INSTALLATION INSTRUCTIONS

Similar documents
COUNTER CURRENT UNIT. Instruction Manual

Jet Swim Installation instruction

JET SWIM ELEGANCE 70 INSTALLATION AND USER GUIDE

ABRASIVE REGULATOR II

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Poollift Delphin. Version: February, 2015 MANUAL AND OPERATING INSTRUCTIONS

ABRASIVE REGULATOR II

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual

Air Intake Snorkel Kit

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

User Guide for. UTR Turbo Air Lappers Pneumatic Air Grinders & Lappers UTR-30, UTR-70, UR , ,

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

Installation, use and maintenance instructions. Gas burner (5)

Installation/Care/Use Manual

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

USE AND MAINTENANCE LIGHT TOWER

VK/VP SERIES : Sealless Vertical Pump. Assembling Instructions 2010

SHEER DESCENT & WATERFALL SPILLWAYS

Installation and Use Manual

Methylethycetone (MEC) - PMS 60 polyurethane glue - Grease - White silicone

Waterblade Installation Manual

TOOL ARMS with AUTOMATIC DOWN FORCE for LEVER-PERMIT AIR DRIVERS OWNER S MANUAL. This manual contains;

Vessel Installation and Operating Manual

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

VR46.5V(A)/VR86.5V(A) SERIES

Stand-N-Fish FULL DETAIL INSTALLATION INSTRUCTIONS

Dual fuel Gas-Oil/Gas burner

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Installation and commissioning instructions 255 series and 256 series

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

The X-11 Molding Chamber

ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 1 of 52 A-ARM, FLOOR PANEL, AND BUMPER ASSEMBLY

Step 1: Block sand the transom to remove the seam joint. The end result should be a flat transom without a ledge where the seam joint is.

STATIONARY SERIES 1/2 HP - 40 HP. UAB STELSA

ROUND ASSEMBLY. Positioning

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Installation Instructions

Installing ASI Umbilical Delivery Systems

INSTRUCTION MANUAL Kobelco Eagle Marine Water Lubricated Stern Tube Seals

LIQUID LEVEL GAUGE FOR WELDING ZGAU 716 O&M, 717 O&M, 718 O&M, 719 O&M

Operating instruction

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

IN-PLANT VALVES. Serving the Water & Waste Water Industry Since Clow Valve is a division of McWane, Inc.

Spare parts list ( ) Spare parts list high-pressure 9/20-4M *

TECHNICAL INFORMATION

DelVal Flow Controls Private limited

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Booster Pump PB4-60 Replacement Kits

Torque Specifications

INSTALLATION INSTRUCTIONS

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Air Differentail Pressure Switch

INSTALLATION INSTRUCTIONS

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

SIMPLAIR PIPING TOOL. JXT Company

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Technical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6

To Purchase This Item, Visit BMI Gaming (800)

830 SureFlo Soap Systems Installation Instructions. Foam Soap Cabinet... Pages 2-9 Liquid Soap Cabinet... Pages 10-19

Barcol-Air BRM Radiant Module

Armatures for analytical probes

Parts List. Description. Additional Considerations. Installation Instructions. Dual/Elite Hydraulic Treadmill Kit (supplied by EPI)

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515

Installation and Operating Manual

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

NAVIGATOR PROP BUILDING INSTRUCTIONS & PHOTOS

Series IRV1000/2000/3000

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

Spare parts list ( ) Spare parts list HD 2.3/14 C Ed Food

Installation Instructions

15ME-014 INSTRUCTION MANUAL OF STERN TUBE SEALING TYPE EVK2RV. URL

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

OPERATING INSTRUCTIONS Sherlock Chamber Testing System

Glove Box Installation Manual

Medical Gas Control Panel

1. Product Name. 2. Product Code. 3. Colour. 4. Brief Description. 5. Contents. Snoezelen Sensory Corner Kit. Cream Cushioned Platform

DM-MBRD (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike. Rear Derailleur SLX RD-M7000 DEORE RD-M6000

How To: Install a 1 Body Lift using Hockey Pucks A CFans Members Mod Project by grandmastrblastr

Operation Manual Air Saver Unit ASV5000 Series

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: RT

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

User's Manual. MixRite TF 10. Edition 05.08

Installation, Operation, and Maintenance Manual

Spare parts list ( ) Spare parts list HDS 700 B

200 / 300 Upgrade Kits

Float operated valve TYPE (SWDS)

MEDICAL GAS OUTLETS & PROBES

Spare parts list ( ) Spare parts list HD 1.8/13 C Ed

Type 4708 Supply Pressure Regulator

Transcription:

COUNTER-CURRENT SWIMMING Hurricane Turbo Swim Jet INSTALLATION INSTRUCTIONS PACKET NO.1 With a COUNTER-CURRENT SWIMMING device your swimming pool is no longer a simple man-made lake. It becomes the most appealing place to be, an amusement park, a place to have fun and become fit. A COUNTER-CURRENT SWIMMING device transforms your swimming pool into a water torrent and gives you general and localized hydrotherapeutic massages. The high-powered pump of the COUNTER-CURRENT SWIMMING device pumps up water from the pool and pushes the water back into the pool forcefully, together with millions of air bubbles which optimise your massages. 1

FIBREGLASS/VINYL CUT-OUT OF THE PANEL: Place the pattern on the inside panel taking the 400 mm linear dimension between the axis XY and the top of the structure into account. Caution: Make sure you position axis XY parallel to the top of the structure. Mark the 14 mounting bolt holes on the panel and cut out the pattern according to the points. Trace the profile on the panel and carry out the cutting and drilling. MOUNTING OF PACKAGE 1 ON THE PANEL: 1- Fitting of the 3 self-adhesive Gaskets: a) Clean the surface and then stick Gasket (4) to the Counter Flange (2). b) Clean and then stick Gasket (4) to the back of the Jet Body (1). c) Clean and then stick Gasket (4) to the flat side of the Flange. 2- Mounting of the Protective Shield: Mount the Protective Shield (5) using the 3 screws M5 which prevent any kind of deformation of the liner. 3-Mounting of the Jet Body: Hold the Counter Flange (2) to the outer side of the panel. Place the Jet Body (1) on the other side of the panel and keep everything in place by using the 2 fixing screws in A and B. 4-Fixing Bracket for Fibreglass/Vinyl Pools: After having placed the liner, fill the pool to the base of the Jet Body. Place the Bracket opposite the Jet Body and place the 12 screws (the liner is simply pierced by the screws). Tighten it enough for the joint to be well fixed into place but avoid using excessive force. If you are installing package 2 (= front) immediately, cut the liner with a cutter, otherwise leave in tact. 2

CONCRETE DRILLING: Position the pattern on the inside casing taking the 400 mm linear dimension between the axis XY and the top of the structure into account. CAUTION: Make sure you position axis XY parallel to the top of the structure. Pierce the 2 mounting bolt holes of 6 mm diameter in A and B. MOUNTING OF PACKAGE 1 ON THE JET BODY: 1. Placing of the self-adhesive Gasket: Clean the pre-drilled side of the Counter Flange (2) then stick Gasket (4) to Counter Flange. 2. Mounting of the Jet Body: Place the Counter Flange (2) at the rear of the Jet Body (1) and fix the whole device to the inside casing by using the 2 fixation screws A and B. Make sure the outer casing is fixed to the sleeves so that the concrete cannot enter. If this is not the case, use a piece of polystyrene to fill the gap. CAUTION: Fix the air intake pipe against the wall of the premises, above water level, by using the hook provided for said purpose. 3

LOCATION OF THE PRESSURE REGULATOR: If your electrical equipment box is more than 5 metres away from the front face, you should bring the pressure regulator (interrupter of the pneumatic button) close to the swimming pool in a connection box. POSITIONING OF THE PUMP: The pump of this device must be installed next to the structure and must be connected by a pressure pipe, minimum diameter 50mm. If this is not possible the pump can be placed further away, although the loss of pressure/flow must be calculated for. Refer Table below. Distance between the front face and the pump Diameter of the pipes 1m Diameter 50mm (2 ) 1 to 5 m Diameter 65mm (2.5 ) 5 to 15 m Diameter 80mm (3 ) Additional components: Ergonomic Jet Face. Adjustable Air Outlet Valve. Pneumatic Start-Up Control. PACKAGE NO.2 PACKAGE NO.3 Single-phase or Three-phase Hydro-Electric Generating Set. PACKAGE NO.4 Single-phase or Three-phase Switch Box (with Thermal Relay adapted in accordance to the choice of Hydro-Electric Generating Set). 4

Hurricane Turbo Swim Jet INSTALLATION INSTRUCTIONS PACKET NO.2 With the HURRICANE TURBO SWIM JET your swimming pool is no longer a simple man-made lake. It becomes the most appealing place to be, an amusement park, a place to have fun and become fit. The SWIM JET transforms your swimming pool into a water torrent and gives you general and localized hydrotherapeutic massages, as well making counter-current swimming possible. The high-powered pump of the SWIM JET pumps up water from the pool and pushes the water back into the pool forcefully, at the same time as millions of air bubbles are propelled by the JET, bringing you power, oxygen and tonification. 5

MOUNTING OF PACKAGES 2, 3, 4 - Make sure the 12 screws of the flange are correctly fastened without using excessive force. - Cut out the liner along the inside of the flange by using a cutter. - Remove the protective shield attached to the Jet Body with three M5 screws length 10. CONNECTING: -Connect the small capillary tube to the back of the Control Button, and pass it under the air intake pipe, then through the slit foreseen for this purpose on the Air Regulation Button. -Now slide capillary tube through reinforced hose connected to Jet Body. CAUTION: the far end of the air intake pipe must be placed above water level. -Do not forget to place the blue tube filter at the far end of the air intake pipe. -Fix the air intake pipe to the wall of the premises using hook provided. FIXING JET FACE: -Once all previous instructions have been carried out, screw the Jet Face to the Jet Body by using three fixation screws M5 length 30. 6

CONNECTION TO THE SWITCH BOX POSITIONING OF THE PRESSURE REGULATOR: If your electrical equipment box is more than 5 metres away from the Jet Face, the Pressure Regulator (interrupter of the pneumatic button) should be moved closer to the swimming pool in a connection box. WINTER STORAGE: (Only required in countries with temperatures below 0 degrees Celcius) -Disconnect the capillary tube from the switch box. -Dismantle the Jet Face and remove the whole device. -Place the two tapered stoppers in the two openings of the Jet Body. -Turn thumb screw until stopper has expanded adequately to ensure seal is watertight 7

Swim Jet -The push-button is used to turn on the device by applying light pressure to the button. -The other button is used to regulate the output of air from the valve, allowing more or less air to be propelled from the valve. -CAUTION: Do not forget to close this air button after having used the massage pipe which is fitted on the valve (optional accessory). REGULATING THE VALVE: You can regulate the direction of your jet as well as the output of air from the valve by simply turning the valve one quarter. Basic Components: (to be foreseen at the time of construction) Additional Components: Optional Accessories: Jet Body Flange and Counter Flange with Gaskets Shut-Off Valves Air Intake Ergonomic Jet Face Adjustable Air Output Valve Pneumatic Start-Up Control Switch Box Massage Pipe 8