Gas Viscosity Measurement and Evaluation for High Pressure and High Temperature Gas Reservoirs

Similar documents
International Journal of Petroleum and Geoscience Engineering Volume 03, Issue 01, Pages 56-60, 2015

Novel empirical correlations for estimation of bubble point pressure, saturated viscosity and gas solubility of crude oils

New Viscosity Correlation for Different Iraqi Oil Fields

Gas viscosity ( ) Carr-Kobayashi-Burrows Correlation Method Lee-Gonzalez-Eakin Method. Carr-Kobayashi-Burrows Correlation Method

Validation Study of Gas Solubility Correlations at bubble point pressure for Some Libyan Crude Oils Using Three chosen Correlations

Abstract Introduction

EXPERIMENTAL INVESTIGATION ON HIGH-PRESSURE, HIGH- TEMPERATURE VISCOSITY OF GAS MIXTURES. A Dissertation EHSAN DAVANI

Natural Gas Properties Analysis of Bangladesh: A Case Study of Titas Gas Field

Evaluation of Three Different Bubble Point Pressure Correlations on Some Libyan Crude Oils

Measurement of the Best Z-Factor Correlation Using Gas Well Inflow Performance Data in Niger-Delta

THREE-PHASE UNSTEADY-STATE RELATIVE PERMEABILITY MEASUREMENTS IN CONSOLIDATED CORES USING THREE IMMISCIBLE LIQUIDS

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

Experimental Determination of Water Content of Sweet Natural Gas with Methane Component Below 70%

Fit for Purpose Compositional Input for Allocation Using Equations of State Thomas Hurstell, Letton Hall Group

Example: Calculate the density of methane at 50 psig and 32 ⁰F. H.W. In previous example calculate the density of methane in gm/m 3.

SPE Copyright 2001, Society of Petroleum Engineers Inc.

LEAP CO 2 Laboratory CO 2 mixtures test facility

Optimization of Separator Train in Oil Industry

International Journal of Petroleum and Geoscience Engineering Volume 03, Issue 02, Pages , 2015

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

INVESTIGATION OF THE EFFECT OF STIMULATION TREATMENT AND CERTAIN PARAMETERS ON GAS WELL DELIVERABILIITY BY USING DIFFERENT ANALYSIS APPROACHES

Accurate Measurement of Steam Flow Properties

Applied Technology and Best Practices in CEE. Conference

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Micro Motion Pressure Drop Testing

PMI Pulse Decay Permeameter for Shale Rock Characterization Yang Yu, Scientist Porous Materials Inc., 20 Dutch Mill Road, Ithaca NY 14850

44 (0) E:

A VALID APPROACH TO CORRECT CAPILLARY PRESSURE CURVES- A CASE STUDY OF BEREA AND TIGHT GAS SANDS

Determination of Bubble-Point and Dew-Point Pressure Without a Visual Cell

THE SOLUBILITY OF HYDROCARBONS IN AMINE SOLUTIONS Supplemental Material

The University of Hong Kong Department of Physics Experimental Physics Laboratory

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

COPYRIGHT. Reservoir Fluid Core. Single Phase, Single Component Systems. By the end of this lesson, you will be able to:

stat0il Tone Orke Reservoir Fluid Study for Statoil, Well by Arne M.Martinsen LAB Den norske stab ol.ieselskap a.

PVT analysis of. bottom hole sample from Well by Otto Rogne. STAT01 L EXPLORATION 81 PRODUCTlON LABORATORY

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

International Journal of Advance Engineering and Research Development DESIGN CALCULATIONS TO EVALUATE PERFORMANCE PARAMETERS OF COMPRESSOR VALVE

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Sarah N. S. All-Said Noor * ; Dr. Mohammed S. Al-Jawad ** ; Dr. Abdul Aali Al- Dabaj ***

Flow Vision I MX Gas Blending Station

Description of saturation curves and boiling process of dry air

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory

WATER OIL RELATIVE PERMEABILITY COMPARATIVE STUDY: STEADY VERSUS UNSTEADY STATE

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Drilling Efficiency Utilizing Coriolis Flow Technology

Limitations of ASME PTC 10 in Accurately Evaluating Centrifugal Compressor Thermodynamic Performance ABSTRACT

PVT Analysis Reports of Akpet GT9 and GT12 Reservoirs

Modeling Diffusion Rates of a Gas in an Enclosed Space

An approach to account ESP head degradation in gassy well for ESP frequency optimization

A COMPARATIVE STUDY OF PARAFFIN WAX

Steve David David & Associates, LLC David & Associates, LLC

APPLICATION NOTE. GC Integrated Permeation Device

Lab 1. Adiabatic and reversible compression of a gas

CHAPTER 6: PERMEABILITY MEASUREMENT

The Use of a Process Simulator to Model Aeration Control Valve Position and System Pressure

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

Chapter 22 Testing Protocols

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

CHEM 355 EXPERIMENT 7. Viscosity of gases: Estimation of molecular diameter

Characteristics of Decompression Tank Internally Pressurized With Water Using OpenFOAM Syamsuri 1, a

Thermodynamics ERT 206 Properties of Pure Substance HANNA ILYANI ZULHAIMI

EXPERIMENTAL STUDY ON BEESWAX USING WATERJET DRILLING

Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

Name Chemistry Pre-AP

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Control Valve Sizing. Sizing & Selection 3 P 1. P 2 (Outlet Pressure) P V P VC. CONTENTS Introduction Nomenclature Calculating C v

Improve Process Reliability

29 Pressure, Temperature relationship of a gas

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

An Investigation of Liquid Injection in Refrigeration Screw Compressors

Interchangeability Criteria.

Section 2 Multiphase Flow, Flowing Well Performance

The Gas Laws: Boyle's Law and Charles Law

Multiple Tube - Teflon PTFE-Glass Flowmeters

CHM Basics of Gases (r14) Charles Taylor 1/9

ISO INTERNATIONAL STANDARD

The Split of Two-Phase-Flow at Horizontal Side-T-junctions in Unbalanced Pipe Systems for Clean Extinguishing Agents

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

Perforating Center of Excellence TESTING SERVICES OVERVIEW

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Determining the Oxygen Transmission Rate of Carton Packages

Analysis of Shear Lag in Steel Angle Connectors

Air entrainment in Dip coating under vacuum

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

CHEM 3351 Physical Chemistry I, Fall 2017

Chapter 13 Temperature, Kinetic Theory, and the Gas Laws 497

Testing Services Overview

Engineering Information. Flow Data. Flow Data. Importance of Valve Sizing. Estimating Cv or Orifice Size:

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Drilling fluid rheology at challenging drilling conditions an experimental study using a 1000 bar pressure cell

Transcription:

International Journal of Science and Engineering Investigations vol. 5, issue 54, July 2016 ISSN: 2251-8843 Gas Viscosity Measurement and Evaluation for High Pressure and High Temperature Gas Reservoirs Ijeoma Azubuike 1, Sunday Ikiensikimama 2, Oyinkepreye Orodu 3 1 World Bank African Center of Excellence for Oil Field Chemicals Research, Institute of Petroleum Studies, University of Port- Harcourt, Nigeria 2 University of Port-Harcourt, Nigeria 3 Covenant University, Ota, Nigeria ( 1 ireneada@yahoo.com, 2 ikien2003@yahoo.com, 3 preye.d.orodu@gmail.com) Abstract- Gas viscosity is an important fluid property in oil and gas engineering due to its impact on hydrocarbon production and transportation, reservoir recovery, fluid flow, deliverability, and well storage. Existing gas viscosity correlations were derived using measured data at low to moderate pressure and temperatures. No measured gas viscosities at high pressure high temperature (HPHT) using reservoir sample are currently available, and using the extrapolation approach is not reliable. Therefore, this research paper presents laboratory measurement of gas viscosity at HPHT and comparative study of some existing gas viscosity correlations using the measured data. The capillary electromagnetic viscometer was used to measure gas viscosity for pressures between 6,000 psia and 14,000 psia; and temperatures of 270 o F and 370 o F. The comparative study shows that the gas viscosity models commonly used in the industry are not very reliable at HPHT conditions. and Abu performed better than other evaluated correlations with the mean relative error of -5.22 and absolute error of 8.752 for the temperature of 270 o F while came out the best for the temperature of 370 o F with mean relative error of -16.88 and 16.88 for absolute mean error. Cross plots showed the poor performance of the evaluated correlations using the measured data at HPHT conditions. From the analysis, the oil and gas industry needs new gas viscosity correlations that can predict gas viscosity at HPHT region. Keywords- gas viscosity, evaluation, pressure, temperature I. INTRODUCTION The knowledge of the viscosity of hydrocarbon fluids is needed to study the dynamics or flow behavior of these mixtures through pipes, porous media, or more generally wherever transport of momentum occurs in fluid motion. The calculation of reserves in a gas reservoir or the determination of its performance at various stages requires the knowledge of the fluid s physical properties at elevated pressure and temperature. The principal among these properties is gas viscosity. Viscosity is a measure of a fluid s internal resistance to flow. It is expected to increase with both pressure and temperature, is usually several orders of magnitude smaller than that of oil or water; and therefore, gas is much more mobile in the reservoir than either oil or water. The most accurate way to quantify natural gas viscosity is to measure them in laboratory but accurate measurement is extremely difficult and expensive [1]. Because of the difficulties of viscosity measurements in laboratory, this parameter can be estimated from empirical correlations with low deviation. Natural gas viscosity has been studied thoroughly by many authors ( [2]; [3]; [4]; [5]; [6]; [7]; [8]; [9]; [1]; [10] ) at low to moderate pressures and temperatures, yet there is still lack of detailed knowledge of gas viscosity at high pressures and high temperature (HPHT) in the petroleum industry. [2] graphical correlations has been the most popular charts in the petroleum industry, because their chart set is perhaps the most complete, including the atmospheric pressure chart, the viscosity ratio charts and correcting charts for nonhydrocarbons. They used experimental technique of [11] to create the correlation, as a function of pseudo-reduced pressure, pseudo-reduced temperature and viscosity ratio. It was reported to have an average of 0.38 absolute errors. [2] Correlation is recommended to be used for gases with specific gravity between 0.55 and 1.22 and a temperature range between 100 and 300 o F. [5] Regressed [2] data and obtained a mathematical expression which hold for the whole range of [2] chart. [6] In 1966 presented a semi empirical relationship for calculating the viscosity of natural gases. The authors expressed the gas viscosity in terms of the reservoir temperature, gas density, and the molecular weight of the gas. The proposed correlation can predict viscosity value with a standard deviation of 2.7% and a maximum deviation of 8.99%. The correlation is less accurate for gases with higher specific gravities. The authors pointed out that the method cannot be used for sour gases. Their correlation was developed for pressure ranges between 100 and 8000 psi and temperature ranges between 100 and 340 o F. [4] Developed a correlation for the viscosity of pure components such as argon, nitrogen, oxygen, carbon dioxide, sulphur dioxide, methane ethane, propane, butane and pentane. 157

They reported approximately 4% average absolute error and also stated that the correlation should only be applied for values of reduced density below 2.0. [12] Proposed a convenient mathematical expression for calculating the viscosity of the natural gas at atmospheric pressure and reservoir temperature, µ 1. Also, he formulated the viscosity correction at one atmosphere for the content of H 2 S, CO 2 and N 2. So by combining [12] and [5] correlation, the viscosity can be calculated. [7] Developed a new correlation for hydrocarbon gas viscosity as a function of the gas viscosity at 1 atmosphere, gas density and temperature. He reported a 4.91% average absolute error for natural gas viscosity at pressure based on the database evaluated. [13] Used a Cambridge viscosity SPL440 system to measure the viscosity of pure methane at pressures from 5,000 to 30,000 psi and temperatures from 100 to 400 o F. Based on the results from the measurements, [13] modified the correlation by [6]. The author then compared the modified [6] correlation to [14] values for pure gas. The results showed a very good match with the [14] values compared to the performance of the original correlation by [6]. However, Viswanathan s findings cannot be directly extrapolated to situations where impurities are present in the gas [8] Developed a relationship for calculating the viscosity of natural gas under surface and reservoir condition. They obtained the correlation by the analysis of experimental pressure, volume and Temperature (PVT) data of Gas associated with Nigerian Crude oil. The authors went further to compare equation formulated with experimental PVT viscosity and then tested the general validity of the new equation by using it to solve two problems for which solutions by the complex charts of [2] were available. [1] Showed in their work that small errors in gas viscosity affect the inflow performance relationship (IPR) curves and eventually change the reserves estimate for HPHT conditions in ways that drastically influence production forecasting. The authors also reported that through the work they did that none of the gas viscosity is reliable at HPHT condition. [9] Presented a paper on the review of gas viscosity correlations that are available in the open literature, and discusses the validity of published gas viscosity correlations based on the range of applicability. The authors selected the falling body viscometer to measure gas viscosity for the pressure range of 3,000 to 24,500 psi and temperature range of 100 to 415 o F. Nitrogen was used to calibrate the instrument and to account for the fact that the concentrations of nonhydrocarbons are observed to increase dramatically in HPHT reservoirs. Viscosity is measured to reflect the fact that, at HPHT conditions, the reservoir fluids will be very lean gases, typically methane with some degree of impurity. The experiments showed that [6] correlation accurately estimates gas viscosity at low to moderate pressure and temperature, but does not provide a good match to gas viscosity at HPHT conditions. [10] Presented work on the evaluation of gas viscosity correlations for the Niger Delta gas reservoirs. They evaluated their correlations based on the statistical analysis of percentage mean relative error, percentage absolute error, standard deviation of the mean relative error, absolute error and the coefficient of correlation. 319 data sets obtained from Niger Delta gas reservoirs were used for the analysis. From the statistical analysis result, the authors reported that [5] correlation ranked the best with the numerical value of 0.705 and also with the best performance plot. Charts of Viscosity against Pseudo Reduced Pressure and Temperature as well as Viscosity Ratio versus Pseudo Reduced Pressure and Temperature were also developed based on [5] correlation for Niger Delta region. They stated that their work is valid for data range of 1.4 T r 1.90 and 0.2 P r 10.80. Having gone through the literature review, it can be observed that the data range used in the development and evaluation of gas viscosity are mainly based on low to moderate data base but very little are done for extreme conditions.. The need to understand and be able to predict gas viscosity at HPHT has become increasingly important as exploration moved to deeper formations where HPHT conditions are more likely to exist. High pressure and High Temperature (HPHT) gas reservoirs are defined as reservoirs having pressure greater than 10,000 psia and temperature over 300 o F [1]. Therefore, this paper presents the measurement of gas viscosity at HPHT and the evaluation of the existing correlations for these extreme conditions. II. MEASUREMENT OF GAS VISCOSITY The Cambridge Electromagnetic Viscometer was used for the measurement of gas viscosity. Electromagnetic Viscometer (EMV) System is based on the Cambridge Viscosity SPL440 sensor and the VP2000 viscometer controller. The SPL440 sensor is installed in a dedicated oven, permitting operation from just below ambient to its maximum operating temperature of 374 F. The cylindrical viscosity sensor is mounted in a cradle that allows it to be orientated in four fixed positions for loading, operating, and torque opening/closure of the removable end of the sensor. The oven for this EMV system has been enlarged to accommodate a Degasser Fitting on the top of the EMV cell in place of the standard adapter. A system of three valves mounted inside the oven, but operated externally; allow the sample to be charged to the sensor. An inline filter in the oven on the inlet side of the system removes particulates which could interfere with the measurements. A pressure transmitter, mounted just outside the oven, monitors the pressure. The pressure transmitter is mounted above an external bleed/purge valve which allows the dead-space up to the transmitter body to be cleaned between analyses to minimize risk of sample carry-over. The pressure rating of the system is dependent on the weakest link of the installed components. Three (3) pressure ranges are available, 10,000, 15,000, or 20,000 psi. The SPL440 sensor is rated to 20,000 psig. The oven is mounted on the top of a modular, roll around aluminum framework which also supports the VP2000 control box and International Journal of Science and Engineering Investigations, Volume 5, Issue 54, July 2016 158

Viscosity (cp) Viscosity (cp) the CLI built Control Box. The VP2000 control box controls the piston movement inside the SPL440 as well as monitoring the internal SPL440 sensor. It holds the calibration data for all the supplied sinkers and uses these data to produce a raw viscosity figure. The raw viscosity figure is subject to correction for pressure and temperature distortion effects on the piston and measurement tube. The RS232 connection inside the VP2000 box is connected through to the front panel of the CLI EMV Control Box to allow logging or setup operations to be performed. This system also has an RS232 connector on the front panel to allow communication with the pressure display. A LabVIEW TM pressure logger application is provided on the DVD in the documentation folder. A representative of natural gas reservoir fluid samples were collected from the extreme high pressure gas reservoirs located in Niger Delta of Nigeria. The gas viscosity was measured using electromagnetic viscometer for the reservoir bottom hole samples pressures of 6000psia to 14,000psia and temperature of 270 o F and 370 o F. After measuring the viscosity at 370 o F, the samples were cooled to 270 o F and the experiment was repeated at that lower temperature for the various pressure ranges studied. Table 1 shows the composition of the samples used. TABLE I. COMPOSITION OF THE GAS MIXTURES Composition Sample 1 Sample 2 C 1 9 90.44 C 2 4.07 4.06 C 3 1.29 1.29 i-c 4 0.29 0.29 n-c 4 0.31 0.41 i-c 5 0.51 0.09 n-c 6 0.10 0.08 C 7+ 0.25 0.14 N 2 0.13 0.14 CO 2 3.21 3.00 III. RESULTS AND DISCUSSION A. Effect of Pressure and Temperature on Gas Viscosity The effects of both high temperature and pressure on gas viscosity for the samples are shown in Figs. 1 and 2. It was also observed that the impacts of temperature on gas viscosity in the high pressure and at temperatures of 270 o F are much higher than those at 370 o F. The result indicates that as temperature increases the gas viscosity decreases. 4 2 8 6 4 2 Figure 1. gas viscosity for gas sample- 1 at 270 o F and 370 o F 8 6 4 2 8 6 4 2 0 Lab. Data 1, @270oF Lab. Data 1, @370 of Lab. Data 2, @270oF Lab. Data 2, @370oF Figure 2. gas viscosity for gas sample- 2 at 270 o F and 370 o F B. Analysis of Existing Correlations with Data The laboratory measured gas viscosity data at HPHT were assessed to ascertain the accuracy of some selected correlations as applied to natural gas. The correlations evaluated are: [6]; [5]; [8]; [3] and [13]. These correlations were carefully selected, having been developed specifically for the prediction of natural gas viscosity. [2] Correlation was used to correct for the presence of impurities. Accuracy of Empirical Models: Gas Samples at 270 o F and 370 o F The accuracy of ([6]; [5]; [8]; [3], [13]) empirical correlations was assessed for estimating gas viscosity for gas Sample 1. Fig. 3 compares the selected gas viscosity models with the measured data at 270 o F for the entire pressure range studied; similarly Fig. 4 shows models comparison at 370 o F. [3] And [13] were also among the correlation studied but their error margins are very high therefore, their plots were dropped from the figures. It can be observed from the charts that almost all the correlations studied overestimated the measured gas viscosity over the entire pressure range evaluated in this study with [8] coming closer to the measured data at very high pressure (Fig. 3). International Journal of Science and Engineering Investigations, Volume 5, Issue 54, July 2016 159

Viscosity (cp) Viscosity (cp) Viscosity (cp) Viscosity(cp) 5 5 5 5 5 Data 1 @ 270oF Figure 3. Gas Viscosity against Pressure at 270 o F for gas Sample- 1 5 Data 2 @ 270oF Figure 5. Gas Viscosity against Pressure at 270 o F for Sample- 2 5 5 5 0.015 Data 1 @ 370 of 5 5 5 Data 2 @ 370oF 0.01 Figure 4. Gas Viscosity against Pressure at 370 o F for Sample- 1 Pressure(psia) Figure 6. Gas Viscosity against Pressure at 370 o F for Sample -2 Figs. 5 and 6 compares gas viscosity calculated using some of the correlations with the measured data for the second sample at 270 o F and 370 o F. The same data trend was also observed as shown in Figs. 3 and 4. The difference between the computed and measured gas viscosity are greater, especially in the high-pressure range. C. Statistical Comparison The results of the assessment as presented in Figs. 7 and 8 are the plots of mean relative and absolute error showing the natural gas viscosity measured at 270 o F and 370 o F. Comparing Figs. 7 and 8, it can be found that the total mean error for the 370 o F cases and for [8] and [5] are more than two times greater than those for 270 o F, expect for [6] which generally performed badly for the data set studied. These differences suggest neither these correlations has been matched or turned to data at higher temperatures and seem to validate our concerns about extending the [2] correlation numerically to higher pressures and temperatures. International Journal of Science and Engineering Investigations, Volume 5, Issue 54, July 2016 160

Predicted (cp) Predicted (cp) Predicted (cp) MAE & MRE @ 270 o F 5 %MAE %MRE 5 al, 1966-60 -40-20 0 20 40 60 5 (cp) Figure 7. Mean Relative and Absolute Error at 270 o F Figure 9. Cross Plot of predicted against Viscosity for [5] MAE & MRE @ 370 o F and Abu 5 %MAE %MRE 5 al, 1966-40 -20 0 20 40 5 5 (cp) Figure 10. Cross Plot of predicted against Viscosity for [8] Figure 8. Mean Relative and Absolute Error at 370 o F D. Cross Plots: Graphical Analysis Cross plots are plots of experimental values of natural gas viscosity against those estimated by the correlations. A perfect correlation is that plot that gives a straight line with a slope of 45 o. Among all the correlations studied (Figs. 9 to 11), none of them gives a perfect slope of 45 o. From the cross plots analysis, [8] performed better than others which also agreed with the previous evaluation. 5 5 al (1966) 5 (cp) Figure 11. Cross Plot of predicted against Viscosity for [6] International Journal of Science and Engineering Investigations, Volume 5, Issue 54, July 2016 161

IV. CONCLUSION The laboratory experiments for measuring gas viscosity and evaluation of some existing gas correlations has been presented. Gas viscosity correlations derived from data obtained at low to moderate pressures and temperatures cannot be confidently extrapolated to predict gas viscosity at HPHT conditions. [5] performed better than other evaluated correlations with the mean relative error of -16.88 and 16.88 absolute errors at 370 o F followed by [8] with a mean relative error of -20.27 and 20.27 absolute error. [8] came out best at 270 o F with a mean relative error of -5.22 and 8.752 for absolute mean error followed by [5] with a mean relative error -14.405 and absolute error of 14.405.The findings from this analysis show the need to measure the viscosity and develop correlations for HPHT conditions in order to ensure better reserves estimation. ACKNOWLEDGMENT The authors would like to thank the sponsors of World Bank African Center of Excellence for Oil Field Chemicals Research for supporting this project and Laser Engineering and Consultant Resource Port Harcourt, Nigeria where the experiment was conducted. REFERENCES [1] E. Davani, K. Ling, C. Teodoriu, J. McCain and G. Falcone Inaccurate Gas Viscosity at HP/HT Conditions and its Effects on Unconventional Gas Reserves Estimation, SPE 122827, 2009. [2] N. L. Carr, R. Kobayashi, and D. B.Burrows Viscosity of Hydrocarbon Gases under Pressure, Trans-AIME, Vol.201, 1954, pp. 270-275. [3] D. E. Dean and L. I. Stiel : The Viscosity of Nonpolar Gas Mixtures at Moderate and High Pressures. AIChE.526-532. [4] A. L. Jossi, L. I. Stiel and G.Thodos, The Viscosity of Pure Substances in the Dense Gaseous and Liquid Phases, AIChe Journal Vol. 8, 1962, No.1; 59-62. [5] J. R. Computer Routine Treats Gas Viscosity as a variable, Oil and Gas Journal, 1965, pp. 141-143. [6] A. J. Lee, M. H. Gonzalez and B. E. Eakin, The Viscosity of Natural Gases, JPT, Trans., AMIE, 37 1996, pp. 997-1000. [7] F. E. Londono, R. A. Archer, and T. A. Blasingame, Simplified Correlations for Hydrocarbon Gas Viscosity and Gas Density- Validation and Correlation of Behavior Using a Large-Scale Database, SPE Paper 75721, presented at SPE Gas Technology Symposium held in Calgary, Alberta, Canada, 2002. [8] P.U. and I. N. Abu A New Correlation for the Viscosity of Natural Gas Viscosity SPE, 106391, 2008. [9] K.Ling, E. Davani, C. Teodoriu, J. McCain and G. Falcone Measurement of Gas Viscosity at High Pressures and High Temperatures International Petroleum Technology Conference held in Doha, Qatar, IPTC 13528, 2009. [10] O. M., Anyiador, S. S. Ikiensikimama, and I. I. Azubuike, Evaluation of Viscosity Correlation for Niger Delta Gas Reservoir, International Journal of Science and Engineering Investigations, Vol 4, Issue 46, ISSN: 2251-8843, 2015. [11] E. W Comings, B. J. Mayland and R. S Egly The Viscosity of Gases at High Pressure University of Illinois Engineering Experiment Station Bullentin Series No. 354. 1944. [12] M.B Standing Volumetric and Phase behaviour of Oil field Hydrocarbon system, SPE Dallas, 1977, pp 125-126. [13] A Viswanthan,. Viscosities of Natural Gases at high pressure and high Temperature Texas A&M University, 2007. [14] National Institute of Science and Technnology (NIST). Web-Book of Thermodynamic Properties of Fluids, 2008. International Journal of Science and Engineering Investigations, Volume 5, Issue 54, July 2016 162