International Journal of Research in Advent Technology Available Online at:

Similar documents
Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

The Discussion of this exercise covers the following points:

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

485 Annubar Primary Flow Element Installation Effects

Applied Fluid Mechanics

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

Micro Motion Pressure Drop Testing

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate

Experiment 8: Minor Losses

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

ABSTRACT. flotek.g Innovative Solutions in Flow Measurement and Control - Oil, Water and Gas August 28-30, 2017, FCRI, Palakkad, Kerala, India

Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

Cover Page for Lab Report Group Portion. Drag on Spheres

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

Thermal Mass Flowmeters. 5 Mass Flowmeters

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

AerE 343L: Aerodynamics Laboratory II. Lab Instructions

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Gas Measurement Fundamentals Certification. Curriculum

Gerald D. Anderson. Education Technical Specialist

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

CHAPTER 7 : SMOKE METERS AND THEIR INSTALLATIONS

Smoke and heat Ventilator Testing

Operating instructions Pitot Static Tube

A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates

FAN ENGINEERING. Field Testing of Fans FE-900. Introduction. Testing Equipment. Testing Standards. Prior to Testing

COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE

COURSE NUMBER: ME 321 Fluid Mechanics I Fluid statics. Course teacher Dr. M. Mahbubur Razzaque Professor Department of Mechanical Engineering BUET

No E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD.

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

ISS0065 Control Instrumentation Lecture 12

Third measurement MEASUREMENT OF PRESSURE

Aerodynamic Analysis of a Symmetric Aerofoil

Gas Physics Pressure and Flow Topics Covered:

IT STARTS AT THE SOURCE - RE-CALIBRATING YOUR PLANT METERS

Fluid Machinery Introduction to the laboratory measurements

Measurement and simulation of the flow field around a triangular lattice meteorological mast

REFERENCE GUIDE. Rev. 0 15/09/2016

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources

Measurement Technology

CHARACTERISTICS OF LEAK DETECTION BASED ON DIFERENTIAL PRESSURE MEASUREMENT

Chapter 13 Fluids. Copyright 2009 Pearson Education, Inc.

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

H16 Losses in Piping Systems

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory

Lecture Outline Chapter 15. Physics, 4 th Edition James S. Walker. Copyright 2010 Pearson Education, Inc.

Experiment. THE RELATIONSHIP BETWEEN VOLUME AND TEMPERATURE, i.e.,charles Law. By Dale A. Hammond, PhD, Brigham Young University Hawaii

Tutorial. BOSfluids. Relief valve

CORESTA RECOMMENDED METHOD N 6

STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK /J.02/0006-A4

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility

A Performanced Based Angle of Attack Display

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Middle East Technical University Department of Mechanical Engineering ME 305 Fluid Mechanics I Fall 2018 Section 4 (Dr.

EDUCTOR. principle of operation

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

METHOD 2E - DETERMINATION OF LANDFILL GAS PRODUCTION FLOW RATE. NOTE: This method does not include all of the

GOOD PRACTICE GUIDE AN INTRODUCTION TO FLOW METER INSTALLATION EFFECTS

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007

CVEN 311 Fluid Dynamics Fall Semester 2011 Dr. Kelly Brumbelow, Texas A&M University. Final Exam

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:

Cover Page for Lab Report Group Portion. Lift on a Wing

SIZING AND CAPACITIES OF GAS PIPING Reserved

P06 & P012 Pitot-Static Probes

Lab. Manual. Fluid Mechanics. The Department of Civil and Architectural Engineering

CONTROL VALVE WHAT YOU NEED TO LEARN?

P8 to P60 Pitot-Static Probes

THE FUNDAMENTALS OF THE AIR SAMPLER CALIBRATION-VERIFICATION PROCESS

THE WAY THE VENTURI AND ORIFICES WORK

Novel empirical correlations for estimation of bubble point pressure, saturated viscosity and gas solubility of crude oils

SPH 4C Unit 4 Hydraulics and Pneumatic Systems

Hours / 100 Marks Seat No.

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF PRESSURE METROLOGY

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

Thermodynamic Study of Compartment Venting

Lab Problems. Lab Problems for Chapter Fluid Characterization by Use of a Stormer Viscometer L-1

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

FLUID DYNAMICS Ch.E-204 Umair Aslam Lecturer Department of Chemical Engineering

Characterizers for control loops

S-Type Pitot Tube. Operating Instructions

INTRODUCTION TO REGULATOR AND RELIEF VALVE SIZING. Introduction

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING

OXYGEN PRESSURE REGULATOR DESIGN AND ANALYSIS THROUGH FINITE ELEMENT MODELING

Chapter 15 Fluid. Density

SIZING AND CAPACITIES OF GAS PIPING

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

TI 176B Flow Rate Audit Calculations

PROCESS MONITORING AND CONTROL

Cover Page for Lab Report Group Portion. Pump Performance

BERNOULLI EFFECTS ON PRESSURE.ACTIVATED W ATER LEVEL GAUGES

AIAA Brush Seal Performance Evaluation. P. F. Crudgington Cross Manufacturing Co. Ltd. Devizes, ENGLAND

Type R622 Pressure Reducing Regulator

Validation of Custody Transfer Metering Skid at Site After Laboratory Proving

Transcription:

Volume, Issue 5, December 23 AN APPROACH TO DEVELOPMENT OF AIR LEAKAGE TEST RIG FOR AIR HANDLING UNITS HOUSING. Deepak Singh Asst. Professor, Department of Mechanical Engineering Kautilya Institute of Technology and Engineering, Sitapura, Jaipur Email: singhdeep_77@rediffmail.com ABSTARCT: Flow measurement plays vital role in Air conditioning leak detection to measure leakages of conditioned air in a airconditioning system of the building. It is costlier process to convert properties of air into making of desired atmosphere of the building. The leakage of conditioned air is cause of loss of money. In this stems the need for accurate, economical measurement for leakages is essential to control the quality and quantity of air properties. Orifice metering is the popular and economical procedure used in satisfies most flow measurement applications and is the most common flow meter in use now a day. In this paper an orifice meter test rig developed, tested and calibrated for measurement of leakages in Air handling units of air management system for a building. Results of testing orifice plate recorded with precise instruments to find out significance of using orifice plate for air flow leakage measurement from Air handling units housing. Keywords: Orifice; Inclined tube manometer; U-tube manometer; Air handling unit.. INTRODUCTION The orifice meter is a type of obstacle measurement, sometimes called the head loss flow meter, is chosen most frequently because of its long history of use in many applications, versatility, and low cost, as compared to other flow meter available. An orifice plate is a thin plate with a hole in the middle. It is usually placed in a pipe in which fluid flows. When the fluid reaches the orifice plate, the fluid is forced to converge to go through the small hole, the point of maximum convergence actually occurs shortly downstream of the physical orifice, at the so-called vena contracta point. As it does so, the velocity and the pressure changes. Beyond the vena contracta, the fluid expands and the velocity and pressure change once again. By measuring the difference in fluid pressure between the normal pipe section and at the vena contracta, the volumetric and mass flow rates can be obtained from Bernoulli's equation. The differential pressure is measured through pressure taps located on each side of the orifice plate. 2. FLOW RATE COMPUTATIONS: The fundamental flow equation is h= C' df Pf where: h = Flow rate at base conditions C' = Orifice flow coefficient df = Differential pressure Pf = Absolute static pressure The orifice flow coefficient is calculated using other constants that identify diameter of the pipe, orifice bore diameter, base pressure and temperature with variables that relate to the physical properties of the fluid such as temperature, specific gravity, density, viscosity, and compressibility. Any change in the diameter of the orifice bore fluid composition or temperature will change the coefficient, thus, changing the rate of flow.

Volume, Issue 5, December 23 3. METER TUBE LENGTHS The flow of fluid through elbows, tees, and valves will cause turbulence, which adversely effects the fluid measurement. For accurate flow measurement, the fluid should enter the orifice plate free from swirls and cross currents. In order to achieve the desired flow profile, adequate upstream and downstream straight pipe is required and / or flow conditioners such as straightening vanes. The use of flow conditioners (straightening vanes) will also reduce turbulence within the meter tube while allowing shorter lengths of straight pipe. Research continues on straightening vanes in regard to effect location and relationship to meter tube lengths. An idea is given for Minimum lengths of straight pipe preceding and following the orifice plates in the figure. Fig.: Arrangement of test rig. There are to be no pipe connections within the minimum amount of straight pipe with the exception of the pressure taps, temperature probes, and/or straightening vane attachments. There is considerable research being conducted regarding minimum lengths of meter tube pipe required. The meter tube shall be checked for compliance with standards and available sizes of pipes. 4 Test Set up The test rig fabricated with applying standard ISO 567 for orifice and arrangement made as shown in Fig.. Globe valves were used for flow control in two channels. Channel is high flow rate channel where channel 2 is for low flow rates. Diameter of channel is 2.3 and for channel 2 it is 62.7 mm and β values are.636 and.5 respectively. Since the calibration is carried out on the actual setup, small deviations are unlikely to affect the general performance. The Highest flow rate that could be obtained with the blower fan was found to be l/s through channel, which implies that the total system pressure drop is 25 mm of water column (WC) based on the performance characteristic of fan. 2

Volume, Issue 5, December 23 The pressure drop across the orifice plate at this flow rate was about 86 mm of WC. The pressure drop of the meter itself would be about 5 mm of WC. Thus it is implied that the pressure drop between discharge ends of the fan to the stream state pressure drop would be around 2 mm of WC. This could have been be contributed by the gradual expansion at the discharge of the fan, the vibration isolator, the dividing T and the flow regulating valve. For measurement of differential pressure of orifice plate inclined tune manometer used and for static pressure measurement in the duct U tube manometer of 3 mm scale used. The fluid in the inclined tube manometer has a specific gravity of about.8 but the scale has been marked in mm WC. However, it was found that at differential pressures above 6 mm of WC the inclined tube manometer was not confirming to the reading of the U-tube manometer. Hence a calibration of the inclined tube manometer obtained against the U-tube manometer. Calibration chart shown in curve below. Diff. Pr. (mm Water) U-tube 8 6 4 2 2 3 4 5 6 7 8 9 Diff. Pr. (mm water) inclined tube Curve : Calibration of the inclined tube manometer. The least squares fit of the data yields the following equation with a regression coefficient of 99.95%. p U tube =.97 p inclined tube +.37 () With the pressure units in mm water column. Table Pressure Velocity U-tube Inclined TSI Testo Solomat Average TSI TSI Vane Average Discharge Hotwire Pitot mm wc mm wc Pa mm wc Pa mm wc m/s m/s m/s m/s l/s Descending 86 836 86 837 86.5.67 94.3 76 76.5 9.6 9.88 87.22 66 62 66 9.2 9.35 9.2 9.24 8.52 57 53 57 8.5 8.55 8.3 8.45 74.57 45 4 45 7.6 7.65 7.5 7.58 66.92 35.5 32 35.5 6.75 6.85 6.7 6.77 59.7 25 24.3 25 5.75 5.7 5.8 5.75 5.74 5 5 4.33 4.4 4.45 4.39 38.77 8 7. 8 3.5 3.2 3.2 3.5 27.8 Ascending 5 5 4.47 4.47 4.5 4.5 39.8 25 25 5.7 5.8 5.6 5.68 5.8 35 35 6.75 6.75 6.7 6.73 59.35 45 45 7.5 7.45 7.4 7.44 65.63 55 55 8.45 8.2 8. 8.2 72.47 65 65 9.5 9. 8.9 9.4 79.75 75 75 9.65 9.55 9.3 9.48 83.6 85 85.25.2 9.9.9 389.2 5 5 2.63 3.4 2.6 2.79 24.62

Volume, Issue 5, December 23 5 TEST METHOD: The test performed in two stages () Decreasing and increasing flow rate for channel, (2) Same for channel 2. The free ends of the both channels were allowed to discharge into the ambient with no obstructions for a substantial length such that no back pressure present. Flow rate from minimum to maximum were obtained by using the valve alone in channel. In the case of channel 2 for low flow rates first the valve in this section alone was used. However, at high flow rates the disturbances were too large to obtain a steady flow. Hence the valve in channel was used as a bypass to stabilize the flow rate. Four different types of velocity probes were used to measure the velocity at the centre of the pipe section. A vane anemometer, Pitot tube. The dynamic pressure was transformed to velocity using a differential pressure transducer, Hotwire anemometer, Pitot tube along with the differential pressure input to TSI instrument. The pressure drop across the orifice plate was measured with an inclined tube manometer. The differential pressure across the orifice plates as measured by the manometer was also used to cross check the accuracy of the TSI differential pressure measurement. It was found that they are all commensurate with each other with in the specified precision of each instrument. Velocities are measured at the centre of the pipe. Since the Reynolds numbers of flow were above in both the channels for the range of flows proposed to be measured by the test rig (namely 8.5 l/s and above) and the diameters of both channels are small it is assumed that this represents the average velocity. However, near the wall it may not be true. Thus, the leakage rates measured by the test rig will be pessimistic. The range of calibration is about -28 l/s for channel and 28-8 l/s for channel 2. TABLE 2: Experiment data for Channel 2 Pressure Velocity U Tube Inclined TSI Testo Average TSI TSI TESTO TESTO mm wc Pa mm wc mm wc HOTWIRE Pitot Pitot vane Average Discharge m/s m/s m/s m/s m/s I/s Ascending 2.5 3.35.45.3.37 3.99 2.77 2.86 2.7 2.78 8. 2 2 3.4 3.5 3.2 3.37 9.85 3 3 4.2 4.37 4.3 4. 4.25 2.4 4 39 4.8 4.75 4.7 4.6 4.7 3.77 5 49 5.65 5.5 5.3 5.3 5.44 5.89 6 59 6 5.95 5.6 5.8 5.84 7.6 7 68 6.45 6. 6. 6.2 6.2 8.6 8 78 6.8 6.85 6.8 6.82 9.92 6 Test Data. 9 88 7.55 7 7. 6.9 7.4 2.86 98 7.65 7.6 7.5 7.55 22.6 Test data shown in the table and plot on flow vs pressure drop for channel. Table 2 and plot show the same for 67 8.8 8.8 8.2 8 7.8 8 23.38 channel 2. For these tables the inclined tube manometer used after appropriate correction using the equation. The 68 9. 9. 8.65 8.4 8.2 8.42 24.6 flow rate was fitted as a function of measured pressure drop across the orifice plate through a 6th order polynomial 337 36.3 36.3 9.2 8.95 8.6 8.6 8.84 25.83 of the form given below. 532 56.2 56.2 9.9 9.7 9. 9.57 27.96 Descending Q(l/s) = A6 p6 + A5 p5 + A4 p4 + A3 p3 + A2 p2 + A p + A (2) 44 p 46.8 is mm of water 9.5 column. 9.2 8.8 9.7 26.79 The coefficients are listed 27 in table 3 below. The 29.5 error distributions 9.5 for the two channels 8.9 are shown 8.7 in the 8.88 curves. 25.96 Here the error is defined as the [measured flow 2. rate calculated 8.45 flow rate from equation 8.3 2] / measured 8 flow 8.25 rate X 24. %..9 8.5 7.8 7.7 7.85 22.94 The overall uncertainty of the 93 leak rate measurement 94.8 is expected 7.65 to be less than about 7.6 5% which is contributed 7.63 by 22.28 uncertainties 9 in differential 94.5 9 pressure measurements 9 and the fact 7.4 that only velocity 7.3 at the 7.3 axis has been considered 7.33 for 2.43 all flow 83 calculations. 84.5 The data 83 generated during 83 calibration were 7.5 also used for 6.8 evaluating 6.7 the coefficient 6.5 of discharge 6.76 9.76 (Cd) 74 of each of the 74.5 flow channels. 74 They are depicted 74 in curves 6.7 shown. It may 6.35 be observed 6.2 that Cd 6. values are 6.34.64 8.52 and.7 63 for channels 65 and 63 2 respectively. These 63 values are commensurate 6.25 with 6.5 those expected. 6. 5.9 6.8 7.75 53 54 53 53 Table 5.7 3 5.35 5.5 5.3 5.46 5.96 45 45 45 45 5.3 5.25 5 5 5.4 5. 33 34 33 33 4.6 4.55 4.55 4.3 4.5 3.5 25 25 25 25 3.8 3.87 4. 3.9 3.92.46 5 5 5 5 3.9 2.98 2.8 2.96 8.64 5 5 5 5.67.58.55.6 4 4.68

Volume, Issue 5, December 23 Coefficient Channel Channel 2 A6-5.33 x - -2.54 x - A5 2.884 x -7.468 x -8 A4-5.92 x -5-3.365 x -6 A3 4.58 x -3 3.87 x -4 A2 -.749 -.225 A 4.484.798 A.2265.24 Regression Coefficient 99.89% 99.64% Root mean square.4% 2.2% For the testing two typical air handling housings were tested for leak. Very low flow calibration For flow lower than 8.5 l/s, the channel 2 can still be used, but the calibration equation (2) with coefficients in table 3 will yield large uncertainties. Hence, a separate calibration is provided for this range taking the data points at differential pressures below 3 mm of water column. The calibration equation is given below. Q(l/s) = -3.7 x -5 p4 + 3.24 x -3 p3 -.985 p2 +.458 p +.3 (3) In the above equation again p is mm of WC. The difference between measured and calculated values will be about.6 l/s in the range. Flow Rate (l/s) 9 8 7 6 5 4 3 2 2 4 6 8 U-tube differential pressure (mm water) Curve 2: Readings for Channel 5

Volume, Issue 5, December 23 3 25 Floe rate (l/s) 2 5 5 2 4 6 8 2 4 6 U-tube differntial Pressure (mm water) Curve 3: Readings for Channel 2 (Q act-q Eqn.2)/Qact (%) 4 3 2 - -2-3 -4 2 4 6 8 Flow rate (l/s) Curve 4: Error distribution for channel (Q act-q Eqn.2)/Qact (%) 3 - -3-5 2 Flow rate (l/s) Curve 5: Error Distribution for Channel 2 6

Volume, Issue 5, December 23 (Q act-q Eqn.2)/Qact (%).9.8.7.6.5.4.3.2. 2 3 4 5 6 7 8 Flow rate (l/s) Curve6: Coefficient of discharge distribution for channel (Q act-q Eqn.2)/Qact (%).8.6.4.2 5 2 25 3 35 4 Flow rate (l/s) Curve 7: Coefficient of discharge distribution for channel 2 Axis Title 4 2 8 6 4 2 29.8, 2 9.9 5. 5 2.5 5 5 2 25 3 35 Axis Title Curve8: Very low flow measurement channel 2 7

Volume, Issue 5, December 23 7.CONSIDERATIONS. If the leak rate is not known always use the channel and the U-tube manometer or the TSI differential pressure transducer for measuring the differential pressure across the orifice plate. If a TSI instrument is used, whose display is in Pa, multiply the displayed value with.2 to obtain the pressure differential in mm of WC. The constants in Table 3 are applicable only when differential pressure is in mm of water column. Ensure that there are no leaks between the upstream of the orifice plate and the connection to the air handling unit housing. If the leak rates are below 28 l/s change over to channel 2 because at or below this flow rate the differential pressure across the orifice plate in channel will be quite small. For leak rates above about 2 l/s (equivalent to a differential pressure across orifice plate of about 8 mm of water column) when channel 2 is being used, It is possible that the differential pressure might fluctuate causing difficulties in getting a precise measurement. When this happens, bypass some amount of flow through channel and open the flow regulation valve in channel 2 till the differential pressure stabilizes. For leakage rates below 8 l/s use equation (3) for converting the differential pressure across the orifice plate of channel 2 in flow rates. 8. CONCLUSION: This test rig is most economical in measurement of leakages in ducting and Air handling unit housings. The flow measuring setup can be used for detecting leaks in the air handling unit housings from about 8 l/s to l/s. It may also applicable for testing in compliance to National and International standard like DW32, EU886 etc. Depending on the class of manufacture of the unit and surface area, it will be possible to guess the magnitude of possible leak. Based on this value choose channel if likely leakage is > 28 l/s and channel 2 if < 28 l/s. Multiply l/s by 3.6 to obtain m3/hr. 9. REFERENCES [] Perry s Chemical Engineering Handbook. [2] A.K.Tayal Book Title Instrumentation And Mechanical Measurements, Galgotia Publication, Delhi,26. [3] Smith Metering, Inc, FUNDAMENTALS OF ORIFICE METERING, White paper, pp.-6. [4] J. Q. Zhang, Y. Yan, A self validating differential pressure flow sensor, IEEE Instrumentation and Measurement Technology conference, Budapest, May 2. [5] J. E. Lawley, Orifice meter calibration, 57th International School of Hydrocarbon Measurement, document ID: 6233, 982. [6] B. T. Arnberg and C. L. Britten, Calibration of orifice meter assembly, Colorado Engineering Experiment Station Inc, Document ID: DA2769, 97. [7] E. O. Doebelin, Measurement Systems - Application and Design. Tata McGraw Hill publishing company, 5th edition, 23. [8] White paper, Emerson Process Management, Daniel Measurement and Control, Inc. [9] B. G. Liptak, Instrument Engineers Handbook: Process Measurement and Analysis, 4th Edition, CRC Press, June 23. [] R. J. Plaza. Sink or Swim: The Effects of Temperature on Liquid Density and Buoyancy. California state science fair, 26. [] Density of Fluids-Changing Pressure and Temperature, The [2] Rosemount 35 datasheets, 26. [3] R. F. Coughlin and F. F. Driscoll, Operational amplifiers & linear integrated circuits, Prentice Hall, 998. [4] F. Roger, Practical methods of optimization, 2nd Edition, John Wiley & Sons, New York, ISBN 978--47-9547-8, 987. [5] J.-B. Li and Y.-K. Chung, A Novel Back propagation Neural Network Training Algorithm Designed by an Ant Colony Optimization, IEEE/PES Transmission and Distribution Conference & Exhibition: Asia and Pacific Dalian, China 25 [6] L. Bianchi, L. M. Gambardella, M. Dorigo, An ant colony optimization approach to the probabilistic travelling salesman problem. Proc. of PPSN-VII, International Conference on Parallel Problem Solving from Nature, Lecture Notes in Computer Science, Springer Verlag, Berlin, Germany, 22. [7] Santhosh K. V. and B. K. Roy, An Intelligent Flow Measurement Technique Using Orifice, International Journal of Applied Physics and Mathematics, Vol. 2, No. 3, May 22 8