TONOMETRY AND PACHYMETRY

Similar documents
Appendix C: Skill Stations Examination - Marking Rubric

Appendix C: Skill Stations Examination - Marking Rubric

Biometry tips. Marilyn Watkins-Ramdin, COMT ROUB

A comparative study of intraocular pressure measurement by three tonometers in normal subjects

Ophthalmology Clinical Pearls A Quick Guide To Crystalens

Scleral Fitting Guide

Keeler Digital Applanation Tonometer (D-KAT)

U S ER S AN D M AI N TEN AN CE M AN U AL

IS YOUR TONOMETER ACCURATE? Your guide to checking tonometer calibration

INSTRUCTIONS FOR USE Applanation tonometer AT 900 / 870

POLYMACON HYDROPHILIC CONTACT LENSES PRACTITIONER FITTING GUIDE

COMPARISON OF PERILIMBAL SUCTION CUP ANALYSIS

CT210 Contact Applanation Tonometer

The effect of external compression of the eye on intraocular pressure

OPHTHALMOLOGY THE BRITISH JOURNAL APRIL, 1925 COMMUNICATIONS TONOMETRY* SCHI6TZ. OPHTHALMOLOGY for May and June, 1920, I gave an account

Injector system for implantation of 1stQ foldable intraocular lenses

CALIBRATION OF TONOMETERS*

Sofmed breathables XW (comfilcon A) Sofmed breathables XW premium (comfilcon A) Sofmed breathables XW toric (comfilcon A)

Orthokeratology. What is Orthokeratology? How does it work?

Outflow Characteristics of Isolated Anterior Segments of Human Eyes

Fitting Guide. Minutes-to-Fit 2.0. by SynergEyes Moving Vision Forward

OPESAVER Super Irrigation System

An introduction to modern scleral lenses

Studies on the ocular pressure-volume

Oxygen tension under a contact lens. Kenneth A. Poise and Marianne Decker

Acknowledgments. Paragon Vision Sciences Adoption of CRT certification slide for this generic talk. Material Considerations

Our most comfortable and intelligent Non Contact Tonometer ever

RECORDINGS OF APPLANATING FORCE AT CONSTANT INTRAOCULAR PRESSURE Development of a new technique and results obtained from a study of human eyes.

Maintenance and Calibration

Procedures for ETDRS 4M Refraction and Vision Testing. Katherine M. Burke, BS, CO, COMT CertifEYED Associates, LLC New York, New York

Eye Injuries. Chapter 25

The relationship of pressure and aqueous outflow in enucleated human eyes*

PERFORMANCE OF A FINGERSTICK

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

Ocular hazards of playing squash

Dr. Thomas R. Reim President, DreimLens, Inc.

Spherical Soft Contact Lens Fitting. J. Perrigin OPTO 6374 Spring 2017

EVERY TREATMENT IS A TRUE ORIGINAL

Vet-Temp Ear Thermometer Frequently Asked Questions

NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY

EASYPUMP II THE FLEXIBLE SOLUTION FOR SHORT AND LONG TERM INFUSION THERAPIES

MyoSure Tissue Removal System. For you and your patients.

At increased atmospheric pressure, Praetorius

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

HemoCue Hb Procedure Template

PREPARED BY: Marshall K. Cheung, Ph.D., Laboratory Director. REVISED BY: Marshall K. Cheung, Ph.D., Laboratory Director

HemoCue Training and Education Program. Capillary Sampling. Hemoglobin. USPRO1 Rev 1 3/03. Training and Education Program 2003 HemoCue, Inc.

Getting Started GUIDE LEAVE A LEGACY OF EXCELLENT OUTCOMES FOR PATIENTS WITH ASTIGMATISM. TECNIS TORIC 1-PIECE IOL pg 1

ShellPa. Standard Mechanical Cell Stretch System Model No: NNMS Serial #: User Manual

VividTrac R. Video Intubation Device. INSTRUCTIONS FOR USE. English

FITTING AND TROUBLESHOOTING SCLERAL LENSES

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

Pipetting Small Volumes

EXERCISE 8: BLEEDING TIME

v /07/17 Page 1 of 18

Citius, Altius, Fortius: Agreement between Perkins and Dynamic Contour Tonometry (Pascal) and the Impact of Altitude

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

25+ instruments answer the most common barrier to 25G instrument flexibility.

COMMUNICATIONS A RECORDING TONOMETER* designed to be mounted on the patient's forehead and to maintain its position

Management of corneal wounds: some practical tips. Lee SH, MD, FRCS (C ), FAAO

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Instructions for Cleaning Equipment: Low Level Disinfection. Beaumont Hospital, Dearborn Infection Prevention & Control 2017

REB SOP 02 Page 1 of 6. Finger Prick Blood Sampling. Effective Date April Approved by REB April Version Number 1 A.

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

I t is generally accepted that the hydraulic

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

Continual monitoring of intraocular pressure: effect

Pardon the Objection (PTO) Contact Lens Clinical Case Debate (2 hours)

Satisfaction. For you and your patients.

International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR)

(12) United States Patent (10) Patent No.: US 9,125,724 B2

COLLECTION OF BLOOD. Types of patients

Technical Note. Determining the surface tension of liquids by measurements on pendant drops

Circulation and Respiration: Vital Signs Student Version

Calculating Total Uncertainty of Temperature Calibration with a Dry Block. Calibration White Paper. Beamex.

Any laboratory is equipped with specific tools, equipment,

LENSTAR LS 900 Setting the standard in optical biometry

STANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S )

Timber Times. Safety Flyer SPECIAL POINTS OF INTEREST. Partners for Healthy Forests

How to place the EQUIVET Ocular Lavage Kit

Venepuncture. Clinical Skills. Venepuncture. Dr Brian Jenkins (Clinical Skills Lead) Sian Williams (Clinical Skills Manager)

Pressure and Flow Characteristics of Ocular Viscoelastic and Silicone Oil Through Glaucoma Drainage Devices

Pipetting and Determining Protein Concentration

Important Notices. Mouthpiece. Used properly, POWERbreathe can be used safely by almost anyone without any harmful side effects.

Lynne Sandmeyer DVM, DVSc, DACVO Associate Professor Ophthalmology University of Saskatchewan

HOW-TO CONDUCT A WEEKLY SAFETY MEETING

Physiological Considerations for Compression Bandaging. Harvey N. Mayrovitz, Ph.D.

Semi-Automatic Blood Pressure Monitor with Memory

AQUADEX FLEXFLOW SYSTEM QUICK REFERENCE GUIDE

Recitation question # 05

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

OCULAR MASSAGE BEFORE CATARACT SURGERY*

"EYE CARE AND SAFETY"

Ultrasound Guided Thoracentesis Simulator Strap-on Type

TITLE: Pulse Oximetry COMPETENCY #: Resp #1 NEW COMPETENCY REVISION DATE: 10/18/12 EMPLOYEE NAME. DATE INITIAL RE-EVALUATION ANNUAL (if required) PRN

Ultrasound Guided Thoracentesis Simulator Strap-on Type

MyoSure Setup Simplified

Transcription:

TONOMETRY AND PACHYMETRY Caroline Pate, OD Associate Professor UAB School of Optometry Birmingham, AL Intraocular Pressure (IOP) The fluid pressure inside the eye The pressure created by the continual renewal of fluids (aqueous humor) within the eye Maintains shape of eye Provides nutrients to ocular tissues Carries away metabolic waste products Helps defend against ocular pathogens Measured clinically via tonometry Recorded in mmhg Aqueous Secretion Secreted by nonpigmented epithelial cells of the ciliary body Flows into the posterior chamber, around the lens, and through the pupil into the anterior chamber. Aqueous Drainage (via two main pathways) 1. Conventional Route (Trabecular Meshwork Route) Through trabecular meshwork (TM), into lumen of Schlemm s canal, ending in the episcleral venous circulation 2. Unconventional Route (Uveoscleral Route) Across iris root, uveal meshwork, ciliary muscle, suprachoroidal space, and out through the sclera Image from Kaufman PL, Wiedman T, Robinson JR: Cholinergics. In Sears ML [ed]: Pharmacology of the eye: handbook of experimental pharmacology, Berlin, 1984, Springer-Verlag. Image from Kaufman PL, Wiedman T, Robinson JR: Cholinergics. In Sears ML [ed]: Pharmacology of the eye: handbook of experimental pharmacology, Berlin, 1984, Springer-Verlag. Aqueous Humor Dynamics The entire aqueous turns over in about 100 minutes Production must equal drainage rate Overproduction or decreased draining increased IOP Normal Intraocular Pressure (IOP) Mean IOP is about 15.5 mmhg +/- 2.6 Distribution is skewed toward high end Normal Range = 10-21 mmhg Pressure which does not lead to glaucomatous damage to the optic nerve head

Terms related to Intraocular Pressure (IOP) Factors Influencing IOP Ocular Hypertension = IOP ABOVE normal IOP is greater than 21 mmhg but there is no sign of glaucomatous optic nerve head damage Normal optic nerve head No glaucomatous visual field damage Hypotony = IOP BELOW normal IOP 5mm Hg Can lead to corneal decompensation, accelerated cataract formation, discomfort, retinal changes Time of day = Diurnal Variation Generally less than 5-6 mmhg > 10 mmhg pathologic Respiration Heartbeat Valsalva (increases 4-5mmHg) Posture (2-3 mmhg change) Voluntarily widening fissure Forced blink Exercise Pregnancy Age/Race Medications Why do we check IOP? Key Points Part of routine ophthalmic exam Post-operative examinations Never consider IOP s in isolation! There is no IOP below which optic nerve damage will never occur, nor is there any IOP above which damage will always occur. Evaluation and management for glaucoma Although IOP is not the sole component of glaucoma, it is one component of the disease we can manage Tonometry Tonometer instrument used to measure tension or pressure TONOMETRY- METHODS AND CLINICAL PROCEDURE Tonometry test that measures the pressure inside the eyes, intraocular pressure Performed on every patient capable of being tested Performed after refractive procedures but before dilation

Types of Tonometry 1. Indentation indents the corneal surface direct pressure on the eyeball determines pressure by calculating how much weight is required to flatten, or indent, an area of the cornea must account for ocular rigidity 2. Rebound o estimates intraocular pressure by bouncing a small plastic tipped metal probe against the cornea and measures the induction current that is created Indentation Tonometry Mechanical Schiotz Uses a plunger and weights to indent the anesthetized cornea Pt must be lying down Compare indentation based on weight used to a chart to determine IOP OUCH!!! 3. Applanation involves slight flattening of the cornea intraocular pressure is measured by calculating the force required to flatten or applanate an area of the cornea Imbert-Fick Law Rebound Tonometry Keep an eye on the display monitor Icare Tonometer Hand held, portable Does not use anesthetic or dyes!! Great to use with children, scarred corneas, those with disabilities Uses disposable probes P_ : standard deviation of measurements is slightly greater than normal but unlikely to have affected results; no need to repeat measurement P- : greater than normal; repeat measurement if IOP >19mmHg P : much greater than normal; repeat measurement Error messages double beep E01: Probe did not move E02: Probe did not touch eye; too far away E03: Probe speed too slow; too far away or tilted upwards E04: Probe speed too fast; tilted downwards E05: Contact with eye too soft; eyelid in way or patient blinked E06: Contact with eye too hard E07: Bad hit ; positioning/centralization on cornea wrong or probe inserted incorrectly E08: Bad data Applanation Tonometry Non-contact Estimates intraocular pressure by measuring the force of the air it takes to applanate an area of the cornea. Does not touch cornea no anesthetic needed Good for screenings Portable or stationary Sight Gags by Scott Lee, OD

Applanation Tonometry Non-contact Diaton Measures IOP through the eyelid (transpalpebral tonometry) No anesthetic required Can be used with patient in seated or reclined position Patient s gaze at approximately 45 degrees, clinician holds tonometer vertical and gently presses down on tonometer to obtain reading Electronic Tono-Pen Uses applanation and indentation principles Small size and easily portable Good for scarred corneas, patients with disabilities, and young children Most accurate tonometer if scarred or edematous cornea Uses a latex cover over the tip Requires anesthetic Correlates closely with Goldmann tonometer Approach cornea perpendicularly and applanate with gentle tapping motion Chirping sound for individual readings, beep once measurement complete Record IOP along with confidence interval of the reading reading Repeat if >20% Applanation Tonometry Perkins Uses the Goldmann applanating prism Requires anesthetic and fluorescein dye Portable (illumination built into instrument) No restrictions on patient positioning Great to use in patients who can t be positioned in SL Applanation Tonometry Goldmann Tonometry Goldmann The Gold Standard by which all other methods are compared The illuminated Goldmann probe applanates a 3.06 mm diameter circle on the cornea 3.06mm

GoldmannTonometry Alignment of Probe Side view of probe in holder Note axis scale from 0 180 If corneal cyl <3D, align with 180 mark If corneal cyl >3D, align minus cyl axis with red mark Goldmann Preparation Disinfection Clean head & chin rest of slit lamp with alcohol prep, tissue dry Probe tip requires high-level disinfection since it comes in contact with a mucous membrane CDC, Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008 High-level disinfection CDC recommendations: (HIV, HBV, HCV, HSV, Adenovirus) Wipe instrument clean, followed by: 10 minute soak in 3% H2O2 15 minute soak in 1:10 bleach dilution 20 minute soak in 2% glutaraldehyde Rinse well with sterile saline, air dry Clean probe High level disinfection with soak in 3% H2O2 or 1:10 bleach Do not leave in solution for > 1 hour! Rinse thoroughly Dry and store Tonometer probes Traditional vs. Disposable Tonometer Tips Patient preparation Explain purpose of the test to the patient Instill anesthetic + fluorescein dye Pre-combined drops available (Fluress, Flurox) or can use Proparacaine + NaFl strip Educate patient about possible sting Wait about 30 seconds for anesthetic to take effect Check corneal integrity before/after procedure Tonosafe Disposable Prism

Patient Preparation Position patient properly in slit lamp, ensuring canthus alignment Illuminate probe with cobalt blue filter, light housing positioned temporally Set pressure dial 10-20 mmhg Holding lids Proper endpoint Mires are centered and overlapped perfectly. Mire thickness is satisfactory. One semi-circle is larger than the other one. Move the probe toward the larger one. Mires are overlapping too much. Indicates there s too much force dialed in.

Mires are not overlapping. Indicates there s not enough force on the probe. Mires overlap well but they re too thick. This will result in IOP overestimation. Blot the eye & make sure lids are not touching the probe. Mires overlap well but they re too thin. This will result in IOP underestimation. Re-instill a drop of Fluress. Mires that are significantly separated and don t move much even with changes in the dial. Too much probe pressure is being applied forward with the joystick need to pull back to release some of the pressure Video of Goldmann Applanation Tonometry WHAT SHOULD WE DO?

WHAT SHOULD WE DO? WHAT SHOULD WE DO? WHAT SHOULD WE DO? Recording tonometry results Actual measurements of right and left eyes (in mmhg) Time of day Apprehension level (low, moderate, high) Type of tonometry performed Example: T 19 2:15pm, low apprehension 20 (Goldmann) Clinical Pearls for tonometry Must be QUICK and accurate Must be ready to hold eyelids if you ve got a blinker.be careful not to push on globe Don t be afraid to maneuver probe on the cornea TONOMETER CALIBRATION Calibration set at 20mmHg Calibration set at 60mmHg

TONOMETER CALIBRATION Set at 20mmHg Pachymetry For Haag Streit-style SL What does corneal thickness have to do with IOP?? PACHYMETRY can be a useful tool to better understand a patient s IOP reading Ocular Hypertension Treatment Study (2002) Thicker corneas (>555μm) give falsely high IOP readings Thinner corneas (<555μm) give falsely low IOP readings Pachymetry Billing and Coding CPT 76514 Unilateral or bilateral Ultrasound technique Includes interpretation report ~$12.00 reimbursement Billing frequency Once per lifetime per provider Glaucoma Annually Corneal graft Keratoconic Aphakic contact lens wearers Greater than annually Corneal graft rejection patients Corneal edema Corneal Hysteresis Measures the biomechanical strength, or overall resistance of the cornea In Summary Tonometry is an important part of the optometric exam Goldmann is the gold standard, but reliable alternative methods are available IOP s should never be considered in isolation Ocular Response Analyzer (Reichert)