Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung:

Similar documents
CO2 incubator with additional process controls

CO2 incubator with additional process controls

CO2 incubator with additional process controls

NEW: CO2 incubator with sterilizable sensor

NEW: CO2 incubator with sterilizable sensor

CO2 incubator with additional process controls

CO2 incubator with additional process controls

BF Incubators with forced convection

Modell Modellvariante Art. Nr. Modell Modellvariante Art. Nr.

Thermo Scientific Heraeus BBD6220 CO 2 Incubators

Thermo Scientific Heraeus BBD6220 CO 2 Incubators

Translation of the original operating manual. BF / BF-UL Incubators with forced convection

Mass Flow Controller (MFC) for Gases

FP Drying and heating ovens with forced convection and program functions. with microprocessor program controller RD3

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

Series Environmental Chambers

Precision pressure sensor Basic version Model CPT6020

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

Instruction Manual Contact Pressure Gauge

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

MANUAL KPS Pressure Control Valve

ATM.ECO - Analog Pressure Transmitter

Mass Flow Controller (MFC) for Gases

Expert Hydrostatic Level Transmitters

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

SITRANS P measuring instruments for pressure

KERN EG/EW Version /02

Pneumatic high-pressure controller Model CPC7000

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Instruction Manual Differential Pressure Transmitter

Pneumatic high-pressure controller Model CPC7000

High-speed pressure sensor Model CPT6140

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Incubators with natural convection Drying and heating ovens with natural convection Drying and heating ovens with forced convection

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

2/2-Way Solenoid Control Valve

AMS 2710 PCB pressure sensor module with V output

Programmable pressure and temperature transmitters PTM/RS485

C-Flow Coriolis Mass Flow Meters

smartdraft TM Tap & One-way beer line Infosheet

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

High-performance submersible pressure transmitter For level measurement Model LH-10

Programmable pressure and temperature transmitters PTM/RS485

deltaflowc deltaflowc Venturi or Probe

Translation of the Original Operating Manual. Safety drying ovens for drying of limited quantities of solvents

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Mass Flow Meter (MFM) for Gases

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Technical Information Conducal CLY421

Inverse Prop. Pressure-Relief Cart., Size 2 4

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

SonoMeter 30 Energy Meters

Drying and heating ovens with forced convection and advanced program functions

Digital Melting Point Apparatus

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

780S Ultra High Purity Series

ATM - Analog Pressure Transmitter

CO2 INCUBATOR CO2 INCUBATORS

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

AUTOMATIC VAPOR PRESSURE TESTER REID METHOD, DEMI SIZE MODEL AVP-30 INSTRUCTION MANUAL. Rev

Pressure transmitter PASCAL Ci4

Gas density monitor With integrated transmitter Model GDM-100-TI

Parametrable / Programmable Pressure Transmitter

Inverse Proportional Pressure-Relief Cart., Size 2 4

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Heavy Duty Dissolved Oxygen Meter

JUMO dtrans p30 Pressure Transmitter

Z, Y, and X PURGE INDICATORS / CONTROLLERS

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

Inverse Proportional Pressure-Relief Cart., Size 2 4

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

PERFORM Operating Document

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

INSTRUCTION MANUAL Pressure Relief Device LPT

FTC130 Transmitter. Operating Manual

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Level transmitter LT 100

ATM.ECO/IS - Analog Transmitter with Temperature compensation

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Customer Responsibilities

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

with microprocessor program controller RD3

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Transcription:

Drying ovens www.matronic.se FD series Drying ovens with forced convection FD series units are primarily used in applications needing rapid drying and sterilization. Totally homogenous temperature distribution, rapid dynamic response, and a special air turbine which was developed by us and has 20% higher output, have made the FD series a genuine time-saving device. Leistungsmerkmale/Ausstattung: Temperature range of 5 C (9 F) above ambient temperature up to 300 C (572 F) Electronically controlled APT.line preheating chamber technology with forced convection DS controller with integrated timer 0 to 99 hours Digital temperature setting with an accuracy of one degree One ramp function Independent adjustable temperature safety device, Class 2 (DIN 12880), with visual temperature alarm Adjustable ventilation by means of rear exhaust duct Ø 50 mm (2 inch) with ventilation flap and front ventilation slide Units up to 115 liters (4.1 cu.ft.) are stackable 2 chrome-plated racks BINDER test certificate Only at BINDER: Precision regardless of size the 20-liter (0.7 cu.ft.) bench-top units.

Technische Daten FD series www.matronic.se FD 23 FD 53 FD 115 FD 240 Exterior dimensions Width (mm/inch) 433 / 17.1 634 / 25.0 834 / 32.8 1034 / 40.7 Height (inclusive feet/castors) (mm/inch) 492 / 19.4 617 / 24.3 702 / 27.6 822 / 32.4 Depth (mm/inch) 516 / 20.3 575 / 22.6 645 / 25.4 745 / 29.3 Plus door handle, I-panel and exhaust duct (mm/inch) 85 / 3.4 105 / 4.1 105 / 4.1 105 / 4.1 Wall clearance rear (mm/inch) 100 / 3.9 100 / 3.9 100 / 3.9 100 / 3.9 Wall clearance side (mm/inch) 100 / 3.9 160 / 6.3 160 / 6.3 160 / 6.3 Exhaust duct outer- Ø (mm/inch) 52 / 2.1 52 / 2.1 52 / 2.1 52 / 2.1 Steam space volume (l/cu.ft.) 36 / 1.3 77 / 2.7 158 / 5.6 308 / 10.9 Number of doors 1 1 1 2 Interior dimensions Width (mm/inch) 222 / 8.7 400 / 15.8 600 / 23.6 800 / 31.5 Height (mm/inch) 330 / 13.0 400 / 15.8 480 / 18.9 600 / 23.6 Depth (mm/inch) 277 / 10.9 330 / 13.0 400 / 15.8 500 / 19.7 Interior volume (l/cu.ft.) 20 / 0.7 53 / 1.9 115 / 4.1 240 / 8.6 Racks, chrome-plated (number standard/max.) 2/3 2/5 2/6 2/7 Load per rack (kg/lbs.) 12 / 26 15 / 33 20 / 44 30 / 66 Permitted total load (kg/lbs.) 25 / 55 40 / 88 50 / 110 70 / 155 Weight of the unit (empty) (kg/lbs.) 33 / 73 44 / 97 62 / 137 96 / 212 Temperature data Temperature range, 5 C (9 F) above ambient up to ( C/ F) 300 / 572 300 / 572 300 / 572 300 / 572 Temperature variation 1) at 70 C (158 F) (± C) 0,8 0,8 0,7 0,8 at 150 C (302 F) (± C) 2,2 2 1,8 2 at 300 C (572 F) (± C) 4,3 3,7 3,9 4,3 Temperature fluctuation (± C) 0,3 0,3 0,3 0,3 Heating up time 1), 2) to 70 C (158 F) (Min.) 7 7 7 11 to 150 C (302 F) (Min.) 22 22 28 24 auf 300 C (Min.) 45 45 49 50 Recov. time after door was opened for 30 sec. at 70 C (158 F) (Min.) 2 2 2 2 at 150 C (302 F) (Min.) 4 4 5 6 at 300 C (572 F) (Min.) 9 9 12 13 Air change 3) at 150 C (302 F) (x/h) 64 64 32 20 Electrical data Housing protection acc. to EN 60529 IP 20 IP 20 IP 20 IP 20 Nominal voltage (±10 %) 50/60 Hz (V) 230 / 115 230 / 115 230 / 115 230 / 208 (3N) Nominal power (W) 800 1200 1600 2700 Energy consumption at 70 C (158 F) (W) 145 172 230 370 at 150 C (302 F) (W) 300 429 544 850 at 300 C (572 F) (W) 720 951 1100 1400

www.matronic.se 1) value without window 2) up to 98 % of the set value 3) The air change depends on the inner chamber- and ambient temperature and is subject to significant individual variance. The indicated air change rate represents average values for standard equipment. Individual measurement of air change rate in acc. To ASTM D 5374 are optionally available. All technical specification are specified for units with standard equipment at an ambient temperature of 25 C (77 F) and a voltage fluctuation of ±10 %. The temperature data are determinated in accordance to factory standard following DIN 12880, part 2 respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.

Options/accessories FD series www.matronic.se Access ports With silicon plugs for inserting external measuring devices into the chamber. Access ports with 10, 30, 50 mm (0.4, 1.2, 2 inch) diameter. Door with window and interior lighting For optimum process control in the interior, available for all equipment sizes. Lockable door Prevents unauthorized access and interference with processes in the chamber. Calibration certificates and validation BINDER can significantly reduce the time and effort needed for equipment qualification. We draw on unparalleled knowledge of our equipment applications and years of experience in certification. Transportable precision measuring unit For temperature, using a PT 100 temperature sensor. Suitable for universal use as an independent monitoring device for temperature chambers.

www.matronic.se Reinforced inner chamber Includes two reinforced racks for heavy loads. (Total load maximum 250 kg / 551 lbs.) Serial printer For recording temperature data. Suitable for connection to an RS 232 printer interface. Includes cables for the RS 422 interface and an interface converter. Increased air change rate Higher capacity air turbine (+ approx. 280 %) FD 23 FD 53 FD 115 FD 240 Access port with silicone plug O O O O Rack, chrome-plated or stainless steel O O O O Shelf, perforated, stainless steel O O O O Rack securings for additional fastening of racks (1 set of 4) O O O O Indep. adj. temp. safety device, Class 3.1 (DIN 12880) 230/400 V only O O O O Door with window and interior lighting O O O O Lockable door O O O O Door gasket, viton (temperature-resistant up to 200 C / 392 F) O O O O Over-temperature alarm, acoustic, can be switched off O O O O Analogue temperature output, 4 20 ma, with 6-pin DIN socket O O O O Calibration certificate O O O O Extension for calibration certificate (additional values) O O O O Stable table on castors with locking brakes - O O O Evaporating dish with rim O O O O Rubber pads for safe stacking O O O - O Option - not available Technical specifications subject to change BINDER GmbH Postfach 102 D-78502 Tuttlingen Direction: Im Mittleren Ösch 5 D-78532 Tuttlingen Contact: Phone: +49 (0) 74 62/2005-0 Fax: +49 (0) 74 62/2005-100 info@binder-world.com www.binder-world.com