Airodyn, BRair and BRoil Compressed Air Drain Traps

Similar documents
MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

DF1 and DF2 Diffusers

TSS21 Sealed Thermostatic Steam Tracer Trap

AVC32 Carbon Steel Air Vent for Steam Systems

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Dri-Line Mk3 Monnier Compressed Air Drain Trap

DCV6 Disc Check Valve

AVM7 Stainless Steel Thermostatic Air Vent

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

PV4 and PV6 Piston Valves

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

TP1 and TP2 Temporary Cone Shaped Strainers

CA44, CA44S, CA46 and CA46S Air and Gas Traps

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

CVS10 Sanitary Check Valves

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

BPT13 Balanced Pressure Thermostatic Steam Traps

CP10 Sensor Installation and Maintenance Instructions

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

MF2M Monnier Miniature Compressed Air Filter

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

CA10S, CA14 and CA14S Air and Gas Traps

S and SF Inverted Bucket Steam Traps

APT14, APT14HC and APT14SHC Spares 2

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

CS10-1 Stainless Steel Clean Steam Separator

FV Flash Vessel Installation and Maintenance Instructions

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

ML3M Monnier Miniature Compressed Air Lubricator

Thermocirc Installation and Maintenance Instructions

BCV31 DN40 - Blowdown Control Valve

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

TW Temperature Control Valve

BDV1 and BDV2 Blowdown / Depressurisation Valves

SRV2S Pressure Reducing Valve

MFP14-PPU (Vented) Automatic Packaged Pump Units

Manual Actuated Boiler Blowdown Valves

PC10HP Pipeline Connector (ASME 600)

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

SRV66 Sanitary Pressure Reducing Valve

M70i ISO and M80i ISO Stainless Steel Ball Valves for Sanitary Systems Installation and Maintenance Instructions

Spirax Compact FREME Flash Recovery Energy Management Equipment

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

SCA Series Inverted Bucket Steam Traps

BRV71 and BRV73 Pressure Reducing Valves

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

BCV31 DN20 - Blowdown Control Valve

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

Vane Flow Switches Colima FLU Series

Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

QuickHeat TM Packaged Heat Exchanger Solutions

LP31 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance

PC3000, PC3001 and PC4000, PC4001 Pipeline Connectors

STERI-TROL Clean Service 'S' Series Two-port Control Valves DN15 (½") to DN100 (4")

M111 Spiraflo Transducer

BSA and BSAT Bellows Sealed Stop Valves Installation and Maintenance Instructions

BCVi43 Blowdown Control Valve

BDV60 Blowdown Vessel Installation and Maintenance Instructions

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

SRV461S and SRV463S Stainless Steel Direct Acting Pressure Reducing Valves

LP10-4 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance IM-P402-92

Colima TOR Magnetic Level Switches

Transcription:

6100550/3 IM-S48-06 ST Issue 3 Airodyn, BRair and BRoil Compressed Air Drain Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6. Maintenance 7. Spare parts IM-S48-06 Printed in the ST UK Issue 3 Copyright 2007 1

1. Safety information Safe operation of these products can only be guaranteed if they are properly installed, commissioned, used and maintained by qualified personnel (see Section 1.11) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. 1.1 Intended use Referring to the Installation and Maintenance Instructions, name-plate and Technical Information Sheet, check that the product is suitable for the intended use/application. The products listed below comply with the requirements of the European Pressure Equipment Directive 97/23/EC and carry the mark when so required. Product Group 1 Group 2 Group 1 Group 2 Gases Gases Liquids Liquids BRair SEP SEP SEP SEP BRoil SEP SEP SEP SEP Airodyn SEP SEP SEP SEP i) The products have been specifically designed for use on propane or methane gases which are in Group 1 of the above mentioned Pressure Equipment Directive. They can also be used on steam, air or condensate which are in Group 2 of the above mentioned Pressure Equipment Directive. The products use on other fluids may be possible but, if this is contemplated, Spirax Sarco should be contacted to confirm the suitability of the product for the application being considered. ii) Check material suitability, pressure and temperature and their maximum and minimum values. If the maximum operating limits of the product are lower than those of the system in which it is being fitted, or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence, ensure a safety device is included in the system to prevent such over-limit situations. iii) Determine the correct installation situation and direction of fluid flow. iv) Spirax Sarco products are not intended to withstand external stresses that may be induced by any system to which they are fitted. It is the responsibility of the installer to consider these stresses and take adequate precautions to minimise them. v) Remove protective covers from all connections and protective film from all name-plates, where appropriate, before installation on a steam or other high temperature applications. 1.2 Access Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting to work on the product. Arrange suitable lifting gear if required. 1.3 Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. 2 IM-S48-06 ST Issue 3

1.4 Hazardous liquids or gases in the pipeline Consider what is in the pipeline or what may have been in the pipeline at some previous time. Consider: flammable materials, substances hazardous to health, extremes of temperature. 1.5 Hazardous environment around the product Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery. 1.6 The system Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? Dangers might include isolation of vents or protective devices or the rendering ineffective of controls or alarms. Ensure isolation valves are turned on and off in a gradual way to avoid system shocks. 1.7 Pressure systems Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that the system has depressurised even when the pressure gauge indicates zero. 1.8 Temperature Allow time for temperature to normalise after isolation to avoid danger of burns. If parts made from Viton have been subjected to a temperature approaching 315 C (599 F) or higher, they may have decomposed and formed hydrofluoric acid. Avoid skin contact and inhalation of any fumes as the acid will cause deep skin burns and damage the respiratory system. 1.9 Tools and consumables Before starting work ensure that you have suitable tools and/or consumables available. Use only genuine Spirax Sarco replacement parts. 1.10 Protective clothing Consider whether you and/or others in the vicinity require any protective clothing to protect against the hazards of, for example, chemicals, high/low temperature, radiation, noise, falling objects, and dangers to eyes and face. 1.11 Permits to work All work must be carried out or be supervised by a suitably competent person. Installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal 'permit to work' system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post 'warning notices' if necessary. IM-S48-06 ST Issue 3 3

1.12 Handling Manual handling of large and/or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done. 1.13 Residual hazards In normal use the external surface of the product may be very hot. If used at the maximum permitted operating conditions the surface temperature of some products may reach temperatures of 200 C (392 F). Many products are not self-draining. Take due care when dismantling or removing the product from an installation (refer to Section 6 'Maintenance instructions'). 1.14 Freezing Provision must be made to protect products which are not self-draining against frost damage in environments where they may be exposed to temperatures below freezing point. 1.15 Disposal Unless otherwise stated in the Installation and Maintenance Instructions, this product is recyclable and no ecological hazard is anticipated with its disposal providing due care is taken. 1.15 Returning products Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to Spirax Sarco they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous. 4 IM-S48-06 ST Issue 3

2. General product information 2.1 General description Airodyn The Airodyn is a maintainable thermodynamic type compressed air drain trap. The external body surfaces have electroless nickel plated (ENP) which is oxidation resistant. Airodyn 'S' The Airodyn 'S' is also available with a fine lap disc for use on ultra clean systems where the standard Airodyn may not be suitable. BRair The BRair is a maintainable thermodynamic type compressed air drain trap, specifically for use on railway rolling stock (British Rail Cat. no. 61/41955). The external body surfaces have electroless nickel preparation (ENP) which is oxidation resistant. BRoil The BRoil is maintainable thermodynamic type compressed air drain trap, specifically designed to remove small quantities of oil contaminated condensate, for use on railway rolling stock. Standards These products fully comply with the requirements of the European Pressure Equipment Directive 97 /23 /EC. Certification These products are available with certification to EN 10204 3.1. Note: All certification/inspection requirements must be stated at the time of order placement. Note: For further information see the following Technical Information Sheets: Airodyn - TI-P610-05, BRair - TI-P610-03 and BRoil - TI-P610-10. 2.2 Sizes and pipe connections ½" screwed BSP or NPT. ¾" screwed NPT (Airodyn only). 2.3 Optional extras As an optional extra, a sliencer complete with elbow and reducer is available for the BRoil air trap only. Optional silencer Fig. 1 Airodyn / BRair air traps Fig. 2 BRoil air trap complete with optional silencer (British Rail Cat No. 15/07220) IM-S48-06 ST Issue 3 5

2.4 Pressure/temperature limits Temperature C Pressure bar g The product must not be used in this region. Body design conditions PN63 PMA Maximum allowable pressure 63 bar g @ 120 C (913.5 psi g @ 248 F) TMA Maximum allowable temperature 400 C @ 42 bar g (752 F @ 609 psi g) Minimum allowable temperature 0 C (32 F) PMO Maximum operating pressure 63 bar g @ 120 C (913.5 psi g @ 248 F) TMO Maximum operating temperature 400 C @ 42 bar g (752 F @ 609 psi g) Minimum operating temperature 0 C (32 F) PMOB Maximum backpressure should not exceed 80% of the inlet pressure under any conditions of operation otherwise the trap may not shut-off. PMN Minimum operating differential pressure for correct operation: 0.25 bar (3.6 psi) Designed for a maximum cold hydraulic test pressure of: 95 bar g (1377.5 psi g) 6 IM-S48-06 ST Issue 3

3. Installation Note: Before actioning any installation observe the 'Safety information' in Section 1. Refering to the Installation and Maintenance Instructions, name-plate and Technical Information Sheet, check that the product is suitable for the intended installation: 3.1 Check materials, pressure and temperature and their maximum values. If the maximum operating limit of the product is lower than that of the system in which it is being fitted, ensure that a safety device is included in the system to prevent overpressurisation. 3.2 Determine the correct installation situation and the direction of fluid flow. 3.3 Remove protective covers from all connections and protective film from all name-plates, where appropriate, before installation on steam or other high temperature applications. 3.4 Preferably fitted in a horizontal pipe but can be fitted in vertically downwards pipe. Note: If the trap is to discharge to atmosphere ensure it is to a safe place, the discharging fluid may be at a temperature of 100 C (212 F). 4. Commissioning After installation or maintenance ensure that the system is fully functioning. Carry out tests on any alarms or protective devices. 5. Operation One side of the disc (Figure 3) is plain with a single scratch towards the outer edge, whereas the other side of the disc has a machined circular groove. The trap is supplied with the grooved side of the disc towards the seating faces and is suitable for clean operating conditions. If the operating conditions are dirty, probably with heavy oil contamination, unscrew the cap, using preferably a ring spanner and turn over the disc so that the plain side with a bleed scratch is towards the seating faces. Replace the cap - no gasket is required but a suitable high temperature anti-sieze grease should be applied to the threads. Tighten the cap to the recommended torque (see Section 6). Do not use a wrench of the Stillson type which may distort the cap. In extremely dirty conditions it may be necessary to deepen the bleed scratch or to make additional scratches up to a maximum of 3. Note On ultra clean systems, an Airodyn 'S' with fine lap disc is required. The disc will be supplied without a single bleed scratch, but will have a groove machined in one side. The disc will also be supplied with grooved side of the disc on the seat. In ultra clean environments the disc may operate with a rapid cycling action that may not be acceptable. Turn the disc over so that the fine lapped face is now touching the seat. Fig. 3 Maximum of three bleed scratches The scratch should be over the area covered by and extending beyond the outer seat face. IM-S48-06 ST Issue 3 7

6. Maintenance Note: Before actioning any maintenance programme observe the 'Safety information' in Section 1. 6.1 How to service the Airodyn and BRair traps Unscrew the cap (2) using a spanner. Do not use Stillsons or a wrench of a similar type which may cause distortion to the cap. If the body seating faces are only slightly worn they can be refaced by lapping individually on a flat surface such as a surface plate. A figure of eight motion and a little grinding compound such as a Carborundum Co's compound I.F. gives the best results. If the wear is too great to be rectified by simple lapping, the seating faces on the body must be ground flat and then lapped. The disc (3) should always be replaced with a new one. The total amount of metal removed in this way should not exceed 0.25 mm. When reassembling, the disc is normally placed in position with the grooved side in contact with the body seating face (see Section 5, Operation). Screw on the cap. No gasket is required but a suitable high temperature anti-seize grease should be applied to the threads. 6.1.1 How to clean or replace the strainer Using a spanner unscrew the strainer cap (5), withdraw the screen (4) and clean it, or if damaged replace with a new one. To reassemble, insert the screen into the cap, then screw the cap into place. A fine smear of 'Molybdenum Disulphide' grease should be applied to the first few threads. Care should be taken to ensure that the gasket and gasket faces are clean. Tighten the cap to the recommended torque. 2 3 4 Withdrawal distance 85 mm (1 7 / 10") Fig. 4 Airodyn / BRair air traps Recommended tightening torques 6 5 Withdrawal distance 41 mm (3 4 / 10") Item No. Part or N m (lbf ft) mm 2 Cap 36 A/F 135-150 (99-110) 5 Strainer cap 32 A/ F M28 170-190 (125-140) 8 IM-S48-06 ST Issue 3

Note: Before actioning any maintenance programme observe the 'Safety information' in Section 1. 6.2 How to service the BRoil air trap Unscrew the cap (2) and remove the disc (3). Clean all internal ports and surfaces. Only clean groove 'A' with soft lint free cloth, do not use anything metallic. Replace the disc and cap (a fine smear of Molybdenum Disulphide grease should be applied to the threads) and tighten to the recommended torque. On test the unit should operate at a rate 180/220 cycles per minute on a 7 bar g (101.5 psi g) air system. 2 3 The silencer is an optional extra Groove 'A' 5 6 Fig. 5 BRoil air trap Recommended tightening torques Item No. Part N m (lbf ft) 2 Cap 36 A/F 135-150 (99-110) 5 24 A/F 30-40 (22-29) 6 11 A/F 5-8 (4-6) IM-S48-06 ST Issue 3 9

7. Spare parts The spare parts available are shown in solid outline. Parts drawn in broken line are not supplied as spares. Available spares Standard disc (packet of 3) 3 Airodyn and BRair Fine lap disc (Airodyn 'S') (packet of 3) 3 Strainer screen and gasket 4, 6 Strainer cap gasket (packet of 3) 6 BRoil Disc (packet of 3) 3 How to order spares Always order spares by using the desciption given in the column headed 'Available spares' and state the size and type of trap. Example 1: 1 - Strainer screen for a ½" Spirax Sarco Airodyn compressed air drain trap. Example 2: 1 - Packet of 3 discs for a ½" Spirax Sarco BRoil air trap screwed BSP. 3 3 Fig. 7 BRoil air trap 4 6 Fig. 6 Airodyn /BRair air trap 10 IM-S48-06 ST Issue 3

IM-S48-06 ST Issue 3 11

12 IM-S48-06 ST Issue 3