Experience with the ZEUS central tracking detector

Similar documents
Additives that prevent or reverse cathode aging in drift chambers with Helium-Isobutane gas *

A Longterm Aging Study of the Honeycomb Drift Tubes of HERA-B Using a Circulated and Purified CF -Gas Mixture

TPC Report. D. Karlen T2K ND280m meeting December 7, 2004 Rome

arxiv: v1 [physics.ins-det] 16 Aug 2014

ETCHING OF COPPER COATED MYLAR TUBES WITH CF4 GAS. Karl M. Ecklund, Keith W. Hartman, Michael J. Hebert, Stanley G. Wojcicki

The Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

arxiv: v1 [physics.ins-det] 6 May 2016

The Mark III Vertex Chamber *

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Ion-atom interactions in a gas jet - coupling of a gas catcher to a linear RFQ cooler

A STUDY OF THE LOSSES AND INTERACTIONS BETWEEN ONE OR MORE BOW THRUSTERS AND A CATAMARAN HULL

Performance of a triple-gem detector for high rate charged particle triggering

Design and Construction of a GEM-TPC Prototype for R&D Purposes

SiD VXD Geometry Update Su Dong SLAC

On the possibilities for the readout of gas scintillation detectors for neutron scattering applications

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Yoke Instrumentation: ILD Muon System / Tail Catcher. Valeri Saveliev IAM, RAS, Russia DESY, Germany 3 June, 2016

Relative Dosimetry. Photons

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Investigation of Suction Process of Scroll Compressors

Analysis of RPC Performance with Different Gas Mixture

UK Opportunities in SiD Calorimetry

Safety Systems Based on ND Pressure Monitoring

On street parking manoeuvres and their effects on design

Numerical Tools for LCLS-II Vacuum Systems

Chapter I Standard application in photon dosimetry José Guilherme Pereira Peixoto Maria da Penha Potiens

Effects of the electric field on the electron drift velocity in a double-gem detector in different gas mixtures

EXPERIMENTAL RESULTS OF GUIDED WAVE TRAVEL TIME TOMOGRAPHY

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Cover Page for Lab Report Group Portion. Pump Performance

Phys 101 College Physics I ` Student Name: Additional Exercises on Chapter 3

TP Validating a dynamic grid model with tracer gas injection and analysis

EFFECTIVE DESIGN OF CONVERTER HOODS. 111 Ferguson Ct. Suite 103 Irving, Texas U.S.A. 400 Carlingview Dr. Toronto, ON M9W 5X9 Canada.

LX Compass module 3 Electronic compass device User manual

Tightening Evaluation of New 400A Size Metal Gasket

DESIGN AND PERFORMANCE OF THE NEW SARTORIUS 1 KG VACUUM MASS COMPARATOR AT PTB

STRIP EDGE SHAPE CONTROL

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

AIR BEARINGS IN HIGH PRECISION SYSTEMS

Study of Mixed Gas Flow Pattern Inside RPC

EXPERIMENTAL STUDY ON THE HYDRODYNAMIC BEHAVIORS OF TWO CONCENTRIC CYLINDERS

Row / Distance from centerline, m. Fan side Distance behind spreader, m 0.5. Reference point. Center line

Effect of Nozzle Twisted Lance on Jet Behavior and Spitting Rate in Top Blown Process

A high-sensitivity large volume cryogenic detector for radon in gas

A Study on Roll Damping of Bilge Keels for New Non-Ballast Ship with Rounder Cross Section

WMO LABORATORY INTERCOMPARISON OF RAIN INTENSITY GAUGES

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

Experimental Analysis of Inclined Narrow Plate-Fins Heat Sink under Natural Convection

Assembly and measurements of a mechanical prototype of the BIS MDT chamber

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Critical Gust Pressures on Tall Building Frames-Review of Codal Provisions

ACCUMULATION OF HYDROGEN RELEASED INTO A VENTED ENCLOSURE - EXPERIMENTAL RESULTS

This test shall be carried out on all vehicles equipped with open type traction batteries.

Vibrating Wire Load Cell (3, 4, 5 And 6 Gauge Cells) User Manual

23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN APRIL 2007

Performance of the Liquid Hydrogen Target

MODELLING OF FUME EXTRACTORS C. R.

Flow in a shock tube

SIMULATION OF THE FLOW FIELD CHARACTERISTICS OF TRANSIENT FLOW

Energy capture performance

The Principles of Vacuum Technology

Influence of HALO and drain-extension doping gradients on transistor performance

Time Pressure Dispensing

Pulsed Eddy Current (PEC) Inspection through Insulation

Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer

Friction properties of the face of a hand-held tennis racket

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory

Extension of the operational lifetime of the proportional chambers in the HERMES spectrometer

ATLAS RPC QA results at INFN Lecce

Technical Data Sheet MF010-O-LC

A Study of Spatial Resolution of GEM TPC with Ar-CF 4 -ic 4 H 10 Gas Mixtures

A numerical Euler-Lagrange method for bubble tower CO2 dissolution modeling

THE development of more advanced techniques in radiotherapy,

Vacuum Insulation Panels for Buildings and Technical Applications

Examples of Carter Corrected DBDB-V Applied to Acoustic Propagation Modeling

WP2 Fire test for toxicity of fire effluents

Application Note AN-107

The use of remote plasma emission spectroscopy as an alternative method of gas sensing for direct monitoring of vacuum processes

Effect of the Grip Angle on Off-Spin Bowling Performance Parameters, Analysed with a Smart Cricket Ball

The Experts in Vacuum Solutions

AN EVALUATION OF ENCAPSULATED OIL FLOODED SCREW COMPRESSOR SYSTEMS. Nikola Stosic, Ahmed Kovacevic, ian K Smith and Elvedin Mujic

The Application Of Computer Modeling To Improve The Integrity Of Ballast Tanks

MASSIVE TITANIUM SUBLIMATION PUMPING IN THE CESR INTERACTION REGION *

INTRODUCTION TABLE OF CONTENTS

FT28_mks.qxp 21/11/ :06 Page 1

Monitored Drift Tubes in ATLAS. Michele LIVAN 1. Dipartimento di Fisica Nucleare e Teorica, Universita di Pavia

Laser-Induced Bubbles in Glycerol-Water Mixtures

MANUFACTURE OF SUBSTRUCTURE BY AUTOMATED FIBER PLACEMENT

SPIRIT III Radiometer Saturation Effect

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow

EXPERIMENTAL STUDY OF WIND PRESSURES ON IRREGULAR- PLAN SHAPE BUILDINGS

Absorption measurements for a carbon fiber couch top and its modelling in a treatment planning system

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

Depleted Uranium Recovery. Sandia National Laboratory. Long Sled Track

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle

Available online at ScienceDirect. The 2014 Conference of the International Sports Engineering Association

Detecting sound wave of bubbles produced in a boiling liquid

ELEVATION CORRECTION FACTORS FOR RADON MONITORS*

DISSOLVED GAS ANALYSIS OF NATURAL ESTER FLUIDS UNDER ELECTRICAL AND THERMAL STRESS

Transcription:

Computer Physics Communications 1 Computer Physics Communications Experience with the ZEUS central tracking detector David Bailey, a, * Richard Hall-Wilton b a H.H.Wills Physics Laboratory, Tyndall Avenue, Bristol. BS8 1TL b Dept. of Physics and Astronomy, UCL, Gower Street, London WC1E 6BT presented by David Bailey Abstract The central tracking detector of the ZEUS experiment has been in operation since 1992. It is a cylindrical drift chamber, approximately 2 m in length and 1 m in diameter, and has operated reliably in a magnetic field of 1.43 T using a gas mixture of 83:12:5 Argon/CO 2 /Ethane with a trace (~0.5%) of ethanol. Initial studies conducted between 1995 and 2000 using de/dx to search for a long-term loss of gain were inconclusive. During the course of 2000, operational problems caused by repeated trips of the high voltage in the outer superlayers of the detector were experienced. These were attributed to the Malter effect, which has shown to be alleviated by the addition of water to the gas mixture. Consequently, a trace of water (~0.15%) was added to the gas and has, to date, proved to be a successful remedy. Changes in the chamber performance due to the additional water are covered and solutions to the problems encountered are detailed. 2001 Elsevier Science. All rights reserved Keywords: ZEUS; High energy physics; Charged particle; Tracking; Wire chamber; Aging; Water 1. Introduction The ZEUS experiment is one of two generalpurpose colliding-beam detectors at the HERA accelerator at DESY, Hamburg [1]. The ZEUS Central Tracking Detector (CTD) is a cylindrical wire chamber. The design concept is similar to other vector drift chambers (Mark II, SLD, CDF [2][3][4][5][6][7][8][9]). The CTD outer and inner walls are constructed from aluminium alloy, whilst the end plates are aluminium. The anode and cathode wires are grouped in radial planes known as * e-mail:d.bailey@bristol.ac.uk

2 Computer Physics Communications superlayers. There are also two cylindrical copper shields between the innermost and outermost Figure 1: Layout of wires in the CTD. One octant is shown. Wire positions are shown at the end plates at the chamber centre the stereo layers are displaced by two cells and the mean radius is smaller. superlayers and the CTD walls, which optimise the electric fields. The CTD is designed to operate in a high magnetic field (1.43 T in ZEUS) to achieve high precision momentum measurements. The high magnetic field produces large deviations from radial electron drift. The CTD was designed to operate with an angle between the electron drift velocity and electric field (the Lorentz angle) of 45º. Consequently, the cell structure of the CTD is rotated through 45º with respect to the radial direction The design goals of the CTD were threefold; to give precise measurements of charged particle momenta, to provide tracking information to all three levels of the ZEUS trigger and to measure de/dx of charged particles. The momentum measurement relies on precise position reconstruction. The resolution on transverse momentum, p t is ( ) 0.0058 0.0065 0.0014 σ p p = p p. (1) t t t t The CTD wires are arranged into nine concentric superlayers numbered consecutively from the inside out. The odd-numbered superlayers have sense wires running parallel to the chamber axis while those in the even-numbered superlayers have a 5º stereo angle. Three-dimensional information is calculated using these small angle stereo layers. Each superlayer contains eight sense wire layers there are 4608 sense wires in total. Figure 1 shows the layout of the wires in the CTD. Each sense wire is read out by a 104MHz flash analogue-to-digital converter (FADC). The FADC data are then further processed by a digital signal processor (DSP), which extracts arrival time and pulse height information from the raw hit signals. The rotation of the CTD cells has the additional benefit of ensuring a prompt timing signal for the tracking trigger as a high-p t track will cross at least one sense wire plane. The ZEUS trigger is operationally divided into three levels. The first level operates in dedicated hardware within the readout electronics of each sub-component of the detector. The CTD first level trigger (FLT) provides 3D tracking information to the ZEUS FLT. These tracks use hit data from another readout system that instruments all the wires in superlayer one and the odd numbered wires in superlayers three and five the z-by-timing system [10]. It measures the z position of a hit by calculating the difference in arrival time of a chamber pulse at either end of a wire. The timing resolution is ~300ps, which translates into a z resolution of 3.5cm. The CTD sense wires are made from 30 µm tungsten, chosen for its low dispersion for electrical signals in order to optimise the z measurement for the trigger. The high-voltage field, sense and shaper wires are all copper-beryllium alloy, ranging in diameter from 70 µm to 200 µm. The high-voltage settings are chosen to give a gas gain of approximately 10 5 whilst keeping negative surface fields below -30 kvcm -1 to avoid whisker growth. The CTD was designed to use a 50:50 Argon:Ethane gas mixture. In practice a different mixture was used 83:12:5 Argon:CO 2 :Ethane with a trace (~0.5%) of ethanol as this was considered to be a safer mixture for long-term running. Ethanol is added to the gas using a precision injector system. The properties of this mixture are similar to Argon:Ethane in terms of Lorentz angle and drift velocity although the single hit resolution and de/dx measurements are slightly degraded. The CTD has operated reliably since the start of ZEUS in 1992. Under normal operating conditions the typical sense wire currents in the innermost superlayers range from approximately 1.5 0.5 µa over the course of a HERA fill. Sense wire currents

Computer Physics Communications 3 in the outer layers are lower at around 0.5 µa. Currents in the outer layers are much less sensitive to the HERA beam as the wires lie farther away from the interaction point. The total accumulated charge over the lifetime of ZEUS is around 0.1 C/cm. 2. Initial Aging Study The first aging study of the CTD used the de/dx measurement to search for any signs of long-term loss of gain. de/dx was chosen as the test variable as it is more robust against environmental factors and Figure 3: Schematic representation of the Malter effect. 3. Operational difficulties experienced in 2000 Figure 2: de/dx measurements from 1995 to 2000. The de/dx measurement is corrected for environmental factors such as atmospheric pressure. track sample composition than using raw pulse height information. Since the CTD operates at ambient pressure, the chamber pulse heights are sensitive to atmospheric pressure variations. de/dx can be corrected for these effects. Furthermore, by selecting a set of tracks with high momentum, any variation due to the sample composition can be minimised. Figure 2 shows the de/dx measurements over five years from 1995 to 2000. The large spread in the data over the years makes it difficult to draw any definite conclusions on long-term trends. Any variation is less than 10% over the duration of the study. Towards the end of the 2000 data-taking period the CTD high voltage became unstable, tripping off continuously in some sectors of superlayers eight and nine (the outermost superlayers). The only way to recover the affected area was to remove the high voltage from it for a number of days, after which it could successfully be operated again. At the onset of the problems, the affected regions could be operated for several weeks before re-occurrence, but this interval reduced to days as the problem worsened. The high voltage problems were unrelated to any external environmental factors or beam conditions in the HERA accelerator. Anecdotal evidence did, however, suggest that the high voltage trips were correlated with the integrated luminosity that the detector had been exposed to. The problems were initially confined to the outermost superlayers, where due to the cell geometry the electric fields are higher, but moved in towards the centre of the detector over the course of a number of weeks. The suspected cause of the problem is the Malter effect [11], where thin insulating deposits on the cathode wires leads to the accumulation of a positively charged ion layer which causes high electric fields resulting in the emission of electrons from the wire surface. These electrons then cause avalanches at the anodes, resulting in exponential growth of standing currents in the chamber even when no beams are present. Figure 3 shows a schematic representation of this process. Removing the high voltage allows the accumulated charge to

4 Computer Physics Communications estimate of the water concentration in the gas is around 0.15%. Water was added to the CTD gas mixture in July 2000. The chamber operated without high voltage problems from then until the beginning of the long HERA shutdown in September 2000. There were, however, significant shifts in the operating parameters of the chamber due to the addition of water. The following sections outline the problems experienced and the solutions adopted. Figure 4: Changes to the CTD operating parameters after the addition of water to the gas mixture. The first large shift is due to the addition of water; the second results from further changes made to the chamber gas mixture to return the Lorentz angle back to 45º slowly leak away to ground, allowing the affected region to be operated again for a limited period of time until sufficient charge builds up again. 3.1. Solution and Effects The effects seen in the CTD are very similar to the problems experienced with the TASSO vertex detector [12]. In that case, the addition of a small amount of water to the gas mixture alleviated the problems and allowed the detector to operate successfully. It was therefore decided to add water to the CTD gas mixture. To avoid any major modifications to the existing CTD gas system it was decided to simply replace the 100% ethanol mixture in the injector system with a mixture of ethanol and distilled water. The final mixture chosen was 27:73 H 2 O:Ethanol. Since the gas analysis equipment available at DESY is unable to measure such small concentrations, the best Figure 5: CTD pulse height spectrum before and after the addition of water to the gas mixture. The peak to the right is caused by pulses that saturate the FADC system. Both histograms have unit area to allow a shape comparison to be made. 3.2. Changes to CTD Operating Parameters Figure 4 shows the changes to the electron drift velocity and Lorentz angle due to the addition of water to the gas mixture. Two large changes can be seen the first is due to the water; the second will be discussed later and results from the changes made to return the operating parameters to their nominal values. The main changes after adding water were a reduction in the electron drift velocity and a large shift from the design operating point of tan(θ Lorentz )=1.0. This shift in the Lorentz angle had other undesirable effects, namely a reduction in the single wire efficiency and a worsening of the hit

Computer Physics Communications 5 Figure 6: Drift velocity/lorentz angle variations with applied drift field. The solid points were measured using the test chamber and the solid lines are fits to these points. The open symbols are measurements made using the CTD after water had been added to the gas mixture. The open squares are drift velocity measurements and the open triangles are Lorentz angle measurements. position resolution. Figure 5 shows the effect of adding water on the pulse height distribution in the chamber. There was a measurable drop in the gas gain after the water was added. Both the shift in Lorentz angle and drop in gain are undesirable side effects of adding water. The next section covers the further changes that were made to the CTD gas and high voltage settings to return it to optimal operation. 3.3. Remedies 3.4. Further changes to the gas mixture The Garfield [14] program was used to investigate the variation of the Lorentz angle with gas composition. The simulations were carried out without any admixtures of ethanol or water as these were found to give inconsistent results when compared to the nominal gas mixture. Figure 7 shows the results of the simulations. Each run was taken by keeping one of the three CTD gas components constant and varying the other two, e.g. keeping CO 2 constant and increasing the ethane by 1% would It is possible to change the drift velocity and Lorentz angle simply by adjusting the high voltage. Figure 6 shows the drift velocity and Lorentz angle variations with applied voltage. The curves and solid symbols show previous measurements made in a small test chamber [13] and the open symbols show measurements made in the CTD after adding water to the gas. Clearly there has been a shift in the drift velocity/lorentz angle relation, and there was no possibility to return the Lorentz angle to 45º by adjusting the high voltage alone. Instead it was decided to increase the high voltage settings by 10% to return the pulse height spectrum to that of the prewater gas and to investigate changes to the gas composition to return the Lorentz angle to 45º. Figure 7: Results of the Garfield simulations. The left axes show the % change in gas composition from the nominal mixture. The right hand axes show the predicted value of the Lorentz angle.

6 Computer Physics Communications require decreasing the argon by 1%. It is clear from the simulation that the only possible way to change the Lorentz angle significantly was to change the CO 2 concentration. The option chosen was to reduce the CO 2 by 2% and increase the ethane concentration by 2% keeping the Argon constant. This change maintains the required operating properties of the gas whilst keeping it below the explosive limit. The second change in the CTD operating parameters seen in Figure 4 is the result of the gas change detailed above. The drift velocity drops further but remains within acceptable tolerances. The Lorentz angle does return towards 45º as predicted by the simulation, but the change is only 1.2º (from 40.9º to 42.1º). Operational concerns prevented the composition being changed any further. However, the improvement in Lorentz angle was sufficient to restore the single hit efficiency and position resolution to pre-water values. 4. Summary and Conclusions The ZEUS CTD has operated reliably for more than eight years. Initial aging studies using de/dx have shown no conclusive evidence for a significant gain loss. Operational difficulties with the Central Tracking Detector high voltage system in 2000 have been attributed to the Malter effect. The chosen solution to add a small quantity of water to the gas mixture has, to date, been successful and the chamber continues to perform well. Some shifts in its operating parameters, caused by adding water to the gas, were investigated and partially corrected by changing the gas composition increasing the ethane content of the mixture by 2% with a commensurate drop in CO 2 whilst keeping the argon concentration constant. The high voltage settings were also increased by 10% to correct a reduction in gain caused by the water. The long HERA shutdown is now coming to an end. The CTD will, once again, be at the heart of ZEUS physics. It is hoped that the operating conditions outlined here will permit successful operation until the end of ZEUS running. References [1] The ZEUS Detector Status Report, Zeus Collaboration, 1993. [2] B. Foster et al., Nucl. Instr. Meth. A 338 (1994) 254. [3] G.G. Hanson, Nucl. Instr. Meth. A 252 (1986) 343. [4] A.J. Weinstein, UC Santa Cruz Report SCIPP 87/78. [5] J.E. Bartelt, SLAC-PUB-4084 (1986). [6] SLD Design Report, SLAC-Report-273 (1984) and updates. [7] W.B. Atwood et al., Nucl. Instr. Meth. A 252 (1986) 295. [8] F. Bedeschi et al., Nucl. Instr. Meth. A 268 (1985) 50. [9] M. Atac et al., Nucl. Instr. Meth. A 249 (1986) 265. [10] D.S. Bailey et al., Nucl. Instr. Meth. A 396 (1997) 320. [11] L. Malter, Phys. Rev. 50 (1936). [12] Publ. in Proc. of Workshop on Radiation Damage to Wire Chambers, Berkeley, CA, Jan 16-17, 1986. [13] K. Long, private communication. [14] See http://garfield.web.cern.ch/garfield/ for further information.