CYLINDERS HYDRAULIC HOIST CYLINDERS

Similar documents
Index Table. Model 794. Installation, Operating and Maintenance Instructions

CSA Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

REACH COMPLIANT 2500 WEIGEL STREET CADILLAC, MI

Color/Catalyst Dispense Valves

Introduction INDEX. INTRODUCTION HSE

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: HD26248

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

DAKOTA 2006 DUMP BOX ILLUSTRATED PARTS MANUAL

Model ASSEMBLY and OPERATING INSTRUCTIONS

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

REV0709. Parts List. Hydraulic Cylinder Model MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER. Max. Capacity: 55.2 Tons at 10,000 PSI

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

The Enerpac Lightweight Aluminum Cylinders

BVM CORPORATION TYPE AAX TONG 55,000 FT/LBS. TORQUE Part number: Serial Number:

2000 lb manual winch

VENTILATOR OPTIONS. Please visit our web page to view all the available options and for a specification.

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

HEAVY DUTY PNEUMATIC

ALF400 to 900, ALT-5/-9

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Pressure Relief Valve Instruction Manual

TWO POST RAM PACKAGE 55 GALLON

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

SASK-A-POLE OWNERS AND USERS MANUAL

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

AIR INLINE METAL SHEAR

Technical Data Sheet TI-F50 Locking Units series KFH

Models: C62/63/64-A/D

Right-Angle Tube Roller Model

ATEX ATEX

World Area Differences Technical Information

Techcon Systems TS1254 Pressure Pot

This document to be used with Hurley traditional Davits

Берг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC.

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

ALF400 to 900, ALT-5/-9

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

OPERATION AND INSTRUCTION MANUAL

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

453 Series Steam Heated Vaporizing Regulator

AIR/OVER HYDRAULIC JACK 20 TON

OPERATION AND INSTRUCTION MANUAL ROLLER SLING Model: IN106.3FT & IN106.2FT

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Tools & Installation. Tools & Installation Index

Installation Instructions

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

FLANGED TWO-PIECE BALL VALVES

KM/31000 (Stainless steel end plates) Air bellows, single acting

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Coiling Tube with Twist-Proof Fitting

6146XX-X OPEN STYLE HOSE REELS

SC HYDRAULIC ENGINEERING CORPORATION

FLOW CONTROL & AIR PILOT SWITCH VALVES

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

Vertical and Horizontal Bladder Tanks

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

WEATHERIZING INSTRUCTIONS

Cylinder Tilt Saddle Instruction Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

TONS! powerteam.com HEAVY LIFT CYLINDERS

09 - Choosing /sizing a cylinder and valve

Installation and Maintenance Manual. Dual Medical Gas Outlets

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Technical Data Sheet TI-F52 Locking Unit KFHL Certified by Lloyd s Register

SUPER SLIDER BEAM ANCHOR ADJUSTABLE FROM Model # BWA030N

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

AUTOMATED INDUSTRIAL MACHINE, INC

ENGINEERING DESIGN GUIDE. D-M-E Hydraulic Unscrewing Device

Pilot Check Valve: Metal Body Type

OR-V 40 P BETRIEBSANLEITUNG DEUTSCH ENGLISH FRANÇAIS ITALIANO MODE D'EMPLOI ISTRUZIONI PER L'USO

STAND AID 1600/ ECONOSTAND

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

OPERATION AND INSTRUCTION MANUAL Beam Trolley Model: BTA012N

30T A/Manual Hydraulic Shop Press

F l o w c o n T R o l v a l v E S

USER GUIDE G Series telescopic cylinder

DI-DRO ADVANCED FORMING SYSTEMS

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

HP-104 & HP-106 Tapping Machine OPERATIONS MANUAL

Part No (Low Changeover) Part No (High Changeover) Part No (High Changeover)

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS

Mini-Mac Applicator Specification Sheet Part No (Replaces )

OPERATIONS MANUAL IMPORTANT SAFETY INFORMATION

ALF400 to 900, ALT-5/-9

// ADapters GUIDelines

AND OPERATION INSTRUCTIONS

Pool Ladder. Owner s Manual For: 36in (91 cm), 42in (107 cm), 48in (122 cm) models. For illustrative purposes only.

Transcription:

CYLINDERS HYDRULIC HOIST CYLINDERS

The combination of strict machining tolerances, solid stop contact faces, and larger overlap between the stages has resulted in one of the strongest and most stable cylinder columns currently available on the market. These improvements help to increase safety for dumping applications, helping to prevent accidents due to vehicle roll-over. Double Lip Seal Double Lip Wipers FETURES ENEFITS Material ll Muncie cylinders are made of hot rolled solid seamless tubes. llow for higher pressures due to higher strength material, no weak points, and Muncie s focus on quality. Increased resistance to mechanical stress and longer life. High Precision Machining Process Solid stop faces are machined into each stage this creates a single solid component with no need for stop rings, bushings or gland nuts. Seals/Wipers Made of polyurethane, with a double lip design, the seals and wipers assure optimum performance in all climate conditions (-40 F to 212 F / -40 C to 100 C). Muncie cylinders do not require packing due to the top quality material, paired with the low tolerance machining of the stages. Sliders Made of DELRIN, they are compatible with all types of hydraulic oils approved by pump makers and are capable of withstanding high and low pressures. Each cylinder is equipped with two sliders at both the top and bottom of each stage. Overlap & Column Strength Two Sliders Per Stage for Top and ottom Chromed Final Stage ll of Muncie s Front End Cylinders have two bottom sliders on each stage to achieve larger overlap. Longer stages have greater overlap to improve column stability on longer strokes. Weight Savings Due to the construction philosophy, Muncie is able to offer one of the lightest solutions available on the market. This results in greater payloads, less oil consumption, and faster dumping. Low Maintenance Easy assembly and disassembly process, due to the low level of components used, along with no need for any special tools allows for easy maintenance. Muncie cylinders are able to be reconditioned at low cost due to the solid machining, high steel grade, and dimensional stability of the cylinder during its work cycle. Muncie cylinders have low maintenance requirements, and offer many years of top performance without additional expenses. Self-leeding Design, reduces time spent maintaining cylinder Chrome Plated Final Stage, extends the life of the cylinder. Two Year Warranty Standard for Muncie Cylinders Grease Zerk Standard both top and ottom Eye Seamless one piece, high tensile tubes Machined end stops with extra overlap High column strength and stiffness Large bearing surface area Robust/high durability design No Packing, or Packing Nuts One Head Nut that does not need adjustments. Tight tolerancing and machining Small tube clearance for smaller bending moment Precision ground finish for optimum performance and seal life Self-leeding Design

DUMP ODY CYLINDER CLCULTIONS MODEL NUMER CONSTRUCTION 8-5 - 265-00 Note: These calculations are provided to provide you with approximate values. Final calculations and product selection should be determined by a qualified engineer and engineering drawing. Series Design Code (8, 7, 6, 5) = Dump hinge pin to center of load in inches Style: Pin to Pin Number of Stages = Dump hinge pin to cylinder base pin in inches Nominal Stroke (in) 5 (8 Series Only) 4 (7 Series Only) 3 (5 & 6 Series Only) D = Dump body to frame angle See next page for standard size availability S = Stroke of cylinder CYLINDER SEL ND REUILD KITS S Stroke Center of Load D Dump ngle CYLINDERS USED WITH seal kit NUMER rebuild kit NUMER 5-3- XXX- 00 GSK-53-00 RK-53-00 6-3- XXX- 00 GSK-63-00 RK-63-00 7-4- XXX- 00 GSK-74-00 RK-74-00 8-5- XXX- 00 GSK-85-00 RK-85-00 PIN-EYE USHINGS FOR TOP PIN OD Dump ngle* D 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57.715.733.750.765.780.797.813.830.845.861.877.892.903.923.939.954 W *Normal minimum dump angle is 45. Normal Maximum dump angle is 57. To calculate the appropriate cylinder stroke to achieve a determined dump angle: To calculate the initial required cylinder force to lift a load: pproximate Stroke (inches) = x D Force required to lift a load = [Load (lbs] x )/ Example: = 162 and Desired Dump ngle = 49 pproximate Cylinder Stroke = 162 x.830 pproximate Cylinder Stroke = 135 Example: Load = 40,000 lbs, = 85, and = 162 Force required = [40,000 lbs x 85 ]/162 Force Required = 20,988 lbs ID PIN-EYE MOUNT SPCERS REF. MODEL STGE DI. EFF. RE (SQ.IN) 800 psi 1,000 psi 1,500 psi 2,000 psi 2,500 psi 8 6.85 36.85 29,482 36,853 55,279 73,706 92,132 Description PRT NUMER 7 6.06 28.84 23,074 28,843 43,264 57,685 72,107 3.00 OD X 1.81 ID X 0.25 W 18T42906-181025 6 5.31 22.15 17,716 22,145 33,218 44,290 55,363 3.00 OD X 1.81 ID X 0.50 W 18T42906-181050 5 4.57 16.40 13,122 16,403 24,604 32,806 41,007 3.00 OD X 1.81 ID X 0.75 W 18T42906-181075 - 3.86 11.70 9,362 11,702 17,553 23,404 29,255 3.00 OD X 1.81 ID X 1.00 W 18T42906-181100 - 3.11 7.60 6,077 7,596 11,395 15,193 18,991 3.00 OD X 2.12 ID X 0.25 W 18T42906-212025 3.00 OD X 2.12 ID X 0.50 W 18T42906-212050 3.00 OD X 2.12 ID X 0.75 W 18T42906-212075 3.00 OD X 2.12 ID X 1.00 W 18T42906-212100 Note: properly designed system should operate at approximately 800 psi or less during the start of the lift. The load imposed on a cylinder by a dump body is dynamic, and as such, your system pressure will be changing to accommodate the difference in force required to lift the changing load. You will see system pressure increase as your cylinder extends from stage to stage. You will also see a decrease in cycle time due to the effective volume change from stage to stage as the cylinder extends (your cylinder will move faster). Description PRT NUMER 2.00 OD X 1.31 ID X 2.00 W 18T42905-131200 2.00 OD X 1.50 ID X 1.50 W 18T42905-150150 2.00 OD X 1.50 ID X 2.00 W 18T42905-150200 2.00 OD X 1.68 ID X 2.00 W 18T42905-168200 2.00 OD X 1.75 ID X 1.50 W 18T42905-175150 2.00 OD X 1.75 ID X 2.00 W 18T42905-175200 OD W ID

ENGLISH UNITS METRIC UNITS (Drawing Dimensions in Inches) R1.57 R1.77 Ø 2.0 Ø 2.0 Ø 5.1 16.50 1.50 R4.50 Ø 5.1 6.50 (Drawing Dimensions in cm) R4.00 1.97 3.80 C 5.00 C ØD 1" NPT 2 Places 1.97 (ll Dimensions Nominal) MODEL NUMER STROKE =CLOSED/ OPEN LENGTH =PORT TO PORT C=SE D=TUE PIN WIDTH OD 5-3-084-00 5-3-104-00 85.91 103.23 39.57/ 125.48 47.32/ 150.55 20.3 28.3 6-3-104-00 6-3-120-00 6-3-126-00 6-3-130-00 6-3-140-00 102.28 118.35 128.46 128.46 135.47 47.32/ 149.6 52.48/ 170.83 54.96/ 183.42 55.75/ 184.21 59.65/ 195.12 28.3 33.5 36.0 36.0 40.4 7-4-135-00 7-4-156-00 7-4-161-00 7-4-167-00 135.67 157.68 162.99 171.42 47.76/ 183.43 52.91/ 210.59 55.39/ 218.38 55.39/ 226.81 8-5-190-00 8-5-220-00 8-5-235-00 8-5-250-00 8-5-265-00 8-5-285-00 188.98 219.92 235.00 246.89 265.83 285.98 53.98/ 242.96 59.88/ 279.8 64.53/ 299.53 68.35/ 315.24 69.72/ 335.55 75.87/ 361.85 ØD 1" NPT 2 Places 5.00 (ll Dimensions Nominal) Stage Dia 1/ 2/ 3/ 4/ 5 Fill/ Extend (GL) Cylinder Weight (lbs) MODEL NUMER STROKE (cm) =CLOSED/ OPEN LENGTH (cm) =PORT TO PORT (cm) C=SE PIN WIDTH (cm) D=TUE OD (cm) Stage Dia (cm) 1/ 2/ 3/ 4/ 5 Fill/ Extend (L) Cylinder Weight (kg) 5.39 5.39 4.57/ 3.86/ 3.11 4.57/ 3.86/ 3.11 0.52/ 4.40 0.62/ 5.26 179 220 5-3-084-00 5-3-104-00 218.2 262.2 100.5/ 318.7 120.2/ 382.4 51.6 71.9 13.69 13.69 11.60/ 9.80/ 7.90 11.60/ 9.80/ 7.90 1.97/ 16.65 2.35/ 19.91 81 100 0.72/ 7.35 0.82/ 8.55 0.88/ 9.24 0.88/ 9.24 0.92/ 9.74 255 280 300 300 320 6-3-104-00 6-3-120-00 6-3-126-00 6-3-130-00 6-3-140-00 259.8 300.6 326.3 326.3 344.1 120.2/ 380.1 133.3/ 433.9 139.6/ 465.9 141.6/ 467.9 151.5/ 495.6 71.9 85.1 91.4 91.4 102.6 2.73/ 27.82 3.10/ 32.36 3.33/ 34.97 3.33/ 34.97 3.48/ 36.87 116 127 136 136 145 27.6 33.5 36.5 36.5 / / / / 1.04/ 11.49 1.19/ 13.43 1.24/ 14.14 1.29/ 14.66 330 365 374 385 7-4-135-00 7-4-156-00 7-4-161-00 7-4-167-00 344.6 400.5 414.0 435.4 121.3/ 465.9 134.4/ 534.9 140.7/ 544.7 140.7/ 576.1 70.0 85.0 92.6 92.6 15.39/ 15.39/ 15.39/ 15.39/ 3.94/ 43.49 4.50/ 50.83 4.69/ 53.52 4.88/ 55.49 150 166 170 175 32.1 39.1 44.9 44.9 48.7 56.8 1.53/ 18.70 1.75/ 21.74 1.89/ 23.34 1.95/ 24.53 2.09/ 26.35 2.28/ 29.55 464 531 584 588 620 690 8-5-190-00 8-5-220-00 8-5-235-00 8-5-250-00 8-5-265-00 8-5-285-00 480.0 558.6 596.9 627.1 675.2 726.4 137.1/ 617.1 152.1/ 710.7 163.9/ 760.8 173.6/ 800.7 177.1/ 852.3 192.7/ 919.1 81.6 99.3 114.1 114.1 123.8 144.3 5.79/ 70.78 6.62/ 82.28 7.15/ 88.34 7.38/ 92.85 7.91/ 99.73 8.63/ 111.85 210 241 265 267 281 313 *ll cylinders MX Pressure: 2750 PSI Due to NPT Ports (Rated for 2900 PSI) *ll cylinders MX Pressure: 189.7 R Due to NPT Ports (Rated for 200 R)

TWO Year CYLINDER Warranty Muncie s single acting telescopic cylinder is warranted against any defect in material and workmanship which existed at the time of sale by Muncie Power Products, Inc., according to the following provisions, subject to the requirements that the cylinder must be used only in accordance with catalog and package instructions. The cylinder is warranted for a period of two years from the date of installation. If during the warranty period the cylinder fails to operate to Muncie s specifications due to a defect in any part, material or workmanship that existed at the time of sale by Muncie, the defective part will be repaired or replaced, at Muncie s election, at no charge, if the defective part is returned to Muncie with transportation prepaid. WRNING: The above warranty shall terminate if any alterations or repairs are made to the cylinder other than at a Service Center owned by Muncie, or if the cylinder is used on any equipment other than the equipment upon which it is first installed. THE FOREGOING WRRNTIES RE IN LIEU OF LL OTHER OLIGTIONS ND LIILITIES, INCLUDING NEGLIGENCE ND LL WRRNTIES OF MERCHNTILITY ND SUITILITY, EXPRESSED OR IMPLIED, ND STTE MUNCIE S ENTIRE ND EXCLUSIVE LIILITY ND THE UYER S EXCLUSIVE REMEDY FOR NY CLIM OF DMGES IN CONNECTION WITH THE SLE, REPIR OR REPLCEMENT OF THE OVE GOODS, THEIR DESIGN, INSTLLTION OR OPERTION. MUNCIE WILL IN NO EVENT E LILE FOR NY DIRECT, INDIRECT, SPECIL, INCIDENTL OR CONSEQUENTIL DMGES WHTSOEVER, ND OUR LIILITY WILL UNDER NO CIRCUMSTNCES EXCEED THE CONTRCT PRICE FOR THE GOODS FOR WHICH LIILITY IS CLIMED. Distributed y: Muncie Power Products MP12-12 Printed in the U.S. Muncie Power Products, Inc. 2012 Muncie Power Products, Inc. Member of the Interpump Hydraulics Group General Offices and Distribution Center P.O. ox 548 Muncie, IN 47308-0548 (765) 284-7721 FX (765) 284-6991 E-mail info@munciepower.com Web site http://www.munciepower.com Drive Products, Inc., Exclusive gents for Canada, ISO Certified by an ccredited Registrar