G7S Hand Pump Owner s Manual

Similar documents
User Instruction Manual

HUBEN K1 Pre-charged Pneumatic Air Rifle Owner s Manual

Windy City II. User instruction manual WARNING: Fill pressure: 200 bar (approximately 2,900 psi)

Tactical Sniper air rifle & carbine

TactAir PCP Fill Kit/Adapter. Operation Manual

User Operation Manual and Safety Instructions

Carbon Fiber Tank with EZ Fill system Fill pressure 4,500 psi (310 bar) Output: up to 4,500 psi (310 bar)

Puncher PCP Models. User Instruction Manual. Fill pressure: 200 bar (approximately 2,900 psi) Ver: 8/17

IZH 60/61 air rifle owner s manual

IZH 53M air pistol owner s manual

IZH 46M air pistol owner s manual

Monster Windy City Leopard

Aluminum 13 cu tank Includes regulator Fill pressure: 3,000 psi (200 bar) Output: 1,100 psi +/- 10% (75bar)

Beeman Precision Airguns Spring-Piston Air Rifles P1, P3, P11

Freedom8 ShoeBox Compressor Manual

User Instruction Manual

Beeman Precision Airguns R-Series Air Rifle Owner s Manual

Not a toy. Adult supervision required. Misuse or careless use may cause serious injury or death. May be dangerous up to 500 yards (457 meters).

Light Hunter Recluse Dragon Claw

ISSC M22. User instruction manual. 16. Repair Service. BRAND: ISSC.177 (4.5 mm) Steel BBs DESCRIPTION:

User Instruction Manual

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Vessel Installation and Operating Manual

.177 Cal. CO2 BB Tactical Rifle

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Installation and Operating Manual

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Carbon fiber tank Includes regulator & fill station with hose Fill pressure: 4,500 psi (310 bar) Output: 2,900 psi +/- 10% (200 bar)

KJ4000 Operating Instructions & Parts Manual NSN

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

200 PSI HIGH-FLOW AIR SOURCE KIT

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

Halestorm & Halestorm-10 PCP Air Rifle INSTRUCTION MANUAL PLEASE READ THIS MANUAL BEFORE USING YOUR AIRGUN

Pressure Dump Valve Service Kit for Series 2300 Units

200 PSI FAST-FILL AIR SOURCE KIT

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

100C Air Compressor Kit

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

RULES FOR SAFE FIRING:

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

IMPORTANT SAFETY INSTRUCTIONS

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

400C & 450C DUAL PERFORMANCE VALUE PACKS

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

AIR STAPLER MODEL: CSG1C Part No

200 PSI COMPRESSORS - MODEL NUMBERS

444C DUAL PERFORMANCE VALUE PACK

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Copyright Trek Bicycle Corporation 2005 All rights reserved

OWNER'S MANUAL

MODEL NUMBER: P PORTABLE COMPRESSOR

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Hydraulic Punch Drivers

RG2200 BC Integrated Octopus

Pressure Dump Valve Service Kit for Series 3000 Units

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

MODEL NUMBER: P PORTABLE COMPRESSOR

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Yoke Block Instruction Manual

trigger magazine release

CSA Sample Draw Aspirator Adapter Operator s Manual

NTO-200 Operation Manual

RG3100 and RG3100Ice Regulator System

Yoke Block Instruction Manual

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

Cocoa Patio Pond with Lit Spillway

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

SPECIFICATIONS APCEPH1

instruction manual highpressure handpump manual

Inflatable Stand Up Paddle Board Manual

FX IMPACT OWNER S MANUAL

MODEL Beretta 92FS. Caliber.177 (4.5 mm) Pellet CO 2 Air Pistol. Operating instructions 3-15

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Installation Instructions Air Compressor Part # 2780, 2781

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

RK LEL Sample Draw Aspirator Adapter Operator s Manual

AIR HYDRAULIC RIVETER

Adjustable. Unloader Valve. O&M Manual. Part #

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

KJ1000 Operating Instructions & Parts Manual NSN

SERVICE MANUAL. Technical Bulletin No GEOPROBE GH40 HYDRAULIC HAMMER. PREPARED: February, REVISED: April, 2002 A DIVISION OF KEJR, INC.

Operation and Maintenance Instructions

480C DUAL PERFORMANCE VALUE PACK

Transcription:

G7S Hand Pump Owner s Manual Copyright Air Venturi 2018 Version 4-18

Specifications 24.80 inches long closed 43.31 inches long extended 4500 psi/310 bar max pressure Features Integral manometer (pressure gauge) Folding footplate Test plug Comfortable, ergonomic handles Micro-bore hose Easily accessible bleed valve Accessories 43.31 inches long extended 4500 psi/310 bar max pressure Features 01: Spanner Wrench wrench... 1 pc pc 2: High-pressure Stem Sealing Ring... 2 pcs 3: High-pressure Piston Ring... 2 pcs 4: O-ring... 5 pcs 5: Outer Tube Piston Ring... 2 pcs 6: Check Valve Spring... 2 pcs 7: Sealing Gasket for Bleed Valve... 2 pcs 8: High-pressure Piston Spring... 2 pcs 9: Low-pressure Piston Ring... 2 pcs 10: Seal Ball (for one-way inlet hole)... 2 pcs 11: High-pressure Spool Valve... 2 pcs 12: Allen Wrench... 1 pc 13: Maintenance oil... 1 pc 14: Female Quick-disconnect... 1 pc 15: Test Plug... 1 pc 16: T Wrench... 1 pc Easy accessible bleed valve Flexible hose with spiral steel cage Quick-disconnect with female coupling One-year warranty 02 03 04 01 06 06 07 13 12 08 09 07 08 11 10 11 12 14 14 16 15 17 13 15 05 10 09 16 If you need technical or maintenance help, call Air Venturi tech support: 216-220-1180

A B G A: B: C: D: E: F: G: H: F Rubber grip with filters Pump cylinder Base plate Pressure gauge Hose Female quick-disconnect coupling Test plug Bleed valve E D H C

Testing 1. Insert the test plug (G) into the female quick disconnect (F) 2. Be sure the collar on the female fitting snaps forward when installing, securing it in place. In some cases, you may have to push the collar forward into the secure position 3. Apply tension to the female fitting in an attempt to pull it off of the male fitting to make sure the connection is secure. If for any reason the male and female connectors separate during this process, contact Air Venturi tech support at 216-220-1180. 4. Open the bleed valve (H) completely 5. Pump the handle rapidly about 20 times - you should face little/no resistance during pumping. This ensures that there is no air built up in the line. 6. Tighten bleed valve (H) completely 7. Pump the handle rapidly until the gauge reads 100 bar/1450 psi 8. Open the bleed valve (H) to release air

Operation 1. Before you start pumping: 2. Make sure the bleed valve is tightened completely. 3. Stand on the pump s footplate to stabilize the unit. 4. Make sure hose is straight (no kinks or bends) 5. Connect the pump to the reservoir/airgun you want to fill with air. 6. Be sure the collar on the female fitting snaps forward when installing, securing it in place. In some cases, you may have to push the collar forward into the secure position. 7. Apply tension to the female fitting in an attempt to pull it off of the male fitting to make sure the connection is secure. If for any reason the male and female connectors separate during this process, contact Air Venturi tech support at 216-220-1180. 8. Start pumping by pulling the handle completely up, pause, then push pump handle all the way down. The pressure will initially spike, and as you continue pumping, it will rise slowly.* 9. As you continue to pump, you will experience increased resistance as the pressure in the reservoir increases. 10. Repeat pumping until the gauge shows you ve reached the desired pressure. Be sure to not overheat pump. 11. Once desired pressure reached, open the bleed valve quickly to release the remaining air in the hose. You may see water vapor/water drops when bleeding out the air - this is normal. Important: Open Bleed valve on pump quickly and fully, do not bleed slowly. This ensures the check valve on the airgun or container closes completely and immediately. If you are filling a scuba or carbon fiber tank that has a shut-off valve, you will need to shut off the valve before opening the bleed valve on the pump. * Several quick strokes may be required to initially seat seals in some filling adapters and valves. Once gauge shows gaining pressure, slow down to prevent overheating.

TWrench Spanner Wrench Fig. 7-2 Replace the o-ring as shown above. Fig. 7-3 Using the spanner wrench, open the check valve in the base plate. Clean or replace the check valve.

Fig. 7-4 Lubricate pump with silicone oil as shown. Lubricate pump with silicone oil as shown. Pump up and down several times (without connecting to a reservoir or tank and without using the test plug) after adding the silicone oil. Any excess oil must be drained from the pump through the pumping action in order to avoid the possibility of an explosion. When you bleed the air from the hose, you may hear hissing and the sound of water as the air is released. That s the residual air left in the hose. The larger the volume of air, the louder the sound. If it s exceptionally loud or louder than what you ve previously experienced, the check valve of the reservoir or container may not be functioning properly. It s also possible the valve in the reservoir or tank may be defective, loose or not working properly. To ensure the check valve on the gun or container closes completely and immediately, fully and quickly open the bleed valve on the pump. Do not slowly or partially open the pump s bleed valve. To determine if it s the pump or the device that s being filled, use the pump to fill other tanks or reservoirs. If the other items do not exhibit the same issues, then the pump is not the cause of the problem.

One-year Two-year limited warranty The G6 G7S pump pump is is warranted warranted to to the the retail retail consumer consumer for for two one (2) year years from from date the date of retail of retail purchase purchase against against defects defects in material in material and workmanship. and workmanship. What is covered: Replacement parts and labor. Transportation charges to consumer for repaired product. What is NOT covered: (1) Transportation charges to Air Venturi for defective products. (2) Damages caused by abuse or failure to perform normal maintenance. (3) Parts subject to normal wear and tear. (4) Consequential damages, incidental damages or incidental expenses including damage to property. (5) Any other expense. NOTE: Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Warranty claims for U.S. and Canadian customers: Return product to Air Venturi. Call Air Venturi at 216-220-1180 before returning any product. Implied warranties: Any implied warranties, including the implied warranties of merchantability and fitness for a particular purpose, are limited in duration to two one years from date of retail purchase. NOTE: Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. To the extent any provision of this warranty is prohibited by federal, state or municipal law which cannot be preempted, it shall not be applicable. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state and country to country. Illustrations and photographs are for information purposes only and may not show the exact model purchased. Warranty will be invalid if: (1) The pump has been incorrectly disassembled or reassembled. (2) The pump is found to have lubrication not recommended by Air Venturi. (3) The pump has been fitted with non-air Venturi parts. (4) The pump has been misused or abuse. (5) The original purchase receipt cannot be presented. Warranty does NOT cover: (1) Any damage or faults caused by owner misuse or action. (2) Shipment damage of the pump to or from Air Venturi. This warranty is in addition to your statutory rights. Retain your sales receipt as proof of purchase, as it will be required to obtain warranty service.

! WARNING: DO NOT DISASSEMBLE ANY JOINT WHEN THERE IS ANY RESIDUE AIR IN THE PUMP! DOING SO MAY BE DANGEROUS AND WILL VOID YOUR WARRANTY. DO NOT PUT ANY PART OF YOUR BODY NEAR THE BLEED VALVE AIR VENT OR POINT THE VENT AT PEOPLE OR ANIMALS. THE BLAST OF AIR AND WATER MAY CAUSE INJURY OR DEATH. Troubleshooting Issue #1 The pressure gauge needle isn t moving or seems to be moving very slowly even though you ve been pumping for some time. Cause: You didn t close the bleed valve. Solution: Close the bleed valve. Cause: Air leak in the pump or hose. Solution: Test Follow for step slow 10 leaks in Testing by putting section the pump to find base, the hose leak. and test plug in water to see if there are bubbles, which indicate leaking air. Issue #2 While pumping, the upward stroke is light Issue #2 --While pumping, the upward stroke is light but the downward stroke is heavy...or the pump handle but the downward stroke is heavy...or the pump handle pushes pushes up by up itself. by itself. Cause: Cause: Faulty Faulty o-ring. o-ring. Solution: Refer to figure 7-2 to replace o-ring. Issue #3 During pumping, the upward pull is very heavy, and the pump handle is automatically sucked back down without manual effort. Cause: Dirt in the check valve. Solution: Remove dirt from check valve. Cause: Check valve in the base plate is damaged or isn t sealing for another reason. Solution: Refer to figure 7-3 to replace or fix check valve. Issue #4 Upward and downward strokes are unusually heavy. Cause: Lack of oil. Solution: Refer to figure 7-4 to properly lubricate. Issue #5 Pressure gauge needle doesn t point to zero. Cause: Defective pressure gauge. Solution: Replace pressure gauge. If you need technical or maintenance help, call Air Venturi tech support: 216-220-118

Notes

Notes

AIR VENTURI 5135 Naiman Parkway, Cleveland, OH 44139 216-292-2570 fax 216-373-0086