H 2. Sensor Series Take no risk! Install a Hydrogen Sensor in your Gaschromatograph

Similar documents
Your local gas generation partner. Precision series Modular gas generation solution for GC.

Carrier Gases in Capillary GC

Your local gas generation partner. Precision series Modular gas generation solution for GC.

The. «Modular Alliance» Gas Generators. ALLIANCE, the partnership that keeps the gas flowing. One step ahead!

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

Generating Calibration Gas Standards

During today's webinar we're going to look at the following topics:

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

490 Micro GC Site Preparation Checklist

Carrier Gases in Capillary GC

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

WIKA INSTRUMENT CORPORATION

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

490 Micro GC Site Preparation Checklist

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Super-Clean Gas Filters from Restek

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

3 Flow and Pressure Control

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

CHEM 355 EXPERIMENT 7. Viscosity of gases: Estimation of molecular diameter

PHOENIX L300i Best-in-class Helium Leak Detectors

Columbus Instruments

Constant Pressure Inlet (CCN) Operator Manual

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

INSTRUMENT INSTRUMENT YL INSTRUMENT

IRwin Methane Leak Detector. Innovation makes the difference

VACCUPERM Vacuum chlorine gas dosing systems

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Unit 8: Kinetic Theory Homework Packet (90 points)

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

6890 GC Site Preparation

MODEL GENERA PURGE TURBINE INSTR DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Mass Flow Controller (MFC) for Gases

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

Technical Data Sheet MF010-O-LC

Valve Proving System VDK 200 A S06*

Electronic Volume Correctors

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

Valve Proving System VDK 200 A S02

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

TC65M/15M TEMPERATURE CALIBRATOR USER S MANUAL

This test shall be carried out on all vehicles equipped with open type traction batteries.

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Miniature Electronic Pressure Controllers. Precision Fluidics

CAPITAL CONTROLS SERIES NXT3000

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

AN-03 Rotary valves applications

Flow in a shock tube

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

The University of Hong Kong Department of Physics Experimental Physics Laboratory

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

780S Ultra High Purity Series

DELTI. Vac. DELTI-Vac MIL. Application. Principle. Characteristic

KilnCooler Hot Spot Technical

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Oxygen Measurement in Natural Gas

[Instruments for vacuum measurement, checking and adjustment] 3

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Discovery HP-TGA 75/750. Site Preparation Guide

Flow meter. bellow vaporizer. APL valve. Scavenging system

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

HI 2314 HI 2315 HI 23151

PG9607 Piston Gauge. Automated primary pressure reference for absolute and gauge pressures to 500 kpa

C-Flow Coriolis Mass Flow Meters

User Manual. Quantos Automated Dosing Liquid Module

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Agilent Flow Tracker Series 1000/2000

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

EASIDEW TRANSMITTER with Current Source Output

Equipment. Flowmeter Tutorial

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

FPG8601 Force Balanced Piston Gauge

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Operating Instructions Part No

HumiSys HF High Flow RH Generator

The Preparation of Low Concentration Hydrogen Sulfide Standards Gulf Coast Conference September 12, 2002 Galveston, TX Paper 050,12:45 pm Moody F

Service Test Unit for ROSS Proportional Valves RESK

better measurement Simply a question of

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

Pressure Measurements

The New PHD 4 Portable Helium Detector

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Manual of SF6 Comprehensive Tester

Transcription:

Sensor Series 9000 Take no risk! Install a Hydrogen Sensor in your Gaschromatograph

Carrier Gases for GC Probably more than 90% of the present GC instruments run with helium as carrier gas. Some people use hydrogen or nitrogen, maybe because the first ones are hidden pyromaniacs (some GC ovens actually exploded) and the second still have nitrogen mounted on the instrument from the times they worked with packed columns. These gases serve to produce wind through the column to move our solutes forward. The solute molecules evaporate from the stationary phase surface, i.e. enter the open space of the capillary column, are hit by a carrier gas molecule and start traveling down the tube. After a short distance, however, they touch the sticky surface of the stationary phase and go through another partitioning process. Does the choice of the carrier gas interfere with this? Yes, it does, through its diffusivity and viscosity. You want to know why hydrogen is the best carrier gas? Diffusivity Diffusivity provides a measurement for the diffusion speed of a solute vapor in a given gas. For helium and hydrogen, diffusivities are similar, but that of nitrogen is about four times lower (see Table I). Table I: Relevant characteristics of carrier gases 1 C arrier gas V iscosity at 50 C [kg/s m ] Diffusivity (butane, 100 C [m2s] ) H ydrogen 9. 4 10- For columns of a given diameter, the optimum velocity is highest when the column is short. This is because inlet pressure is low. For hydrogen or helium, with about the same diffusivity, the optimum is almost the same, i.e. around 40-50 cm/s. Further, the losses in performance upon speeding, i.e. using excessive gas velocity, are relatively small. The longer the column, the higher is the inlet pressure required. This shifts the optimum gas speed to lower values and, as if there were a strict educator behind the chromatographer, speeding is punished more strongly when the velocity must be low anyway. Hence, using a column of doubled length requires more than twice as much run time, because the gas velocity must be lower. In this respect, helium is worse than hydrogen because its viscosity is about twice as high: the higher inlet pressure requires a lower gas velocity and if you do not obey, the punishment is harder. What is the reason for this? If the column head pressure is, e.g., 1 bar, corresponding to 2 bar absolute pressure, the carrier gas in the inlet is compressed to half the volume compared to the column outlet (assuming the latter is at ambient pressure, 1 bar absolute, Figure 4). Hence the plug corresponding to 2 ml in the outlet is only 1 ml and is half as long. To displace 1 ml, half the velocity is required compared to displacing 2 ml at the outlet. Hence optimization must compromize between a low velocity in the inlet and a higher one at the outlet. - Figure 4: Compressibility of the carrier gas causes the gas velocity in the inlet to be lower than in the outlet. H elium 20. 8 5.5 10- N itrogen 18. 8 1.5 10- The diffusion speed of the solute in the carrier gas determines the speed of chromatography. A solute molecule evaporating from the stationary phase surface into the gas stream should be given enough time to diffuse back to the stationary phase (Figure 1) before having gone far in order to undergo another partitioning process - it is these contacts which differentiate between different substances, and a large number of contacts are needed to obtain the best separation. We get more of them if the solute diffuses more rapidly and/or when we give it more time, i.e. reduce the gas velocity. However, there is a limit: giving it more time for the diffusion towards the stationary phase (radial diffusion) also provides more time for spreading within the open bore of the column, i.e. for band broadening through longitudinal diffusion. This is why there is an optimum gas velocity: it provides a maximum number of contacts with the stationary phase with a minimum of band broadening in the gas phase. - Figure 3: High inlet pressures cause the optimum gas velocity to be low and the loss in separation efficiency when exceeding this optimum to be high. Conclusions are against intuition. From short columns we know that 40-50 cm/s are best. In the last, e.g., 15 m of a long column, pressure conditions are the same as in a short column, i.e. the optimum gas velocity and tolerance to speeding must be the same. The problem resulting from the compressibility of the gas is obviously in the inlet of the long column. We are tempted to assume that it is related to the fact that the gas velocity is 20-25 cm/s only and would conclude that a compromize should be chosen between maybe 30 cm/ s in the inlet and 70 cm/s in the outlet in order to result in some 50 cm/s as an average. Experiments show that this is wrong: the best average velocity is only 20-25 cm/s. Hence the system wants an even lower velocity in the inlet: about 10 cm/s. And it insists in that: it forces to choose a velocity at the outlet lower than found to be optimum, and if you do not obey to the 10 cm/s in the inlet, punishment is hard. A rapid glance into the above h/u curve shows that 10 cm/s would provide extremely poor performance at the column outlet. Thus the correct conclusion is that optimum velocities are far lower in a compressed gas. This is not really new: GC with vacuum at the outlet, e.g. with GC-MS, is even faster. Nitrogen has only drawbacks and is not suitable for capillary GC. Helium is as good as hydrogen if inlet pressures are below about 50 kpa, but requires slower GC at higher inlet pressures (for longer columns), the difference being roughly a factor of two when 150-200 kpa must be applied for helium. Reprinted from the Restek Advantage, Fall 1997, Copyright 1997 Restek Corporation.

-Sensor for your GC Get all the benefits of hydrogen as carrier gas... without taking the risk. If you want to take full advantage of the power of High Resolution Gaschromatography for your analytical results, then hydrogen will be in most cases the carrier gas of choice. Its low viscosity and excellent mass transfer capabilities results in shorter run times and better separation performances. Beside this hydrog ogen costs about 75% less then helium of comparable able quality. The only drawback is the danger of explosion in case of a leak in the column oven. Take no risk! Install a H 2 -Sensor in your gaschromatograph! The H 2 -Sensor will continuously moni- tor the atmosphere e in the GC-oven. If the present threshold level el is ex- ceeded, an audible alarm is alerted and the alarm starts blinking. The oven is immediately shut off f and the cooling flap opens. In addition the system can switch to nitrog ogen if a gas switching valv alve is provided vided. This will also happens in a event ent of power failure. In case of malfunction of the unit, the opera- tor will be alerted by an exter xternal alarm (op- tional)

-Sensor - Principle of operation A thermostated flow-through semiconductor-type sensor continuously monitors the hydrogen concentration in the GC-oven. The lowest detection limit is 0.5% H 2 by volume and the alarm threshold can be freely set between 0.5% and the lower explosion limit of hydrogen (4% H 2 by volume). If the threshold level is exceeded, an audible alarm will sound and the flashing light on the unit will indicate the presence of hazardous conditions. The sensor allows for a reset only when the concentration of H 2 falls below about 0.8% by volume. Specifications Detection Limit: Alarm threshold: Stability of threshold level: Sensor lifetime: Instrument readings: 0.5% hydrogen by volume Continuously adjustable from 0.5% to 4% by volume (recommended value: 0.8-1.2% by volume) Better than 500 PPM of set value (within one year) At least 5 years (in a non-corrosive environment) Power on/off LED (green bargraph) Display for H 2 concentration Bar graph LED for H 2 -level display Blinking alarm display Audible alarm on/off safety switch (rear side) Outputs: Gasalarm: GA1: 4 pol connector rear side line voltage 230/115 VAC/1A 1 potential free contact (contact closure) 50V/1A 1 TTL output 5V Technical alarm: 1 potential free contact (contact closure) 50V/1A 1 TTL output 5V Others: Sensor analog output 0-1 V linearized Operating temperature: Electronics -5 to +55 C Sensorhead SC: -10 to +80 C EC: -10 to +40 C Power: Calibration: 90-20 VAC - 50/0 Hz Should be checked once a year with a test gas (1.0% by volume) in a corrosive environment this procedure must be repeated more often.

Available systems Passive system: principle: The most of the GC's available on the market have a slight overpressure. This overpressure is used to assure the gas flow trough the sensor head. Active system: principle: H2 Sensor Active system cable to control unit If no overpressure is available in the GC the active system is available. A small fan is installed in the sensor head to assure the gas flow trough the sensor head. Sensor Fan fire protection Ordering Information Part Number Description Passive System SC 9 1000900 H 2 -Sensor Series 9000 SC/PS Active System SC 9 1000920 H 2 -Sensor Series 9000 SC/AS 9 1000801 H 2 autom. switching valve with MB fitting for 1/1 or 2mm tubings 9 1000810 H 2 autom. switching valve with 1/8 fitting for 1/8 tubings 9 1000811 H 2 autom./manual switching valve with MB fitting for 1/1 or 2mm tubings 9 1000812 H 2 autom./manual switching valve with 1/8 fitting for 1/8 tubings 9 1000841 Shut down valve 115V 9 1000842 Shut down valve 220V 9 1000850 Calibration Gas 1 bottle 9 1000851 Calibration Gas 1 pack ( bottles) 9 1000852 Calibration Gas 10 pack (0 bottles) 9 100080 Adapter Kit for calibration gas 9 1000925 Active system fan replacement kit Manufactured by: Ditributed by: E-Mail: sales@brechbuehler.ch Steinwiesenstrasse 3 CH-8952 Schlieren, Switzerland Tel. +41 44 732 31 31 FAX +41 44 730 1 41 http://www.brechbuehler.ch