FOAM TANK (1/2) DATA SHEET

Similar documents
FOAM TANK (1/2) DATA SHEET

AIR FOAM CHAMBER DATA SHEET

Foam Chamber Model-FC

VERTICAL BLADDER TANK

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

HORIZONTAL BLADDER TANK

BLADDER TANK PROPORTIONING SYSTEM PRE-PIPED

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA Q= C. Table 1 - Specifications

Horizontal Bladder Tanks

TECHNICAL DATA CAUTION

Vertical Bladder Tanks

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Model MTB-ASME Horizontal Bladder Tanks

Bladder Tank Installation & System Design Information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

Model MTB-ASME Vertical Bladder Tanks

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

Model MTB-ASME Vertical Bladder Tanks

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA. Trimpac 257a. September 16, 2013

BALANCED PRESSURE PROPORTIONERS

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

Wet pipe low flow foam/water system

TECHNICAL DATA. Trimpac 256a. October 31, 2013

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q = C v P S

OBSOLETE. Wet pipe low flow manifold system

Vertical and Horizontal Bladder Tanks

TECHNICAL DATA. Q = C v P S

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Q = C v P S

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

TECHNICAL DATA. Deluge Valves 218a. November 30, 2007 DELUGE VALVE MODEL F-1 STRAIGHT THROUGH STYLE 2-1/2 (DN65) - 8 (DN200)

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TECHNICAL DATA OBSOLETE

Bermad Pressure Reducing. Model: 42T

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

TECHNICAL DATA OBSOLETE

Bermad Model:

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. Deluge Valves 211a. November 30, 2007 DELUGE VALVE MODEL E-1 ANGLE STYLE 3 (DN80), 4 (DN100) & 6 (DN150)

TECHNICAL DATA. Trimpac 247a_Euro. September 16, 2013

756 Safety Relief Valves

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

OPERATION AND MAINTENANCE MANUAL

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Foam Systems. Fire Protection Solutions

KFI Approved. High Pressure CO2 System Technical Datasheets

LINE PROPORTIONERS LP NPR260 Approvals: UL, ULC

a pilot sprinkler were to be closed after its initial operation, for example a remote manual control station).

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

Worldwide Contacts. General Description

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Foam Mixers & Proportioning Systems

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

InnovDos Foam proportioning system

InnoVfoam B.V. InnovDos Foam Proportioning System

TECHNICAL DATA CAUTION

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

INSTALLATION OPERATION MAINTENANCE

CASH VALVE TYPE KP BACK PRESSURE VALVES

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

V43 Pressure Actuated Water Regulating Valve

Anti-flood device Model B-1

Geotech 1.66 Auto-Reclaimer

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

ECS Protector Nitrogen Inerting Vent (PAV-WN)

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

TECHNICAL DATA NOTICE

Chlorinator. MODEL C-731 (Floor Mounted)

Pressure Regulating Valves. Models 44, 77 & 68 PS\ UL. Pressure Relief Valve. Dorot Fire Protection Division. Certification & compliance by design

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

MEDICAL EQUIPMENT CATALOG

Geotech 1.66 Auto-Reclaimer Installation and Operation

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

TECHNICAL DATA. Dry 132a. October 1, 2008

Transcription:

FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 0 PROJECT : QUANTITY : 0 LOCATION : SERVICE : FOAM SYSTEM 0 05 CODE & STANDARDS 06 MODEL NO. YS-FT- 07 APPROVALS UL LISTED FM APPROVED KFEIC KISCO OTHERS 08 CODE & STANDARDS NFPA BS KFPL OTHERS 09 OPERATING CONDITIONS 10 TEMPERATURE MIN. : ( ) OPER. : ( AMB ) DESIGN : ( ) 11 PRESSURE OPER. : ( ) kg/cm² DESIGN : ( ) kg/cm² HYDRO TEST : ( ) kg/cm² 1 FLUID HANDLED WATER AND / OR SEA WATER FOAM-WATER SOLUTION 1 INSTALLATION OUTDOOR AND / OR INDOOR 1 DESIGN FEATURES 15 TANK TYPE HORIZONTAL VERTICAL ATMOSPHERIC INTERNAL BLADDER 16 TANK CAPACITY * LITER ( * GALON ) 17 TANK SIZE * mm(l) x * mm(i.d) 18 INSULATION * 19 FOAM PROPORTIONING (1) PROPORTIONER PUMP PROPORTIONER LINE PROPORTIONER 0 PRESSURE PROPORTIONER PRESSURE SIDE PROPORTIONER 1 () SIZE 1" 1-1/" " -1/" " " 6" 8" ANSI KS R.F F.F 150LBS 00LBS 10K 0K 5 () PROPORTIONING 1% % 6% % x 6% 6 RATE AFFF FFFP ATC AFFF / ATC 7 () ACCESSORIES BLANCED DIAPHRAGM CONTROL VALVE 8 FOAM LIQUID PUMP 9 : GENERAL WEATHER PROOF EXPLOSION PROOF 0 CONTROL VALVE 1 : PNEUMATIC MOTER OPERATED MANUAL : GENERAL WEATHER PROOF EXPLOSION PROOF : BALL BYTTERFLY GATE FOAM FLUSH-IN & FLUSH OUT CONNECTOR 5 FOAM SKID CONTROL PANEL 6 : GENERAL WEATHER PROOF EXPLOSION PROOF 7 PRESSURE RELIEF VALVE 8 PIPING, PRESSURE GAUGE 9 FILLING, DRAIN & OTHER VALVES, ETC. 0 MATERIALS 1 SHELL & BODY CARBON STEEL STAINLESS STEEL LUG & SUPPORT CARBON STEEL STAINLESS STEEL REV DATE PRP'D CHK'D APP'D DESCRIPTION 5 0 006-11-5 J. K. JEONG Y. K. AN S. M. LEE FOR STANDARDIZATION 6 7 8 9 1

FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (/) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 MATERIALS 0 PUMP CASING CAST IRON CAST STEEL STAINLESS STEEL 0 BALANCED DIAPHRAGM CONTROL VALVE BRASS BRASS STAINLESS STEEL 0 CONTROL VALE CAST IRON CAST STEEL STAINLESS STEEL 05 FOAM SKID CONTROL PNAEL CARBON STEEL STAINLESS STEEL 06 PRESSURE RELIEF VALVE BRASS BRASS STAINLESS STEEL 07 FOAM SUCTION & DISCHARGE PIPE, FITTING, VALVE CARBON STEEL STAINLESS STEEL 08 WATER LINE & FOAM SOLUTION DISCHARGE LINE CARBON STEEL STAINLESS STEEL 09 ACCESSORIES 10 LEVEL GAUGE VENT VALVE FILLING CAP DRAIN VALVE WATER INLET PIPING 11 FOAM OUTLET PIPING VALVE BREATHER VALVE ANCHOR BOLT, NUT & WASHER 1 NAME PLATE ACCESS LADDER EXPLANATION BOARD FOR OPERATING PROCEDURE 1 TEST & INSPECTION 1 DIMENSION INSPECTION WITNESS REVIEW MATERIAL INSPECTION WITNESS REVIEW 15 VISUAL INSPECTION WITNESS REVIEW PERFORMANCE TEST YES NO 16 FINISH UNIT WEIGHT 17 PAINTING * ( * ) Kg 18 COLOR * 19 0 1 5 6 7 8 9 0 1 5 6 7 8 9 0 1 REV DATE PRP'D CHK'D APP'D DESCRIPTION 5 0 006-11-5 J. K. JEONG Y. K. AN S. M. LEE FOR STANDARDIZATION 6 7 8 9 1

INLINE BALANCE PRESSURE FOAM PROPORTIONER TECHNICAL DATA : MODEL SIZE IB for Bronze construction IS 18 / ASTM B6 IBS for stainless steel ( 0 ) construction ( ASTM A51-CF8 ) 80, 100, 150 & 00 NB MAXIMUM SERVICE 1 BAR ( 00 PSI ) PRESSURE MIMIMUM WORKING.0 BAR. ( PSI ) PRESSURE FLOW RANGE Size Flow 80NB : 70-000LPM 100NB : 650-5700LPM 150NB : 100-9500LPM 00NB : 00-18500LPM FLANGE CONNECTION ANSI B16. Class 150# for bronze ANSI B16.5 Class 150# for stainless steel THREADED OPENING PRESSURE SENSING HOSE TRIM CONNECTION AND VARIOUS CONTROL VALVES FACTORY HYDROSTATIC TEST PRESSURE FINISH BSPT/NPT optional TEFLON tube with stainless steel braided cover Brass/stainless steel 5 Bar. ( 65 PSI) Epoxy Red Painted ORDERING Please specify : INFORMATION a) Model Number b) Flow rate c) Percentage of foam Concentrate used d) Type of Foam Concentrate used e) Flange Connection specification APPLICATION The inline balance pressure foam proportioners are used with positive displacement foam concentrate supply pump. The system controls accurately the flow of foam concentrate into the water stream over a wide range of flow rate and pressure. The Inline Balance Pressure Foam Proportioning System is used for simultaneous operation of the multiple foam injection even with different pressures between the two injection point with a single concentrate supply line. Various sizes of inline balance pressure proportioner can be combined to suit the flow requirement of each hazard area. SPECIFICATION Inline balance pressure proportioning system utilizes a single, positive displacement foam concentrate supply pump, an atmospheric foam concentrate storage tank, inline balance proportioner, and a foam concentrate regulating valve. The pressure regulating valve is mounted on foam concentrate return line to the foam concentrate storage tank. The valve regulates the foam concentrate supply pressure. The Inline balance pressure proportioner consists of a ratio controller, diaphragm operated pressure balancing valve, water and foam gauges, and pressure sensing hose of teflon tube with stainless steel braided cover, interconnecting trim fittings with various control and flush valves. The water inlet pressure and foam concentrate pressure at metering orifice is sensed by a diaphragm valve and it automatically balances the concentrate supply to provide accurately proportioned water foam solution over a wide range of flow conditions. A foam concentrate supply valve is also provided as an optional item. The system requires foam concentrate supply pressure of 1.5-.0 bar. higher than the water supply pressure. The Inline balance pressure proportioner is also provided with a manual balancing valve. JANUARY, 006 PAGE 1 OF

INSPECTION AND MAINTENANCE A qualified and trained person must commission the system. After a few initial successful tests, an authorized person must be trained to perform the inspection and testing of the system. It is recommended to carry out physical inspection of the system at least once in a week. The inspection should verify that all the valves are in their proper position as per the system requirement and no damage has taken place to any component. The system where foam concentrate piping is maintained in charged condition, the provision should be made to flow foam through each Inline Balance Proportioner at least once in six weeks. The system should be fully tested at least once in a year or in accordance with applicable NFPA codes, or in accordance to the guidelines of the organization having local jurisdiction. INLINE BALANCE PRESSURE PROPORTIONER WITH MANUAL OVERRIDE DIAPHRAGM BALANCE VALVE MANUAL OVERRIDE VALVE WATER GAUGE FOAM GAUGE FOAM SENSING LINE FOAM CONSENTRATE SUPPLY VALVE DIMENSIONS SIZE A B C D 80 NB 191 60 67 90 100 NB 6 608 78 51 150 NB 0 700 5 605 00 NB 0 718 6 65 FOAM CONSENTRATE INLET CONNECTION C FLUSH OUT VALVE DRAIN PLUG WATER SENSING LINE WATER INLET RATIO CONTROLLER B A D FOAM SOLUTION OUTLET Dimensions in millimetre (Approximate) INLINE BALANCE PRESSURE PROPORTIONER WITHOUT MANUAL OVERRIDE WATER GAUGE FOAM GAUGE DIAPHRAGM BALANCE VALVE FOAM SENSING LINE FOAM CONSENTRATE SUPPLY VALVE DIMENSIONS SIZE A B C D 80 NB 191 55 85 7 100 NB 6 50 05 5 150 NB 0 590 60 50 00 NB 0 586 96 581 FOAM CONSENTRATE INLET CONNECTION C FLUSH OUT VALVE DRAIN PLUG WATER SENSING LINE WATER INLET RATIO CONTROLLER D FOAM SOLUTION OUTLET Dimensions in millimetre (Approximate) B A JANUARY, 006 PAGE OF

FLOW VS PRESSURE LOSS 1.0 0.8 FRICTION LOSS, KG. / SQ. CM. 0.6 0. 0. 0.1 80 NB 100 NB 150 NB 00 NB 0.05 0.5 1 6 8 1 16 0 SOLUTION FLOW, LPM ( AXIS READING X 1000) PRESSURE VS FLOW GRAPH INLET PRESSURE, KG./SQ.CM. 1 1 11 10 9 8 7 6 5 5 6 7 8 9 10 11 1 1 1 15 16 17 18 19 SOLUTION FLOW, LPM ( AXIS READING X 1000 ) SIZE 00NB INLET PRESSURE, KG./SQ.CM. 1 1 11 10 9 8 7 6 5 0 10 0 0 0 50 60 70 80 90 100 SOLUTION FLOW, LPM ( AXIS READING X 100 ) SIZE 150NB 1 1 INLET PRESSURE, KG./SQ.CM. 11 10 9 8 7 6 5 0 10 0 0 SOLUTION FLOW, LPM ( AXIS READING X 100 ) SIZE 80NB JANUARY, 006 PAGE OF

TYPICAL INLINE BALANCE PRESSURE FOAM PROPORTIONING SYSTEM CAUTION Do not turn off the system or any valve to repair or test the system, without placing a roving Fire Patrol in the area covered by the system. The Patrol should continue until the system is put back in service. Also inform the local security guards and the control alarm station, so as to avoid false alarm.. JANUARY, 006 PAGE OF