EN00 Pre-Instructional Survey

Similar documents
Gerald D. Anderson. Education Technical Specialist

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

Engineering Information. Flow Data. Flow Data. Importance of Valve Sizing. Estimating Cv or Orifice Size:

PROCESS MONITORING AND CONTROL

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

Application Worksheet

SINGLE VALVE WITH LOW-FLOW BYPASS

EXPERIMENT 2 LEVEL CONTROL SYSTEM

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover

Quick Reference Technical Data

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

780S Ultra High Purity Series

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

For Multi-Parameter Meters see mvx

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

SIZING AND CAPACITIES OF GAS PIPING

For Multi-Parameter Meters see mvx

Features. Description

Pressure Control. where: p is the pressure F is the normal component of the force A is the area

2007 Gas-Lift Workshop

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

3.0 Pressure Transmitter Selection

How to specify a product. Process Sensors and Mechanical Instruments

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

North American Orifice Metering System

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

IE073: Intrinsic Safety, Galvanic Isolation and Zener Barriers Technology & Applications

VBS-9263 Series. Application. Features. Applicable Literature

SIZING AND CAPACITIES OF GAS PIPING

Introduction to Pressure Measurement

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Ultra High Purity Model 780S

VB-7263 Series. Application. Features. Applicable Literature

PRO-50 Instrument Supply Regulator

Bubble Tube Installations

Best Practices for Installation of Gaseous Sample Pumps

American made since 1954

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

T EK-COR 1100A Coriolis Mass Flowmeter

VB-7273 Series. Application. Features. Applicable Literature

Best Practice Guide, Servomex 2700

SPD Pressure Sensor Families

Noth American 7347 High Pressure Gas Regulators

Pressure transmitters EMP 2

RCD - Ultra-Rugged Differential Pressure Flowmeter

DPC-30 DPC-100. Reference Manual

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Intrinsically Safe Acoustic Instrument Used in Troubleshooting Gas Lift Wells

Dry Plant Measurement Information

Process Equipment Design Guidelines Chapter Four Instrumentation Selection and Sizing (Engineering Design Guidelines)

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

Process Control Loops

InstrumentationTools.com

TOPIC: KNOWLEDGE: K1.01 [2.5/2.7] An atmospheric pressure of 15.0 psia is equivalent to... A psig. B psig. C psig.

Miniature Pressure Sensors

SIZING AND CAPACITIES OF GAS PIPING Reserved

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

SDX Submersible Depth Transmitter User Manual

Valve Proving System VDK 200 A S06*

SIZING AND CAPACITIES OF GAS PIPING

Modeling Case Study: Surge Tanks, Valves, Level sensors, and modeling

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

SB AXIAL FLOW VALVES

AUTOMATIC DREDGING PROFILE AND CONTOUR CONTROL

TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

BUBBLER CONTROL SYSTEM

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

Instrumentation. Introduction to Instrumentation. Revised 11/30/18 1

North American 7339 High Pressure Gas Regulators

Rosemount Integral Orifice Flow Meter Series. Reference Manual , Rev KA December 2017

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Pro-V Multivariable Flowmeter

TurboDraft Fire Eductor

Pressure and Temperature Controls

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

IPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

The Hoffman Specialty Series 2000 consists of main

FOAM TANK (1/2) DATA SHEET

CASH VALVE TYPE KP BACK PRESSURE VALVES

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Instrumentation & Data Acquisition Systems

Valve Proving System VDK 200 A S02

7Flat-Trak Model 780S. Smart In-Line Thermal Gas Mass Flow Meter with Flow Conditioner. For information online...

Design Change Notification

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

Automatic Valve Proving Control

Transcription:

EN00 Pre-Instructional Survey Name: Date: 1. At 433 degrees F, a type J thermocouple with a 3 degree F reference junction will produce an output in millivolts that is most nearly to: a. 9.04 b. 10.51 c. 1.05 d. 17.79. The flow of water in a 6-inch pipe is measured with an orifice plate and differential pressure transmitter. At a flow rate of 00 GPM, the differential pressure is 35 inches of water. At a flow rate of 31 GPM, the differential pressure will be approximately equal to: a. 16.4 wc b. 3.5 wc c. 85.4 wc d. 100 wc 3. A tank level is measured using a differential pressure transmitter and a bubbler tube. The tank is vented to atmosphere. The bubbler tube is 1 foot from the bottom of the tank and the tank wall is 0 feet high. A 0-10 psig differential pressure gauge, accurate to.5 per cent of full scale is connected to the bubbler tube connection at the high side of the transmitter. The low pressure side is connected to the tank top. With the tank containing liquid with a specific gravity of 1.1 and the level in the tank at 16 feet, the gauge reading in pounds per square inch (psi) is most nearly equal to: a. 4.8 b. 9.35 c. 13 d. 7.1 4. Which of the following practices is important in routing optic cable? a. Laying cable in trays with high-horsepower motor wiring should be avoided. b. onduit fittings that require small radius bends should be avoided. c. Overhead runs on messenger wires should be limited to 75 feet. d. Underground fiber optic runs must be covered with concrete. 015, ISA 1

5. ompared to a control loop with no dead time (pure time delay), a control loop with an appreciable dead time tends to require: a. Less proportional gain and less integral action b. More proportional gain and less integral action c. More proportional gain and more integral action d. Less proportional gain and more integral action 6. The definition and classification of hazardous areas for the purpose of wiring and electrical equipment is found in codes published by: a. National Fire Protection Association b. ISA-The Instrumentation, Systems and Automation Society c. Electric Power Research Institute d. Occupational Safety and Health Administration 7. Given the following data for liquid flow: Flow rate 0 to 00 gpm Water at 15 degrees F and 75 psia Pipe Size 4 inch schedule 40 The orifice bore for a pressure differential range of 100 inches of water is most nearly equal to: a..33 inches b. 3.5 inches c. 1.5 inches d..75 inches 8. A control valve is to be sized for the following conditions: Liquid flow, 50 GPM, specific gravity.81, inlet pressure of 40 psig, with a pressure drop of 10 psi. The required flow coefficient for the valve will most nearly be: a. 10.4 b. 14. c. d. 35.5 015, ISA

9. A control valve is to be sized for the following conditions: Saturated steam at a maximum flow rate of 30,000 pounds per hour and an upstream pressure of 40 psia. P will be 30 psia according to the flow sheet and physical piping arrangement. The required flow coefficient for the valve will most nearly be: a. 60 b. 540 c. 760 d. 198 10. The control algorithm for a flow control loop is under consideration. It is determined that the flow must be maintained near set point with little or no offset and the signal will be rapid response and noisy. The best choice of control modes for this loop will be: a. Proportional Mode b. Integral plus Derivative c. Proportional plus Integral d. Proportional plus Integral plus Derivative 11. According to ISA Standard S5.1, Instrumentation Symbols and Identification, the terms record or recording can apply to which of the following: I. Graphical data in a strip or circular chart II. A table of numerical data in a computer memory III. A listing of alarms by a control computer a. I and II b. II and III c. I and III d. I, II, and III 1. An orifice plate is to be used to measure the flow of water in a 4 inch, schedule 40 line. The flow rate is specified as 0 00 GPM at a pressure of 75 psia and a temperature of 15 degrees F. If a differential pressure of 100 inches of water is used for the primary element, the orifice bore will most nearly equal to: a. 3.5 inches b. 1.4 inches c..3 inches d. 0.9 inches 015, ISA 3

13. A SIL 1 interlock has an RRF of 4.76. The target RRF is 75. How can you increase the RRF to meet or exceed the target RRF? a. Add more field sensors. b. Add dual solenoids to the one and only one block valve c. Double the testing frequency d. None of the above. 14. Which of the following types of valves has the highest gain when the valve is nearly closed? a. Quick opening b. Equal percentage c. Fail open d. Linear 15. Which of the following types of control systems is normally programmed in ladder logic? a. Programmable logic controllers (PLs) b. Distributed control systems (DSs) c. Single loop digital controllers d. Supervisory ontrol and Data Acquisition (SADA) 16. What is the resistance of 000 feet of copper wire (specific resistance 10.37) given a cross sectional area of 0370 cmil and a wire temperature of 0 degrees? a. 1 b. c. 10 d. 0 17. Which of the following protection techniques is acceptable for equipment located in a lass I, Division 1 area of an industrial facility? a. Explosion- proof apparatus and nonincendive equipment b. Explosion-proof apparatus and intrinsically safe equipment c. Dust ignition proof and nonincendive equipment d. General purpose and intrinsically safe equipment 015, ISA 4

18. To minimize electrical interference when A power and D signal wiring meet in a control panel, it is BEST to: a. Use a different size wire b. ross the wires at 90 degrees c. Run the wires parallel to each other d. Twist the A wires around the D wires 015, ISA 5

EN00 Pre-Instructional Survey Answers 1. Type J Thermocouple Table w/ 3 F Reference. The emf @ 430 11.96 m @ 440 1.6 m 3 Interpolating: 11.96 + ( ) (1.6-11.96) 1.05 m Answer is 10 1.05 m. F 1 P 00 1 35 F P 31 X X 35 00 31 35.41 85.4" H O Answer is 85.4" H O 3. A P LT P 15 ft x 1.1 16.5 ft H O 0' G 1.1 16' P 16.5 ft.433 PSI ft P 7.14 PSI 1' Answer is D 7.1 PSI 4. Small radius bends 5. Open Loop Tuning Parameter K.9 KT P d T Derivative Time D T (Dead Time) T 3.33 T (Minutes/Repeat) d D d Smaller gain and less integral action 6. NFPA produce NE Q 7. K [(19.636)(Fa)()] h 4 d K K 1 + D 4 (00) K [19.636(1.0)(.61)] (8.33 ft) 40,000 K 143.5 (8.33) 33.5 4 33.5 d 1 + d.33" 33.5 (4.06) 4.33 copyright 005 ISA 015 ISA 1

EN00 Pre-Instructional Survey Answers 8. Q 50 14.3 G F P.81 10 P ALLOW F L (P 1 - FFP ) F F.96 -.8 14. P P 9. W X P F 1 X P P 1 10.5 40 560 540 30,000 W (1 +.007 T SH) P (P1 + P) 10 (40 + 30).5(40)(.095) 30,000 X T.85 F L.85 (.85) X T.6 Y 1 - Y 1 - Y.87 X 3X T.5 3(.6).095lb ft 3 540 10. Noisy signal eliminates derivative need. To get to set point, integral is needed. Answer is Proportioned plus Integral 11. Record or Recording indicates any history of a quantity. Answer is D I, II, and III 1. Same as #7 omputer Run: B.587 d.36" S 5.667 D Q m G b G F hm SPINK S S 00(1.0) 5.667 (4.06).98 00 90.67 (.99) (10) 100 S.3 and B 585 d BD.585(4.06) d.33" Answer is.33" copyright 005 ISA 015 ISA

EN00 Pre-Instructional Survey Answers 13. RRF 4.76 need RRF 75 RRF LAMBDAd * T1 Doubling the testing frequency, T1, will yield a RRF of 85.5 Answer is Double the testing frequency 14. The Quick opening characteristic will give more flow initially as the valve starts to open. 100 Flow Opening 100 15. Programmable Logic ontrollers are programmed using ladder logic for discrete control. rl 16. R A ross sectional area (Mil) 10.37 (000) R R OHMS r Specific resistance L Length 17. lass I, Division is gas product which may be present at all times. Therefore, explosion proof or intrinsically safe devices must be used. 18. If the wires are crossed at 90 degrees the emf interference will tend to cancel each other. 015 ISA 3