In situ permeability measurement with the BAT Permeameter. Quick Manual Ou low test. Warranty details

Similar documents
In situ permeability measurement with the BAT Permeameter. Quick Manual Inflow test. Warranty details

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Please Do Not Return This Product To The Store!

ROPV R40 E Series User Manual

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Helios Separable Tandem Manual

Unisense In Situ UniAmp Connector System

User s Manual. USB Golf Simulator. Contents

TR5000 THE TOUGHEST TRAINING SYSTEM ON THE PLANET. MODEL NO. STRIKER TRAINER 2L Escalade Sports

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-300. Club Volleyball Gear. For fixed-height Basketball Hoop Systems

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

RADROVER REAR RACK INSTALLATION MANUAL

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

User s Guide. Vacuum Controller for liquid delivery systems

OWNER'S MANUAL. Copyright 1999 ATS - All Rights Reserved

INFERNO 20-IN-1 MULTI-GAME TABLE ASSEMBLY INSTRUCTIONS

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

7 FOOT POOL TABLE WITH TABLE TENNIS TOP ASSEMBLY INSTRUCTIONS

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

Golf Performance Monitors. PureContact Operating Guide. Version of 9

SDX Submersible Depth Transmitter User Manual

ACCU-MIX 1200 / / 26270

SPS-5. Rate Computing Scale. Operation Manual

PARK AVENUE 7' POOL TABLE WITH TABLE TENNIS & BENCHES ASSEMBLY INSTRUCTIONS

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

602 STRINGING MACHINE OWNER'S MANUAL

User Instruction Manual

Installation & Instruction Manual For Portable Series R.O. units:

OWNER'S MANUAL. Copyright 2003 GAMMA - All Rights Reserved

Methods for Measuring Groundwater Elevation and Vacuum Pressure During Soil Vapor Extraction

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Parts Manual. Frusheez Machines

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-200. Club Volleyball Gear. For height-adjustable Basketball Hoop Systems

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Instruction Manual Model Borehole Pressure Cell

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Pressure Relief Valve Instruction Manual

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

RK-IR Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Model No Product Name Handpiece Only Complete System

Operation Manual. O2 Quickstick. Oxygen Analyzer

SPECIFICATIONS APCEPH1

Installation and Operating Instructions

Vessel Installation and Operating Manual

User Manual. ECC-Opto-Gas. Release Electrochemical test cell EL-CELL GmbH

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

SASK-A-POLE OWNERS AND USERS MANUAL

Corning Step-R. Repeating Pipettor. Instruction Manual

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Yoke Block Instruction Manual

User s Guide. Pressure Controller for liquid delivery systems

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-400. Club Volleyball Gear

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

PERSONAL AIR BREATHING UNIT

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

SDX Submersible Depth Transmitter User Manual

600 / 600FC OWNER'S MANUAL

STATEMENT OF LIABILITY

400C & 450C DUAL PERFORMANCE VALUE PACKS

3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide

Model ASSEMBLY and OPERATING INSTRUCTIONS

LogIT Dissolved Oxygen Probe

AA100 Acoustic Actuator

Installation and Operating Manual

INSTRUCTIONS warranty watch care

SERIES L4E & L6E LADDER EXTENSIONS

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

NEULOG OXYGEN LOGGER SENSOR GUIDE

Flexi-pro Aerosol Delivery System (FADS) Manual

Challenge Friends, Get Ranked and Earn Points with the FUTCHI_App Players

EVO Solid Downtube. Operators Manual for Downtubes fitted with zinc plated springs June 2004

Installation & User Guide. English Version 1.0

FLANGED MULTI-PORT BALL VALVES

Angled Sign Light with Shade

FLANGED TWO-PIECE BALL VALVES

Cocoa Patio Pond with Lit Spillway

Cylinder Tilt Saddle Instruction Manual

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-100. Club Volleyball Gear WARNING

ORBITAL AIR SANDER. Owner s Manual

Transcription:

Warranty details In situ permeability measurement with the BAT Permeameter Quick Manual u low test BAT Geosystems AB (BAT) warrants all new BAT products against defects in materials and workmanship for a period of 12 months from the date of invoice. During the warranty period, we will repair or, at our option, replace at no charge a product that proves to be defective provided that it is returned, shipping cost prepaid, to BAT. BAT s liability and obligations in connection with any defects in materials and workmanship are expressly limited to repair or replacement, and the sole and exclusive remedy in the event of such defects shall be repair or replacement. BAT s obligations under this warranty are conditional upon it receiving prompt written notice of claimed defects within the warranty period and it s obligations are expressly limited to repair or replacement. This warranty does not apply to products or parts thereof which have been altered or repaired outside of the BAT factory, or products damaged by improper installation or application, or subjected to misuse, abuse neglect or accident. BAT Geosystems AB will not be liable for any incidental or consequential damage or expense incurred by the user due to partial or incomplete inoperability of it s products for any reason whatsoever or due to inaccurate information generated by its products. All warranty service will be completed as soon possible. If delays are inavoidable customers will be contacted immediately. BAT Geosystems AB Box 1060 186 26 Vallentuna Tel +46851170600 Fax +46851173361 BAT Geosystems AB Hällebergsvägen 5 443 60 Stenkullen Tel +46317890600 Fax +46851173361 www.bat-gms.com info@bat-gms.com Ver 2011-02-14

Contents Pre-test measures Page Pre test measures 1 Introduction BAT Permeameter 2 BAT Permeameter Equipment 3 Assembly of equipment - Layout 4 Assembly of equipment - Stepwise 5 Setup of outflow test 7 Starting the BAT Permeameter test 9 Finishing the test 10 Test sheet - Inflow test 11 Test sheet - utflow test 12 1) Installation of BAT MKIII Filter Tip Install a BAT MKIII Filter Tip at desired depth and location. Follow the instructions from the Installation of the BAT MKIII Filter Tip -guide. 2) Measurement of pore pressure Measure the actual pore pressure. Follow the instructions given in the BAT Pore Pressure Guide. Dissipation of disturbance effects When the BAT Filter Tip is pushed into the soil, excess pore pressures will be generated due to disturbance effects. The time needed for dissipation of these disturbance effects varies with the type soil. In soft, plastic clays lays it may take several days until the original pore pressure is restored. n the contrary, in stiff clay, silt and fine sand the dissipation of the excess pressures goes much quicker. The process of dissipation of excess pore pressures can be logged by the BAT Sensor. Make sure that the installation excess pore pressure has dissipated.before starting a permeability test. If unsure, leave the sensor connected to the BAT Filter Tip for 10 minutes. If, during this period, the he reading is stable (±0.01m H2) a permeability test can be performed. 3) Checking BAT Sensor Make sure that the battery unit of the sensor contains a fresh, akaline battery. If unsure, change the battery. Normal life time of a battery when constant logging (1 minute interval) is about 3-4 weeks. page 1

Introduction BAT Permeameter BAT Permeameter Equipment The BAT Permeameter can measure permeabilites, k, in the range from 1*10-7 m/s and lower. An example of typical k-values for different soil types: Fine gravel: 1-1*10-2 m/s Coarse sand: 1*10-1 m/s - 1*10-3 m/s Medium sand: 1*10-2 m/s - 1*10-4 m/s Fine sand: 1*10-3 m/s - 1*10-5 m/s Coarse silt: 1*10-4 m/s - 1*10-6 m/s Medium silt: 1*10-6 m/s - 1*10-7 m/s Fine silt: 1*10-7 m/s - 1*10-8 m/s Clay: <1*10-8 m/s Typical time for stabilisation for different k-values, i.e. time of testing: k 10-7 m/s ; t stab 1 minute k 10-8 m/s ; t stab 10 minutes k 10-9 m/s ; t stab 1 hour k 10-10 m/s ; t stab 10 hours Theory of the BAT Permeability Test The BAT Permeability Test is a type of falling head test. The evaluation of the test is made by using Hvorslev s equation * ). Parameters: F = Hvorslev s flow factor mm BAT MKIII Standard: 230 mm BAT MKIII Vadose: 194 mm k = coefficient of permeability m/s U 0 = equilibrium pore pressure in-situ (absolute) m H 2 P 0 = initial system pressure (absolute) m H 2 P m = system pressure at time t (absolute) m H 2 V 0 = initial system volume of air t = time for the test s At any time t the corresponding coefficient of permeability k can be calculated using the following equation: k = P 0 V 0 /(F t 10 3 ) {1/U 0 P 0-1/U 0 P m + 1/U 02 ln[(p 0 U 0 )/P 0 P m /(P m - U 0 ]} Contents: 1. Test container housing 2. Test container (35 ) 3. Extension adapter 4. Quick coupling sleeve 5. Spare screws and springs 6. Screwdriver for moun ng of double ended needle 7. Spare septas 8. Syringes (25 & 10 ) 9. Container for used needles 10. Double ended needles 11. Vacuum pump with Manometer(see APPENDIX 1 for use of the Vacuum Pump) 12. Blue needles 13. Cable Clamp page 2 page 3

Assembly of equipment Layout Assembly of equipment - Stepwise BAT-sensor #1-200 / 1-204 Transfer nipple & extension adapter screw the transfer nipple until it seats in the sensor cavity. Firstly, make sure the parts all are dry. Attach a blue needle onto the transfer nipple. Mount the extension adapter onto the transfer nipple. WARNING! Sample may be pressurized o-ring 11.1x1.78mm #3-212 Transfer nipple #3-202 Blue needle #4-401 Extension adapter Test container housing Test container PRECAUTINS Handle all parts carefully, especially the glass containers. Use only sharp needles. In general do not re-use needles, especially in case the set is used for sampling. Store the set in a dry climate. Do not use any tools to assemble the set. Finger tight is enough. Test container utflow test - unsaturated soil conditions pen the test container in one end by removing the screw cap and the septum. Fill the test container with a selected volume of water, using a syringe. See PAGE 7 for more details. Close the test container. Finger tight is enough! Container housing assembly and connection of IS Field Unit Carefully insert the test container into the container housing. Screw the extension adapter onto the open end of the container housing. Connect the IS Field Unit, choose Display Mode (see page 7). The pressure in the test container can now be measured with the IS Field Unit (see also APPENDIX 1). After assembly hold the test unit horizontal or pointing downwards. Double ended needle N.B. Remove the small rubber guard Quick coupling Spring 0.75x9x15mm page 4 page 5

Assembly of equipment Stepwise Setup of utflow Test Application of initial system pressure P 0 utflow test The initial system pressure P 0 is applied by injecting or extracting a volume of air, V, to/from the test container, using a syringe, equipped with a blue, hypodermic needle. The applied pressure P 0 is directly displayed by the IS Field Unit. For calculation of P 0 and V, see APPENDIX 1. N.B. Normally, when the test equipment is lowered down the extension pipe the temperature will drop. Accordingly the applied initial pressure will be changed. For example a temperature drop of 10 o C will reduce the applied intial pressure P 0 by about 5%. Unsaturated soil conditions & negative pore pressure situation For unsaturated soil conditions the BAT Permeability test must be carried out as an outflow test. It is also assumed that a negative pore pressure situation is prevailing, i.e.: U 0 p atm. This condition is normally prevailing for compacted clay liners. For outflow tests in unsaturated conditions the BAT MKIII Vadose is needed. The outflow test starts with a partly water-filled Test container. Initial water volume V H2 Porewater pressure interval 8 U 0 p atm For the porewater pressure interval of 8 U 0 p atm : V H2 = 10 () Porewater pressure interval 1 U 0 < 8 The water volume, V H2, for pressure interval 1 U 0 < 8 is calculated as follows: V H2 ( 35 3,1 U 0 ) () The volume V H2 is injected without using the blue needle. Double ended needle & Quick coupling sleeve Prepare the double ended needle for mounting. N.B. Remove the small rubber hose. By using the needle adapter in the handle of the screwdriver, screw the double ended needle until it seats into the quick coupling sleeve. IMPRTANT! Make sure that the needle seats properly in the thread. Finally, screw the quick coupling sleeve onto the container housing. Initial system pressure P 0 Depending on the magnitude of the equilibrium pore pressure U 0 the following initial system pressures P 0 are recommended: Equilibrium pore pressure interval (m H 2 ): 9< U 0 p atm 8 U 0 9 1 U 0 < 8 Recommended initial system pressure (m H 2 ): P 0 =1,1 U 0 P 0 = 1,25 U 0 P 0 = p atm All pressures are in absolute values. With the sensor and field unit connected the system pressure P 0 is adjusted with a syringe and blue needle. Continue to page 9! P 0 U m (absolute pressures) Sensor: PA1082 8 JUN 11:37:03 17.22-10.31 = 6.91 m H2 p atm p m u m (relative pressures) P 0 = System pressure in test container U m = sensor pressure (if BAT Permemeter not connected) U 0 = pore pressure = U m + 0.2m H2 (pressure head compensation) page 6 page 7

Starting the BAT Permeameter test Finishing the test With the system pressure P 0 (and V H2 for the outflow test) set correctly the next step is as follows: Temperature equilibrium With knowledgde of the installation depth, use the cable clamp to fix the cable and let the BAT Permeameter rest above the filter tip before the test. With the BAT/IS-Field Unit connected you can monitor the temperature equilibrium process. When the system pressure P 0 is stable note this value in the test sheet. Starting the test 1) Prior to the start of the test, prepare the Field Unit by opening the Start Measure menu. Select both sensor and temperature logging (sensor+temp) and a suitable time interval. To start with it is recommended to use 1 min logging interval. At a later stage of the test the logging interval can be changed (increased) without any inteferece with the ongoing logging of test data. 2) Thereafter, place the marker on the K-option at the bottom of the menu, without starting the logging. 3) The next step is to connect the test equipment to the BAT Filter Tip. Thus, remove the cable clamp and gently lower the equipment the remaining 0.2 0.3 m down to the Filter Tip. At the same moment the equipment connects to the Filter Tip, press K on the Field Unit and the test is running. pen the Display menu of the Field Unit to have a visual check that the test is running, i.e the pressure shall gradually change. When P 50 (or P 80 ) is reached the test can be terminated by following the steps below: 1) Note the value of P end in the test sheet. 2) Gently pull the equipment from the installation and measure the volume water inside the test container. This is the V end -value in the test sheet. The volume can be measured by pouring the liquid into a syringe sealed with a rubber septa to the needle. It can also be measured more accurately at the office at a later stage. 3) Note the atmospheric pressure at the end of the test. This might be of importance if dramatic weather (pressure) changes has occurred during the test. Now the field part of the test is completed. Please refer to the In situ permeability measurement with the BAT Permeameter -manual for evaluation of the permeability. If running more tests before downloading the data to a PC, just remember do not clear the data between the tests. Keep notes on the starting time and starting pressures of each test and each set of test data is easily separated when processing it on a PC. 4) Depending on soil type the testing time may vary from 5 minutes up to 24 hours or more. After about one hour the measuring interval of the sensor can be increased to 10 minutes or more. This is simply done by activating the Start measure function of the BAT/IS-Field Unit and select a new logging interval. 5) The test can normally be evaluated at a pressure equalization of 50-80% (P 50 - P 80 ). Before finishing the test take a reading of the atmospheric pressure and fill in the value in the Test Protocol. page 8 page 9

TEST SHEET - UTFLW TEST Site Measuring point: Date/Time BAT Sensor no Installation depth of filter tip m Test performed by Type of filter tip BAT MKIII Standard BAT MKIII Vadose Initial atmospheric pressure time Final atmospheric pressure time U 0, pore pressure at equilibrium (U0 = Um + 0.2 mh2) P 0, system pressure at start of test (at temperature equilibrium) (displayed Pm value) P 50, system pressure at 50% pressure recovery (calculated) P50 = P0-0.5(P0 - U0) P 80, system pressure at 80% pressure recovery (calculated) P80 = P0-0.5(P0 - U0) Pend, final system pressure (measured) V V, volume liquid in system at start of test V 0, volume of air in system at start of test (35-V V ) V calc, calculated volume liquid in system at end of test Vcalc = [P0VV - 35(P0 - Pend)]/Pend V end, measured volume liquid in system at end of test Coefficient of permeability, k = *10- m/s, calculated at % pressure equalisation Notes: