operation" and chapter 6 "Maintenance" of the instruction manual. ULTRAMAT 6: In versions with purged reference gas side the same gas should be used as zero gas and reference gas, e. g N2. Using zero gas, 4 ma must be measured at analog output. For the test of the safety function it is fundamental to use a second calibration gas with a defined proportion of the span gas. The results of the measurement must be within a range of ±5 % (full span) of the expected result. OXYMAT 6: Use zero gas as reference gas. You can also use as zero gas from the same source as the reference gas. In that case make sure that the reference gas pressure remains stable during the zero gas calibration. Using zero gas, 4 ma must be measured at analog output. For the test of the safety function it is fundamental to use a second calibration gas with a defined proportion of oxygen. The results of the measurement must be within a range of ±5 % (full span) of the expected result. 16 Operating Instructions, 12/2014, A5E00695577-05

Device-specific safety instructions 3.4 Behavior in case of faults 3.4 Behavior in case of faults Faults The procedure in case of faults is described in the manual or the operating Instructions of the device. Repairs Defective devices should be sent to the repair department stating details and cause of any fault. When ordering replacement devices, specify also the serial number of the original device. The serial number can be found on the nameplate. Reference Addresses of the responsible repair center, contact partners, spare parts lists etc. can be obtained from the ULTRAMAT 6 and OXYMAT 6 Manual and from the OXYMAT 61 Operating instructions as well as from the following web address: Services & Support (http://www.siemens.com/automation/service&support). The SIL declaration and other manuals can be obtained from the following web address: SIL (www.siemens.com/sil). Operating Instructions, 12/2014, A5E00695577-05 17

Device-specific safety instructions 3.5 Maintenance and checks 3.5 Maintenance and checks Checking the analyzer functions We strongly recommend to check the function capability of the gas analyzers at regular intervals of at least three months. Such a test shall comprise at least the basic functions as described in the ULTRAMAT 6 and OXYMAT 6 manual and in the OXYMAT 61 operating instructions. Functional safety proof test You should regularly check the safety function of the entire safety circuit according to IEC 61508/61511. The test interval is determined during calculation of each individual safety circuit in a system (PFDAVG). The recommended testing interval depends largely on the application but should never exceed three months. We strongly recommend to execute proof test 1 every three months proof test 2 every month. To detect dangerous faults the analyzer analog output and analog input shall be checked with the following tests: Table 3-1 Proof test 1 Step Action 1 Bypass the safety PLC or take another appropriate action to avoid a false trip. 2 Generate or simulate an alarm condition to force the gas analyzer to exceed the high alarm current output limit and verify the analog current value (e.g. by disconnecting pressure / temperature input). 3 Generate or simulate an alarm condition to force the gas analyzer to exceed the low alarm current output limit and verify the analog current value (e.g. by disconnecting pressure / temperature input). 4 Restore the loop to full operation. 5 Remove the bypass from the safety PLC and restore to normal operation. Table 3-2 Proof test 2 Step Action 1 Bypass the safety PLC or take another appropriate action to avoid a false trip. 2 Perform a two-point calibration of the gas analyzer. 3 Perform a reference measurement with at least one measuring point between minimum and maximum concentration. To do so use a calibration gas with a well-known gas concentration. The expected result shall not have a tolerance of more than 2 %. 4 Restore the loop to full operation. 5 Remove the bypass from the safety PLC and restore to normal operation. Both proof test parts will detect more than 90% of possible "du" failures of the gas analyzers. 18 Operating Instructions, 12/2014, A5E00695577-05

Device-specific safety instructions 3.6 Safety characteristics 3.6 Safety characteristics The safety characteristics necessary for use of the system are listed in the SIL declaration of conformity. These values apply under the following conditions: The user shall take care that during the measuring procedure the reference gas overpressure complies to the specified values. The user is responsible for a sufficient measuring gas and reference gas flow according to the values specified in the manuals. The gas analyzer is only used in safety-related systems in low demand mode for the safety function. The safety-related parameters/settings as described in section Settings (Page 16) have been input by local operation and checked before starting safety-instrumented operation. The gas analyzer is blocked against unintentional and unauthorized changes/operations. The average temperature observed over a long period did not exceed 40 C (104 F). All used materials are compatible with process conditions. The MTTR after a device fault is 8 hours. The best time to react on a dangerous detected failure is 1 hour. The logic solver (PLC) has to be configured to detect low range (<3.6 ma) and high range >21 ma) failures of the gas analyzer (fail low and fail high) and will recognize these as an internal failure of the devices and not cause a spurious trip. The AUTOCAL/-check functionality must be deactivated by setting the 'AUTOCAL/-check on/off' switch to 'off' 3.7 OXYMAT 61 When operating an OXYMAT 61 gas analyzer consider additionally that the measuring features of the OXYMAT 61 compared to the OXYMAT 6 and ULTRAMAT 6 analyzers are inferior in the following aspects: higher influence of the ambient temperature on measured values no compensation of vibrations Operating Instructions, 12/2014, A5E00695577-05 19

Device-specific safety instructions 3.7 OXYMAT 61 20 Operating Instructions, 12/2014, A5E00695577-05

List of abbreviations A Abbreviations Abbreviation Full term Meaning > Greater than Mathematical sign for inequality < Less than Mathematical sign for inequality ± Plus-minus sign Mathematical sign that indicates a tolerance in both directions of the referenced value % Percent Mathematical sign for the hundredth part of a whole DC Diagnostic Coverage Parameter which describes the ratio of the failure rate of detected dangerous failures to the failure rate of all dangerous failures. "du" Dangerous undetected Dangerous undetected failures FMEDA Failure Modes, Effects and Diagnostic Analysis Method to determine out of an overall failure rate of a system the proportion of failures without the potential to bring the safetyinstrumented system into a dangerous or impermissible functional status (SFF) and the diagnostic coverage (DC) according to the requirements to IEC 61508. HFT Hardware Fault Tolerance Capability of a function unit to continue execution of a required function in the presence of faults or deviations. IEC International Electrotechnical Commission An international standards organization dealing with electrical, electronic and related technologies I/O Input/Output I/O refers to the communication between an information processing system (such as a computer), and the outside world, such as a human, or another information processing system. Inputs are the signals or data received by the system, and outputs are the signals or data sent from it. IR Infrared Gas detection method using an infrared source to detect and measure infrared-sensitive gases. ma Milliampere A unit of electrical current MLFB Maschinenlesbare Fabrikatebezeichnung German for Machine-readable product identification, a product code MTBF Mean Time Between Failures Average period between two failures MTTR Mean Time To Restoration Average period between the occurrence of a fault on a device or system and the restoration of a flawless state N2 Nitrogen (molecular formula) Chemical element with atomic number 7 and represented by the symbol N. Its name derives from the Greek roots νίτρον (sodium carbonate) and -γενής (producer, literally begetter), because at the time of naming, the word 'nitre' was mistakenly used for sodium salts. At standard temperature and pressure, two atoms of the element bind to form dinitrogen, a colorless, odorless, tasteless diatomic gas with the formula N2. In this case: a component used as reference gas Operating Instructions, 12/2014, A5E00695577-05 21

List of abbreviations Abbreviation Full term Meaning NAMUR Normenarbeitsgemeinschaft für Mess- und Regeltechnik NAMUR is an international user association of automation technology in process industries O2 Oxygen (molecular formula) Chemical element with atomic number 8 and represented by the symbol O. Its name derives from the Greek roots ὀξύς (acid, literally "sharp", referring to the sour taste of acids) and -γενής (producer, literally begetter), because at the time of naming, it was mistakenly thought that all acids required oxygen in their composition. At standard temperature and pressure, two atoms of the element bind to form dioxygen, a colorless, odorless, tasteless diatomic gas with the formula O2. In this case: a measuring component PFD Probability of Failure on Demand Probability of dangerous failures of a safety function on demand PFDAVG Probability of Failure on Demand (AVERAGE) Average probability of dangerous failures of a safety function on demand PLC Programmable Logic Controller A digital computer used for automation of industrial processes, such as machinery control in factories SFF Safe Failure Fraction Proportion of safe failures: Proportion of failures without the potential to bring the safetyinstrumented system into a dangerous or impermissible functional status. SIF Safety Instrumented Function Function to be implemented by a safety-related system or an external risk reduction facility, which is intended to achieve or maintain a safe state for the process, with respect to a specific hazardous event SIL Safety Integrity Level The international standard IEC 61508 defines four discrete Safety Integrity Levels (SIL 1 to SIL 4). Each level corresponds to a probability range for failures of a safety function. The higher the Safety Integrity Level of the safety-instrumented system, the lower the probability that it will not execute the required safety functions. XooY X out of Y voting Classification and description of the safety-instrumented system in terms of redundancy and the selection procedures used in which - Y specifies how often a safety function is executed (redundancy) and - X determines how many channels have to work correctly. Example: Pressure measurement in a 1oo2 architecture: A safety instrumented-system decides that a specified pressure limit has been exceeded if one out of two pressure sensors reaches this limit. In a 1oo1 architecture, there is only one pressure sensor. 22 Operating Instructions, 12/2014, A5E00695577-05

Glossary Dangerous failure Failure with the potential to bring the safety-instrumented system into a dangerous or nonfunctional status Low Demand Mode The frequency of demands for operation made on a safety-related system is not more than one per year and not more than twice the proof-test frequency. Safety function Defined function executed by a safety-instrumented system with the objective of achieving or maintaining a safe system status which takes into account a defined occurrence of dangerous failures. Example: Monitoring of user-defined limit values. Safety Integrity Level See SIL Safty-instrumented system A safety-instrumented system excludes the safety functions that are required to achieve or maintain a safe status in a system. It consists of a sensor, a logic unit/control system and a final controlling element. Example: A safety-instrumented system is made up of a pressure transmitter, a limit signal sensor and a control valve. SIL The international standard IEC 61508 defines four discrete Safety Integrity Levels (SIL) from SIL 1 to SIL 4. Each level corresponds to a probability range for the failure of a safety function. The higher the SIL of the safety-instrumented system, the higher the probability that the required safety function will work. The achievable SIL is determined by the following safety characteristics: Average probability of dangerous failure of a safety function in case of demand (PFDAVG) Hardware fault tolerance (HFT) Safe failure fraction (SFF) Operating Instructions, 12/2014, A5E00695577-05 23

Glossary 24 Operating Instructions, 12/2014, A5E00695577-05