HOSPITAL STRUCTURAL PRODUCTS 12. MEDICAL GAS SYSTEMS LUMINAIRES AND OTHER EQUIPMENTS WALL CORNER PROTECTION SYSTEMS A. B. C.

Similar documents
OXYGEN THERAPY FLOWMETERS, REUSABLE AND SINGLE-PATIENT HUMIDIFIERS, PRESSURE REGULATORS, FLOW SELECTORS

Respiration Equipment Flowmeters 06 Regulators 09 Venturi System Suction Units 11. Suction Accessories Reusable Canister 12 Central Vacuum System 14

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

MEDICAL GAS SYSTEM & EQUIPMENT

BY GREGGERSEN CATA LOG

PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES

FLOWMETER UNITS FLOWMETER DEVICES, BY-PASS SYSTEMS

MEDAP-MOBILE GAS SUPPLY

erc-o 2 -tech Ò innovative gas systems Markwerbener Str Weißenfels Germany

MEDICAL GAS OUTLETS & PROBES

Technical Datasheet. Rigid & Retractable Pendants. Rigid Pendant

Type 4708 Supply Pressure Regulator

SUPPLY, DESIGN, ERECTION & COMMISIONING OF COMPLETE MEDICAL GAS PIPE LINE SYSTEM BOQ (NSR)

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

[Instruments for vacuum measurement, checking and adjustment] 3

MEDAP-FLOWMETERS FOR OXYGEN AND COMPRESSED AIR

Glass tube flowmeters Series 2000

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Perfect Medical Product

Type 4708 Supply Pressure Regulator

Technical Specification

4/2 way Pneumatic Solenoid Valve

Instructions for use Compressed air injector with water trap

GENERAL CATALOGUE 2O16

American Medical Gas Outlets

ScanFoam. Cleaning Equipment ApS. w w w. s c a n f o a m. c o m

REGULATORS FLOWMETERS HUMIDIFIERS. Professional GAUGES ASSESSORIES. Medical Apparatus. and Assessories ISO 13485/ISO 9001 CERTIFICATION

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

ALF400 to 900, ALT-5/-9

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Optimum oxygen supply for your patients! ATMOS Oxygen Supply

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

O NEof Premium tools for professionals!

300 Held Drive Northampton Pa

Pneumatic spool valve islands

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

B74G - EXCELON Modular System General purpose filter/regulator

tel: fax: web:

Measurement of Low GAS & Liquid Flows

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

CONTROLLERS FOR COMPRESSED AIR AND VACUUM MEDAP-FINA SUCTION

Order No Projection Backboard

VACUUM REGULATORS CONTENTS

Digital Tourniquets. Product Details. For electricity VAC, 50/60 Hz

MEDICAL CYLINDER VALVES

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Direct Operated Precision Regulator Modular Style. Standard Specifications

Type 4708 Supply Pressure Regulator

B84G - Excelon Plus Modular System General purpose filter/regulator

Manifolds & pressure reducing sets

SPECIFICATIONS ATTENTION

D Quality and Precision you can Trust in Oxygen Administration CONVENTIONAL FLOWMETER DIGITAL FLOWMETER COMPACT FLOWMETER

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

PRO SINK -R 1 and 2. Dilution system CONTENTS

10.2. Basketball Single Post System

TITAN Oxygen Regulators

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

PRESSURE CONTROL REGULATORS

Oxygen Dialflow Meter. Instructions for Use

Oxygen Dialflow Meter. Instructions for Use

Additel 780 Series Pressure Controller

I. Subject: Compressed gas cylinders, regulators, and portable liquid systems.

Compact medical oxygen generator for : J Anaesthesia machines / OTs J Recovery ventilators / ICUs J Oxygenotherapy J Cylinder filling systems

10.2. Basketball Single Post System

Precision and Instrument Regulators 1/4" port size

AUTOMATIC HOSE TEST UNIT, TYPE SPU

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

Damao Range. Single & Double Line Pressure Regulator - 4 or 8 bar

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Full-Vacuum Chlorinator C 2212 MB / 1

Series IRV1000/2000/3000

[Graphic Division] 10

Specification for Medical Gas Pipeline s

ila ACTIVVE SYSTEM PLATFORM

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

RR 16 Commercial & Industrial Regulator

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

Valve with Integrated Pressure Regulator for medical OXYgen

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Expert Hydrostatic Level Transmitters

B84G - Excelon Plus Modular System General purpose filter/regulator

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

5 Channel Calibrator

Booster Regulator/Air Tank

With or without proof of conformity.

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

suction and oxygen therapy

The CompacSas BAH airlock is the ideal solution for transforming an existing door into an airlock

Compressed Airline Breathing Apparatus

Air service units series K G1/8, G1/4

Flow meter. bellow vaporizer. APL valve. Scavenging system

Series K Air service units G 1/8, G 1/4

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

VACCUPERM Vacuum chlorine gas dosing systems

Transcription:

244 // HOSPITAILOR

12. HOSPITAL STRUCTURAL PRODUCTS MEDICAL GAS SYSTEMS LUMINAIRES AND OTHER EQUIPMENTS WALL CORNER PROTECTION SYSTEMS A. B. C. HOSPITAILOR // 245

A. MEDICAL GAS SYSTEMS PATIENT BED HEAD UNIT WITH TRIPLE CHANNEL DOUBLE LAMP ARTICLE CODE 551.1001 Extruded Aluminum Material RAL colors are avaliable 220V AC - 50 Hz power input Standard Accessories Electrical Socket: 3 pcs EUR/UK/USA Reading Lamp: 1 pc, LED General lighting lamp: 1 pc, LED Commutator 1 pc Flowmetre 1 pc Regulator 1 pc Water pen 1 pc Vacuum jar 1 pc Oxygen Outlet- Vac Outlet 1 pc Dimension: Width: 82.2 x Length: 245 mm PATIENT BED HEAD UNIT WITH DOUBLE CHANNEL AND SINGLE LAMP ARTICLE CODE 551.1002 Extruded aluminum material with electrostatic paint RAL colors are avaliable 220 VAC - 50 Hz power input Standard Accessories Electrical Socket: 3 pcs EUR/UK/USA Reading Lamp: 1 pc, LED General lighting lamp: 1 pc, LED Commutator 1 pc (25 x 10 mm) Flowmetre 1 pc Regulator 1 pc Water pen 1 pc Vacuum jar 1 pc Oxygen Outlet- Vac Outlet 1 pc Dimension: Width: 110 x Length: 280 mm 246 // HOSPITAILOR

HOSPITAL STRUCTURAL PRODUCTS PATIENT BED HEAD UNIT WITH THREE CHANNELS AND DOUBLE LAMPS ARTICLE CODE 551.1003 Extruded aluminum material with electrostatic paint accessory rail is aluminum Eloxal colour 220 VAC - 50 Hz power input Wall type and ceiling type are avaliable upon request Standard Accessories Electrical Socket: 3 pcs BS/DIN/NF Grounding: 3 pcs Accessory rail: 2 pc, (25x10 mm) Flowmetre 1 pc Regulator 1 pc Water pen 1 pc Vacuum jar 1 pc Oxygen Outlet- Vac Outlet 1 pc Dimension: 260x1550x10 mm CHANNEL AND DOUBLE RAIL ARTICLE CODE 551.1004 Extruded aluminum material with electrostatic paint accessory rail is aluminum Eloxal colour 220 VAC - 50 Hz power input Wall type and ceiling type are avaliable upon request Standard Accessories Electrical Socket: 12 pcs EUR/UK/USA Grounding: 8 pcs Accessory rail: 2 pc, (25x10 mm) Flowmetre 1 pc Regulator 1 pc Water pen 1 pc Vacuum jar 1 pc Probe 1 pc Oxygen Outlet- Vac Outlet Air Outlet, NO2 Outlet 1 pc Dimension: Width: 110 x Length: 280 m HOSPITAILOR // 247

A. MEDICAL GAS SYSTEMS PENDANT WITH MONITOR SHELF ARTICLE CODE 551.1005 SINGLE JOINT PENDANT WITH DOUBLE SHELF ARTICLE CODE 551.1006 PENDANT WITH HORIZONTAL AND VERTICAL MOVEMENT, ONE SHELF ARTICLE CODE 551.1007 80 kg carrying capacity In accordance to different iternational standards medical gas and electric sockets Products are with ground node Optional Accessories: Shelve, IV Pole, Drawer, Data socket (RJ45), Manometer for Medical Gases, Medical gas outlets (BS, DIN, NF) (551.1005) Body made of aluminum, moving arm steel profile, rack 1mm steel, hood made of plastic (551.1005) Manual movement around its own axis movement Standard Accessories: Power Outlet: 8 UK, USA, Europe, Grounding Note: 8 Rail Shelf: 1 Piece (551.1006) Body made of aluminum, moving arm steel profile, rack 1mm steel, hood and joint closure made of plastic Horizontal and around its own axis movement Standard Accessories: Power Outlet: 16 number UK, USA, Europe, Grounding Note: 16 Pieces Rail Shelf: 2 Pieces (495 x 465 mm) (551.1006) (551.1007) Body made of aluminum, moving arm steel profile, rack 1mm steel, hood and joint closure made of plastic Motorized vertical movement, manually horizontal movement around its own axis movement Standard Accessories: Power Outlet: 8 UK, USA, Europe, Grounding Note: 8 Rail Shelf: 1 Unit (495x465mm) (551.1007) 248 // HOSPITAILOR

HOSPITAL STRUCTURAL PRODUCTS MEDICAL GAS OUTLETS ARTICLE CODE 551.1008 / 551.1009 / 551.1010 (BS Medical Gas Outlets) Head Diameter: 50 mm Copper Pipe Diameter: 10 mm Production Standard: BS 5682 / EN ISO 9170-1 Color Code: Oxygen (white), vacuum (yellow), nitrous oxide (blue), compressed air (4/7) (black / white) 551.1008 (DIN Gas Outlets) Head Diameter: 45 mm Copper Pipe Diameter: 10 mm Production Standards: DIN 13260-2 / EN 737-1 Color Code: Oxygen (white), vacuum (yellow), nitrous oxide (blue), compressed Air (4/7) (black / white) 551.1009 (AFNOR Gas Outlets) Head Diameter: 40 mm Copper Pipe Diameter: 10 mm Production Standard: NF S 90-116 Color Code: Oxygen (white), vacuum (yellow), nitrous oxide (blue), compressed Air (4/7) (black / white) 551.1010 MEDICAL GAS OUTLET BOXES ARTICLE CODE 551.1011 / 551.1012 Base, body, and according to user preference BS and DIN norms cover consisting Plastics products are manufactured in different sizes HOSPITAILOR // 249

A. MEDICAL GAS SYSTEMS MEDICAL GAS OUTLET BOXES ARTICLE CODE 551.1013 Body and cover consisting of AFNOR norms Body material, plastic cover section manufactured from aluminum in different sizes RESPIRATION EQUIPMENTS REGULATORS ARTICLE CODE 551.1014 (Oxygen), 551.1015 (Nitrous Oxide), 551.1016 (Vacuum), 551.1017 (Medical Air 4), 551.1018 (Medical Air 7) Chrome plated brass trunk Flow adjustment knob Pressure or vacuum gauge Gas specific connection port Suitable outlet for hose connection VENTURY TYPE VACUUM REGULATOR ARTICLE CODE 551.1019 / 551.1020 / 551.1021 Designed to provide vacuum by using compressed air or oxygen source Chrome coated brass trunk 551.1019 : BS 551.1020 : AFNOR 551.1021 : DIN VACUUM REGULATOR, THREE STAGE ARTICLE CODE 551.1022 / 551.1023 / 551.1024 Vacuum ranging between 0-760 / 0-400 mmhg Ability to choose low, medium and high vacuum power Integrated protective float in the jar to prevent overflow of liquid waste Indicator of color coded products Low Vacuum: 0-80 mmhg, Yellow Medium Vacuum: 80-200 mmhg, Orange High Vacuum: 200-400 mmhg, Red 250 // HOSPITAILOR

HOSPITAL STRUCTURAL PRODUCTS VACUUM REGULATOR ARTICLE CODE 557.1001 / 557.1002 Vacuum outlet G. 1/2 threaded connection integrated with quick-release connection for 557.1007 safety jar De-pressure excess safety valve (for 557.1001 only) with anti-clogging system Quick I/0 push switch-button, to stop the suction Maximum supply depression; -950 mbar Suction adjusting system; with membrane Standard vacuum supply connection; ISO G. 1/4 M 557.1001 557.1002 Dimension 92x103x170 mm 92x103x170 mm Weight 0.42 Kg 0.37 Kg Maximum suction rate 50 L/min. ±5 L/min. at -220 mbar 115 L/min. ±5 L/min. at -950 mbar Maximum adjustable depression -220 mbar ±20 mbar -950 mbar Valve protecting against excessive negative pressures Preset with anti-clogging system N/A VACUUM REGULATOR ARTICLE CODE 557.1003 / 557.1004 / 557.1005 Vacuum gauge with colored sectors scale, for easy reading of set vacuum values Silicon cover and anti shock support Quick I/0 push switch-button ISO G. 1/2 M. + quick release system for 557.1006 safety jar connection only Adjustment assembly quick release cover 1/12 turn De-pressure excess safety valve (for 557.1003 and 557.1004 only) with anticlogging system Vacuum setting knob with Push&Lock system and Soft Grip inserts for easy handling Maximum depression supply value; -950 mbar Suction value adjustment system; with membrane Standard inlet connection; ISO G. 1/4 M 557.1003 557.1004 557.1005 Dimension 106x 91x185 mm 106x 91x185 mm 106x 91x185 mm Weight 0.470 Kg 0.370 Kg 0.370 Kg Maximum suction flow Maximum available negative pressure effective value 50 L/min. ±5 L/min. at -220 mbar 72 L/min. ±5 L/min. at -550 mbar 115 L/min. ±5 L/min. at -950 mbar -220 mbar ±20 mbar -550 mbar ±20 mbar -950 mbar Over depression protecting valve preset with anti-clogging system preset with anti-clogging system N/A Vacuum gauge 0-250 mbar 0-600 mbar 0-1000 mbar HOSPITAILOR // 251

A. MEDICAL GAS SYSTEMS SAFETY JAR ARTICLE CODE 557.1006 Quick release snap ring for 557.1003, 557.1004, 557.1005 and 557.1010 vacuum regulators connection. Presence of Soft Grip inserts to help the handling By quick 1/12 turn to speed up the jar cleaning and the antibacterial filter replacement (if filter present) 360 rolling positioning hose connector Ø = 8.0 9.2 mm Housing for placing an (optional) antibacterial filter Overflow system; floating valve Maximum applicable vacuum value; -950 mbar / 5 min. Dimension: 76x93x74 mm Weight: 0.120 Kg SAFETY JAR ARTICLE CODE 557.1007 Housing for antibacterial filter Ø 50 mm (filter not included) Quick release lock-unlock nut system Suction source connection; quick release connection to 557.1001, 557.1002 vacuum regulator Patient connection; hose connector Ø 8.0 9.2 mm Maximum applicable vacuum value; -950 mbar / 5 min. Maximum flow value; 60 L/min. ±10 L/min. at -950 mbar (without antibacterial filter) Dimension: 90x70x75 mm Weight: 0.08 Kg 252 // HOSPITAILOR

HOSPITAL STRUCTURAL PRODUCTS VENTURI SUCTION UNITS ARTICLE CODE 557.1008 / 557.1009 The adjusting knob allows the suction value setting in a stable and accurate way A quick I/0 button switch is available on 557.1009 Venturi unit for immediate suction activation or deactivation On 557.1009 unit a high performance silencer reduces the noise giving comfort to the patient and health operators during the use Gas and supply pressure (standard version); compressed air 400 kpa (4.0 bar) ± 10% Adjustment of suction level; needle valve Air consumption at the max. Suction value; 60 L/min. ±2 L/min. Inlet connection; ISO G. 1/4 M., Outlet connection to the patient; ISO G. 1/2 M. 557.1008 557.1009 Dimension (without collection jar) 70x88x92 mm 80x140x140 mm Weight (without collection jar) 0.80 Kg 0.95 Kg Max. suction range 25 L/min. ±2 L/min. 27 L/min. ±2 L/min. Vacuum gauge scale 0-1000 mbar 0-1 bar Maximum adjustable depression (with plate pressure ±10%) -800 mbar -25 mbar -0.85 bar ± 0.025 bar VENTURI SYSTEM SUCTION UNITS ARTICLE CODE 557.1010 Quick release system for 557.1006 safety jar connection only I/0 push switch button Vacuum gauge with colored sectors scale, for easy reading of set vacuum values Vacuum setting knob with Push&Lock system and Soft Grip inserts for easy handling Gas and supplied pressure; compressed air 400 kpa (4.0 bar) ±10% Standard inlet connections; ISO G. 1/4 M. 1/4 NPT M. Standard outlet connection; ISO G. 1/2 M. Maximum suction flow; 27 L/min. ±2 L/min. at -775 mbar Vacuum gauge; 0-1000 mbar Maximum adjustable depression (with plate pressure ±10%);-800 mbar -25 mbar Safety valve against back pressure excess; N/D Air consumption at the maximum suction value; 60 L/min. ±2 L/min. Dimension: 123x89x141 mm Weight: 0.570 Kg HOSPITAILOR // 253

A. MEDICAL GAS SYSTEMS COLLECTION CONTAINERS FOR SMALL QUANTITY OF FLUIDS ARTICLE CODE 557.1011 557.1012 Supply depression; max -950 mbar - 5 min. Overflow valve; floating valve, Inlet connection; ISO G 1/2 F. Outlet connection; hose connector Ø 8.0 9.2 mm 557.1011 557.1012 Dimension 98x70x215 mm 98x70x245 mm Weight 0.21 Kg 0.25 Kg OXYGEN THERAPY DEVICE ARTICLE CODE 551.1025 Appropriate to use in hospitals and emergency services Suitable for homecare usage, Chrome plated brass trunk Designed to adjust and control the oxygen flow 0 15 lpm standard scaling markings High resisting polycarbonate humidifier bottle suitable for sterilisation Regulator Inlet Pressure: 200 kg / cm² Regulator Outlet Pressure: 3,5 ~ 4 kg / cm² Adjustable Flow: 0-15 L / min Pressure Gauge Range: 0-315 kg / cm2 Sterilisation method: 121 C (autoclave) OXYGEN THERAPY HUMIDIFIERS ARTICLE CODE 557.1013 / 557.1014 / 557.1015 Detail of the bottle graphics, Detail of the cover Detail of the bubble device Max. applicable pressure value; 500 kpa Max. applicable flow value; 10 L/min. Inlet connection; 1/4 ISO 3253 F. 3/8 ISO 3253 F. M 12x1.25 F. 9/16 UNF EN 13544-2 F. Outlet connection; hose connector Ø 6 9 mm 557.1013 557.1014 557.1015 Inner volume 120 ml 285 ml 355 ml Dimension 75x60x190 mm 81x70x175 mm 81x70x207 mm Weight 0.13 Kg 0.15 Kg 0.16 Kg 254 // HOSPITAILOR

HOSPITAL STRUCTURAL PRODUCTS FLOWMETERS ARTICLE CODE 551.1026 Designed to adjust and control the oxygen flow High resisting polycarbonate inner and outer tubes Sensitive measurement by needle valve 0 15 lpm standard scaling markings FLOWMETER HUMIDIFIER BOTTLE ARTICLE CODE 551.1027 / 551.1028 / 551.1029 / 551.1030 Designed to humidify the oxygen before patient s respiration Made of polycarbonate and scaled Sterilizable up to 1210 C 150 ml and 200 ml capacity options VARIABLE AREA FLOWMETERS ARTICLE CODE 557.1016 Nipple with double thread, interchangeable by the end user I/0 switch. Quick push switch button Graduate scale reading, measurement tube with lens effect Adjusting knob. Big size, with Push&Lock position set system and Soft Grip inserts for easy handling Gas supply pressure; 280 600 kpa with an integrated pressure reducer for the stabilization of supplied pressure Gases options; O2 Air End of scale values; 5 L/min. 10 L/min. 15 L/min. 30 L/min. 40 L/min. Accuracy ±10% read value or ±0.5 L/min. (±0.2 L/min. for flows < than 1 L/min.) Standard inlet connection ISO G 1/4 M. - 1/4 NPT M. Standard outlet connection Nipple with double thread, interchangeable by the end user: M12x1.25 M - 1/4 ISO 3253 M. 9/16 UNF EN 13544-2 M -1/4 ISO 3253 M. M12x1.25 M - 9/16 UNF EN 13544-2 M. Flow calibration data; 1013 mbar 23 C Dimension: 107x61x175 mm Weight: 0.370 Kg HOSPITAILOR // 255

A. MEDICAL GAS SYSTEMS VARIABLE AREA OXYGEN FLOWMETERS ARTICLE CODE 557.1017 / 557.1018 Outlet connection easy to remove and to replace Supply max. pressure; 600 kpa Standard end of scale values - 400 kpa; 1 L/min. - 4 L/min. - 5 L/ min. - 10 L/min. - 15 L/min. -20 L/min. - 30 L/min. - 50 L/min. Accuracy; ±10% read value or ±0.5 L/min. (±0.2 L/min. for flow < than 1 L/min.) if greater Standard inlet connection; ISO G 1/8 F. - ISO G 1/4 M. - 1/4 NPT M. - 3/8 ISO 3253 F. M 12x1 F. Standard outlet connection; 1/4 ISO 3253 M. - 3/8 ISO 3253 M. - M 12x1.25 M. - 9/16 UNF EN 13544-2 M. Twin; Chrome-plated aluminium body. Twin construction. (557.1018) Dimension: 33x82x142 mm Weight: 0.15 Kg CALIBRATED ORIFICES FLOWMETERS ARTICLE CODE 557.1019 Nipple with double thread, interchangeable by the end user I/0 switch. Quick push switch button Adjusting knob. Big size, with Push&Lock position set system and Soft Grip inserts for easy handling Gas supply pressure; 280 600 kpa with an integrated pressure reducer for the stabilization of supplied pressure Gases options; O2 Air End of scale values; 6 L/min. 14 L/min. 15 L/min. 30 L/min. 50 L/ min. Accuracy; ±10% read value or ±0.5 L/min. (±0.2 L/min. for flows < than 1 L/min.) Standard inlet connection; ISO G 1/4 M. 1/4 NPT M. Standard outlet connection; Nipple with double thread, interchangeable by the end user: M12x1.25 M 1/4 ISO 3253 M. 9/16 UNF EN 13544-2 M. 1/4 ISO 3253 M. M12x1.25 M 9/16 UNF EN 13544-2 M. Flow calibration data; 1013 mbar 23 C Flow rates; 10 (0+9 preset values) Dimension: 104x61x78 mm Weight: 0.190 Kg 256 // HOSPITAILOR

HOSPITAL STRUCTURAL PRODUCTS PROBES ARTICLE CODE 551.1031 / 551.1032 / 551.1033 Probes produced according to international standards and with special label for gas Special outlet connections for O2, N2O, Medical Compreesed Air 4, Medical Gas 7 Labeling for each gas type In accordance to English (BS), German (DIN) and French (AFNOR) standards according to user requests Safe hose connection Made of chrome plated brass material STAINLESS STEEL OUTLET BOXES ARTICLE CODE 551.1034 (On Plaster) ARTICLE CODE 551.1035 (Under Plaster) Made of 304 quality S/S material Suitable for on plaster installation with the lenght of 310, 460, 610, 760, 910 and 1110 mm Several length and outlet standard alternatives MEDICAL GAS HOSES ARTICLE CODE 551.1036 (O2) / 551.1037 (N2O) / 551.1038 (AIR) / 551.1039 (VAC) Special hoses for medical gases Made of thermoplastic and rubber material Color coding according to EN 739 standard Suitable up to 20 bar pressure Inner dia: 6,7 mm Outer dia: 12 mm HOSPITAILOR // 257

A. MEDICAL GAS SYSTEMS OXYGEN STATION / NITROUS OXIDE STATION ARTICLE CODE 551.1040 / 551.1041 ARTICLE CODE 551.1042 / 551.1043 Designed to provide continuity of gas supply During exchange of the tubes, have been designed according to the principle of continuous transfer functionality Station capacities depending on the type of gas used and the distance High Pressure Reducer Cylinder Quantity 551.1040: 35 m3 2 x 3 Pcs 551.1041: 100 m3 2 x 5 Pcs 551.1042: 35 m3 2 x 2 Pcs 551.1043: 35 m3 2 x 3 Pcs HIGH PRESSURE REDUCER, SINGLE REGULATOR ARTICLE CODE 551.1044 / 551.1045 Working Mode: 4000.30: 1 stage, 1 regulator 4000.30A: 1 stage, 1 regulator with alarm Capacity: 100 m3/s Inlet dia: 1/2 Outlet dia: 22 mm Inlet pressure (max): 220 bar Outlet pressure: 4-6 bar MEDICAL COPPER PIPE ANF FITTINGS ARTICLE CODE Medical Copper Pipe and Fittings Medical grade cupper tubes provides gas switches of oxygen, vacuum and nitrous oxide lines in hospitals They are specially cleaned and the cleaning takes away malodours from any residual lubricants that may taint breathable gases. They are produced according to EN-7396-1-2 Explanation: 551.1046: 10x0,6 mm 551.1049: 10x1 mm 551.1052: 12x0,6 mm 551.1055: 12x1 mm 551.1058: 15x0,7 mm 551.1061: 15x1 mm 551.1047: 22x1 mm 551.1050: 28x1 mm 551.1053: 28x 1,5 mm 551.1056: 35x1 mm 551.1059: 35x1,5 mm 551.1062: 42x1 mm 551.1048: 42x1,5 mm 551.1051: 54x1,5 mm 551.1054: 54x2 mm 551.1057: 76x1,5 mm 551.1060: 76x2 mm 551.1063: 108x2,3 mm 258 // HOSPITAILOR

HOSPITAL STRUCTURAL PRODUCTS AREA GAS CONTROL UNIT ARTICLE CODE 551.1064 Oxygen, Nitrous Oxide, medical air 4 - surgical air 7 and vacuum connection Alarm display Choice over and under plaster Only the intervention of the technical staff to allow locked-style cover system Products are designed gas names and values outside vacuum meter transparent cover that allows you to monitor Unalarmed 1 Gas 551.1064 Alarmed 1 Gas 551.1065 Unalarmed 2 Gas 551.1066 Alarmed 2 Gas 551.1067 Unalarmed 3 Gas 551.1068 Alarmed 3 Gas 551.1069 Unalarmed 4 Gas 551.1070 Alarmed 4 Gas 551.1071 Unalarmed 5 Gas 551.1072 Alarmed 5 Gas 551.1073 MEDICAL COMPRESSED AIR UNIT & OXYGEN GENERATORS ARTICLE CODE 551.1074 / 551.1075 / 551.1076 / 551.1077 Designed to produce medical respirable air and deliver to related departments in the hospital Flexiable solutions according to end user needs PLC controlled continuous air delivery Modular& compact design Comply with MDD 93/42/ EEC Capacities And Combinations: 551.1074: Compressor: 3 x 39 m3/h Air Drier: 2 x 45 m3/h Tank: 300 L 551.1075: Compressor: 3 x 84 m3/h Air Drier: 2 x 85 m3/h Tank: 1000 L 551.1076: Compressor: 2 x 39 m3/h Air Drier: 2 x 45 m3/h Tank: 300 L 551.1077: Compressor: 2 x 84 m3/h Air Drier: 2 x 85 m3/h Tank: 1000 L HOSPITAILOR // 259

A. MEDICAL GAS SYSTEMS CENTRAL VACUUM STATION ARTICLE CODE 551.1078 / 551.1079 / 551.1080 / 551.1081 Designed to be used for central vacuum systems in operating theatres, ICUs, emergencies and laboratories of hospitals PLC controlled full automatic system Compact tank top design Suitable for low height medical gas plant rooms Medical type high efficiency bacteria filters Lubricated rotary vane vacuum pumps System capacities: 551.1078: 47 m3/hx2 Tank 500 L 551.1079: 47m3/hx3 Tank 500 L 551.1080: 100 m3/hx2 Tank 1000 L 551.1081: 100m3/hx3 Tank 1000 L MEDICAL GAS CYLINDER TROLLEY ARTICLE CODE 551.1082 Antibacterial electrostatic powder coating ABS antistatic wheels Tube holding chain For 10 liters Ask information for 5 liters Dimensions: 25x30x96 cm Weight: 2,5 kg MEDICAL GAS CYLINDER TROLLEY ARTICLE CODE 551.1083 Antibacterial electrostatic powder coating ABS antistatic wheels Tube holding chain For 10 liters and 5 liters gas tanks Dimensions: 50x50x163 cm Weight: 12 kg 260 // HOSPITAILOR

HOSPITAL STRUCTURAL PRODUCTS NURSE CALLING SYSTEMS It is an automation and communication system that patients can make calls from patient rooms, WC and emergency observation rooms. The system forward calls to nurses, nurse call panels which found in service desks, record and report service performance. NURSE CALL PANEL ARTICLE CODE 556.1001 4 Digit time and temprature display 4 Digits are used as the main indicator for the last call 4 Digits X4 lines used to indicate previous incomming calls Emergency case and nurse is in room cases displayed by LED s Events are announced by voice event buzzer as different voices depending on type of event Can manage 256 patient room WIRELESS NURSE CALL PANEL ARTICLE CODE 556.1002 Linux Based System - 99.9% Stable and well secured Oracle Mysql database Showing 5 call at same time Call queue system Priorty system for emergency calls Texting between panels Call orientation - Away from service area PATIENT HANDSET (WIRED/WIRELESS) ARTICLE CODE 556.1003 (WIRED) 556.1004 (WIRELESS) Patient hand unit provides more facilities for patient to send emergency request easily, It s easy to use, and it has been further strengthened with visual help logos. Intuitive visual aids are directed according to the needs of the patient and LEDs on confirmed sending call to the nurse. HOSPITAILOR // 261

A. MEDICAL GAS SYSTEMS HOSPITAL STRUCTURAL PRODUCTS REPEATER (WIRELESS) ARTICLE CODE 556.1005 This unit used to increase the range between nurse panel and nurse calling units. It works with 5V power supply. The unit should be used each 20 meters. ROOM CONTROL UNIT (WIRED) ARTICLE CODE 556.1006 It supports 4 bed, 1 wc and 1 bathroom Can operate without power input Its easy to adress with dip switches RESET UNIT (WIRED/WIRELESS) ARTICLE CODE 556.1007 (WIRED) / 556.1008 (WIRELESS) Console is mounted on the patient headboard. Bed set unit is connected to the headboard unit via RJ45 socket. High quality ABS raw materials Call and reset buttons are lighted with leds so they are easy to notice WC CALL UNIT (WIRED/WIRELESS) ARTICLE CODE 556.1009 (WIRED) / 556.1010 (WIRELESS) Wc Call Unit is used in the bathrooms of patient rooms. In an emergency, patient pulls the rope making an emergency call. Appears as a WC Emergency call on nurse console. System gives priority to WC Emergency calls and appears before other calls. There is a call reset button and emergency call rope on the unit. ROOM SIGNAL LAMPS (WIRED/WIRELESS) ARTICLE CODE 556.1011 (WIRED) / 556.1012 (WIRELESS) Overdoor Corridor Lamp is located above room door in the corridor Maintenance-technical support free plug and play architecture 3 different main colors (blue, green, red) Very low energy consumption and environment friendly thanks to its LED design 262 // HOSPITAILOR