CALIBRATION SYSTEM REQUIREMENTS. ESCC Basic Specification No

Similar documents
Recommended Practices for Calibration Laboratories

RESISTORS, HEATERS, FLEXIBLE, SINGLE AND DOUBLE LAYER. ESCC Detail Specification No. 4009/002

Radon Chamber Accreditation Policy. 1.0 Introduction

EN ISO/IEC Technical Requirements

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

92831 TEL: (714) FAX:

CORESTA RECOMMENDED METHOD N 6

CALIBRATION AND TRACEABILITY: ITS IMPORTANCE IN THE GAS INDUSTRY

RULES FOR CLASSIFICATION Naval vessels. Part 1 Classification and surveys Chapter 5 Surveys for submarines. Edition January 2016 DNV GL AS

How to evaluate pressure measurement specifications

Traceable calibration of automatic weighing instruments in dynamic operation

INTERNATIONAL STANDARD

SAFETY FEATURES OF PORTABLE CRYOGENIC LIQUID CONTAINERS FOR INDUSTRIAL AND MEDICAL GASES

technical guide Laboratory Balances Calibration Requirements

E2.14 Control of Hazardous Energy. Effective Date: 03/01/2018

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

Standard Operating Procedure Measuring & Testing Equipment

Light Lab. Reliable Measurements through Regular Calibration. DAkkS

1811G/H PITOT-STATIC TEST SET

Gerald D. Anderson. Education Technical Specialist

TEXAS DEPARTMENT OF PUBLIC SAFETY Breath Alcohol Laboratory

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Understanding safety life cycles

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

ISO INTERNATIONAL STANDARD. Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor

General Accreditation Guidance. User checks and maintenance of laboratory balances

Personal Protective Equipment (PPE) Hydrogen Fluoride Hydrofluoric Acid Solutions

1. Scope: This document describes the procedure for verifying the performance of vaccine vial monitors.

THE FUNDAMENTALS OF THE AIR SAMPLER CALIBRATION-VERIFICATION PROCESS

HAZARDOUS WASTE OPERATIONS AND EMERGENCY RESPONSE

Balancing and Settlement Code. Code of Practice Four

PORTS AUSTRALIA. PRINCIPLES FOR GATHERING AND PROCESSING HYDROGRAPHIC INFORMATION IN AUSTRALIAN PORTS (Version 1.5 November 2012)

GMC-I Service GmbH Calibration Center

Accreditation for In-Service Inspection of Transportable Pressure Receptacles (TPRs)

ISO/TR TECHNICAL REPORT. Natural gas Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation)

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

20. Technical Equipment. Archived. This section applies to all equipment used in forensic examinations, such as

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

POWER Quantifying Correction Curve Uncertainty Through Empirical Methods

BCGA GUIDANCE NOTE 17

White paper. Fit for Purpose. Product Testing & Performance. Constant Force post system

Systems of Accounting for and Control of Nuclear Material

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

PRESSURE SYSTEMS POLICY

AUSTRALIAN MEN S HANDICAPPING SYSTEM (Copyright)

I N N O V A T I O N C O N T I N U E S... International Patent Filed in 45 Leading Countries

Application Note AN-107

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Title: INSTRUMENT AND EQUIPMENT DOCUMENTATION AND RECORDS

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)

Veriforce TG CCT 609OP. Training Guide

Service ISO17025 explained

Instruction Manual EMA 84 Digital Pressure Gauge

CALIBRATION CERTIFICATE # 500

for the of and the EM55-1

WORKPLACE SAFETY AND HEALTH ACT (CHAPTER 354A) WORKPLACE SAFETY AND HEALTH (CONFINED SPACES) REGULATIONS 2009

ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN

Gas mixtures. Individual solutions specifically for your application

GUIDANCE FOR THE APPLICATION OF EQUIPMENT CALIBRATION AND TRACEABILITY OF MEASUREMENTS ON INSPECTION BODIES

2014 Programme of Training Courses in Measurement & Calibration

DQM Annual Hopper QA Checks

Metering Code Gas TSO, measurement by connected party Effective from to the present

Vehicle- or rack-mounted liquefied gas meters, pump supplied

Piped Air SCBA Refilling System Standard

OHRP Guidance on Written IRB Procedures

GUIDE YVL 3.7 / 26 Se p t e m b e r 2008

CONTRACTOR WHS HAZARD STANDARD HAZARDOUS CHEMICALS EXTERNAL USE ONLY

WIKA INSTRUMENT CORPORATION

Eliminating Sources of Pipetting Error in the Forensic Laboratory David M. Epstein Director of Scientific Operations. Abstract.

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

United States Figure Skating Association Eligible Skater s Compensation Agreement Program (ESCA)

FEDERATION OF PILING SPECIALISTS CODE OF INDUSTRY BEST PRACTICE LIFTING OPERATIONS AND LIFTING EQUIPMENT REGULATIONS 1998

Operating and maintenance manual Filter and reducing station Series / 1.0

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

Health & Safety Policy & Plan. Rightway Roofing.

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Accreditation for In-Service Inspection of Pressure Systems/Equipment

Any use of this material except in accordance with a written agreement with Western Power is prohibited.

2019 USEF Dressage Test Diagrams First Level

Start-up, Shutdown and Malfunction Plans. Norman L. Morrow Fresh Air Consulting

ACCREDITATION OF ON-LINE LEAK SEAL ORGANIZATIONS

Improve Process Reliability

A New Piston Gauge to Improve the Definition of High Gas Pressure and to Facilitate the Gas to Oil Transition in a Pressure Calibration Chain

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device

Finding Leak Testing Success Through Calibration and Validation. Paul Chamberlain President, CEO

HI 2314 HI 2315 HI 23151

Ambient Weather WS-03 Thermo-Hygrometer

FPG8601 Force Balanced Piston Gauge

Ultima. X Series Gas Monitor

SKSTEX36(SQA Unit Code-H7C9 04) Calibrate textile production equipment

Personal Protective Equipment

ICHEME SYMPOSIUM SERIES NO. 144

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

BRITISH STANDARD BS 341-4: Transportable gas container valves. Part 4: Pressure relief devices ICS

Best Practice for Calibrating LTH Conductivity Instruments

(NIST Special Publication )

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

Transcription:

Page 1 of 8 CALIBRATION SYSTEM REQUIREMENTS ESCC Basic Specification Issue 4 February 2014 Document Custodian: European Space Agency see https://escies.org

PAGE 2 LEGAL DISCLAIMER AND COPYRIGHT European Space Agency, Copyright 2014. All rights reserved. The European Space Agency disclaims any liability or responsibility, to any person or entity, with respect to any loss or damage caused, or alleged to be caused, directly or indirectly by the use and application of this ESCC publication. This publication, without the prior permission of the European Space Agency and provided that it is not used for a commercial purpose, may be: copied in whole, in any medium, without alteration or modification. copied in part, in any medium, provided that the ESCC document identification, comprising the ESCC symbol, document number and document issue, is removed.

PAGE 3 DOCUMENTATION CHANGE NOTICE (Refer to https://escies.org for ESCC DCR content) DCR No. CHANGE DESCRIPTION 838 Specification upissued to incorporate editorial changes per DCR.

PAGE 4 TABLE OF CONTENTS 1 GENERAL 5 1.1 SCOPE 5 1.2 APPLICABILITY 5 1.3 DEFINITIONS 5 2 REQUIREMENTS 5 2.1 GENERAL 5 2.2 EQUIPMENT AND STANDARDS REVIEW 6 2.3 TRACEABILITY 6 2.4 CUMULATIVE EFFECTS OF ERRORS 6 2.5 ENVIRONMENTAL CONTROLS 6 2.6 INTERVALS OF CALIBRATION 6 2.7 CALIBRATION LABELLING 7 2.8 DOCUMENTED CALIBRATION PROCEDURES 7 2.9 RECORDS 7 2.10 SEALING FOR INTEGRITY 7 2.11 SUBCONTRACTOR CALIBRATION 7 2.12 STORAGE AND HANDLING 7 2.13 TECHNICAL MEASUREMENT EVALUATION 8

PAGE 5 1 GENERAL 1.1 SCOPE This document establishes requirements for a calibration system to be designed, established and maintained by the contractor for the purpose of ensuring that measuring equipment and standards are properly calibrated. 1.2 APPLICABILITY This document applies when referenced in a contract, purchase order or specification. 1.3 DEFINITIONS The following definitions of terms apply to this document: Accuracy The degree of correctness with which a method of measurement yields the true value of a quantity, usually expressed in terms of error. Calibration A comparison between a standard or measuring equipment, instrument or items of equipment and a standard of higher accuracy, to detect, correlate, adjust and document the accuracy of the instrument or equipment item being compared or tested. Measuring Equipment All devices used to measure, gauge, test, inspect or otherwise quantify the characteristics of an article. Precision A measure of consistency or reproducibility of measurements among themselves. Standard An instrument, device or material of known characteristics and higher precision used to establish and maintain the accuracy of a measurement system or device. 2 REQUIREMENTS 2.1 GENERAL The contractor shall maintain an effective system for the control and calibration of all measuring equipment and standards used in fulfilment of his contractual requirements whether located at the contractor s plant, a subcontractor s plant or at another location. The system shall be designed to ensure that all measuring equipment provided by the contractor has the capability to perform within designated limits. It shall provide for the prevention of inaccuracy by prompt detection of deficiencies and timely action for their correction. This document does not require the contractor to establish or maintain a complete in-plant calibration capability if calibration services are obtained from sources which meet the requirements of this document. Objective evidence that the calibration system is effective shall be readily available to the ESCC Executive. Staff employed in calibration work shall have received adequate training.

PAGE 6 2.2 EQUIPMENT AND STANDARDS REVIEW The contractor shall conduct, during the earliest practical phase of contract performance, a sufficiently extensive review of the technical requirements of the contract to ensure that measuring equipment and standards necessary for the fulfilment of the contract are available and are of the required accuracy, stability and range for the intended application. The contractor shall identify and report to the ESCC Executive any measurement requirement involving accuracy that exceeds the known state of the art. 2.3 TRACEABILITY All measuring equipment shall be calibrated using standards whose accuracy is traceable to national or international standards except where the standards have been derived from accepted values of natural physical constants or derived by the ratio type of self-calibration techniques. Contractor standards need not be referred directly to national standards but may be calibrated against intermediate standards, providing the requirement for traceability to national standards is satisfied. However, the number of echelons in the calibration structure must be limited to the minimum consistent with the need for accuracy and precision. All standards used in the calibration system shall be supported by certificates, reports or data sheets attesting to the date, accuracy and conditions under which the results were obtained. 2.4 CUMULATIVE EFFECTS OF ERRORS The cumulative effect of the errors in each component of a calibration chain shall be taken into account for each successive measuring equipment or standard calibrated. When the total is such as to significantly compromise the ability to make measurements within the permitted product tolerances, corrective action shall be taken. The basis for the calculation of the cumulative effect shall be recorded and be satisfactory to the ESCC Executive. 2.5 ENVIRONMENTAL CONTROLS Measuring equipment and standards shall be calibrated and utilised in an environment controlled to the extent necessary to assure continued measurements of the required accuracy and precision. Due consideration shall be given to temperature, temperature rate of change, humidity, lighting, vibration, dust control and cleanliness and other controllable factors affecting precision measurement. When pertinent, these factors shall be continuously monitored and recorded. When essential, compensating corrections shall be applied to measurement data obtained in a noncontrolled environment. Records shall contain both the original and the corrected data. 2.6 INTERVALS OF CALIBRATION Measuring equipment and standards shall be calibrated at periodic intervals established on the basis of their stability, purpose or degree of usage. Intervals shall be shortened when required to ensure continued accuracy dependent on the results of preceding calibrations, and may be lengthened when the results of previous calibrations provide definite indications that such action will not adversely affect confidence in the accuracy of the measurement device. The system shall provide for immediate removal or, if not movable, conspicuous identification to prevent use of any equipment for which the calibration validity date has passed. In addition, the contractor shall provide for immediate removal or identification of measuring equipment and standards which have failed in operation in one or more measurement parameters, show evidence of physical damage, or are determined to be, or suspected of being, outside of required performance limits. The ESCC Executive shall be notified of any such event so that previous results may be re-examined, to

PAGE 7 ascertain whether re-testing is necessary. New or repaired measuring equipment and standards shall be calibrated before use. 2.7 CALIBRATION LABELLING Depending on the size of functional characteristics, measuring and test equipment and measurement standards shall be labelled or coded to indicate the date of last calibration, by whom it was calibrated and the scheduled date for the next calibration. Any limitation of calibration shall be clearly indicated. When neither labelling nor coding is practicable, procedures shall be established to assure adherence to calibration schedules. 2.8 DOCUMENTED CALIBRATION PROCEDURES Documented procedures shall be prepared and used for calibration of all measuring equipment and standards used in the performance of the contract. The procedures may be a compilation of published standard practices or contractor s or instrument Manufacturer s written instructions. Calibration procedures shall include those step-by-step instructions necessary to enable personnel performing calibration functions to determine that the devices are within their prescribed limits. 2.9 RECORDS The contractor shall develop and maintain a comprehensive and complete set of records that documents the accuracy, calibration methods, precision and history of all measuring equipment and standards. The records shall include, as appropriate, the type or description of the measuring equipment, Manufacturer s name, model number and rated accuracy, the contractor s identification, calibration interval, date calibrated, calibration procedure, source of calibration, measured values obtained in calibration and details of any repair, adjustment or maintenance. When measuring equipment and standards must be adjusted or reworked, the results of calibration before and after such work shall be included. Records shall be available for review, as required, by the ESCC Executive. 2.10 SEALING FOR INTEGRITY Access to adjustable devices which are fixed at the time of calibration shall be sealed or otherwise safeguarded to prevent tampering by unauthorised personnel. Seals shall be so designed that tampering will destroy them. 2.11 SUBCONTRACTOR CALIBRATION The contractor shall ensure that his subcontractors employ a calibration system which meets the requirements of this document. 2.12 STORAGE AND HANDLING A system shall be established and maintained for handling, transporting and storing all measuring equipment and standards that prevents abuse, misuse, damage or change in dimensional or functional characteristics.

PAGE 8 2.13 TECHNICAL MEASUREMENT EVALUATION The ESCC Executive has the right to conduct, at unscheduled intervals, a technical measurement evaluation for the purpose of determining that the techniques followed, and the personnel employed, in the contractor s calibration system demonstrate a continuing capability to make measurements of the required precision and to determine uncertainties associated with these measurements.