MA PHIT- Food Certificate Program

Similar documents
Thermocouple Temperature Measuring Probes

Calibration Procedure

CHAPTER 6 MEASUREMENT OF INSPECTION PARAMETERS. Measurement Ports

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

WBEA Standard Operating Procedure

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

! Warning, refer to accompanying documents.

How to specify a product. Process Sensors and Mechanical Instruments

Chapter 14 Shell Egg - Equipment Table of Contents

DG100 Digital Depth Gauge and Timer. Training Module, Rev B

Temperature gauge Installation Guide

HVAC, Plant Room & Utility.

MARATHON SENSORS INC. TROUBLESHOOTING A CARBON PROBE

O3 3E 1 F Gas Sensor Module

MANUFACTURING Administration: Assembly Line Packaging Fleet Maintenance

Heavy Duty Dissolved Oxygen Meter

Three Lakes Association Hydrolab for Dummies. Table of Contents:

PyroCouple Series Operators Guide

Pool and Spa. Water Testing

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Chapter 11 Cleaning and Sanitizing

PURA. Pure Gas Dewpoint Transmitter. Users Guide

Best Practice for Calibrating LTH Conductivity Instruments

GMC-I Service GmbH Calibration Center

EC214 EC215 - EC215R Bench Conductivity Meters

TECHNICAL NOTE. October 23, Procedures for Verifying Temperature Calibration

EVM Series: Frequently Asked Questions

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

STARLOG. Capacitive Water Depth Probe

DISSOLVED OXYGEN SENSOR BT34i

Advanced Test Equipment Rentals ATEC (2832)

Installation and Maintenance Instruction Manual

Free Chlorine Sensor For additional information, please visit our website at

ph measuring system for hygienic process applications

NIOSH Flowback Study. William G. Burket, CFPS

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

QUALITY ASSURANCE HATCHERY

DTG - LCD Digital Temperature Gauge USER MANUAL

Working Safely with Hydrofluoric Acid

K V A L I F I K. Our accreditation number: NAH /2015. Valid to:

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

SURVEYING THE HAZARDOUS MATERIALS INCIDENT

the annulus between the second casing string and the surface casing [must be] open to the atmosphere in the manner described in subsection (2).

How Bright Is Your Glow Stick? Measure It!

We measure it. For gas and water installers. testo hpa. bar

TEMPERATURE GRADIENT PLATE MFFT 10 / MFFT 20 VF9700 / VF9600

Gas Absorption Draft Standard Operating Procedure

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Instruction Manual MicroChem 2 Chlorine Probes Series CL4000

General Accreditation Guidance. General Equipment - Calibration and Checks, General Equipment Table

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Institute For Thermal Processing Specialists

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

HI 2314 HI 2315 HI 23151

DeFelsko PosiTector CMM IS Probe

QUICK START GUIDE TO DRINKING WATER MONITORING

Introduction. Seafood HACCP Alliance Training Course 8-1

Technical Data Sheet MF010-O-LC

DVC CULN 153: Safety & Sanitation FINAL EXAM Study Guide

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

E x p l o r a t i o n o f B a k i n g a n d P a s t r y A r t s ( 9 )

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Bassett Medical Center Transfusion Services

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Dissolved Oxygen Guide

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Technical Procedure for General Laboratory Equipment

Vet-Temp Ear Thermometer Frequently Asked Questions

The primary purpose of laboratory fume hoods is to keep toxic or irritating vapors out of the general laboratory working area.

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Air Ball! Evaluation copy

2014 Programme of Training Courses in Measurement & Calibration

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Ultima. X Series Gas Monitor

OXYGEN MICROOPTODE - OPTO SERIES USER MANUAL

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

UsER manual for Watersens ph -REDOX

PCDY01 Dissolved Oxygen Meter

Powers Controls D Day-Night Thermostats

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Phosgene Sensor. Sensoric COCl2 3E 1

ECOM EN2-F PARTS LIST PART PART NUMBER DESCRIPTION

analytical bulk flow distance FLOW level pressure temperature industrial communication

Calculating Total Uncertainty of Temperature Calibration with a Dry Block. Calibration White Paper. Beamex.

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

HBLT-A1 LIQUID LEVEL SENSOR

SCOPE OF WORK, SAFETY METHOD STATEMENT & RISK ASSESSMENT

MODEL GT820 OXYGEN SENSOR

LDO II AQ 2/2014, Edition 1.5

SEMEM3-78 Testing and calibrating instrumentation and control equipment and circuits

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

SS32L Dissolved O 2 Probe

NEULOG OXYGEN LOGGER SENSOR GUIDE

USER S GUIDE DepthTrax 1H HawkEye Portable Depth Finder (DT1H)

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

Water Testing Technologies: Stepping Into the 21 st Century Ivars Jaunakais

Air Check Lite Toxic Gas Monitor

Transcription:

Proper inspection equipment and the knowledge of how to use and care for the equipment is necessary for an inspector to be able to identify food safety hazards which could lead to foodborne illness. Day 1, Session 4. Inspection Equipment 1

Official identification Necessary forms (MA FEIR), regulations, guides Professional Appearance Proper attire and shoes Lab coat or protective or identifying clothing Head cover Adequate temperature measuring devices Alcohol swabs Chemical test kits Flashlight Black light Measuring device for distances, time Light meter ph meter Water activity meter Camera Communications equipment Day 1, Session 4. Inspection Equipment 2

Bimetal bayonet (dial) Bimetal digital Thermistor Thermocouple Infrared Dataloggers Time-temperature indicators Maximum registering Thermometers come in many different styles and are made by many different manufacturers. Sanitize before you use it! Most common type of thermometer Measures temperature through a metal stem (about 2 inches from tip) Calibration nut just below the dial Day 1, Session 4. Inspection Equipment 3

Measures temperature through metal tip at the end Easy to read Temperature calibration is set at factory There are many types of digital thermometers Digital Measures temperature in thin foods High output and fast response at low cost Day 1, Session 4. Inspection Equipment 4

Measures temperature electrically through a sensor in the tip Temperature calibration can be adjusted manually Interchangeable temperature probes Monitors the temperature of thin products such as hamburgers Various probes for: Surface Insertion/immersion Ambient Measures surface temperatures of foods from a variety of distances This type of thermometer is intended only for measuring surface temperatures of food It should not be used to verify critical internal temperatures Day 1, Session 4. Inspection Equipment 5

Appearance changes if threshold is reached Single-use disposable thermometer Comes in several types (t-strips, tapes, adhesive patches) Used to record the maximum temperature reached in a product or place It will hold the maximum temperature to which it is exposed Devices which record temperature over time May be either analog, or digital type Many data loggers are used in connection with a computer Day 1, Session 4. Inspection Equipment 6

Before their first use At regular intervals If dropped If used to measure extreme temperatures Whenever accuracy is in question Whenever enforcement action is anticipated Insert thermometer probe into a cup of water and crushed ice Be sure dimple is completely immersed in the water Wait 3 minutes Thermometer should read 32 F. If the thermometer does not read 32 F, turn the adjustment nut on the back of the reading dial until the dial reads 32 F. Wait 3 more minutes to verify correct adjustment Type 1. Heat Sensitive Tape 2. Infrared Thermometer 3. Data Logger 4. Bi-metal stem 5. Max. Registering 6. Thermocouple Match to Item Thin meat patty High temp dishmachine Food with bone Delivery truck (cold) Walk-in cooler Container beef stew Day 1, Session 4. Inspection Equipment 7

Portable light meters are necessary to measure the level of illumination in food areas. The ph measurement checks the hydrogen ion concentration of the food. The ph instrument consists of a meter and a suitable electrode probe. Manufacturer s calibration instructions should be followed. The calibration procedure must take into consideration the expected ph range of the food. A 2-point calibration using standard buffers of 4.0 and 7.0 is most common. When measuring the ph of a food, the measurement must be representative of the whole. Day 1, Session 4. Inspection Equipment 8

Time, as as well as temperature and concentration, are significant in the evaluation of warewashing operations. Tape measures may also useful The hot water rinse pressure of mechanical warewashing machines is an important factor. To measure line pressure, it is prudent to request the establishment personnel connect the pressure gauge. A water activity meter may be used to determine the food s available water or aw Day 1, Session 4. Inspection Equipment 9

A bright flashlight and an ultraviolet light (black light) can be used to identify physical evidence of insect and rodent infestation. High temperature Chemical Types? Chlorine Iodine Quaternary ammonia Day 1, Session 4. Inspection Equipment 10

Day 1, Session 4. Inspection Equipment 11

Fully equipped kit for investigating foodborne illness and sampling suspect foods Equipment, or means to support the record keeping system that can collect, analyze, retain and report pertinent information Day 1, Session 4. Inspection Equipment 12