Intro: by firechim on October 3, 2013

Similar documents
Pro-Form Direct Vent System

Single and Triple Rain Barrel Setup

SEADUCER BOATS GAS MONO COME VISIT US ON THE WEB AT

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

SIMPLAIR PIPING TOOL. JXT Company

Installation Instructions

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

Venting Components PolyPro

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

Methylethycetone (MEC) - PMS 60 polyurethane glue - Grease - White silicone

Aquor House Hydrant V2

SCA Series Inverted Bucket Steam Traps

Installation and Use Manual

MAINTENANCE PROCEDURE FOR X 650

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Below are the instructions to build a roller-furling unit for under $10. Read the entire process before beginning the project.

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

Tank Blanketing Pressure Regulators RHPS Series

Installation Instructions

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

8MAY15 US RACK, Inc Falcon Drive, Madera, CA

Installation Instructions

4 ANGLE GRINDER MODEL NO: CAT 52 PART

The Fastest Push-Lock System on the Market

Saf-T Vent EZ Seal Plus

GEN-1e CO2 Generator OVERVIEW INSTALLATION PROPANE GENERATORS ONLY NATURAL GAS GENERATORS ONLY

WARNING: FOR OUTDOOR USE ONLY

LIQUIP DRYBREAK COUPLER. API800 Series MAINTENANCE INSTRUCTIONS

Operating Instructions for Cobra and Lynx Duct Leakage Testers

Type B Gas Vent. Type B gas venting system. UL 441 and ULC S605. DuraFlex AL Aluminum flexible relining. UL 1777 & ULC S635.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Troyer s Gourd Rack 8 unit F R H O P

MEGR-1912 Instruction Manual

REVERSE OSMOSIS INSTALLATION Watermark 4 Stage

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Owner's Manual THAWLINE BUBBLER DE-ICING SYSTEM

VERTICAL BLADDER TANK

ACCESSORY KIT INSTALLATION INSTRUCTIONS

V-24 OXYGEN LANCE VALVE

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

Gas Welding Hoses and connections, the weak link

INSTRUCTION MANUAL. January 23, 2003, Revision 0

CLAY DIGGER. Safety, Operating, Maintenance Instructions & Spare Parts List MCD-30A 1" MCD-30A 7/8"

HORIZONTAL BLADDER TANK

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

Prestige Gas Vent Stainless

INSTALLATION AND OPERATION INSTRUCTIONS

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual STOP!

Changing Out the Rear Hub and Sprocket on a 2012 Morgan Three Wheeler Calum Fraser 17/07/2015

GAS STRUT SAFETY INFORMATION

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

JACKSON GRILLS PATIO FIRE

FLEXIBLE SHAFTING (Wet & Dry)

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

Rain Barrels. Did You Know?

Translation of the original Operating Instructions for HKS rubber compensators

1800C and 1800C-HC Series Service Regulators

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

Installation and Operation Instructions

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Vianti Falls Fire Burner Kit (HBF16) & Propane Adapter Kit (HBF16AK) (These instructions are intended for use with a 20 lb.

Anti-flood device Model B-1

BALL STOP INSTALLTION GUIDE

8. Carefully layout all the parts of the reservoir setup and clean any dirt, grime or dust from the parts. ( image 8 ) 8

Air Intake Snorkel Kit

INFLATOR TDUX-IT-16 AND GAS CYLINDER E

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

Gas Appliance Venting Products

Type BBS-03, BBS-05, BBS-06, BBS-25

Build Your Own Flamethrower Step-by-step Manual

Jerry Martin s Co 2 Snow Apparatus

3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide

INSTRUCTION MANUAL. Demountable Ice Bath Pools

GILMONT ACCUCAL FLOWMETERS

TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5. Cocking Pressure...5. Three-Way Valve Adjustment...6

1200B2 Series Service Regulators. Instruction Manual

LIQUIP DRYBREAK COUPLER. LYNX Series MAINTENANCE INSTRUCTIONS

Regulator from 1800 B series

USE AND MAINTENANCE LIGHT TOWER

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

OXYGEN ACETYLENE WELDING & CUTTING EQUIPMENT

Installation/Care/Use Manual

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

INTERLOCKED METAL HOSE

Santa Fe Cycles Assembly Guide Introduction

APP pumps APP and APP Disassembling and assembling

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

INSTALLATION INSTRUCTIONS

Flexi-pro Aerosol Delivery System (FADS) Manual

Instruction Manual. B&O WITH SLOPE BACK TENDER Live Steam

Transcription:

by firechim on October 3, 2013 Intro: Step 1: Guide for installing chimney liners with a tee connection This guide is to give you step by step instructions to install a chimney liner that utilizes a tee connection. These are normally used with appliances that are sitting outside of the chimney and have a thimble connection through the chimney wall. A chimney liner should be installed anytime an appliance is venting through a chimney. This will reduce the risks of carbon monoxide leaking, creosote buildup, and chimney fire. You will find stainless steel chimney liners available in 304 and 316 stainless steel. The 304 liners are for wood and pellet burning only and the 316 is an all fuels liner. Make sure you choose the appropriate liner for your needs. Properly sized chimney liners also improve the efficiency of your appliance and make fireplace maintenance easier. The chimney liner diameter needed is determined by the exhaust outlet size of the appliance it will be used with. You should always run the liner the full height of the chimney (we recommend ordering slightly more than is measured). Step 2: Cleaning the chimney Prior to installing a chimney liner always have it professionally cleaned to remove any creosote or other contaminants. We recommend using only nationally certified chimney sweeps. You can find a certified chimney sweep by going to the following link and entering your information: http://www.ncsg.org/search.

Step 3: Installation tools you will need You only need a few tools for a successful chimney liner installation. You'll need a razor knife, flat head screw driver, caulk gun, a pair of working gloves, and safety glasses. Shown in the picture is a grinder with a cut off wheel. The grinder will give you the best cut when cutting off the excess chimney liner. A sawzall or hacksaw will also work fine. A power drill will also be needed for the project but is not shown in the picture. Make sure you wear safety glasses and work gloves to protect yourself from harm. Step 4: Your chimney liner kit Every basic chimney liner kit is going to come with four main components: the stainless steel chimney liner, a two part tee, top plate, and rain cap. This demonstration will show a basic installation, but a chimney liner kit can be customized to fit any particular chimney. The top plate is going to be the main variable for a chimney liner kit. For this application, a no sag/no leak top plate is going to be used. Step 5: Prepare the chimney liner The chimney liner will be rolled and needs to be straightened. Simply remove any wrapping or ties from the liner and lay it out on the ground to pull it straight.

Step 6: Insulating the chimney liner To maintain UL Listing and most manufacturer's warranties for the chimney liner when wood, coal, or pellets are used with the appliance 1/2" of insulation wrap is required. When using home heating oil, natural or propane gas insulation is not required but we do recommend using it as it will reduce condensation. Simply follow the installation instructions included with the insulation kit or you can purchase the Forever Flex Pre-insulated chimney liner as shown here. Step 7: The Tee Connection You will be using a two part tee. The part of the tee connection with the cut out on the side is known as the tee body or vertical part of the tee. The part of the tee with the looping hose clamp is known as the tee snout or horizontal part of the tee. Start by locating the vertical part of the tee and insert the liner into the top of the female end. Tighten the clamp at the top of the vertical part of the tee around the liner with your flat head screw driver. This will give you a great, tight fit without having to drill screws through the liner. Place the horizontal part of the tee to the side as you will be using it later. Step 8: Insert the chimney liner down the flue The first part of the chimney liner that will be going down the chimney is the vertical part of the tee connection attached to the liner. Proceed to lower the liner down the chimney until you reach the thimble. The thimble is referred to as the hole on the side of the chimney in the living space that allows stove pipe to attach to the chimney. Twisting the flexible liner will help you install the liner if you are getting caught or hung up on the chimney walls. You should have someone located by the thimble in the living space ready to install the horizontal part of the tee.

Step 9: Installing the horizontal part of the tee Locate the horizontal part of the tee connection. First, insert the horizontal section of the tee, hose clamp end first, into the thimble. Snake the vertical part of the tee through the horizontal hose clamp until the lips of the tee body are inside the horizontal part. You will find when you look through the inside of the horizontal part of the tee that there is a worm screw. With your flat head screw driver, tighten the worm screw until the two parts of the tee connect. Take this step slowly. As stated above, the lips of the vertical part of the tee should be inside of the horizontal part.

Step 10: Connect the stove pipe to the tee Once the tee connection has been installed correctly, it is time to connect the stove pipe to the stove. Most stove pipe comes with three screws per connection point. Use your drill and drive the screws into the horizontal part of the tee and through the exhaust collar of the stove.

Step 11: Installing the top plate for the chimney liner Once the chimney liner is all the way down the flue to the point of the thimble, the next step is to connect the top plate to the top of the chimney. The main function for a top plate is to seal the existing flue from rain, wind and critters from entering the chimney. It also has a clamp located on the inside collar of the top plate to support the weight of the liner. Start by using your caulk gun and a tube of weather resistant silicone to run a bead of silicone along the top edge of the clay flue. Next, thread the chimney liner through the round collar of the top plate so that the top plate is sitting on the top edge of the clay flue. Center the top plate on the clay flue and seat it firmly in the silicone that has been run along the top of the clay flue tile. Step 12: Remove any excess chimney liner When you have successfully installed the top plate, the next step is to cut the excess liner flush with the top of the collar of the top plate. Shown in the picture is a grinder with a cut off wheel. The grinder will give the best cut, but a sawzall or hacksaw will work just fine.

Step 13: Connect the liner and top plate Once you have cut the excess chimney liner, the next step is to connect the liner to the top plate. The top plate is meant to bear the weight of the chimney liner inside the flue. On the inside collar of the top plate is a hose clamp. On the outside of the collar is a worm screw that will tighten the hose clamp. Once the liner is flush with the top of the collar of the top plate, take your flat head screw driver and tighten the worm screw so that the hose clamp tightens around the liner.

Advertisements Step 14: Install the chimney rain cap The next step is to secure the rain cap to the top plate. The collar of the top plate will get inserted inside of the rain cap. There is a suspended hose clamp at the bottom of the chimney rain cap. See the bubbled-out flange on the collar of the top plate? The chimney rain cap will bottom out on this bubbled flange. The clamp will be suspended just below the bubble to ensure a secure fit. Tighten the rain cap clamp with your flat head screw driver. Congratulations, you have successfully installed a stainless steel, flexible chimney liner! Please contact us at The Fireplace & Chimney Store if you have additional questions or need assistance. Our phone number is 888-992-9889 or email firechim@bellsouth.net.