AC : ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET

Similar documents
AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Series Environmental Chambers

Mitos Fluika Pressure and Vacuum Pumps Datasheet

628 Differential Pressure Decay Leak Tester

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

MIL-STD-883G METHOD

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Digital Vacuum Regulator

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

TR Electronic Pressure Regulator. User s Manual

EPP4 Pressure Regulator Basic G 1/4"

HumiSys HF High Flow RH Generator

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

Application Note AN-107

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Autocalibration Systems For In Situ Oxygen Analyzers

NATIONAL UNIVERSITY OF SINGAPORE. EE3302/EE3302E Industrial Control Systems E1: ADVANCED CONTROL SYSTEMS

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

DPC-30 DPC-100. Reference Manual

0RGHO /6 /6/6/6 /LTXLGÃ/HYHOÃ(TXLYDOHQWV

Improve Process Reliability

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

MINIBRUTE ANNEAL TUBE STANDARD OPERATION PROCEDURE

Single Pressure/ vacuum decay leak rate, loss, rate of loss, or occlusion tests with standard Cv valves.

2 Switching off ECRIS 3. 4 Acquire Beam Spectrum 4. 6 Vent Instrument Chamber 5. 7 Pump down Chamber 5. 8 Baking out Chamber 5.

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Oxygen Meter User Manual

6890 GC Site Preparation

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Cryostream 800 Series

VT900. Gas Flow Analyzer. Technical data. Key benefits and features:

Additel 761 Automated Pressure Calibrators

How to specify a product. Process Sensors and Mechanical Instruments

APPLICATION NOTES DELOMATIC 4, DM-4 GAS

Reflow Oven HHL3000 INSTRUCTION MANUAL POHUA - jedyny autoryzowany przedstawiciel w Polsce

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

living with the lab control of salinity 2012 David Hall

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Transition your department towards more productive helium-free MR operations 1

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

Calculating Total Uncertainty of Temperature Calibration with a Dry Block. Calibration White Paper. Beamex.

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Product Manual. Cyl-Tel and Tank-Tel Liquid Level Gauges. Designed and Built by: Chart Inc th Street NW New Prague, MN USA (800)

PRC CO ² -LASER PRESENTATION

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Refrigeration Scroll For Parallel Applications

Additel 761 Automated Pressure Calibrators Selection Guide

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

Additel 780 Series Pressure Controller

Fail Operational Controls for an Independent Metering Valve

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

Test Plans & Test Results

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1

LABS (Laboratory Archival Biological Storage) CRYOSTORAGE SYSTEM

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

DeeterFlow Automatic Liquid Dispenser

Columbus Instruments

IEP SENSOR BRACKET CHECKOUT AND VERIFICATION. This is a non-hazardous test.

RM-80 respiration monitor

Constant Pressure Inlet (CCN) Operator Manual

Additel 780 Series Pressure Controller

ATL. Take Control of your Helium Supply. Advanced Technology Liquefier The next generation of helium recycling

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

The Discussion of this exercise covers the following points:

KEM Scientific, Inc. Instruments for Science from Scientists

Pneumatic High-Speed Pressure Controller Model CPC3000

Model EXAxt AV550G. Averaging Oxygen Analyzer

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Proportional valves with piezo technology in medical technology

with O 2 Controller Instruction Manual

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

Additel 761 Automated Pressure Calibrators Selection Guide

SF 6 Product Guide. Gas Analysis Instruments and Accessories

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Calcium Reactor. CalcFeeder PRO. User Manual 1.1a. Model. CalcFeeder AC1 PRO CalcFeeder AC2 PRO CalcFeeder AC3 PRO CalcFeeder AC4 PRO

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators

Performa Cv Twin Alternating and High Flow Systems. Manual Supplement

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 022 MOD: 1st Issue Page: 1 of 8

MicroBulk Solutions. Next Generation Solutions for Safe and Efficient Delivery for Gas and Liquid Applications

Microscopy Cryogenic WORKSTATION. Performance by Design

Transcription:

AC 2007-1108: ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET Matthew Braley, University of Idaho Paul Anderson, University of Idaho Tracey Windley, University of Idaho Kevin Buck, University of Idaho Herbert Hess, University of Idaho American Society for Engineering Education, 2007

ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET Abstract Development of electronic devices for cryogenic temperatures requires specialized environmental chambers. The Microelectronics Research and Communications Institute required a low-cost alternative to the readily available environmental chambers. The solution was a simple aluminum cylinder cooled by pulsing liquid nitrogen into the cylinder to control the temperature of the electronics under test. National Instruments LabVIEW, GPIB communications, and simple bench top instruments control the temperature inside the chamber. This low-cost alternative will reach and sustain any set point temperature between room temperature and -190 C with an accuracy of ±5 C. Why Reinvent the Chamber? For NASA missions to the outer planets in the next two decades, reduced energy consumption means reduced payload. The development of electronics that operate at extremely cold temperatures ensure that they require less energy to keep the electronics warm enough to operate reliably. This technique reduces requirements for weight and volume of both the on-board power source and the insulation that encloses the experiments. It also helps the designers by placing the electronics closer to the sensors. In developing such low-temperature electronics, the University of Idaho s Microelectronics and Communications Institute (MRCI) recognized a need for a low-cost, low-temperature test chamber. Such chambers can be quite costly, even for a temperature range that permits cooling with liquid nitrogen. The MRCI has not previously performed cryogenic testing for developing electronics. Cryogenic testing requires special procedures and equipment, as liquid nitrogen is hazardous and requires special handling precautions. The industry standard for cryogenic testing uses large and costly environmental chambers to perform electronics testing. The cost to implement a full environmental chamber can be in excess of $40,000 for a new liquid nitrogen cooled unit. In addition to the purchase cost of the unit, liquid nitrogen must be stored and transferred with special vacuum-insulated bottles and lines. The MRCI required a cheaper alternative to the commercial environmental chambers currently available. Requirements For environmental testing at cryogenic temperatures, the MRCI needs an environmental testing chamber equivalent to liquid nitrogen chambers that are available from commercial vendors. Any temperature between room temperature and -180 C is possible in many of the commercial liquid nitrogen cooled chambers on the market. The accuracy of the temperature inside the chamber must be within ±5 C of the set point temperature. The MRCI cold temperature chamber must also be flexible to change with the MRCI for their future needs, and it must do so at a very low cost. The requirements for the MRCI cold temperature environmental chamber

must meet the following criteria: 1. Portable: One person can move the chamber 2. Efficient: It must use less than one standard transfer cylinder of liquid nitrogen for one 8 hour test 3. Capable of any temperature below room temperature to -180 C 4. Safe 5. Automated real-time temperature monitoring 6. Easy to use for MRCI personnel with minimal training 7. Adaptable to any type of package pin configuration 8. Low cost: less than $5,000 Liquid Nitrogen Input Gas Purge Chamber bottom Chamber top 64 pin sockets Figure 1 The Low Cost Environmental Chamber Low Cost Chamber The environmental chamber is a relatively simple design. The chamber is an aluminum cylinder, 23 cm diameter by 25.5 cm tall, with a removable top. Two 64-pin sockets, wired to four external D-Subminature connectors, provide electrical access to the device under test. The 64- pin socket connection inside would accommodate any type of electronic packaging with the help of adapters. Figure 1 shows the environmental chamber. PC running LabVIEW USB GPIB Controller 4 HP 34401A Digital Multimeters 1 Fluke 8840A Digital Multimeter 1 Fluke PM 2813 Programmable Power Supply 4 k type thermocouples (Chamber Temperature) Fluke 80TK Thermocouple adapter (Junction Temperature Reference) SCR Circuit for the Cryogenic liquid control valve Figure 2 Control System Communications

For the control of the chamber temperature, a National Instruments LabVIEW Virtual Instrument program, running on a PC, reads four thermocouples inside the chamber and compares the temperature with the chosen set point. The program then pulses liquid nitrogen into the chamber to adjust the temperature to match the set point. The LabVIEW program running on the PC uses a USB GPIB controller for the instrument communications. The GPIB controller communicates with several bench top instruments; four HP 34401A digital multimeters, one Fluke 8840A digital multimeter with a Fluke 80TK thermocouple adapter, and one Fluke PM 2813 programmable power supply connected to an SCR circuit for the cryogenic liquid solenoid valve. Figure 2 shows the control system communications. To measure the temperature in the chamber, the four HP 34401 digital multimeters read the voltage of each of four K-type thermocouples. The voltage read by the multimeters is the galvanic response of the thermocouple created by the temperature difference between the reference junction and the sensing junction. In the case of the chamber, the sensing junction is inside the chamber and the reference junction is outside of the chamber, at the four D- Subminiature connectors. The Fluke 8840A digital multimeter with a Fluke 80TK thermocouple adapter reads the reference junction temperature. Using the National Institute of Standards and Technology (NIST) 1 equations and coefficients for the voltage of a K-type thermocouple, the reference temperature voltage compensates the voltages of the thermocouples. In the case of compensating the junction voltage at room temperature, (1) is used to find the voltage of a known temperature. E= comp n i= 0 i C ( t ) + a e (1) i 90 measured 2 a1 ( t90 a2 ) 0 E = E + E (2) junction Adding the reference voltage to the chamber thermocouple voltages creates the compensated voltage (2). Using the NIST inverse temperature equation and coefficients and the compensated voltage, the temperature is calculated using (3). t 90 = n i= 0 i d i E comp (3) 180 Liter transfer cylinder of liquid nitrogen Fluke 8840A Digital Multimeter Fluke 80TK Thermocouple adapter Cryogenic Liquid Solenoid Valve Fluke PM 2813 Power Supply Four HP34401A DMM Chamber This process results in an accurate Figure 3 The Chamber and Control System Setup in the Laboratory

temperature measurement, as read on the multimeter, of the inside of the chamber to within ±0.1 C. A copy of the NIST coefficients used for the equations is in Appendix A. To control the temperature inside the chamber, liquid nitrogen is pulsed into the chamber in a controlled fashion. Liquid nitrogen flows from a standard 180-Liter transfer cylinder to the chamber, through a line in the top of the chamber. A cryogenic solenoid valve controls the flow of liquid nitrogen to create the required pulses. Insulated tubing provides appropriate uniformity of the pulse amplitudes. Exhaust of the evaporated liquid nitrogen gas is through a second additional line to an evaporation cooler. A hysteresis regulator controls the chamber s internal temperature by regulating pulse length and frequency. The temperature of the electronics under test inside the chamber is within ±5ºC of a set point over a range between room temperature and -190 C. The LabVIEW program reads in the temperature of the chamber and compares the temperature to the set point temperature. The program then pulses the valve to maintain the temperature in the chamber to be within ±5 C of the set point temperature. The Fluke PM 2813 power supply remotely switches an SCR circuit, thereby controlling the cryogenic valve. The chamber has another line attached to the top for a gaseous nitrogen purge for water abatement. The gaseous nitrogen purge also helps to create an even distribution of temperature throughout the volume of the chamber during off-valve periods. Figure 3 shows the entire system setup in the laboratory. The LabVIEW program is easy to use with only minimal knowledge of LabVIEW front panel operations. The front panel has three tabs for file setup, control setup, and readings. The file setup tab includes the directory settings and the header information entries. The LabVIEW program controls the temperature in the chamber according to how the user has set the system. In addition, the program is able to choose which thermocouple (or thermocouple average) controls the temperature of the chamber. The Temperature setting GPIB assignments for the four thermocouple meters GPIB assignment for the reference temperature meter GPIB assignment for the power supply Controlling thermocouple choice Tolerance around the set point Valve on/off switch Figure 4 Control Setup Tab

control setup tab has seven settings for the chamber control system: 1. The GPIB assignments for the four-thermocouple meters 2. The GPIB assignment for the reference temperature meter 3. The GPIB assignment for the power supply 4. The controlling thermocouple(s) choice 5. Valve on/off switch 6. The chamber temperature 7. The temperature tolerance around the set point Figure 4 shows the Control Setup tab. The GPIB assignments are made by choosing the correct GPIB address from the drop-down menus for each of the thermocouple multimeters, the reference temperature multimeter, and the power supply. A drop down list of choices is available for the controlling thermocouple. They are single thermocouples, the average of any combination of pairs of thermocouples, or the Start measuring button Stop measuring button Valve indicator and delay time entry Cursor ramp rates Figure 5 Readings Tab

average of all four. These options allow the user to run the test if a thermocouple fails with out the delay to replace the failed thermocouple. The tolerance around the set point can be set between 0.5 C and 2.0 C. The Readings tab shows the temperature both digitally and graphically (see figure 5). On the Readings tab, an indicator shows when the valve open command is on. In addition, the user can increase the valve delay time on the Readings tab. The Start-Reading button starts the control sequence, and the Stop-Reading button stops the control sequence. The Readings tab also has a graph to show the trend of the chamber temperature against the time. Using the cursors in the graph, the user can determine the ramp rate of the chamber. The user adjusts the temperature ramp rates by slowly raising and lowering the set point temperature. Initial Testing The initial testing shows an excellent temperature profile of the chamber to each chosen set point. It is now possible to set any temperature from room temperature to -190 C, and the steady state temperature is accurate to ±5 C of that set point. The two tests of the chamber show how the chamber reacted to the air temperature as the controlling temperature for the chamber and to the package temperature controlling the chamber temperature. The first test had electronics inside the chamber to ensure measurement of the electronics at low temperature was possible. The four thermocouples were taped, in pairs, to the two 64 pin packages inserted in the sockets. Taping all the thermocouples to the packages gave poor performance and large temperature overshoot. LabVIEW monitors the temperature of the thermocouples and adjusts the temperature to match the set point temperature. Unfortunately, the temperature of the package takes more time to decrease than the air temperature of the chamber. Using the package temperature as the controlling temperature caused large amounts of overshoot. The LabVIEW program caused the overshoot by pulsing the valve longer than required at each set point. The result was that the chamber cooled below the set point. After the package cooled to the temperature of the chamber, it took a long time to warm back up to the set point temperature. Figure 6 shows this behavior. The correction for the overshoot is simply to use two of the four thermocouples to measure an average air temperature. The LabVIEW program now can Figure 6 the Chamber Response with the Package Temperature Controlled

choose any combination of the four thermocouples to measure the air temperature. The two other thermocouples are attached to the two packages to monitor the temperature of the packages. When the package temperature converges to the set point temperature, the test at that set point temperature can begin. The second test of the chamber was with the air temperature as the controlling temperature. The graph in Figure 7 shows the tight control of the air temperature around each temperature set point. The plot of the thermocouples shows a step down of the temperature in increments to control the ramp rate to be 1 C per minute. The step down sequence was in 10 C changes with each set point held for 10 minutes. The rising temperature set points were in 20 C increments held for 10 minutes. Does the Chamber Meet All the Requirements? Figure 7 Improved Temperature Response with the Air Temperature as the Controlling Temperature This design meets all the requirements for the MRCI cold temperature chamber. The chamber is very portable, even with the added lines on the top of the chamber. One person can easily move the 7 kg chamber. The chamber reached a minimum temperature of -190 C during the initial testing. This temperature is 10 C below the requirement. The efficiency of the chamber is much greater than a commercial chamber due to the injection of the liquid nitrogen into the small chamber in controlled amounts. In addition, the line from the transfer cylinder to the chamber, and the chamber, has foam insulation to decrease the amount of liquid nitrogen used to cool the chamber. One 180-liter transfer cylinder of liquid nitrogen supplies enough liquid nitrogen for two full day tests. The LabVIEW program successfully controlled the temperature in the chamber to within 5 C of any set point temperature from room temperature to -190 C. The chamber is safe for personnel. The injection of the liquid nitrogen into the chamber keeps the liquid nitrogen isolated from the personnel. The only danger is from excessive amounts of gaseous nitrogen (evaporated liquid nitrogen) replacing the normal air in the room. A personal gas meter was purchased to monitor the level of oxygen in the air during the test to alert the user when the oxygen in the air is low. Also, the system fails safe with the control valve moving to the closed position to stop the flow of liquid nitrogen into the chamber. Only minimal training is required to run the chamber. Training in cryogenic liquid safety and LabVIEW front panel operations is all that is necessary. The chambers sockets are adaptable to

any type of electronic packaging with simple resizing adapters. It will hold 64 pin and smaller electronic packages. The chamber is a low-cost implementation for a cold temperature environmental chamber with a final cost of $2,200 for construction and materials. Table shows 1 a detailed cost list for the chamber. Item Cost Materials for Chamber $250.00 Plumbing supplies $1,700.00 Cryogenic valve $200.00 Insulation $50.00 Total $2,200.00 Table 1 Cost List for the Cryogenic Test Chamber Conclusion The MRCI now has improved testing capabilities for cold temperature testing at cryogenic temperatures. The chamber is a cryogenic temperature chamber with temperatures as low as - 190 C. The chamber is safe with no direct exposure to the liquid nitrogen, and it is portable due to the compact size of the chamber. It is efficient, as only $30 of liquid nitrogen is required to run an eight-hour test. The temperature in the chamber can be set to any temperature from room temperature to -190 C, giving a large range of temperatures to choose for measurements of electronics. It will hold the set point temperature to within 5 C until the depletion of the liquid nitrogen in the transfer cylinder. It is adaptable to any size of package, including 40 and 64 pin packages, which are the two sizes of packages the MRCI uses regularly. Very little training is required to use the chamber and run the LabVIEW program. Verifying the temperatures of the electronics is easy due to the spreadsheet file saved by the LabVIEW program. The MRCI is now equipped to perform extreme environment testing for cold temperature electronics. References 1 National Institute of Standards and Technology (1990), K-type thermocouple equations, t90 standard, available at http://srdata.nist.gov/its90/download/type_k.tab, (3 February 2005)

Appendix A NIST Temperature to Voltage Coefficients (Equation 1) name: reference function on ITS-90 type: K temperature units: C emf units: mv range: -270.000-0.000 C Coefficient Value C0 0.000000000000E+00 C1 0.394501280250E-01 C2 0.236223735980E-04 C3-0.328589067840E- 06 C4-0.499048287770E- 08 C5-0.675090591730E- 10 C6-0.574103274280E- 12 C7-0.310888728940E- 14 C8-0.104516093650E- 16 C9-0.198892668780E- 19 C10-0.163226974860E- 22 range: 0.000-1372 C Coefficient Value C0-0.176004136860E- 01 C1 0.389212049750E- 01 C2 0.185587700320E- 04 C3-0.994575928740E- 07 C4 0.318409457190E- 09 C5-0.560728448890E- 12 C6 0.560750590590E- 15 C7-0.320207200030E- 18 C8 0.971511471520E- 22 C9-0.121047212750E- 25 Exponential for 0.000-1372 C A0 0.118597600000E+00 A1-0.118343200000E- 03 A2 0.126968600000E+03

NIST Voltage to Temperature Coefficients (Equation 3) Inverse coefficients for type K: Temperature ( C) -200-0.00 0.000-500 500-1372 Voltage Range (mv) -5.891-0.000 0.000-20.644 20.644-54.866 D0 0.0000000E+00 0.000000E+00-1.318058E+02 D1 2.5173462E+01 2.508355E+01 4.830222E+01 D2-1.1662878E+00 7.860106E-02-1.646031E+00 D3-1.0833638E+00-2.503131E-01 5.464731E-02 D4-8.9773540E-01 8.315270E-02-9.650715E-04 D5-3.7342377E-01-1.228034E-02 8.802193E-06 D6-8.6632643E-02 9.804036E-04-3.110810E-08 D7-1.0450598E-02-4.413030E-05 0.000000E+00 D8-5.1920577E-04 1.057734E-06 0.000000E+00 D9 0.0000000E+00-1.052755E-08 0.000000E+00 Error Range -0.02-0.04-0.05-0.04-0.05-0.06